How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

Similar documents
FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2

FAST-STAT. Wiring Extenders

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

FAST-STAT Nordic Electronics Ltd

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

HEAT HEAT HEAT COOL COOL

Model CZ-4. Installation and Operating Instructions. FORM White-Rodgers by Permission B

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

Fresh Air Ventilation Kit

7-Day. Digital Thermostat. residential. & 2-cool

Installation Instructions HEAT COOL FAN POWER

Common Maker Troubleshooting

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins

Installation and Operating Instructions

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

Design & Installation for. Zonex Systems. System Zone Auto Changeover. System Zone Manual Changeover

asy Single Day up to 2-heat & 2-cool Stat

Erie WA300. Application. Features. Two Zone Hydro-Air Relay General Instructions

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

GLAS. Installation Instructions

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

Troubleshooting the Indoor AHU as a Standard Product

Model 1730A Compact Dehumidifier Installation Instructions

Note the wire colors and letter designations of the existing thermostat to assist in identifying the correct wiring connections to the TS200.

H32 Uni- Zone Model H32

Smart Si Thermostat. Installation Manual

Installer : Save these instructions for future use!

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON

Install Guide CT100. Caution. Caution

ACCESSORY KIT INSTALLATION MANUAL

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

ZONE 2 MOTOR SW2 OPEN M6 M4 M2 M1 CLOSED ZONE 1 MOTOR SW1 OPEN M6 M4 M2 M1 CLOSED 24V T'FORMER 2 CB1 SYSTEM B GHC R CONTROLS INC.

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

Install Guide 3M-10 ENGLISH

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

18 SEER IDS Inverter Ducted Split

Z24 Wireless Zone Controller Professional Installation Guide

Digi-Zone Model MDP3 Ver.04

HV to HE Conversion Kit Installation

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

Installer : Save these instructions for future use!

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

EWT-955WH. Wireless Type Selection. Installation Manual. Installation Tips. Installation Tips

Commercial Zoning Guide

Installer : Save these instructions for future use!

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. September 2016 Version 7

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

INSTRUCTION MANUAL. PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch 3-YEAR WARRANTY

Safety & Installation Instructions

Commercial Thermostat Submittal Data

User s Information/Installation Instructions

Install Guide Customer Support: or Visit our website

Digi-Zone. Installation and Operating Instructions. Model MDP3. Controlling Your Comfort Room By Room

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

Mx-MTB HVAC Controller

Installation Instructions / User s Manual NAXA00101DB Communicating Daughter Board

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

Install guide 8010 ENGLISH. Customer Support: or Visit our webiste Made in China

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

ACCESSORY ITEMS FOSSIL FUEL KITS RXPF- SERIES. Model RXPF-F01 Model RXPF-F02

ZIGBEE COMMUNICATING THERMOSTAT

Safety & Installation Instructions

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7

G Series Geothermal Indoor Split Heat Pump R-410A Refrigerant 2-6 Tons Single Speed 2-6 Tons Dual Capacity

Premier 2-Zone Controller model Installer Guide

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

io-fav-08 FRESH AIR VENTILATION

H o m e G e n e r a t o r S y s t e m s

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Install guide 8035C ENGLISH Printed in China MENU PROG RESET MENU PROG RESET

INSTALLATION AND OPERATION INSTRUCTIONS 303, 304, 305, CRH, CRQ, CFA SERIES 2250 WATT MODELS

Installation Instructions

Advanced Installation and Configuration Instructions

Safety & Installation Instructions

T-32-TS Touchscreen Thermostat. Installation Manual

Incutrol/2 Regulator

TECHNICAL GUIDE. Echelon MODELS: FC9M*UP GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW MODULATING FURNACES

FOR SERVICE TECHNICIAN S USE ONLY

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

Commercial Thermostat

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Models: RCI-1.0FSN3, RCI-1.5FSN3, RCI-2.0FSN3 and RCI-2.5FSN3 with Air Panel P-AP160NA x 32 Holes (for Suspension Bolt)

