COMPRESSED AIR & GAS TREATMENT

Similar documents
COMPRESSED AIR & GAS TREATMENT

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

DEi COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

CoolPro COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

Conditioning your ambient, maximising your comfort.

DryEnergy Hybrid. Purifying your compressed air, increasing your efficiency. refrigeration dryers 0,3-37,5 m 3 /min. Cooling, conditioning, purifying.

DRYMODULE HEAT EXCHANGER

CoolPro. Compressed air and gas aftercoolers (air and water-cooled configurations) Purifying your compressed air, increasing your efficiency.

dryer power consumption Why DE Hybrid saves energy Operational savings Seasonal savings ambient temperature débit d air comprimé

Conditioning your ambient, maximising your comfort.

New standard in compressed air treatment, providing Energy Savings up to 99%

Conditioning your ambient, maximising your comfort.

Air cooled industrial chillers with Scroll compressors and R410A refrigerant Cooling capacity kw Cooling your industry, optimising your process.

Conditioning your ambient, maximising your comfort.

Nirvana. Cycling Refrigerated Dryers

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

CoolPro Compressed air and gas aftercoolers (air and water-cooled configurations)

DEG: TWO DRYERS IN ONE, HIGHEST ENERGY ERGY SAVINGS AND MAXIMUM RELIABILITY

Nirvana Cycling Refrigerated Dryers

refrigeration drying solutions

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

PoleStar Smart Refrigerated Air Dryers don t just cycle, cycle Smart.

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Hyperchill. water chillers

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Refrigerated Compressed Air Dryers

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Refrigerant air dryers. FD series ( l/s, cfm)

pyxis pyxisa NEW rcgroupairconditioning

Refrigeration Dryers TG TI Series

Modular Air-cooled Chillers

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Refrigerated Compressed Air Dryers 5-6,000 scfm

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

INDUSTRIALS GROUP. Refrigerant Dryers. Innovative Compressed Air Treatment Solutions GDD Series

Refrigerant Dryers Refrigerant Compressed Air Dryer with integrated DF Filters

CRV Variable Operation Refrigeration Dryers scfm

pyxis u pyxis ua NEW rcgroupairconditioning

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Refrigerated compressed air dryers

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Air cooled industrial chillers

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Buran DC DC 1175 AES / WB Air cooled / water cooled Refrigeration Dryers

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

kw COOLING kw HEATING

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

ACT - VS ULTIMATE ENERGY SAVING TECHNOLOGY NEW - ENERGY SAVING VARIABLE SPEED DRYERS BY FRIULAIR

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

Adsorption Air Dryers

With the world-renowned SIGMA PROFILE

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Refrigerated Air Dryers

Refrigerated compressed air dryers

Air Preparation Systems PRD Series

QUALITY DRY AIR. Atlas Copco Air dryers SOLICITAR INFORMACIÓN MILLIE LÓPEZ ANTONIO ARROYO. FD refrigeration air dryer series Hz (477)

Boreas DV DV AB / WB

COMPRESSED AIR TREATMENT

COMPRESSED AIR TREATMENT

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

TF Series With SECOPAC LS

Easy dry line REFRIGERATION AIR DRYERS. With VSCC exclusive patented variable speed system

Modular High Capacity Refrigerated Air Dryers. TK - TM Series cfm - 12,500 cfm. kaeser.com

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

Be sustainable while protecting your business

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Product Data Sheet Refrigeration Dryer DFX

BURAN BURAN. Refrigeration Compressed Air Dryers for volume flows from 20 to 850 m³/h

Adsorption Dryers for Compressed Air

Filters & Centrifugal Separators

Industrial cooling solutions

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

UltraDry s Features and Benefits

Refrigeration Dryers TH-TI Series

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

PYXIS U PYXIS U. rcgroupairconditioning

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

REFRIGERATED AIR DRYERS

Process glycol chillers

Energy Saving Refrigerated Air Dryers SRC Cycling Dryers

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

GLIDER EVO GLIDER EVO. rcgroupairconditioning

Refrigeration dryers for energy efficient compressed air quality

Transcription:

COMPREED IR & G TRETMENT Compressed air treatment modules Nominal air flow 30 540 m³/min. Purifying your compressed air, increasing your efficiency.

