Installation Manual. Model 200QF 8/8 Model 200QF 8/ DC Edge III

Similar documents
Installing the Cisco ONS FAP-4 Fuse Alarm Panel

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

Installation and Operation Manual Low Power (LP) DC Power System

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

Public Safety DAS Annunciator Panel

Owner s Guide and Installation Manual

Rack Mount Series Installation Guide

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

CEILING FAN OWNER'S MANUAL

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

GDC 087R Issue 2 - May Installation and Operation UAS Shelf/Enclosure. General DataComm

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Owner s Guide and Installation Manual

PART GENERAL 1.01 SECTION INCLUDES

Line Isolation Monitor (LIM) LIM2000plus

AC/DC Power Supply and Battery Charger Installation and Maintenance

* Consult factory on conditions for approval acceptability

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

SP-1000X. Panic Device Power Controller Installation Guide. Rev

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Products :: Circuit Protection :: Thermal Circuit Breakers

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

CPS3200U Technical Support Guide

CEILING FAN OWNER'S MANUAL

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Installation Guide for models:

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

FerronTM. Instruction Manual A Kichler Decor ceiling fan

OG5000 Ozone Generator Model OG5000B-A. User Manual

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

SC-6 Six Supervised Control Module

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

GRANDE OWNER S MANUAL

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

CEILING FAN OWNER'S MANUAL

Owner s Guide and Installation Manual

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

MODELS ASHP, ASHH, ASUP, and ASUH

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

MODELS 304GC, 304GCX, 314GC, and 314GCX

Installation Guide for models:

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

LORAIN CIP 4890/48120 DC Power System

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Owner s Guide and Installation Manual

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

P/N CC-100. Coolant Circulator. Operation manual

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

INSTALLATION INSTRUCTIONS

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Viking Installation Guide

CPS2400U Upstream System 19

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

CEILING FAN OWNER'S MANUAL

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Hanson LED C e i l i n g F a n

CEILING FAN OWNER'S MANUAL

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Installation Instructions

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

DRAIN WATER TEMPERING INSTALL

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Beacon 410A Gas Monitor Operator s Manual

Owner s Guide and Installation Manual

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

SECAP Conveyor TC72 / Dryer TD72

Installation Instructions

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Installation Instructions

Transcription:

Installation Manual Model 200QF 8/8 Model 200QF 8/8 +24 DC Edge III Model 200QF 8/8 +24; Model 200QF 8/8 Part# 1101-1006 (Positive Polarity); 1101-1051 (Negative Polarity)

Installation Manual DC Edge III Table of Contents DC Edge III Introduction 3 Product Specifications 4 Factors Affecting Installation 6 Installation Procedure 7 Inspect Shipping Container 7 Inspect Contents of Container 7 Accessory Kit 8 Mounting Panel to Rack 9 Torque Rating Chart 9 Ground Wiring 10 Inputs 10 Test Voltages & Alarms 12 Outputs 15 Alarms 18 Maintenance 19 Breaker Replacement 19 Alarm Board Replacement 20 Service 20 Circuit Breakers 21 Lugs 22 Dimensions 23 2

DC Edge TM III INTRODUCTION Transtector s DC Edge III is a compact (1RU) mid-current, ±24 Vdc or -48 Vdc power panel featuring quad-feed 100 A buses for secondary power distribution. DC Edge III provides power for a wide range of local or remote, wireless and wireline, data and communications applications. The panel fits 19 in. or 23 in. racks. DC Edge III supports the use of four, Carling Technologies M-Series or Airpax SNAPAK breaker output positions per bus. Transtector supplies blank covers for all breaker positions. Breakers (.1A to 30A) are sold separately and installed on site. Buses A1, A2, B1, and B2 BATT feeds are mutually isolated, except for the replaceable alarm board which accepts power from A1 or B1 buses. The two Side A RTNs are strapped together and the two Side B RTNs are strapped together. The alarm board on the front of the panel contains eight LEDs: one for each feed (green when power is on and off when power is off); one for the breakers (off during normal operation and red for a tripped breaker); and one each for MIN, MAJ, and CRT bay alarms. Along with the LEDs on the front, Form C dry contacts on the rear provide connectivity via two, 15-socket (female), D-type connectors to remote audible/visual alarm devices for announcing/displaying power, breaker, and bay failures. The replaceable alarm board also features four dip switches to enable/disable bus status and alarms. The alarm board can be hot swapped, that is, removed without powering down the panel. All BATT and RTN inputs and ground receive dual-hole lugs. (Transtector supplies a right-angle, 2 AWG ground lug.) All lug fastener hardware is supplied. All outputs for breakers and returns are 2-pin, keyed (male) Molex connectors for site-prepared female connectors. Model 200QF8/8 conforms to all applicable NEC, UL, Bellcore, and NEBS III standards. Model 200QF8/8 is RoHS compliant. 3

