International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Similar documents
PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Enhancement of COP in Vapour Compression Refrigeration System

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance investigation of Air-conditioning system using ejector as expansion device

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Modified Air Cooler with Split Cooling Unit

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Using Evaporative Cooling Methods for Improving Performance of an Air-cooled Condenser

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Reduction Of Energy Consumption in Airconditioning Systems employing direct evaporative pre-cooling of Condenser air

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Journal of Informative & Futuristic Research ISSN (Online):

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

(Refer Slide Time: 00:00:40 min)

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Design and Analysis of Water Cooled Condenser

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Performance Improvement of Air Conditioning System using Applications of Evaporative Cooling: A Review Paper

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Adsorption refrigeration system using waste heat

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Chapter 10. Refrigeration and Heat Pump Systems

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Performance Optimization of the Evaporative Condenser Design

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Global Journal of Engineering Science and Research Management

Modelling the Performance of a Diffusion Absorption Refrigeration System

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Numerical Simulation of Window Air Conditioner

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Performance Study of Triple Concentric Pipe Heat Exchanger

Recent Advances in Energy, Environment and Economic Development

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Assessment of Water Cooled Condenser Refrigeration System

η second law = Second law efficiency

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

REVIEW ON HOT GAS DEFROSTING SYSTEM FOR VAPOR COMPRESSION REFRIGERATION SYSTEM

*Corresponding author;

II. OBJECTIVE OF RESEARCH

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

ISSN Vol.08,Issue.21, November-2016, Pages:

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

DEEPAK PALIWAL, S.P.S.RAJPUT

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Experimental Analysis and Performance Comparison between Evaporative Cooling System and Air Conditioning System

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

ENSC 388. Assignment #6

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

LECTURE-17. Multi-Stage Vapour Compression Refrigeration. 1. Introduction

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

ADVANCES in NATURAL and APPLIED SCIENCES

Transcription:

ISSN 2229-5518 865 Abstract global warming and as a result, ambient temperature is rising significantly. Refrigeration and air- cooling systems are becoming necessary in almost all parts of India, even in places with moderate climate. Alternatively, the energy costs are shooting up day by day because of the limited availability of non-renewable types of energy. Vapour compression refrigeration system, though a century old refrigeration system, is still, the most commonly used refrigeration system. Most of the conventional refrigerating and air conditioning systems uses vapour compression refrigeration cycle, which involves evaporator, compressor, condenser, and an expansion device. However, a major drawback of conventional vapour compression refrigeration systems is that they account for a major portion of electric power consumption. A slight improvement in the performance of vapour compression refrigeration systems will have a significant influence on energy saving, considering enormous number of refrigeration and air-conditioning units globally. By using cost effective modifications like evaporative condensers instead of conventional air condensers, the performance of vapour compression refrigeration systems can be improved. Usually COP is used as a performance index for refrigerators and air-conditioners. But COP considers only the quantity of energy and not the quality. In real practice, even though quantity of energy is conserved, its quality is always degraded. So COP alone is not a realistic measure of performance for refrigerators and air conditioners. In this work, exergy analysis is done on an experimental R22 split air conditioning system, retrofitted with an evaporative condenser. Exergy efficiency is used as a performance index to measure the improved performance of the system. By using evaporative condenser instead of conventional air condenser, about 36% improvement in exergy efficiency is obtained. Keywords exergy analysis, exergy efficiency, exergy destruction, evaporative cooling. Industrial Refrigeration and Cryogenics department TKM College of engineering Kollam, India major portion of our daily power consumption is spent for the different cooling requirements. Even though different types of machines are employed in cooling applications, one of the most widely used types is the vapour compression refrigeration (VCR) system. A basic vapour compression refrigeration system is composed of four basic components: evaporator, compressor, condenser and expansion valve, as shown in figure below. Fig.1: Schematic of basic vapour compression refrigeration system. Fig.2 and 3 respectively shows temperature entropy and pressure-enthalpy diagram of a basic VCR system. I. INTRODUCTION Today due to the adverse effects of global warming, the atmospheric temperature has climbed-up so far that the use of air-conditioners and refrigerators has become an integral part of human life even for those in villages. These cooling devices are generally energy intensive ones and eventually, a Fig.2: Temperature-entropy diagram of a basic VCR system. 2015

