WARM-MB. Warm Line. Thermostatic cells for medical fl uids in bottles and bags

Similar documents
Plasma Thawer. model WPFD. Comformity with: GMP CNT JACIE FACT. WPFD Plasma Fast Thawer Medical Device - CEE 93/42

Refrigerated Incubators / Environmental Testing Chambers

Harvey Chemiclave 5000 Owner And Operator Guide

Spectron LSN (Life Safety Network) Suggested Specifications

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

EM-MED. EmTherm. warming. cabinets

Heated and Refrigerated Incubators

PORTABLE ROLLER OVEN Part No CONTENTS DESCRIPTION

PATENTED PATENT PENDING PATENTED PATENTED

GCW SERIES Gas Cylinder Warmers

THERMOELECTIRC WINE COOLER

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Series 25B Photoelectric Sensors and Light Scanners PRODUCT INFORMATION

Overview. rotary microtomes

300 series HPLC autosamplers

Refrigerator/Freezer Thermometer

MAC N-407 Air-Cooled Chiller

Installation Instructions for Kay Chemical / Power Soak Dual Dispenser Pump (01/02/03)

Installation Manual SPA BROADWAY MAXI

ONE SERIES CONDENSING WALL HUNG BOILERS. For further information visit our website ariston.com HOT WATER HEATING RENEWABLE AIR CONDITIONING

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Refrigerator/Freezer Thermometer

IMPORTANT SAFETY INFORMATION READ ALL...

PATENTED PATENT PENDING PATENTED PATENTED

SYRINGES PROCESSING OF PRE-STERILIZED SYRINGES

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A

Temperature Solutions Line Card

Model 7700 Pump Director Valve and Pump Motor Interface Controller

Ultrasonic Switches. Features & Benefits

CER-1 & CER-2 Installation & Testing Instructions

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

PR / MP I Laboratory / Medicine

Topside Control Instructions for Single Pump Spas

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

ELMTEC. Kattreppeln Königslutter / /

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

easyspiral The world's fastest Spiral plater

Versatile Design Helps Solve Today s Lubrication Challenges.

THERMOELECTRIC COMBO COOLER. Model: DX-68 COMBO. Operation Manual

LR range (solid door) LR 750 G / GG

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

THERMOSHRINK SLEEVE & CAPSULE SHRINK TUNNELS

ACCESSOIRES ELECTRICAL ACCESSORIES

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

KEM Scientific, Inc. Instruments for Science from Scientists

USER MANUAL FOR THE ENTERTAINER 36 CUBE ICE MAKER. Ice Maker.

Advanced Water Cooling Systems for Power Electronics High performance at heat source High reliability in cooling solutions

Syringe Pump. Syringe Pump. Product Model: ZD-50C6 Syringe Pump. ZD-50C6-H Syringe Pump

SimpleVIS Viscometer Reference Guide P

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

DISHWASHING EQUIPMENT. Front-Loading and Pass-Through Dishwashers

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

FORM (October 2010)

The Hydrim M2 washer disinfector. Perfectly prepares large volumes of instruments for sterilisation.

THERMOELECTRIC WINE COOLER. Model No: ART29614

Floor sensor (NTC) Temp (C o ) Value (kohm) 10 o C 19,9 kohm 15 o C 15,7 kohm 20 o C 12,5 kohm 25 o C 10,0 kohm 30 o C 8,0 kohm

MACH N-407 Heat Pump Air-Cooled Chiller

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

LOGIC CONTROLLED DEKO 25 EASE OF USE

TITAN SYSTEM ENGINEERING DATA SHEET TITAN HXS

Performance effective productivity per hour Washing results Savings Easy cleaning

Vacuum Ovens VO. From orange juice to electronic chips vacuum technology protects heat-sensitive materials

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

Adsorption Dryers for Compressed Air

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

10. Water Dispensers

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

HYDROCYCLONE ISO 18 INDEX. Page

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

1 Intended Use of the Breas HA 01 Humidifier

products and services

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

OGB Poly Care 2 Incubator Service Manual

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Concepts for the secure networking of large building complexes

Constant climate chambers

Electronic Pellet Burner Controller NPBC-V3-1

Evaporators. In this section. Rotary Evaporators Crystalisation Distillation Drying Reflux Solution Concentration Volatiles Glassware

The future is bright. And clean. And fully automated.