Installation Manual DC Edge III PRODUCT SPECIFICATIONS Electrical Nominal Universal Voltage Range Operating Voltage Range Nominal Universal Voltage Range Operating Voltage Range DC Fault Rating Input Rating Input Interrupt Device Specification +24 Vdc to +48 Vdc +20 Vdc to +74 Vdc -24 Vdc to -48 Vdc -20 Vdc to -74 Vdc 10 ka 100 A per feed, max 125 A per feed, max Input Configuration Quad feed (Buses A1, A2, B1, B2) Input Wire Size Output Configuration Breaker Output Current Output Wire Size Alarms Indicators Alarm Relay Contacts Relay Contact Rating Bay Relay Activation Model 200QF 8/8 +24 Model 200QF 8/8 14 AWG to 2 AWG, depending on primary breaker rating Four breakers per bus (total of 16 positions) not to exceed total of 100 A output per bus and 30 A output per position. Blank covers provided for all breaker positions..1 to 30 A Carling Technologies or AIRPAX singlepole, hydraulic-magnetic, non-delay, slow-trip breakers (sold separately; see page 21 for breaker part numbers) 16 AWG to 10 AWG, depending on output breaker rating Power A1, A2, B1, B2 LEDs (4): green for power on; off for power off/failure Fuse Alarm LED (1): red for tripped breaker; off for normal operation CRT, MAJ, MIN LEDs (3) for critical, major, and minor bay alarms. LED lights on a bay alarm; CRT and MAJ LEDs are red, and MIN LED is amber Dry Form C for Power, Fuse, and Bay Alarm failures 220 Vdc, 220 Vac, 1 A 12 Vdc 4

Mechanical Input Terminals Output Load Terminals Specification Dual 1/4-20 studs on 5/8" centers. (Tongue width of lug must be no greater than.062".) Two-pin, keyed Molex 1 male connectors Ground Terminal Dual 1/4-20 studs on 5/8" centers. Transtector includes a 90 ground lug for a 2 AWG ground conductor. Alarm Terminals Rack Chassis Material Weight (out of box) Weight (shipping) Rack Chassis Dimensions (Nominal, Without Rack Mounting Brackets) 3 Rack Mounting Rear Panel Safety Two, 15-socket, standard, D-type connectors 2 16 gauge CRS, telecom grey powder coat. 11.5 lbs (5.2 kg) ~ 13 lbs (~ 6 kg) 1.72" H x 17.0" W x 9.0" D (44 mm x 305 mm x 229 mm) 1RU, 19" per EIA Standard RS-310-D 4. Mount flush to rack or extended up to 5" in 1 1/4" increments. Snap-in clear input (BATT and RTN) terminal covers, provided Environmental Storage Temperature Operating Temperature 5 Relative Humidity Specification 14º F to 149º F -10º C to 65º C 14º F to 131º F -10º C to 55º C 90% (non condensing) Approvals Standard UL 60950, File #E312258 NEC 800.100 & 830.100 NEBS-3V Compliant Environmental & Shock Material Safety GR-63-CORE, GR-1089-CORE, NEBS Level III RoHS compliant 1 Female terminals and connectors are not supplied. Order Molex Series 42815 (female terminals) and Molex P/N 428160212 (female connector) for output wiring up to 10 AWG. 2 Male connectors are not supplied. Typical D-type male connectors accept wiring in the range of 20 to 28 AWG. 3 See Page 23 for detailed dimensions. 4 Brackets are included for both 19 in. and 23 in. racks. 5 AIRPAX maximum operating temperature not to exceed 54ºC. 5