The ETM DM are compressed air treatment modular units that can be connected to each other via MTER/LVE logic. Each unit integrates a high-efficiency compact aluminium exchanger, a separation system and a condensate drain. In the MTER configuration, the ETM DM modules include an electronic control unit that ensures correct operation. tandard features n extremely robust 2-in-1 heat exchanger, comprising an air-air heat exchanger, an air-glycol water exchanger optimised for an exchange in countercurrent; Demister condensate separator for perfect condensate separation also with reduced compressed air flow rates, removable using Victaulic connections; IC208CX microprocessor control and management of standard energy savings on MTER modules; Dynamic dew-point DDF energy saving function with ambient temperature tracking logic (ambient sensor DDF kit necessary); General alarm free contact; Liquid chiller remote ON/OFF control; Timed standard condensate drain with cycle times fully adjustable by the microprocessor; afety system for protection against freezing of the condensate. Options Condensate separator completely in II304; Zero loss capacitive condensate drain; Packaging for shipment by container; Packaging for shipment by sea. Kits Flanged connections kit (single module); Flanged manifold kit (connection of 2/3 MTER/LVE modules); Hydraulic connection kit (max distance 5/10 m); Propylene glycol Eco PG kit (25 kg cans); Propylene glycol concentration measuring kit; Kit R485 Modbus; upervision kit xwe300d; mbient temperature sensor DDF kit (only combined with TEevo chiller).

ETM DM the MT s modular air treatment modules for large capacity systems Installable anywhere The upgrading of large systems for the production of compressed air is often problematic and very expensive due to the lack of available space in equipment rooms. ETM DM modules perfectly solve this problem because, thanks to their compact dimensions and the possibility of being connected to a chiller located outside of the compressor room, they can also be easily integrated within existing systems. Multiple LVE modules can be connected to a single MTER module thanks to the inlet/outlet manifolds sized to minimise air-side pressure drops. It is thus possible to adapt as far as possible the combination of MTER/LVE modules to the characteristics of the installation site. Maximum reliability level Very often large systems are not designed according to redundancy criteria as the installation of multiple dryers in stand-by with the corresponding piping take up valuable space. During maintenance these systems must therefore be put offline causing costly system downtime. The modular approach of the ETM DM ensures intrinsic redundancy of the critical components and therefore enables the reduction of periods of system downtime. daptable to every need Given the flow of air to be treated and thus selected, a chiller is capable of providing the cooling power necessary for drying of the air. Using a dedicated thermodynamic simulation software it is possible to optimise system performance by choosing between several combinations of MTER/ LVE modules. It is in fact possible to choose between several chiller + drying module combinations by sizing the system to ensure optimal pressure loss level without affecting the level of electrical power absorbed while increasing the level of redundancy and safety of the system. Ultimate energy saving The load profiles of most of the manufacturing industries are highly variable. The flow rates of compressed air to be processed and the process temperatures fluctuate greatly during the day, forcing the dryers to operate at partial load for most of the time. Thanks to the energy that the TE tank is able to store in partial load conditions, the system, consisting of one or several ETM DM modules connected to a TEevo chiller, thus equates to a thermal mass energy saving dryer. The system is able to adapt its energy consumption to the actual requirement for inlet compressed air ensuring the highest level of energy saving. Integratable filtration The microprocessor board of each unit can integrate the control of an external filter. If the filter requires maintenance, a differential pressure switch with alarm free contact sends a signal to the microprocessor which generates a warning signal visible both on the display of the microprocessor control and remotely, where the ETM DM unit is integrated within a Modbus R485 network.