ISSN 2229-5518 866 Fig.3: Pressure- enthalpy diagram of a basic VCR system. In VCR system, the refrigerant vapour alternatively undergoes a change of phase from vapour to liquid and vice versa during a cycle. Even though VCR system is a century old refrigeration system,there are only slight changes from the basic one, on today's actual system The performance of a conventional VCR cycle can be improved either by enhancing the performance of any one of the components or all of them. Using evaporative condenser instead of conventional air condenser can be considered as energy efficient, environment friendly and cost-effective method to enhance the performance of VCR systems. When the ambient air temperature increase and approach 50 0 C or higher, as it happens in many Middle East countries, the performance of air condenser drops down. In such situations, VCR system work improperly since the temperature and the pressure of the condenser increase and the compressor is forced to work under greater pressure ratio, which results in more power consumption. The simple and cheapest remedy for this problem is to cool the ambient air temperature by employing evaporative cooling system. Usually, evaporative condensers are used in airconditioning systems to enhance their performance. There are 2 methods for evaporative cooling in condensers namely direct and indirect method. In direct method water is directly injected on the condenser and provides cooling effect. This method has many side effects including mineral deposits and corrosion of the condenser coils. Therefore, this method has rarely been used in air conditioning systems. In the indirect method water is injected on the evaporative media pad which is located in the way of air over the condenser and provides cooling effect by evaporation of water. Evaporative condensers are ideally suited for operation in dryer climates. Several researchers reported that the use of evaporative condenser in place of conventional condensers resulted in performance improvement of refrigerators and airconditioning systems. Some of the prominent works are mentioned below. Goswami et al. (1993) retrofitted an evaporative cooler on the existing 2.5ton air conditioning system by using an evaporative media pad and reported 20% power saving for the modified system when the ambient air temperature was 34 0 C. Zhang et al. (2000) investigated on the evaporative cooler filled with corrugated holed aluminium foil and presented correlations to predict the performance, pressure drop and temperature outlet of the cooler. They used correlations to predict the improvement of an air-cooled chiller by comparing the exit temperature of evaporative cooler with performance curve of the chiller and reported that COP of the chiller could be improved about 39%. Hosoz et al. (2004) conducted experiments on a refrigeration system employing 3 types of condensers, namely, the air-cooled, the water-cooled and evaporative condensers and compared the performance characteristics of the system in 3 cases. Experimental studies revealed that the refrigeration capacity and C.O.P. of the unit with evaporative condenser were higher than those of the one with air-cooled condenser by 31 and 14.3% respectively. Yu and Chan (2005) conducted simulation studies on an air- cooled chiller equipped with a direct evaporative cooler and showed up to 14.4% reduction in power consumption and up to 4.6% increase in the refrigeration effect. Youbi- Idrissi et al. (2007) proposed a water spraying system in front of the air-cooled condenser to reduced air temperature and developed a semi-local numerical model for a sprayed air-cooled condenser coupled with a refrigeration system. By using the model, they predicted that COP of the refrigeration system could be improved up to 55%. Hajidavalloo (2007) investigated the effect of using evaporative cooler in the window-air- conditioner by injecting water on the evaporative media pad installed in front of the condenser entrance and reported 16% reduction in power consumption and 55% improvement in total performance. Hajidavalloo et al. (2010) investigated the effect of using indirect evaporative cooling in split air-conditioning system under variable ambient conditions. Experimental studies revealed that at ambient temperature of 35 0 C, refrigeration capacity and COP improved by 16.4% and 31.7% respectively. At ambient temperature of 49 0 C, refrigeration capacity and COP improved by 20.1% and 50.6% respectively. Tissot et al. (2013), carried out an experimental and numerical study, for improving the energy performance of refrigerating machine, using a water spray upstream of the condenser. The experimental setup is based on a reversible heat pump used in cooling mode. Their results showed that water spraying upstream of the condenser may increase the 2015