Safety & Installation Instructions

Technical data DHP-R. A brine-to-water building heat pump in power outputs

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Installation. Table of Contents. 1. Description/ Application. Form I-CAUA-CC (04-15) Obsoletes Form I-CAUA-CC (Version C.1)

LuxPro Thermostats NEW MULTI-STAGE TOUCHSCREENS. Features & Programming. Mt. Laurel, NJ

INSTALLATION MANUAL AFFORDABLE RENEWABLE CLEAN ASTON SERIES OUTDOOR SPLIT HEATING COOLING HOT WATER.

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

FOSSILFUELKITAXWR02FFA1

Transcription:

Nordic Technology Ltd 1-800-775-4750 www.fast-stat.com This is the printer-friendly edition. o to www.fast-stat.com to download and print additional copies HVA iring Solutions How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables. ontents eneral Instructions...... 1 Air onditioning Adding A/ to a heating system as furnace with built-in fan relay... 2 as furnace without built-in fan relay... 2 Oil furnace with built-in fan relay...... 3 Oil furnace without built-in fan relay...... 3 onverting from single to 2-stage A/ Adding wires between the indoor and outdoor units... 4 Adding wires between the t-stat, indoor & outdoor units... 4 Pumps onverting from an air conditioner to a heat pump Adding wires between the indoor & outdoor units... 5 Adding wires between the t-stat, indoor & outdoor units... 5 Adding wires between the thermostat & indoor unit... 6 Furnaces Installing a 2-stage furnace with a single-stage A/... 6 Installing a 2-stage furnace with 2-stage A/... 7 Installing a furnace with a modulating gas valve... 7 oof Top Units & PTA s... 8 s Adding manual fan control with a 2-wire thermostat cable... 8 Installing a powered thermostat with a 4-wire thermostat cable... 9 Installing a powered thermostat with a 2-wire thermostat cable... 9 iring for an outdoor air temp sensor... 10 able epair Example... 10 epairing ables How to test a cable... 11 How to repair a cable... 11 How orks Model 1000... 12 Model 3000... 12 Model 5000... 13 Model 7000... 13 Model 9000... 14 Frequently Asked Questions... 14 Note: e reserve the right to make changes & corrections without notice. Every effort has been made to provide accurate technical & product information. The company disclaims responsibility for any error or omission regarding technical & product information published.

eneral Instructions hen used at a thermostat, the wires are connected to the thermostat and thermostat cable. The is inserted into the wall space behind the thermostat. The thermostat is then mounted to the wall. as usual. The eceiver is installed at the indoor or outdoor unit. It is then connected to the thermostat or condenser cable and the control board. Page 1

Air onditioning as furnace with built-in fan relay Project: Adding a single-stage air conditioner to a heating system with a 2-wire thermostat cable. Solution: Use a Model 3000 to make a 2-wire thermostat cable into a 4-wire cable. able eceiver 3000 Details: Install the into the wall space behind the thermostat. onnect 2 wires from the to the thermostat cable and the other 4 wires to the thermostat. Install the eceiver in the indoor unit near the control board. onnect 2 wires from the eceiver to the thermostat cable, 2 wires to transformer power ( & ) and the remaining 3 wires to the fan (), condenser () and heat () connections. ompressor Outdoor Unit Air onditioning as furnace without built-in fan relay Project: Adding a single-stage air conditioner to a heating system with a 2-wire cable. Solution: Use a Model 3000 to make a 2-wire thermostat cable into a 4-wire cable. A fan center and a relay are required for this installation. able eceiver 3000 Details: Install the fan center according to the manufacturer s instructions. Install the into the wall space behind the thermostat. onnect 2 wires from the to the thermostat cable and the other 4 wires to the thermostat. Install the eceiver in the indoor unit. onnect 2 wires from the eceiver to the thermostat cable, 2 wires to the fan center transformer power ( & ) and 2 wires to the fan center fan () & condenser () connections. The eceiver white wire is connected to a relay. The relay is used to control heat (). The relay is used to isolate the two transformers from each other. The 120 volt wiring for the fan is not shown see the fan center instructions. elay ompressor Outdoor Unit enter Page 2