High energy saving COMPRION OF ENERGY VING YTEM ETM DM systems + TEevo chiller Thanks to the thermal mass technology the systems consisting of the ETM DM modules + TEevo chiller are able to adapt the refrigeration power produced according to the flow of processed air, ensuring maximum energy savings. Hot gas dryers (HGV) In the hot gas dryers (non cycling) the refrigerating compressor operates constantly regardless of the input conditions, using a by-pass valve to control the evaporation pressure. Energy consumption remains almost constant even without compressed air flow. DDF Dynamic Dew point Function (only available in combination with TEevo TECH chiller) pecial attention was paid to the management logic aimed at reducing energy needs through the dynamic dew point DDF function. The tracking logic of the DDF function ambient temperature varies the dew point dynamically thereby minimising the consumption of refrigerator compressors, protecting the system from any risk of condensate in the system as the relative humidity is maintained below 30% for each operating condition. Dynamic increasing of the dew point controlled by the DDF algorithm reduces the cooling capacity necessary to dry the incoming air and therefore further reduces energy consumption. ENERGY VING CLCULTION The following example calculates the annual energy savings of a system consisting of an ETM DM 090 module associated with a TEevo TECH 121 liquid chiller compared with an equivalent hot gas dryer. Thanks to thermal mass technology, the annual energy saving is 11.402 kwh, which is equivalent to a saving of 1.140 and a reduction of annual emissions of CO ² of 3.284 kg. ssuming operation at a temperature of +35 C, the energy saving can be further increased through activation of the dynamic dew point DDF function. Under these conditions the annual energy saving is 16.478 kwh, corresponding to an annual saving of 1.648 and an annual emission reduction of CO ² of 4.746 kg. Compressed ir Flow 90 m³/min Non-Cycling Dryers ETM DM 090 ETM DM + DDF Energy consumption per year kwh 43.926 32.524 27.448 Energy cost per year 4.393 3.252 2.745 CO ² emission per year kg 12.651 9.367 7.905 Energy saving per year kwh - 11.402 16.478 Cost saving per year - 1.140 1.648 CO ² emission saved per year kg - 3.284 4.746 POWER CONUMPTION % POWER CONUMPTION % POWER CONUMPTION % 100% 80% 60% 40% 20% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% IR FLOW % 100% 80% 60% 40% 20% 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% IR FLOW % 99% 74% 62% 40% 20% Hot Gas y-pass ETM DM amb. temp. 25 C ETM DM amb. temp. 25 C ETM DM amb. temp. 30 C ETM DM amb. temp. 35 C ETM DM amb. temp. 40 C Hot Gas y-pass ETM DM amb. temp. 25 C ENERGY VING FOR ENHCED THERML M ETM DM amb. temp. 30 C ETM + DDF ENERGY VING ETM DM amb. temp. 35 C ETM DM amb. temp. 40 C 0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% IR FLOW % Load profile: 4800 h/year, load = 70%. Energy costs = 0,1 /kwh. Kg CO ² /kwh = 0,288. HOW DOE IT WORK? The ETM DM module connected to the compressed air distribution system must be hydraulically connected with the liquid chiller via an appropriate hydraulic kit. When fully operational, the hot compressed air, and humidity load, enters the air-air heat exchanger of each ETM DM module where it is pre-cooled by the dried air exiting the dryer. The pre-cooled air then enters the air-water exchanger where the glycol water coming from the liquid chiller further cools the air until the required dew point is reached. Due to the cooling, the water vapour contained in the air condenses into liquid droplets that are effectively separated by the demister separator and then removed through the condensate drain. The cold and dried compressed air in output then returns to the air-air heat exchanger where it is heated again by the incoming air, to avoid phenomena of humidity condensation on the outer surface of the compressed air distribution system pipes. The water/glycol mixture flows through the liquid chiller evaporator where it is cooled by the coolant liquid during evaporation. In partial load conditions, the excess cooling capacity, not needed to cool the compressed air, is used to cool the fluid contained in the chiller tank (Thermal Mass). When the thermal mass reaches the set point temperature, the controller switches off the chiller compressor reducing energy consumption (in this condition the air is dried due to the energy stored in the Thermal Mass).

