FTTHARCFUSIONSPLICER AD620

Similar documents
USERS MANUAL EasySplicer

Introduction. Disclaimer. Application. EasySplicer components

QUALITY CABLE & ELECTRONICS, INC.

PRO-810. Fusion Splicer. Operation Guide

USERS MANUAL EasySplicer

Fujikura-70S Single Fibre Fusion Splicer

User Manual. Optical Fiber Fusion Splicer O F S 95 PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE OPERATING THE EQUIPMENT.

View 3 User Manual. ARC Fusion Splicer. Please read this manual before operating your fusion splicer, and keep it for future reference.

Sumitomo T-39 Core Aligning Fusion Splicer

Instruction manual. FOFS Cougar. Optical fiber fusion splicer. Please read through this manual completely. before its first use.

FIBER FUSION SPLICER OPERATION MANUAL

IFS-15H User Manual. ARC Fusion Splicer. Please read this manual before operating your fusion splicer, and keep it for future reference.

SUPER COUGAR CORE ALIGNMENT FUSION SPLICER INSTRUCTION MANUAL

Optical Fiber Arc Fusion Splicer. Read this user manual carefully before running FX Fusion Splicer. FX Fusion Splicer USER MANUAL. PX EN, Rev.

INSTRUCTION MANUAL 915FS. Optical Fiber Fusion Splicer. Register this product at

Ribbon All In One Fusion Splicer

User Guide. T-25S-L (Coating Clamp) T-25U-L (Coating Clamp)

User Manual SWIFT S5. Optical Fiber Arc Fusion Splicer. Read this service manual carefully. before running S5.

User Manual SWIFT R5. Optical Fiber Arc Fusion Splicer. Read this service manual carefully. before running R5.

OFS-950S/950R. Fusion Splicer. Operation Guide

Core Alignment All In One Fusion Splicer

Advancing Fiber Optic Connectivity

Fusion Splicing Recommendations for OFS Rollable Ribbon Using the Fitel S123 M12 Fusion Splicer

Optical Fiber Arc Fusion Splicer. Read this user manual carefully before running K11. SWIFT K11 USER MANUAL

OFS-920. Fusion Splicer. Operation Guide

Ensuring Cabling Performance in the Customer-Owned Outside Plant

New Mass Fusion Splicer FSM-50R Series

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

FTTc Network Testing Overview

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

OME Core Alignment Fusion Splicer Z1C. Guide to operation

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

FITEL S179 Fusion Splicer Hand-Held, Core Alignment Fusion Splicer

MULTIFUNCTION ROBTIC AUTO VACUUM CLEANER. MODEL NO.: M-788 Auto Charging With Remote Controller, Mop And UV Lamp

AE2200 FTTx Multi-Function Meter

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

M700-Series Multifunction OTDR

Fiber Optics for Todays Industry Applications

Fiber Optic Products Catalog

OPTICAL FIBER IDENTIFIER OFI-BIPM

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Noyes OFL 250B Specs Provided by

Savitri Telecom Services

FHO5000 Series Triple-Proof OTDR

Grafisk Maskinfabrik A/S Bregnerødvej 92, DK-3460 Birkerød, Denmark. Website: Phone:

Operations Manual. Part Number: For Research Use Only

Thermal Stripper, TSFB-125 User Manual

HDCVI PIR Camera User s Manual

Dryer Controller M720

User Manual. Dryer Controller M720

Visit us at testo 835 Infrared and contact thermometer

30-YEAR LIMITED WARRANTY

CEILING FAN OWNER'S MANUAL

USER MANUAL myvacbot SN500 Robot Vacuum

WARNING. 1.Warnings and Cautions for Safe Operation. Page 1 Page 2

MOBILE CALL GSM Alarm System User s Manual

The FTA-02 Fiber Arranger

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

DGC-500 DIGITAL GENSET CONTROLLER

HDAVS ICR IR Water proof Dome Camera User s Manual

CEILING FAN OWNER'S MANUAL

AV6419 BOTDR. Product Overview. Main Features

KF-250 Knife Folding Machine

Thermal Stripper, TSAB-40 User Manual

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

OPTICAL FIBER JOINTS & CONNECTIONS

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

RS Pro Infrared Temperature Sensor

SIMPLE WIRED REMOTE CONTROLLER

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

USER S GUIDE WATER HEATED AIR CURTAINS

MT-RJ Optical Fiber System Field Testing

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

THERMAX Efficiency Monitor

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

4120 Fire Alarm Network Reference

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

The True Value of Connector Inspection: New Challenges and Best Practices

SmarTemp Control fx 2.0

packagingconnection.com Div. of Express Worldwide, Inc.