Installation Manual DC Edge III FACTORS AFFECTING INSTALLATION Elevated Operating Ambient If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by Transtector. Reduced Air Flow Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised. Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to the uneven mechanical loading. Circuit Overloading Consideration Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over-current protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Earthing Reliable earthing of the rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (for example, use of power strips). Disconnect Device A readily accessible disconnect device should be incorporated in the building installation wiring. 6

INSTALLATION PROCEDURE This product must be installed only by qualified personnel. Any service to this product must be performed only by qualified personnel. The product is intended for installation in a restricted access area. Only use tools (for example, crimping tools, dies) and components (for example, breakers and wiring connectors) approved by recognized agencies and authorities (for example, UL, TUV, NEC). Before connecting input power cables make sure input power to panel is turned off. Read and understand these instructions before installing this product. If necessary, contact Transtector for technical assistance: by phone at 1.800.882.9110 or 208.772.8515. Or email us at info@transtector.com. Hazardous Voltage. Multiple power sources may be available. Disconnect all power before servicing. Inspect Shipping Container 1. If damage is suspected, request that the carrier s representative be present during unpacking. Note: Transtector is not liable for damages incurred during shipping. Inspect Contents of Container 2. During unpacking, inspect panel for damage. If damaged, contact the carrier. Report details of damage to Transtector by phone at 1.800.882.9110 or 208.772.8515, or email us at info@transtector.com. 3. Check contents of accessory kit, as listed in the following table. If any items are missing, contact Transtector by phone at 1.800.882.9110 or 208.772.8515, or email us at info@transtector.com 4. If required, prior to fastening the 19 in. or 23 in. brackets to the panel, lightly coat the bracket s contacting surface between the bracket and the panel with an anti-oxidant. 5. Fasten 19 in. or 23 in. rack brackets to panel using supplied fasteners (eight, 10-32 cap screws and split lock washers). (See "Bracket Installation" on Page 9.) Torque fasteners to no greater than 23.7 inch pounds (~2.68 Newton meter). Note: Panel brackets provide flush front-face mounting or extended mounting up to 5 inch in 1 1/4 inch increments. 7

Installation Manual DC Edge III Accessory Kit Accessory Purpose Quantity Illustration Cap Screw 10-32 x 3/8" Bracket Installation 8 Lock Washer #10, Split Bracket Installation 8 Flat Washer #12 Installing Panel in Rack 4 Lock Washer #12, Split Installing Panel in Rack 4 Screw #12 Thread-Forming, Phillips Head Installing Panel in Rack 4 19 in. Mounting Bracket Rack Mounting 2 23 in. Mounting Bracket Rack Mounting 2 Transparent Cover Input Terminal Covering 2 Flat Washer 1/4" ID Input & Ground Connections 18 KEPS Nut 1/4-20 Input & Ground Connections 18 Two-Hole, Right-Angle Lug for 2 AWG Ground Connection 1 8

Blank Cover, Black Covering Unused Breaker Positions 16 Designation Card Recording Output Assignments 1 Figure 1: Accessory Kit Mounting Panel to Rack 6. Select a location for the DC Edge III panel on the rack. Choose to mount power panels at topmost or highest possible rack position. Figure 2: Bracket Installation Figure 3: Rack Installation Note: Panel weighs approximately 11.5 lbs (5.2 kg). Take care to support the panel when installing panel to rack. Two persons may be required in the following step. 7. Mount panel to rack using two sets of supplied fasteners per side (total of four 12-24 threadforming, Phillips-head screws, split lock washers, and flat washers.), as shown in "Rack Installation" above. Tighten screws to no greater than 35 inch pounds (~4.29 Newton meter). Torque Rating Chart Fastener Connections Maximum Torque (inch pounds) Maximum Torque (Newton meter) 12-24 35 inch pounds 4.29 Newton meter 1/4-20 55 inch pounds 6.2 Newton meter 9

Installation Manual DC Edge III Ground Wiring This product must be properly grounded to the facility s DC ground bus. Failure to do so is dangerous to personnel and may result in equipment malfunction. 8. Crimp 90 ground lug (supplied) to a 2 AWG stranded copper wire. One 2 AWG ground wire is the minimum requirement for four, 125 A interrupters feeding this panel. 9. If required, lightly coat anti-oxidant on contacting surface between ground lug and ground bracket. (The ground bracket is centered on the rear of the panel.) Figure 4: Ground Wiring 10. Fasten lug to panel using two, 1/4-20 KEPS nuts and flat washers all supplied. Tighten to no greater than 55 inch pounds (~6.2 Newton meter). Inputs Check that input power to panel is off or disabled before installing input cabling. 11. Remove input terminal covers shown in the previous illustration. 10