Flusher disinfectors for hospitals and nursing houses

DEKO 25 washer-disinfector

LEVENS STEAM SHOWER ENCLOSURE

cgmp STEAM STERILIZERS

Power X High Power Condensing Wall-Hung Boilers

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Shaking water baths. OLS26 Orbital/Linear shaking water bath. LSB12 & LSB18 Linear shaking water baths

Conveyor and Batch Reflow Ovens

OT 300/430/570 STEAM STERILIZERS

POLOS Options

Incubators. with BioCote antimicrobial protection

Transcription:

Warm Line Thermostatic cells for medical fl uids in bottles and bags

Warm-MB Thermostatic cells for medical fl uids Applications The thermostatic cell is used to heat and maintain medical fl uids for diagnostic and therapeutic use to body temperature. The Warm-MB can be used for fl uids contained in glass or plastic bottles, or in soft plastic bags. Features The thermostatic cell is heated using electrical resistance combined with forced air ventilation. It is entirely made of stainless steel both internally and externally, so it can be cleaned completely with normal cloths using ordinary detergents and disinfectants. The device is equipped with a temperature control system that maintains a temperature of 36 C / 96,8 F with a tolerance of ±1 C / ±1,8 F. Constant temperature is assured, regardless of the ambient temperature and the temperature of incoming fl uids, provided the ambient temperature is not above 35 C / 95 F or below 15 C / 59 F. This precise temperature is controlled and maintained thanks to a dual safety system and closed-loop regulating system. In order to prepare the fl uid for ready use at the required time, the device is provided with a special user- programmable timer that automatically switches on the device at a pre-set time. This programming must take place six hours and thirty minutes before the fl uids are needed. The temperature cannot be set by the users as it is fi xed beforehand. The front panel display is used to present device status or anomaly conditions to the operator: Forced air ventilation failure No heating, failure of electrical resistance heater Over temperature or under temperature General specifi cations: Power supply: 230 VAC 50 Hz. Measurements: 540 x 380 x 515mm Weight: 18 Kg Capacity: 27 l - 500 ml : 16 vials or 16 bags - 250 ml : 24 vials - 100 ml : 34 vials

Warm-SB Thermostatic device for glass bottles Applications The Warm-SB is designed to maintain a bottle containing fl uid, in particular CT/Angiography/Haemodynamics/ scanning contrast media, at body temperature for diagnostic imaging purposes. The device is particularly suitable for 500/250ml glass and plastic bottles. Purpose For correct diagnostic imaging technique, contrast media should be administered at body temperature. Normally warming in a special thermostatic cell, e.g. Warm-MB, occurs before use. The contrast media is then transferred to the injector syringe, which has a maximum capacity of 250 ml and is equipped with a heating sleeve that serves to maintain the temperature. In the case of 500 ml bottles the residual fl uid (250 ml) remains at room temperature for a prolonged period, corresponding to the time between procedure and the infusion time of the contrast agent in the loaded syringe. In these conditions the contrast media cools, and as a result it is no longer at body temperature when it is transferred to the injector, resulting in infusion of a fl uid that is at a lower temperature than intended. The Warm- SB device serves to maintain the bottle at a constant temperature (body temperature) for the time necessary to complete the infusion of the contrast media present in the injector. This ensures the residual fl uid is infused at body temperature. Main features Warm-SB is provided with a heating system which keeps the fl uid contained in a bottle at body temperature for an unlimited time. If the bottle has been pre-heated in the Warm-MB, the Warm-SB should be used immediately afterwards to maintain the temperature. Technical specifi cations The device consists of a heating system provided with heating bands, wrapping an envelope of conductive material where the bottle is housed. The conductive envelope is wrapped by insulating material. The unique design of the device avoids the contact of liquids with the electrical parts in the event of accidental break of the bottle. The device is powered by 220-110 Vac, according to the country where it is used. Working temperature: 36 C ± 1 C. Operating instructions The supply unit available on the cable connecting the device to the mains supply is provided with main switch with warning light. Also the device is provided with specially designed switch on the panel. The housing seat of the bag is provided with 2 leds: white for visualization of the bag two/colored yellow/green: - continuous yellow: heating stage - fl ashing yellow: fault/error reporting - continuous green: achieved temperature. In case of failure or of any anomaly, the event is reported by the fl ashing yellow led. For safety reasons the device interrupts heating in this situation. Final note If the size of the bottles is compatible with the geometric characteristics of the Warm-SB, it can be used for any fl uid type that s preferred to be administered at body temperature.