Hands-On CAT 5/6 & Fiber Optic Installer

USER S GUIDE. ecal lite Software Access Code included! SUBSECTION. Read Guide Before Operating Product. Save Guide For Reference.

MINI2 MOST ACCURATE COMPACT OTDR

Datasheet Palm OTDR. Product Summaries

MD-6 METAL DEFENDER MANUAL, TECHNICAL SPECIFICATIONS

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

FMJ-1600-II-WARM Ving 63" Full - auto Wide Format Roll Heat Assisted Cold Laminator with Stand USER MANUAL

CEILING FAN OWNER'S MANUAL

CLASSIC PLUS INFRARED ZONE HEATER

High cost performance choice

A4 Manual Book. No. 15 Airport South Road, Jiaojiang District, Taizhou, Zhejiang, TEL: FAX:

ACCESS Master MT9085 Series. Product Introduction

Transcription:

FTTHARCFUSIONSPLICER AD620 Read this instruction manual carefully before operating the equipment. Adhere to all safety instructions and warnings contained in this manual. Keep this manual in a safe place.

Content 1. Introductions... 2. Specifications... 3. Description of operation units... 4. Description of software menu... 5. Switch on, switch off and Stand by of Machine... 6. Basic procedure of splicing... 7. Charging of Machine... 8. Standard package... 9. Safety Operational Norms... 10. Warnings and Cautions for transportation... 11. Periodical replacement of components...

1.Introductions It is a light weight, small and fast FTTH Fusion Splicer, which is designed to splice bare fiber, pigtail, patch cord, Optical fiber drop cable and make of SC,FC, LC connector on the spot by changing different fiber holders equipped. It is an ideal tool for the splicing of fiber network terminal, which is able to work in narrow and small room. Picture as follows:

2.Specifications Applicable fibers: SM, MM, DS, NZ-DS, G655,G657 and others Fiber Diameter:Cladding Diameter: 80-150 μm; Coating Diameter: 100~1000 μm Splice Time:8Sec. Average splice loss:0.01db(mm) 0.02dB(SM) 0.04dB(DS/NZDS/G.655/G.657) Return loss: 60db Tension test: 2.0N Protection sleeve length: 25mm/40mm/50mm Tube-heat Time: 35 seconds Splicing program: Parameter modifiable Alignment: Core Alignment Language: English and Spanish (Other language optional) Fiber Holder:Replaceable and Suitable for the Splice of bare fiber,pigtail,patch cord, Optical fiber drop cable and SC,FC,LC connectors Display: Color 3.5 Inch TFT Magnification: 220 Interface: USB/Uart, suitable for data download and software update Splice Memory: 10000 Operating Temp: 15 ~+50 Storage Temp: 40 ~+80 Window Protection: Max. wind velocity of 15m/s DC output: 12V/2A Power for external heater, light or hot jacket stripper Internal Battery: 12V/6Ah, more than 120 times of continuous splices and heats Dimension: 120mm(L)*120mm(W)*115mm(H) Weight: 1.7KG (Include battery

3.Description of operation units Panel and Wind Protector 1:Wind Protector Magnet 2: Wind Protector 3: Electrode Cover Plate 4: Holder Base 5: Electrode 6: Key Board 7: light 8: Fiber Presser 9: Heating indicator light 10: Electrode Base 11: V-Groove 12: Alignment wheel Description of side outlet box: 1: Charging input port 2: USB interface 3: DC output port Key board: : Menu/Confirm : Exit/Return : Up Down/Modify : Splice/Re-arc : Heating : Reset : Switch