uilt to perform DVNCED DIGITL CONTROL ETM DM module features technologically advanced, easy-to-use microprocessor control. IC208CX manages fully independently operation of the ETM DM module and can activate the chiller using a remote ON/OFF key. CONTROL (MTER UNIT) Microprocessor control IC208CX. DVNCED LUMINUM MODULE n extremely robust 2-in-1 heat exchanger, comprising an air-air heat exchanger, an air-glycol water exchanger optimised for an exchange in countercurrent. Main features ON/OFF button to turn on the chiller remotely; Management of the IN/OUT temperatures on the air side and water side; Condensate drain programming; Manual timed drain test; nti-freeze protection function; TTL serial connection. Digital Display Readouts Pressure dew point temperature; ir-water inlet/outlet temperatures; Display LEDs: ON, common alarm, drain status, alarms codes. larms High Dew Point; High/Low inlet/outlet air temperature; High/Low inlet coolant temperature; ervice warning for an external filter; Potential-free general alarm contact; Pressure switch on hydraulic circuit. DEMITER CONDENTE EPRTOR It allows the perfect separation of condensate even with reduced compressed air flow rates. The II304 demister is installed inside a carbon steel tank (version completely in II304 available as optional). CONDENTE DRIN tandard timed condensate drain with cycle times fully adjustable by the microprocessor. Zero loss drainer (optional) with drain cycles, which are automatically managed by a capacitive level sensor, avoiding any loss of pressure. It is strongly recommended to install a pre-filter (min. filtration grade P 3μm) to prevent module and drainer clogging. MODULR DEIGN 1 TWIN 090 Thanks to the modular approach it is possible to connect up to 6 ETM DM units in MTER/LVE mode, and then to meet optimally the needs of large-capacity systems (up to 540 m³/min). In case of an expansion in the production capacity of a plant with a consequent increase of compressed air demand, it is easily possible to increase the drying capacity of the system, by adding one or more LVE modules to each single MTER module. On the right, some modular configuration examples for an ETM DM mod. 090: 2 TRIO 090 1. MTER + 1x LVE 2. MTER + 2x LVE 3. MTER + 4x LVE 4. MTER + 5x LVE Please note: filters and manifolds are available as option.

HIGH EFFICIENCY LUMINUM HET EXCHNGER ETM DM modules feature a 2-in-1 extremely robust aluminum heat exchanger including an ir to ir heat exchanger, the ir to chilled mass heat exchanger with a water separator externally connected by Victaulic joints. This advanced heat exchanger has been engineered specifically to maximize the heat transfer coefficient. Thanks to wide air channels and an oversized demister separator it ensures optimum dewpoint performance and guarantees industry leading pressure drops. ir-to-ir Heat Exchanger Hot and moist air enters the ir-to-ir heat exchanger where it exchanges heat in total counter flow with the outgoing cold air. Precooling saves energy by reducing the heat load on the evaporator section. The cold dry compressed air passes through the secondary side of the ir-to-ir heat exchanger where it is reheated by the hot inlet air it is precooling. Reheating prevents down-stream pipe sweating. ir-to-chilled mass Heat Exchanger The pre-cooled air enters the ir-to-chilled mass Heat Exchanger where it is cooled to the required dew point by exchanging heat in counter flow with the cold thermal mass fluid, allowing maximum thermal exchange. Due to the cooling effect the water vapor in the compressed air condenses in droplets that can be easily removed by the condensate separator. Moisture eparator fter cooling the cold air enters an high efficiency demister separator maintenance free (stainless steel demister) offering perfect condensate separation even at partial air flows. The condensate droplets are then removed falling into the generously dimensioned drainage chamber or sump for disposal through the microprocessor controlled drain. 3 TWIN 090 + TRIO 090 4 TRIO 090 + TRIO 090