Air onditioning Oil furnace with built-in fan relay Project: Adding a single-stage air conditioner to a heating system with a 2-wire cable. Solution: Use a Model 3000 to make a 2-wire thermostat cable into a 4-wire cable. A relay may be required for this installation. able eceiver 3000 Details: Install the into the wall space behind the thermostat. onnect 2 wires from the to the thermostat cable and the other 4 wires to the thermostat. Install the eceiver in the indoor unit near the control board. onnect 2 wires from the eceiver to the thermostat cable, 2 wires to transformer power ( & ) and 2 wires to the fan (), condenser () connections. Install a relay and connect the eceiver white wire to it. The relay is used to complete the circuit between the T1 & T2 terminals on a call for heat. If the furnace has one terminal instead of 2 T terminals then the relay is not required and the white wire is then directly connected to the terminal. ompressor elay T T Outdoor Unit Air onditioning Oil furnace without built-in fan relay Project: Adding a single-stage air conditioner to a heating system with a 2-wire cable. Solution: Use a Model 3000 to make a 2-wire thermostat cable into a 4-wire cable. A fan center and a relay are required for this installation. able eceiver 3000 Details: Install the fan center according to the manufacturer s instructions. Install the into the wall space behind the thermostat. onnect 2 wires from the to the thermostat cable and the other 4 wires to the thermostat. Install the eceiver in the indoor unit. onnect 2 wires from the eceiver to the thermostat cable, 2 wires to the fan center transformer power ( & ) and 2 wires to the fan center fan () & condenser () connections. The eceiver white wire is connected to a relay. The relay is used to control heat (). The 120 volt wiring for the fan is not shown see fan center instructions. elay T T ompressor Outdoor Unit enter Page 3

Air onditioning Adding wires between the indoor & outdoor units. Project: eplacing a single-stage A/ with a 2- stage A/. Problem: Not enough wires between the indoor and outdoor units. Solution: Use a Model 1000 to make a 2-wire thermostat cable into a 4-wire cable. Details: Install the at the furnace / air handler. onnect the green wire to the furnace 2 terminal, the yellow wire to the 1 terminal and the purple wire to the eceiver purple wire using one of the wires in the existing condenser cable. Use the other condenser cable wire to connect from the indoor unit to the outdoor unit connection. Install the eceiver in the outdoor unit and connect the green wire to 2, the yellow wire to 1, the black wire to, and the red wire to. At both the indoor and outdoor units install a jumper between the connections and electrical ground. 1000 2 1 2 1 ondenser able 1 2 ontrol Board onnect ommons to electrical ground. Outdoor Unit Air onditioning Adding wires between the t-stat, indoor & outdoor units. Project: eplacing a single-stage A/ with a 2-stage A/. and indoor unit and also between the indoor and outdoor units. Solution: Use 2 - Model 1000 s. 2 1 able Details: Install the at the thermostat. onnect the green wire to the 2 terminal, the yellow wire to the 1 terminal and the purple wire to the eceiver purple wire using one of the wires in the thermostat cable. Install one receiver at the indoor unit to control the fan speed. Use one of the condenser cable wires to connect the purple of one receiver to the purple wire of the other receiver. Use the other condenser cable wire to connect from the indoor unit to the outdoor unit connection. Install the eceiver in the outdoor unit and connect the green wire to 2, the yellow wire to 1, the black wire to, and the red wire to. At both the indoor and outdoor units install a jumper between the connections and electrical ground. eceiver 1000 condenser cable 1 2 ontrol Furnace / Air Handler ontrol eceiver 1000 2 1 onnect indoor & outdoor unit commons "" to electrical ground. ontrol Board ondenser Page 4

