Eco Active H E A T R E C O V E R Y S Y S T E M S H Y B R I D U N I T. W: T:

Similar documents
Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

External insulated volume. control damper

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

HYBRID PLUS2 AIRCOOL VENTILATORS

VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors

The new Xcell EC High Efficiency Range Fresh air pure and simple

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide

HYBRID PLUS2 AIRCOOL VENTILATORS

iq Star LYRA II chilled beam cassette

Document # R01

Fan Coil Unit (FCU) Application Guide

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Installation Guide. Ceiling PIR Detector (311) Features and Connections

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Installation and Maintenance

Installation and Maintenance

Installation and Maintenance

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide. SE8600 Series Room Controllers

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Assigning profiles to a Breathing Buildings NVHR Unit (NVHR900 & NVHR1100)

ACTIVE VENTILATION SYSTEMS

Domestic & Commercial Fans

Installation and Maintenance

Rooftop Unit, Heat Pump and Indoor Air Quality Application Guide VT8600 Series Room Controllers

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

Ducted Air Conditioning

Installation and Maintenance

Wireless Plug Load Control

Installation and Maintenance

WHHR Midi & Midi Lite

iq Star LYRA II chilled beam cassette

Ducted Air Conditioning

Hybrid Thermal Mixing Ventilation Systems

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

ECO dmev Decentralised MEV

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Small Room Heat Recovery Ventilation

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

CHILLED BEAM CASSETTE IQ STAR LYRA

SIMPLICITY FULL MODULARITY?

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Zehnder Comfosystems. ComfoAir 180 Datasheet

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

FUME EXTRACT STRATEGY STATEMENT

EVH Hybrid Ventilation Unit

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Centrif Duo & Centrif Duo Plus

CONTENT: VEX308 Decentralised ventilation VEX308

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Regulations covering Heating and Ventilation equipment in Schools

Central Heating and Ventilation

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

7. MECHANICAL SYSTEM DESIGN

VENTILATION DESIGNED FOR CARE HOMES

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Centrifugal extract and condensation control fans

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

Larch house and Lime house review of systems design and implementation

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Assigning profiles to an e-stack or Passive Stack (S1500, S1200 & R-Series)

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

ELECTRONIC SOUNDER STROBE Model : AVD-C407

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

NATURAL VENTIL ATION. commercial louvres solar shading design consultancy sales and installation natural ventilation

The Sentinel Kinetic Horizontal Range

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

AIR DIFFUSION A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY CHILLED BEAMS. iq Star Lyra II iq Star Stella Flexicool IQID

SIMPLICITY OR FULL MODULARITY?

Warnings, Safety Information and Guidance

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Ventilation Unit Zehnder ComfoAir 350

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Lo-Carbon Quadra SELV

Demand Controlled Ventilation - With the windows shut! AHUs. For consistently good indoor air quality DATA LO GG ER. Scan to visit website

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Lo-Carbon Sentinel Kinetic Horizontal

7 YEAR. The DRIMASTEReco Range DRI-ECO-HC NUAIRE S PIV: HALL CONTROL

Conditioning your ambient, maximising your comfort.

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

IOS MANUAL. Installation, Operation, and Service Instructions. Fresh Filtered Air Ventilators with Efficient Heat/Cool Recovery from Indoor Air

Best Practice Guidance. Best Practice Guidance Positive Input Ventilation (PIV) System

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

GLOBAL FINISHING SOLUTIONS

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

Ceiling swirl diffusers

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

Ceiling swirl diffusers

Transcription:

Eco Active H Y B R I D U N I T W: www.gdl.co.uk T: 01457 861538

Eco Active Hybrid Unit The Eco Active Hybrid unit is designed to provide ventilation in both summer and winter seasons. Ventilation is achieved using the naturally occurring forces of air movement, wind and buoyancy by creating a differential in pressure within the unit. The unit incorporates an ultra-low energy fan to assist (as and when required) in providing ventilation at all times and the unit is kept pressurised to ensure an efficient natural ventilation solution with the added benefit of heat recovery. Features Low noise operation Independently tested meeting BB93 Ensure both indoor air quality and temperature remain within D of E guidelines Low energy fans providing up to 100 l/s or 300 l/s Easy to use in room wall mounted controller Summer boost mode Night purge mode Compact size Available in a range of colours Duct work compatible Low maintenance

Design The hybrid ventilation units can be installed within high level ceiling voids or exposed within the room, the ceiling void units are supplied with spigots for ductwork connections. The unit uses air buoyancy with low energy fan assistance to deliver the supply of fresh air whilst mixing a controlled amount of extract air for heat recovery without the need for a heat exchanger. Low profile compact design Volumetric air flow control Silent, below 35dB noise rating Various colour options available

400 500 x 250 1000 300 x 250 Plan view (exposed unit) 1800 Side view (access) 1800 View on extract grille Isolator

View on supply grille Control panel View on atmosphere side Plan view (hidden unit c/w spigot connections) 500 x 250 300 x 250 500 x 250 300 x 250

Winter Mode The temperature set point for the classrooms is typically 21 o C. The room sensor will detect this has been achieved and it will monitor the CO 2 level for indoor air quality. When the CO 2 levels rise above 1000ppm (adjustable), the ventilation system will begin to operate. Note The CO 2 levels proposed for ventilation are taken from the government guide BB101. The fresh air Damper will begin to open, at the same time the re-circ mixing damper will fully open to allow fresh air to enter the classroom. An air temperature sensor will monitor the supply air temperature ensuring the temperature remains above 17 o C If the CO 2 levels rise above 1200ppm, the ventilation fans will begin to run, delivering up to 4l/sec/person to each classroom. The air mixing damper will open to ensure the entering air temperature is above 17 o C. Summer Mode The temperature set point for the room is typically 21 o C (adjustable). When the ventilation fans will run to maintain this temperature. If, with full fresh air being 8l/sec/person, the room temperature rises to 24 o C (adjustable) supplementary cooling can be activated to reduce the room temperature to 22 o C. When the lower temperature has been achieved, the ventilation system will continue to run to maintain a space temperature below 24 o C.

Night Purge During hot summer months, night time cooling through ventilation only will be enabled. The ventilation fresh air dampers will open and the fan will run to reduce the space temperature to 18 C (adjustable). Optional External Combined intake discharge louvre This unique louvre offers both air intake and discharge within the same panel. The louvre can be installed with the blades vertical or in horizontal as air is discharged at 45 o avoiding short cutting and cross contamination of the incoming supply air. The rear bank of blades provides the louvre with additional water ingress protection. The louvre can be manufactured in flanged or recessed frame including a glazed in option for window frames.

Smart Control The smart room controller is an application configurable wall mounted controller with the ability to integrate into network devices that support BACnet MSTP or Wireless ZigBee mesh network technology. Wireless not available for this model Customisable Touch Screen The touch screen of the room controller offers a customizable user experience with selection of languages, temperature scales, buttons, and screen colours, it also supports the upload of an image or logo that becomes the default standby screen of the device. Custom messages can also be displayed on-screen using BACnet objects when the room controller is integrated via a BACnet MS/TP sys-tem. Optional Passive Infrared (PIR) All models can be equipped with a discrete optional passive infrared (PIR) motion sensor. With the embedded sensor, the room controller uses advanced occupancy routines to generate automatic energy savings during occupied and unoccupied periods without sacrificing occupant comfort.

www.gdl.co.uk sales@gdl.co.uk GDL Air Systems Ltd, Air Diffusion Works Woolley Bridge Rd, Hadfield, Glossop Derbyshire, SK13 1AB