4.Description of Software Menu There are 6 pages of the software menu: function selection, parameter set, maintenance set, record check and operation guide, description of subpage is as follows: Arc Test: By doing Arc Test, it will judge whether the current arc power is suitable for the fiber and environment or not. Prepare fiber, place the fiber in the V-groove, choose arc test and then enter arc test program, and there will be a report after the arc test finished. If it shows arc strong or arc weak, the machine will automatically adjust arc power to make the following arc test to be arc ok. Performing Arc test is a very important method to keep the machine at a well working condition. Arc test has to be performed in the following situations to avoid bad splice: Replace of electrode Dramatic change of temperature, humidity and air pressure Different fibers to be spliced Several times use of Electrode Splicing db loss high without reason Distortion of fiber image after splicing Cleaning arc time: There is a transient arc for cleaning the fiber after fiber is pushed into the screen, it can be modified by this program. Splicing mode select: There are 7 modes can be selected:sm,mm50,mm62.5,ds,nzds,erbium,user DEFINE, the specific parameter of the splicing parameter menu will be changed accordingly. Tension Test set: After open the wind protector, the machine will tension test or not based on this set. Heating time: Heater will heat according to the time set after pressing the heat button. Pressing heating button during heating operation, it will stop heat. Auto start set: If this item is OPEN, after close the cover in stand by status, the machine will start splice automatically. Parameter Set I; Arc power: This parameter has the function over cleaning arc, pre arc, splicing arc, arc again, it can be set from 10-100.

Pre arc time: it is time between the start of arcing and start of forward. Arc time: it is the continuous arc time after forward. Overlap length: the forward length during arc process. Arc again: After splicing, pressing arc button, the machine will arc again. Angle threshold: During splicing process, if the fiber angle is greater than this parameter, PAUSE Ⅰ will be automatically started (Even if PAUSE Ⅰ is in off condition). Note: Changing arc power and arc time has an affect on arc test result. Parameter set Ⅱ: Push speed: it decides motor speed and reset speed. Alignment gap: the distance between the end face of left and right fiber after aligned. Gap position: the position of end face after fiber aligned, it is set in the mid of the screen usually. When the arc position is not in the mid of the screen (can be verified by the result of arc test), this parameter can be modified to make the gap position and arc position stay in same. Alignment offset: If the alignment offset is greater than this parameter, PAUSE will be automatically started (Even if PAUSE is in off position). PAUSE : If this item is open, during the process of splicing and arc test, the fiber will stop after pushed into screen. PAUSE: If this item is open, during the process of splicing and arc test, the fiber will stop after alignment. Maintenance Set: Lens check: Check whether there is dust or saturation points in lens, by this check result, it can judge if the optical system of this machine suitable for splicing operation or not. Motor resetting position: the distance that motor left the initial position after switch on or resetting. Day setup: Set year, month and day. Clock setup: set hour, minute and second. Parameter resume: resume all parameters to default value.

Language: Chinese or English. Records check: Arc times: arc times of electrode, including arc test, splicing arc, splicing again and manual splicing. Arc times clear: Recommend to do this operation after changing of electrode. Heat times: working time of heater. Heat times clear: recommend to do this operation after changing of heater. Records view: view the operation record of this machine, including splicing time and splicing result. If the splicing loss is 2.55, that means splicing failed. Records clear: clear all splicing records, maximum records are 10000(0000-9999). Operation guide: It is a simple operation guide, red by pressing page-turning key. 5.Switch on, switch off and stand by Pressing switch will power on the machine In stand by, pressing switch continuously, machine will buzz, when buzzing stopped, still pressing the switch button, the machine will power off once loosing the switch button. Stand by:

Stand by after power on, and it will show the current day, time and battery capacity and available operation button. 6.Basic procedure of splicing One: Prepare fiber 1. Drop Cable -Place drop cable into stripper to 30mm position and strip drop cable coat by 30mm -Strip fiber coating by CFS-2 Stripper and retain 3mm -Clean fiber -Place the cleaned drop cable to the drop cable holder -Please the holder to AD-105H Fiber Cleaver for cut

-Cutting finished Stripping diagram: 2: Splice-on Connector A.Connector which need strip -Strip fiber protective layer by CFS-2 Stripper and retain 1 mm -Clean fiber -Place the cleaned fiber to the fiber holder Place connector locating pin into holder front slot

Place connector locating pin into holder back slot - Place the holder to AD-105H fiber cleaver for cut - Cut finished Stripping diagram: B. Connector which already cut a. b.