12. Slip UL94 V-0 heat-shrink tubing over the ends of 14 AWG to 2 AWG stranded copper input wires. Note: Although the A1 and A2 RTN buses, as well as the B1 and B2 buses, are shared, Transtector recommends separate RTN leads for each active bus, even if those shared buses have a shared primary distribution unit. 13. Use approved tooling to crimp straight, 45º, or 90º dual-hole compression lugs (1/4 inch holes on 5/8 inch centers) onto ends DC Edge ends of input wiring. 14. Use a nonabrasive, nonmetallic pad, such as Scotch-Brite, to clean input terminals and lugs. 15. Heat shrink UL94 V-0 tubing onto lug barrels. 16. If required, lightly coat anti-oxidant on contacting surfaces between input lugs and BATT and RTN input terminals. 17. Fasten lugs to BATT and RTN input terminals using supplied hardware (two 1/4-20 KEPS nuts and flat washers per terminal). Tighten to a maximum of 55 inch pounds (~6.2 Newton meter). Figure 5: Connecting Input Wiring 18. After connecting inputs, re-install transparent covers over input terminals. Transparent covers are labeled for Side A and Side B. Figure 6: Installing Input Terminal Covers 11

Installation Manual DC Edge III 19. Use the four dip switches on the alarm board to enable/disable bus LEDs and alarms, as follows: A. As shown in the following illustration, remove two Phillips-head screws securing alarm board to front of panel. B. Pull out alarm board about 2 inches. C. Slide a dip switch (A1, A2, B1, B2) to the left to enable (EN) status and alarms for the corresponding bus. The dip switches enable/disable the power LEDs on the front of the panel and the power alarm contacts on the rear. The dip switches do not enable/disable the buses, meaning that, if a dip switch is set to disable, the corresponding bus can still be used to power its set of four breakers. The problem lies in having a non-indicating power LED for that bus and a non-indicating power alarm. Figure 7.1: Accessing Bus Status & Alarm Switches Figure 7.2: Enabling Bus Status & Alarms Test Voltages & Alarms 20. Make sure all DC Edge III breaker positions are empty (unpopulated). 21. Turn on or enable fuse, breaker, or other disconnect device to feed power to one of the selected buses. 22. Test voltage and polarity at input terminals of that bus. Also, expect that Status LED for that bus is lit (green), and All other LEDs are off. Figure 8: Status & Alarm LEDs 12

23. Test continuity between power alarm terminals: Figure 9: Upper and Lower D-Connector Alarm Terminal Upper D-Connector Pin-Outs Pin Assignment 1 Power Alarm NC 2 Power Alarm NO 3 Power Alarm C 4 Major Reference 5 Major NO 6 Major C 7 Major Activate 8 Major NC 9 Fuse Alarm NC 10 Fuse Alarm NO 11 Fuse Alarm C 12-15 unused 13

Installation Manual DC Edge III Lower D-Connector Pin-Outs Pin Assignment 1 Minor Reference 2 Minor Activate 3 Minor C 4 Critical Reference 5 Minor NO 6 Minor NC 7 Critical Activate 8 Critical C 9 Critical NC 10 Critical NO 11-15 unused If the bus that was turned on in Step 21 is the only bus enabled in Step 19 Expect continuity (0 Ohms) between power terminals C and NC; Expect an open circuit ( ) between C and NO. Note: Normal conditions, that is, normally open (NO) and normally closed (NC), are for a normally functioning panel with power on and no tripped breakers. If any other presently unpowered buses were enabled in Step 19 Expect an open circuit ( ) between power terminals C and NC; Expect continuity (0 Ohms) between C and NO. 24. For FA (fuse alarm) terminals Expect continuity (0 Ohms) between C and NC; Expect an open circuit ( ) between C and NO. 25. Repeat Steps 20 through 23 for each powered/enabled bus. Expect that the corresponding power LED turns green and that the power alarm terminals exhibit normal continuity/open status: namely, Expect continuity (0 Ohms) between power terminals C and NC; Expect an open circuit ( ) between C and NO. 14