Pumps Adding wires between the indoor & outdoor units. Project: eplacing an A/ with a single or 2- stage heat pump. Problem: Not enough wires between the indoor unit and the outdoor unit. Solution: Use a Model 9000. Details: Install the Module at the indoor unit. onnect yellow to 1, brown to 2, blue to O/B, white to, & to. onnect one to & the other black to ground. onnect the orange wire to the orange wire of the outdoor unit module using one of the wires in the existing condenser cable. Use the other condenser cable wire to connect from the indoor unit to the outdoor unit connection. Install the Outdoor Unit Module in the outdoor unit and connect yellow to 1, brown to 2, blue to O/B, white to, & red to. onnect one to & the other black to ground. If the built-in dual fuel controller is not used, then leave the grey, green, & purple wires as they are. 9000 Pump Module eversing Valve - ut for "Fossil Fuel" mode Brown - ut for "cool active reversing valve" Pump OB 2 1 ompressor ompressor Pump ontrol Board rey rey emote Bulb (optional use) Defrost 30 40 20 50 10 60 0 1 2 O/B Mount bulb out of direct sunlight and in an area free of snow build up. ondenser able 9000 Module Pumps adding wiring between the t-stat, indoor & outdoor units Project: eplacing an A/ with a single or 2- stage heat pump. Problem: Not enough wires between the thermostat, indoor unit and the outdoor unit. Solution: Use a Model 7000. A 4-wire thermostat & a 2-wire condenser cable is required. 1 2 O/B 2, H, D, L etc. Brown ray Note: Extra wires can be used for other functions. onnect directly to thermostat and load as indicated. Details: onnect the and install it in the wall space behind the thermostat. Install the Furnace/ Air Handler and Pump Modules as shown below. onnect one wire to & the other black to ground at both modules. For single-stage use join the yellow & brown wires together onto the connections. If the built-in dual fuel controller is not used, then leave the grey, green, & purple wires as they are. Pump Module - ut for "Fossil Fuel" mode - ut for "cool active reversing valve" rey rey emote Bulb (optional use) 30 40 20 50 10 60 0 ondenser able able ray Furance / Air Handler Module For Single-Stage join yellow & brown wires together onto the "1" connection at both modules. Brown ontrol 1 2 ontrol Furnace / Air Handler Brown N OB 2 1 Brown 2 eversing Valve Defrost Pump ontrol Board ontrol ontrol Pump N Furnace / Air Handler Page 5

Pumps adding wiring between t-stat and indoor unit Project: eplacing an A/ with a single or 2-stage heat pump. and the indoor unit. Solution: Use a Model 5000. Details: The drawing below is for a fossil-fuel connection. The heat pump is shut off when the thermostat 1 and/or 2 is on. onnect the and install it in the wall space behind the thermostat. Install the eceiver in the Furnace/ Air Handler and connect as shown below. For supplemental heat operation (heat pump stays running when 1 and/or 2 is on) a relay would need to added at the eceiver to provide power to 1 when 1 and/or 2 is on. For a single stage furnace or strip heater, join the white and blue wires together onto the connections. 2 O/B 1 2 3,2,H,, etc. 5000 Note: Extra wires can be used for other functions. onnect directly to thermostat and load as indicated. able eceiver 1 1 2 2 OB 2 1 ontrol Pump Furnaces 2-stage heat with single-stage cool Project: Installing a 2-stage furnace with a singlestage air conditioner. Solution: Use a Model 5000. equires a minimum of a 2-wire thermostat cable. Details: Install the at the thermostat and the eceiver at the indoor unit. onnect wires as shown below. Extra thermostat cable wires can be used for other functions such as 2 etc. 1 2 3,2,O/B,H,, etc. Note: Extra wires can be used for other functions. onnect directly to thermostat and load as indicated. able eceiver 5000 1 2 ompressor ontrol ontrol Furnace iring Page 6