3. Pigtail - Strip pigtail jacket by CFS-2 and retain 30mm -Cut lines -Strip fiber coating by CFS-2 Stripper and retain 5mm -Clean fiber -Place the cleaned fiber to fiber holder - Place the holder to AD-105H Fiber Cleaver for cut - Cut finished

Stripping diagram: 4. Bare Fiber -Strip fiber by CFS-2 fiber stripper and retain 30mm -Clean the fiber -Place fiber to fiber holder -Place the fiber holder to AD-105H fiber cleaver for cut -Cut finished Stripping diagram:

Two: Place fiber After fiber cutting, continue the following operations Open wind protector, uplift fiber presser foot. Place the holder with fiber in side to the holder base, make sure fiber is in V-groove. Put down fiber presser foot softly, and close wind protector. Press splicing button Three: Alignment adjustment If fiber core shift bigger than the threshold set, splicer will stop splice and wait for manual adjustment Core alignment manually by adjusting the wheel, during adjustment, offset data will keep decreasing, splicer will beep when core alignment succeed Before adjustment After adjustment Four: Heating operation Open wind protector, take out spliced fiber.(for drop cable, please use the professional tool to take out the fiber) Press reset button for next splicing (If necessary) Move the protection sleeve to cover the splicing point Put fiber in heater

Press heating button Splicing and heating finish Need to change the left-side base of the heater if heat drop cable or splice-on connector 7.Charging of Machine The fusion splicer is equipped with the dedicated charger, other chargers are not allowed. It can be charged when power on or power off Red indicator light mean fusion splicer is under charging, green mean charge fully. 8.Standard package and optional 1 Fiber cleaver 2 drop cable stripper 3 Stripper 4 Holder (Multiple) 5 Electrode 6 Cooling tray 7 Charger 8 Fiber take- out tool 9 Instruction Manual 9.Safety operation Norms 1. Prohibiting to using fusion splicer in the environment with inflammable explosive liquid or gas, otherwise electrode arc may cause fire or explosion. 2.Do not operate machine if there are moisture condense on the machine, otherwise the machine will be damaged. 3. Avoid strong shock or crash, because the mechanical components were precisely adjusted and aligned, otherwise damage will be caused, make sure use the equipped carton to store or transport the machine.

4. Do not use any other chemicals but alcohol to clean lens, V-Groove, holders, LCD monitor etc., otherwise it will cause blurred imaging, dirt, damage, corrosion. 5. Do not touch electrode while fusion splicer is working, otherwise the high pressure and temperature generated by electrode will cause electric shock and burn. Switch off fusion splicer while changing electrodes. 6.Do not dismantle fusion splicer and charger. 7.Only use the equipped charger to charge battery, otherwise may cause damage to fusion splicer and operators. 8.Switch off fusion splicer, in case liquid (water) or other external stuff (screw) entered the machine, otherwise damage to the machine will be caused. 9.Take out fiber carefully after heating finished, do not touch the protection sleeve and heater, since the high temperature will cause burn. 10.Only electrodes supplied by manufacturer can be used. 11. Repair and adjustment can only be operated by the professional technician or engineer, improper repair may cause fir and electric shock. 10. Warnings and cautions for transportation Avoid strong shock or crash, because fusion splicer is precision instrument and the mechanical components were precisely adjusted and aligned, otherwise damage will be caused, make sure use the equipped carton to store or transport the machine. Do not put fusion splicer in a unstable or unbalanced position, otherwise fusion splicer may be damaged in case the fusion splicer loose balance. 11. Periodical replacement of component. 1 Replacement of electrode Power off fusion splicer loss the two screws which fastening the cross-shaped slot take out electrode cover and screws take out electrode Change new electrodes, and put the end face of the plastic top of the electrode on the copper plate. Pressing electrode by electrode cover, tighten two screws, there should be a 0.1mm gap between electrode cover and copper plate once screwed, do not make over deformation of the electrode cover. Repeat 1~5 to change another electrode. 2 Replacement of heater Switch off fusion splicer, cooling heater to room temperature Open left and right plate Dismantle two M2.5 screws by allen wrench. Take off heater softly and pull off power plug Change a new heater, plug the power line Tightening heater to fusion splicer panel by two M2.5 screws