Warm-SP Thermostatic cell for medical fl uids in bag (single bag) Applications The device is designed for the maintenance at body temperature of fl uids contained in fl exible bags, in particular, CT/Angiography/Haemodynamics/scanning contrast media, at the transfer stage of the contrast from the bag to the injector. Purpose Such a requirement is due by the utilization conditions with devices for CT scanning of the last generations. These devices allow high performing examinations but require high viscosity contrast media, which are to be administered at high capacities. These two elements: capacity and viscosity generate high pressures, which lead the injectors to adjust automatically. As a result, the set capacities are not maintained. The only solution to the problem is to reduce the contrast viscosity. Such an objective is achieved by increasing the contrast temperature from the ambient temperature to the body one. The aim is to guarantee the maintenance of body temperature of the contrast, contained in 100/200/500 ml bags for the whole quantity of the contrast contained thanks to the bag pressing device provided on the door. The immediate maintenance of the body temperature is guaranteed if the bag is preheated by means of the device Warm-MP and immediately put inside the device Warm-SP, before being transferred to the injector. Main Features The device is provided with a 24 volt powered electrical resistance heating system, which guarantees the maintenance of the body temperature for the whole quantity of the contrast contained in the bag, independently of the utilization time of the whole quantity. Technical specifi cations The device consists of a heating system provided with heating bands, wrapping an envelope of conductive material where the bag is housed. The conductive envelope is wrapped by insulating material. The unique design of the device avoids the contact of liquids with the electrical parts in the event of accidental break of the bag. The device is powered by 220-110 Vac, according to the country where it is used. Working temperature: 36 C ± 1 C. Operating instructions: The supply unit available on the cable connecting the device to the mains supply is provided with main switch with warning light. Also the device is provided with specially designed switch on the panel. The housing seat of the bag is provided with 2 leds: white for visualization of the bag two/colored yellow/green: - continuous yellow: heating stage - fl ashing yellow: fault/error reporting - continuous green: achieved temperature. In case of failure or of any anomaly, the event is reported by the fl ashing yellow led. For safety reasons the device interrupts heating in this situation.

General Specifi cations Warm Line General Specifi cations for Warm-MB: Power supply: 230 Vac 50 Hz. Measurements: 540 x 380 x 515 mm (W,H,D) Weight: 18 Kg Capacity: 500 ml: 16 vials or 16 bags 250 ml : 24 vials 100 ml : 34 vials ORDERING GUIDE CODE DESCRIPTION Package Q.ty Warm-MB Thermostatic cell for medical fl uids 1 Unit General Specifi cations for Warm-SB: Power supply 100-240 Vac 50-60 Hz - External dimensions Heating part: 198x190x143 mm - Power supply unit: 160 x 120 x 90 mm - Net weight 2.5 kg - Diameter of usable bottles: Without adapter: from 78 mm to 86 mm - With adapter: 66 mm ORDERING GUIDE CODE DESCRIPTION Package Q.ty 20029001 Warm SB - Heater for 500ml glass bottles 1 Pcs 20029003 Warm SB - Adapter for 200-250ml bottles 1 Pcs General Specifi cations for Warm-SP: Power supply 100-240 Vac 50-60 Hz - External dimensions Heating part: 198x240x155 mm - Power supply unit: 160 x 120 x 90 mm - Net weight 2.5 kg Capacity One 500/200/100ml bag ORDERING GUIDE CODE DESCRIPTION Package Q.ty 20029004 Warm-SP - Heater for 100/200/500ml bags 1 Pcs

Via Statale Sud, 169 41037 San Giacomo Roncole - Mirandola (MO) ITALY T. +39.0535.25523 - F. +39.0535.25635 info@sidamit.com www.sidamgroup.com