Outputs 26. For panel outputs, crimp stranded copper output wiring (16 to 10 AWG) onto Molex terminals (Molex Series 42815) for use in Molex 2-position, single-row female connectors (Molex Part No. 4281680212). Female terminals and connectors are not supplied. The male connectors on the panel are Molex Part No. 428180212. The size of output conductors depends on current rating of output circuit breakers to be installed in panel. Note: Be aware that the top and bottom rows of output connectors on the rear of the panel are reversely oriented, as shown in the following illustration. The BATT output (±24 V, -48 V, etc.) is always on the left on the top row, when viewed from the rear, and the BATT output is always on the right on the bottom row. Figure 10: Output Connector Orientation 15

Installation Manual DC Edge III 27. Crimp female terminals on output wires, install terminals in female connectors, and insert female assemblies into male connectors on panel. The following illustration shows output connections for Breaker 3 on Bus A1 and Breaker 7 on Bus A2. Figure 11: Connecting Output Wiring 28. Use cable ties or lacing cord to fasten the first pair of output conductors to the near-rear corner of the rack. 29. Continue with the next pair of output conductors - tying off that pair to the previous pair. Figure 12: Output Cable Management 16

30. Connect opposite ends of output conductors to the output loads. 31. Turn off or disable fuses, breakers, or other disconnect devices feeding power to Sides A and B of the DC Edge III panel. Note: The following steps deal with breakers. Good practice involves turning off power to one side or the other of this panel when installing or replacing breakers. When that is not possible, rely on and follow established operating company or regulatory practices. However, NEVER install breakers in a live circuit with the operator handle switched on. 32. Remove blank cover over selected breaker position. Pull the handle of the blank cover to remove. See Breaker Replacement on Page 21. 33. During installation of breakers, make sure that circuit breakers are switched off. 34. Install circuit breakers (off) 1, as shown in the following illustrations, with ON at the top and OFF at the bottom. Figure 13: Installing Circuit Breaker 1 For proper alarm relay operation, ensure that the alarm contact tabs are not bent or deformed prior to inserting into the panel. 17

Installation Manual DC Edge III 35. When installing breakers, record the ratings and position on the designation card shown in the following illustration. Insert card into pull-out holder below LED panel. Figure 14: Designation Card 36. Disable DC Edge III output loads at the equipment loads. 37. Turn on output breakers. 38. Turn on or enable fuses, breakers, or other disconnect devices to feed power to all DC Edge III buses. 39. Expect that the enables power LEDs are on (green) and all other alarm LEDs are off. 40. Turn off one of the breakers. Expect that the FA (fuse alarm) LED is on (red). Check the FA (fuse alarm) terminals on the rear of the panel. Expect: An open circuit ( ) between C and NC, and Continuity (0 Ohms) between C and NO. 41. Make sure all breakers are on. 42. Test power and polarity at the input of each output load. 43. Enable DC Edge III ouput loads at equipment loads. Check loads for proper operation. Alarms 44. If required, connect panel and/or bay alarm wires to the two, D-type connectors on the rear of the panel. 18

MAINTENANCE DC Edge III panels require no scheduled maintenance. BREAKER REPLACEMENT Circuit breakers are held in place by wide plastic barbs at the top and bottom of each breaker. The barbs lock into cutouts in the top and bottom of the two breaker cages. Transtector provides two breaker removal tools. The tools are used together to facilitate breaker removal by depressing the barbs while prying out the breaker. In use, slip one tool between the top of the DC Edge III panel and the bottom of the panel above so that the hooked end of the tool slips into the cutout above the breaker. Insert the other tool in the corresponding position at the bottom of the panel. Then pry up on the top tool and down on the bottom to unlock the barbs and free the breaker. Figure 15: Removing a Breaker 19

Installation Manual DC Edge III ALARM BOARD REPLACEMENT The alarm board (Transtector Part No. 2250-949) along with the status LEDs can be replaced with power on. The alarm board rests on slides and is edge connected at the far end. To replace the alarm board, refer to the following illustration and remove two Phillips-head screws. Then, pull to disconnect and slide out the alarm board. If installing a replacement alarm board, use a 5/64" Allen wrench to remove the button-head socket screws holding the faceplate to the alarm board. Retain the screws and faceplate for installing the replacement board. Torque screws for replacement board to 6 in-lbs. Slide the alarm board back into the chassis through the plastic guide rails. Ensure the board is fully seated in the edge connector. Secure the Phillips-head screws and torque to 4 in-lbs. Figure 16: Removing Alarm Board SERVICE For service (warranty or otherwise) contact Transtector by phone at 1.800.882.9110 or 208.772.8515, or by email at info@transtector.com to obtain an RMA number. Transtector will contact you with cost of repair or replacement (if applicable) before proceeding with service. 20