ISSN 2229-5518 867 global COP of the system (refrigerating machine plus spraying system) up to 28.9% for relatively hot and dry air conditions. Usually COP is used as a performance index for refrigerators and air-conditioners. But COP considers only the quantity of energy and not the quality. In real practice, even though quantity of energy is conserved, its quality is always degraded.cop alone is not a realistic measure of performance for refrigerators and air conditioners. So in this work, exergy analysis of an experimental R22 split air conditioning system(hajidavalloo et al.(2010)), retrofitted with an evaporative condenser is carried out and performance improvement is evaluated in terms of exergy efficiency. II. EXERGY ANALYSIS the base system (i.e., vapour compression refrigeration system using air condenser) and modified system (i.e., vapour compression refrigeration system retrofitted with evaporative condenser). The magnitude of specific exergy at every state is determined from the following equation, e=e ph +e k +e p +e ch (2.1) where, e ph - Physical exergy, e k Kinetic exergy, e p Potential exergy, e ch chemical exergy. Kinetic, chemical and potential exergies are neglected. Therefore, specific exergy at each arbitrary state can be assumed to be equal to the physical exergy. e=e ph =(h h 0 T 0 (s s 0 ) (2.2) After finding out the specific exergy at each state point in the system, the general exergy flow equation is applied to each component in the system, assuming the system to be in steady state. The general exergy flow equation for each component is defined as below: Fig.4: Vapour compression refrigeration system using air condenser. flow work. Fig.5: Vapour compression refrigeration system retrofitted with evaporative condenser. In this section exergy analysis of experimental R22 split air conditioning system (Hajidavalloo et al. (2010)) is carried out. Figure 4 and 5 represent the control volumes for Where, Q j Time rate of heat transfer in the j th component. T j Temperature at which heat transfer takes place. T 0 Dead state temperature. W cv Time rate of energy transfer rate by work other than m Mass flow rate e Specific exergy Ed Exergy destruction in the component. In order to find out exergy destruction in different components of the split a.c. system, equation (2.3) is applied to each component of the split a.c. system. Thus, applying equation (2.3) for the compressor gives, Exergy destruction in compressor, (Ed) comp =me 1 -me 2 -W c (2.4) Now, for the split a.c. system using air condenser (base system) Exergy destruction in condenser, (Ed) cond =me 2 -me 3 -W fan (2.5(a)) For the split a.c. system retrofitted with an evaporative condenser (modified system) Exergy destruction in condenser, (Ed) cond =me 2 -me 3 -W fan -W pump (2.5(b)) 2015

ISSN 2229-5518 868 Where W fan is the fan work and W pump is the pump work required for the recirculation pump used to spray water in an evaporative condenser. While calculating exergy destruction in condenser, the term associated with heat transfer in condenser is neglected because, the magnitude of the term will be very small considering the temperature difference between ambient and average surface temperature of the condenser[8], [9]. Exergy destruction in expansion valve, (Ed) exp =me 3 -me 4 (2.6) Exergy destruction in evaporator, Where, E d Exergy destruction, E xin Exergy input. Exergy output. Exergy analysis was conducted by considering the following Fig.7a: Exergy destruction when air condenser is used. assumptions: 1. Dead state pressure and temperature are assumed as 1atm and 308 K respectively. 2. Heat rejection in the condenser and compressor are assumed to take place at near ambient conditions. 3. Exergy losses in the suction line, discharge line and other pipelines are neglected III. RESULTS AND DISCUSSIONS Exergy analysis of the experimental split a.c. system (Hajidavalloo et al. (2010)) using air condenser and evaporative condenser is carried out separately and performance of both the systems is compared on the basis of percentage increase in exergy efficiency. Fig.6: Variation of total exergy destruction with system modification Fig.7b: Exergy destruction when evaporative condenser is used. From fig.6, it may be observed that, by using evaporative condenser instead of conventional air condenser total exergy destruction of the system is reduced. As a result the exergy efficiency of the modified system using evaporative condenser is very high compared to the system using conventional air condenser. In fig.7a and fig.7b, the exploded portion of the graph shows the percentage of exergy input converted into useful work or exergy output, which is same as the exergy efficiency. On comparing fig.9a and 9b, we can see that by using evaporative condenser exergy 2015