Technical data ingle module Nominal air flow (*) Pressure drops air-side m 3 /min m 3 /h bar MTER (M) vailable versions LVE () Max no. of connectable units Power supply Connections Weight (kg) IN/OUT IN/OUT Condensate V/Ph/Hz ir side (1) Water side (2) drain(3) MTER (M) LVE () ETM DM 030 30 1.800 0,12-1M 230 /1/ 50-60 DN100 (4") Rp 1" φ 8 mm 166 - ETM DM 060 60 3.600 0,15 1M + 5 230 /1/ 50-60 DN125 (5") DN65 (2.1/2") φ 8 mm 290 277 ETM DM 090 90 5.400 0,17 1M + 5 230 /1/ 50-60 DN150 (6") DN80 (3") φ 8 mm 349 336 Multiple modules (5) Nominal air flow (*) Pressure drops air-side m 3 /min m 3 /h bar Model Configuration MTER (M) LVE () Power supply V/Ph/Hz IN/OUT ir side single module (1) Connections IN/OUT Manifold ir side (1) IN/OUT Condensate Water side (2) drain(3) without manifolds TWIN 060 120 7.200 0,17 ETM DM 060 1 1 230 /1/ 50-60 DN125 (5") DN200 (8") DN65 (2.1/2") φ 8 mm 567 647 TWIN 090 180 10.800 0,21 ETM DM 090 1 1 230 /1/ 50-60 DN150 (6") DN250 (10") DN80 (3") φ 8 mm 685 793 TRIO 090 270 16.200 0,21 ETM DM 090 1 2 230 /1/ 50-60 DN150 (6") DN300 (12") DN80 (3") φ 8 mm 1.021 1.227 TWIN 090 x 2 360 21.600 0,21 ETM DM 090 1 3 230 /1/ 50-60 DN150 (6") DN250 (10")+DN250 (10") DN80 (3") φ 8 mm 1.357 1.574 TWIN 090+TRIO 090 450 27.000 0,21 ETM DM 090 1 4 230 /1/ 50-60 DN150 (6") DN250 (10")+DN300 (12") DN80 (3") φ 8 mm 1.693 2.008 TRIO 090 x 2 540 32.400 0,21 ETM DM 090 1 5 230 /1/ 50-60 DN150 (6") DN300 (12")+DN300 (12") DN80 (3") φ 8 mm 2.029 2.441 Overall ETM DM 030 ETM DM 060 ETM DM 090 TWIN 060 TWIN 090 TRIO 090 TWIN 090 x 2 TWIN 090+TRIO 090 TRIO 090 x 2 Dimensions 970 1200 1200 1200 1200 1200 490 746 746 1400 1400 2100 C (without manifolds) 1421 1512 1507 1512 1507 1507 C* (with manifolds) - - - 1762 1843 1870 Refer to TWIN 090 Refer to TWIN 090 + TRIO 090 Weight (kg) with manifolds Refer to TRIO 090 (*) The data refer to the following operating conditions: air FD 20 C/1 bar, pressure 7 bar (g), ambient temperature 25 C, air inlet temperature 35 C, according to the IO 8573.1 standards. Operating limits: maximum pressure air side 14 bar(g); maximum pressure water side 6 bar(g); ambient temperature min/max +5 C/50 C; inlet temperature max +65 C; IP22 protection class. The hydraulic circuit should be filled with 30% anti-freezing liquid Eco PG + 70% fresh water from tap. (1) IN/OUT air-side connections Mod. 030-090: 2x weld Victaulic connections + 2x Victaulic jaws. (2) IN/OUT water-side connections Mod. 030-090. MTER module Mod. 060-090: 2x weld Victaulic connections + 4x Victaulic jaws + 2x Victaulic plugs. LVE module Mod. 060-090: 2x Victaulic jaws. (3) Condensate drain connection: polyamide pipe φ 8 mm / length 2 m. (4) Weights are net (without packing). C* (5) Multiple modules: the assembly of MTER and LVE modules and of the air manifolds is at customers' charge. C For accurate selection at conditions differing from the above the selection software should be utilized or please contact MT. M ETM DM 030 TWIN 060-090 M C* C C M C* C ETM DM 060-090 TRIO 090 * * M C* C C * * Komplettieren Complete your ie compressed ihr Druckluftsystem air treatment mit system MT Nachkühlern, with MT aftercoolers, bscheidern, Filter, separators, bleitern, filters, Öl-Wasser-Trennern adsorption dryers, und drains, Kaltwassersätzen. oil-water separators and chillers.

The images of the products in the document are for illustrative purposes only and therefore do not have any contractual value. 5050DETMD001 12-17 M.T...p.. Viale pagna, 8 ZI 35020 Tribano (PD) Italy Tel. +39 049 9588611 Fax +39 049 9588676 info@mta-it.com www.mta-it.com MT France.. Tel: +33 04 7249 8989 www.mtafrance.fr MT Deutschland GmbH Tel: +49 (2157) 12402-0 www.mta.de Novair-MT,..U. (España) Tel: +34 938 281 790 www.novair-mta.com C MT ROMÂNI rl Tel: +40 723 022023 www.mta-it.ro MT is represented in over 80 countries worldwide. For information concerning your nearest MT representative please contact M.T...p.. The data contained herein is not binding. With a view to continuous improvement, MT p reserves the right to make changes without prior notice. MT U, LLC Tel: +1 716 693 8651 www.mta-usa.com MT ustralasia Pty Ltd Tel: +61 1300 304 177 www.mta-au.com MT is IO9001 certified, a sign of its commitment to complete customer satisfaction. MT products comply with European safety directives, as recognised by the CE symbol. EC Declaration