CIRCUIT BREAKERS The DC Edge III panel uses single-pole, Carling Technologies M-Series or AIRPAX SNAPAK series hydraulic magnetic circuit breakers with on/off rocker operators. All circuit breakers are slow-trip without mid-trip: Rating Carling Technologies Part Number AIRPAX Part Number 0.1 A MA1-M-14-210-1-A16-2-J CR15-52-.100A-R06CV-V 0.5 A MA1-M-14-250-1-A16-2-J CR15-52-.500A-R06CV-V 1 A MA1-M-14-410-1-A16-2-J CR15-52-1.00A-R06CV-V 2 A MA1-M-14-420-1-A16-2-J CR15-52-2.00A-R06CV-V 3 A MA1-M-14-430-1-A16-2-J CR15-52-3.00A-R06CV-V 4 A MA1-M-14-440-1-A16-2-J CR15-52-4.00A-R06CV-V 5 A MA1-M-14-450-1-A16-2-J CR15-52-5.00A-R06CV-V 7.5 A MA1-M-14-475-1-A16-2-J CR15-52-7.50A-R06CV-V 10 A MA1-M-14-610-1-A16-2-J CR15-52-10.0A-R06CV-V 12.5 A MA1-M-14-712-1-A16-2-J CR15-52-12.5A-R06CV-V 15 A MA1-M-14-615-1-A16-2-J CR15-52-15.0A-R06CV-V 20 A MA1-M-14-620-1-A16-2-J CR15-52-20.0A-R06CV-V 25 A MA1-M-14-625-1-A16-2-J CR15-52-25.0A-R06CV-V 30 A MA1-M-14-630-1-A16-2-J CR15-52-30.0A-R06CV-V 21

Installation Manual DC Edge III LUGS (1/4 on 5/8 Centers) A right-angle, 2 AWG dual-hole ground lug is included with the DC Edge III panel. For input wiring, only use one of the following straight lugs. Crimp lugs to wire terminations with supplier recommended crimp tool. Lug Style Wire Size Burndy Part No. Panduit Part No. Straight 14-10 AWG YAV10-2TC14 8 AWG YA8CL-2TC14 LCD8-14A-L 6 AWG YA6CL-2TC14 LCD6-14A-L 4 AWG YA4CL-2TC14 LCD4-14A-L 2 AWG YA2CL-2TC14 LCD2-14A-Q 22

DIMENSIONS Figure 18: Dimensions 23

Installation Manual DC Edge III Transtector Systems Transtector Systems specializes in the protection of highly sensitive, low voltage equipment through its patented, non-degrading silicon diode technology and custom filters. Its power quality expertise translates into a diverse product offering including AC, DC, and signal applications as well as integrated cabinets, power distribution panels and EMP hardened devices. Smiths Power Smiths Power is a leading supplier of power distribution, conditioning, protection and monitoring solutions for data centers, wireless communications and other critical or high-value electrical systems. As a family of brands, PDI, Onyx, PolyPhaser, Transtector, DOWIN, LEA and RO Associates unite under one umbrella to Transform, Distribute, Monitor and Protect power in global networks and systems. Our companies provide expertise in consulting, design and manufacturing of power transformers and distribution systems, static switching, power monitoring, RF, AC, DC, data signal and EMP protectors as well as power quality engineering services. Alongside Smiths Connectors and Smiths Microwave, Smiths Power is part of the Smiths Interconnect division of Smiths Group (www.smiths.com), a global leader in applying advanced technologies for markets in threat and contraband detection, energy, medical devices, communications and engineered components. Smiths Group employs around 23,000 people in more than 50 countries. Transtector assumes no liability in the ose of this product. Transtector conveys no license under its patent rights or those of others. Transtector reserves the right to change this product and this publication without notice. Transtector Systems, Inc. 10701 Airport Drive, Hayden, ID 83835 800.882.9110 +1.208.772.8515 FAX 208.762.6034 24