Furnaces 2-stage heat & cool Project: Installing a 2-stage furnace with a 2-stage air conditioner. Solution: Use a Model 5000. equires a minimum of a 3-wire thermostat cable for this application. Details: Install the at the thermostat and the eceiver at the indoor unit. onnect wires as shown below. 2 1 1 2 able eceiver 5000 2 1 1 2 2 ompressor ontrol ontrol Furnace iring Furnaces modulating gas valve Project: Installing a furnace with a modulating gas valve. Solution: Use a Model 1000. Details: By combining the and ompressor together on one wire, a wire is made available for use to connect the modulating gas valve connection to the thermostat. -mod able eceiver 1000 M Page 13 Page 7

oof Top Units & PTA s Project: Upgrading a TU or PTA. and unit. Solution: The Model to use depends on the number of additional wires that are required. To add one more wire use a Model 1000.To add two wires use a Model 3000. To add four wires use a Model 5000. More than one wiring extender can be used on the same system. For example, with a 4- wire cable a Model 1000 and a Model 3000 could both be used if needed. 2 2 1 1 able eceiver 3000 Details: onnect the and install it in the wall space behind the thermostat. Install the eceiver in the TU/PTA. In the example below, a Model 3000 is used to add 2-stage heating and 2- stage cooling control to a unit using a 4-wire cable. 1 2 1 2 Project: Adding manual fan control with a 2-wire cable. Solution: Use a Model 1000. able Details: onnect the and install it in the wall space behind the thermostat. Install the eceiver in the Furnace/ Air Handler and connect as shown below. eceiver 1000 Unit ompressor ompressor s adding manual fan control Page 8

s installing a powered thermostat Project: Installing a powered thermostat with a 4- wire cable. and the indoor unit. Solution: Use a Model 1000. Details: By combining the and ompressor together on one wire, a wire is made available for use to connect the common connection to the thermostat. able eceiver 1000 Project: Installing a powered thermostat with a 2- wire cable. and the indoor unit. able Solution: Use a ommon Maker. (This is a special order product) eceiver Details: The of the ommon Maker creates a common connection with only a 2-wire cable. onnect as shown below. ommon Maker s - Installing a powered thermostat with a 2-wire cable. Page 9

s adding an outdoor temperature sensor Project: iring for an outdoor temperature sensor. and the indoor unit. Solution: Use a Model 3000. A 4-wire thermostat cable is required. Details: The Model 3000 is used to combine,, & together on two wires. This provides two wires that can be used to connect the outdoor air temperature sensor. Sensor able eceiver 3000 Sensor ompressor Outdoor Unit able epair Example Project: epairing a cable with 1 broken wire. Solution: Use a Model 1000. Details: The wire that was used for has been cut and no longer functions. A Model 1000 is used to combine & together on 1 wire. The 3-wire cable now operates as a 4-wire cable again. able eceiver 1000 Page 10

How To Test a able Step 1 Disconnect the cable from the thermostat and indoor unit terminals. Step 2 Make a chart similar to the example. List each wire in order from L to & top to bottom. The last column is always rd which stands for round. Step 3 At the indoor unit, set meter to ohms and measure from test wire to each other wire. Using the chart as an example, measure from red to white, red to green, red to black & red to ground. Once a row is completed move down to next row. ecord the results in the left side square for each wire. The blacked-out squares do not need to be tested. ood wires should read infinity when tested this way. Once completed do step 4. Step 4 At one end of the cable join together the red & white wires together. o to the other end of the cable and measure the ohms. epeat this for all the wires in the row. hen completed, move down to the next row and repeat. ood wires will always have a 1 to 50 ohms reading. ecord the results in right side square for each wire. Notes In the chart examples in stands for infinity. Any reading above 100K ohms could be considered the same as infinity. The actual ohms measured will depend on cable length. rd Example: esults of a good cable rd in 8 in 7 in 8 in in 8 in 6 in in 7 in in Example: is broken (open circuit) rd in in in 9 in 8 in In in In In In In 8 In in epairing ables eneral ules 1. ires shorted to ground can only be used for ommon connections. Some equipment might not function properly with a grounded common. 2. Any wires shorted together can still be used, however they must be used as one single wire. eliability might be an issue if the wire breaks later on. If a nail or screw has gone through the cable and has shorted two or more wires together, there is no way to determine to what degree the copper wires have been damaged. Any subsequent movement of the cable might cause the wire to break where the nail/screw is. 3. ires that test as broken or open cannot be used. Problem: Two wires are shorted together on a 4-wire cable. Solution: If two wires out of a 4-wire cable are shorted together then the cable is used as if it is a 3-wire cable. To repair this cable a Model 1000 could be used to provide 4-wire control again. Example: is shorted to ground rd in 8 in 7 in 8 in in 8 in 6 In in 7 5 In Example: & are shorted together rd in 7 in 7 8 8 in in 8 in 6 in in 7 in in Problem: Three wires are shorted together on a 4-wire cable. Solution: This cable is used as if it was a 2-wire. If it is a thermostat cable then a Model 3000 could be used to provide 4-wire control for most applications. If it is a condenser cable then a Model 1000 or 3000 could be used. Problem: All the wires are shorted together on a cable. Solution: If it is a thermostat cable then the cable would need to be replaced. If it is a condenser cable a Model 1000, 3000 or 9000 could be used depending if the outdoor unit was an air conditioner or heat pump and whether is it single or 2-stage unit. A transformer would need to be installed in the outdoor unit as part of the repair. Problem: The cable has been spliced and the color coding is different for each cable used. Solution: Follow steps 1-3 above on How to test a cable. Do this to make sure that there are no shorts or grounded wires. eplace Step 4 with the following: A) Pick one wire in the cable and connect it to ground. B) o to the other end of the cable and test each wire for resistance (ohms) to ground. One wire in the cable should provide a reading of 1 to 50 ohms. This is the mate for the wire that is grounded. rite down this result. ) o back to the grounded wire and remove the connection to ground. onnect another wire to ground. epeat step B above and this step (step ) until all the wires have been tested. hen completed you will have a list that indicates how the cable wire colors have been paired. If a mate for a wire cannot be found then it was not connected when the splice was made or has become damaged. In either case the wire cannot be used. Page 11

How orks Model 1000 Function: Multipurpose wiring extender Application Examples: 2-stage air conditioning Adding manual fan control Installing a powered thermostat able repair. How It orks A 24 volt input on the yellow wire causes a 24 volt output on the eceiver yellow wire. Inputs A 24 volt input on the green wire causes a 24 volt output on the eceiver green wire. / ondenser able The yellow & green channels are independent. Either one can be on or off without affecting the other channel. eceiver The eceiver needs to have 24 volt power applied to the red and black wires in order to operate. Outputs elay elay How orks Model 3000 Function: Multipurpose wiring extender Application Examples: 2-stage air conditioning Adding Air onditioning Pump onversions able repair. How It orks A 24 volt input on the green wire causes a 24 volt output on the eceiver green wire. Inputs to "" A 24 volt input on the yellow wire causes a 24 volt output on the eceiver green and yellow wires. / ondenser able The yellow & green channels are independent of the white channel. Either one can be on or off without affecting the other channel. The eceiver needs to have 24 volt power applied to the red and black wires in order to operate. To 24 volt power Outputs elay eceiver elay elay Page 12

How orks Model 5000 Function: Multipurpose wiring extender Application Examples: 2-stage heating Installing a powered thermostat able repair. How It orks A 24 volt input on the green wire causes a 24 volt output on the eceiver green wire. A 24 volt input on the yellow wire causes a 24 volt output on the eceiver green and yellow wires. A 24 volt input on the white wire causes a 24 volt output on the eceiver white wire. The voltage output of the green & yellow wires will shut off when the white wire output is on. A 24 volt input on the blue wire causes a 24 volt output on the eceiver white and blue wires. To 24 volt power - - able elay - - - 1 Inputs - 2 - - Power eceiver ontrol Brd elay elay elay Outputs - - - 1-2 How orks Model 7000 Function: Air conditioner to heat pump conversions Single or 2-stage units Built-in dual fuel controller 4-wire thermostat & 2-wire heat pump cable required rey - 1 Brown - 2 - Inputs - - O/B - - Power To 24 volt power Outputs - - Brown - 2 - - able Module ontrol Brd rey elay elay elay How It orks A 24 volt input on any of the input wires causes a 24 volt output on the corresponding wires at the indoor & outdoor modules. The dual fuel (fossil fuel kit) allows for connections for a thermostat located at the heat pump. hen the temperature falls to the thermostat set point, the compressor will shut off and start the indoor unit or keep the compressor running while strip heaters are switched on at the indoor unit. The installer selects which mode of operation is needed. To 24 volt power Outputs Input - - - 1 Brown - 2 - O/B - Pump able rey elay for dual fuel controller (optional use) ontrol Brd elay Outdoor Unit Module elay Page 13

How orks Model 9000 Function: Air conditioner to heat pump conversions Single or 2-stage units Built-in dual fuel controller 2-wire heat pump cable required Inputs - 1 Brown - 2 - O/B ontrol Brd Module To 24 volt power - - elay Outputs - Pump able rey for dual fuel controller (optional use) How It orks A 24 volt input on any of the Indoor Module input wires causes a 24 volt output on the corresponding wires at the Outdoor Module. The dual fuel (fossil fuel kit) allows for connections for a thermostat located at the heat pump. hen the temperature falls to the thermostat set point, the compressor will shut off and start the indoor unit or keep the compressor running while strip heaters are switched on at the indoor unit. The installer selects which mode of operation is needed. Frequently Asked Questions To 24 volt power Outputs Input - - - 1 Brown - 2 - O/B - elay ontrol Brd elay Outdoor Unit Module The diagram is for a 2-transformer installation. By connecting a black wire at each module to ground, the 2 nd wire in the heat pump cable can be used to send transformer power outside which eliminates the need for a transformer at the heat pump. hat is the maximum distance between the and eceiver? enerally, you can expect the wiring extender to work with distances up to 500 feet. The actual distance depends on the transformer. A transformer with a low output voltage (20 23 volts) may not provide for the maximum distance. an I use more than 1 in the same building? es, you can use as many as you want. wiring extenders do not listen to radio frequencies and they are not affected by them. Also, they do not generate signals that would affect other electronic devices. How close together can they be located? They can be located side by side if desired. It is a good idea to leave a 1 inch gap between them to aid in cooling. an they be used in metal buildings? es, metal structures do not affect them. The transformer has a voltage output over 30 volts. ill this cause a problem? The maximum transformer voltage should not exceed 30 volts. If it does, then reliable operation could not be expected. The transformer voltage should be between 20 to 30 volts for proper operation. The is warm when operating. Is this normal? It is normal that the s of the models 3000, 5000 & 7000 produce heat in some modes of operation. For this reason it is recommended that the lead wires be left as long as possible so that the will be as far as possible from the thermostat once installed. If the is close to the thermostat, the heat from the could affect operation of the thermostat. The s produce less than 1 watt of heat, however this is enough to affect the thermostat if they are close together. hat other products are available? There is a Model 7000X and a 9000X which are for single-stage heat pumps. The dual fuel controller is removed from these models. These models are used for larger projects and provide a cost savings. There is also a ommon Maker model used to provide a common connection to a thermostat when there is only a 2-wire thermostat cable. The 7000X, 9000X & ommon Maker are special order products. Tech Support: 1-800-775-4750 Monday to Friday 9:00am to 5:00pm Pacific Standard Time Page 14 elay