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN 2229-5518 efficiency increased from 18.48% to 25.16% i.e., about 36% increase in exergy efficiency is observed. 869 condenser decreased. As the condensing pressure drops due to the use of evaporative condenser, the compressor discharge pressure will also be less, resulting in a lower compressor pressure ratio and hence the exergy destruction in compressor also decreases. The pressure difference between the condenser and evaporator side reduced and hence the exergy destruction in the expansion valve also decreased. The mass flow rate through the evaporator is found to be increased and as a result the load on evaporator is increased, which resulted in increase of exergy destruction in the evaporator. Exergy analysis is conducted on the experimental Fig8: Exergy destruction in various components From fig.8, it may be inferred that maximum exergy destruction occurred in condenser and is followed by compressor, evaporator and expansion valve. By using evaporative condenser, the condensing pressure and temperature decreases. As a result the approach temperature in the condenser reduced and hence the exergy destruction in the work by Hajidavallo et al. (2010) and based on the results of exergy analysis Grassmann diagrams are drawn for both base and modified systems.fig.9and 10 given below respectively, shows the Grassmann diagram or exergy flow diagram for the split a.c. system (Hajidavalloo et al.(2010),when air condenser is used (base system)and when evaporative condenser is used(modified system). Grassmann diagram or exergy flow diagram is a graphical representation of the flow of exergy in any system. It gives an idea about how the input exergy supplied to a system is destroyed or utilized in different components of the system. So Grassmann diagram is drawn for the base system using air condenser and for the modified system using evaporative condenser. Fig.9: Grassmann diagram for the split a.c. system when air condenser is used. 2015

ISSN 2229-5518 870 Fig.10: Grassmann diagram for the split a.c. system when evaporative condenser. In fig.9, it may be seen that the energy input to the system are compressor work of 0.419kW, and condenser fan condenser. From exergy analysis of the experimental work (Hajidavalloo et al.(2010),it is found that by using work of 0.065kW. evaporative condenser instead of conventional air Exergy destruction values in compressor, condenser, about 36% improvement in exergy efficiency of condenser, expansion valve and evaporator are 0.3094kW, vapour compression refrigeration system is obtained. 0.6344 kw, 0.1122 kw and 0.1538 kw respectively. It may be observed that the exergy output from the system is only IV CONCLUSIONS 0.2742 kw.fig.10 shows the Grassmann diagram for the From literatures it was observed that by using modified system using evaporative condenser. In Fig.10, it evaporative condenser instead of conventional air condenser may be seen that the exergy input to the system are the performance of VCR systems, especially airconditioners compressor work of 1.225 kw, fan work of 0.070 kw and an additional pump work (pump used for spraying water in evaporative condenser.) of 0.015kW.From experimental results, it may be said that because of the improved performance of evaporative condenser, the condensing temperature and pressure reduced slightly and as a result can be improved drastically. Most of the experimental works available in literatures rely on COP, as a measure of performance improvement. But COP considers only the quantity of energy and not the quality. In real practice, even though quantity of energy is conserved, its quality is always degraded. So COP alone is not a realistic compressor work in the modified system is found to be less. measure of performance for refrigerators and air For the modified system, exergy destruction values in conditioners. compressor, condenser, expansion valve and evaporator are 0.2112 kw, 0.4922 kw, 0.07608 kw and 0.2009kW respectively. On comparing with the base system exergy destruction in all the components except the evaporator reduced. Exergy destruction in evaporator increased slightly due to increase in load on the evaporator. It may be observed that as a result of system modification exergy output increased from 0.2742 kw to 0.3296 kw. Exergy In this work exergy analysis of an experimental R22 split air conditioning system, retrofitted with an evaporative condenser (Hajidavalloo et al.(2010)), is carried out. Exergy destruction in system components such as compressor, condenser, expansion device and evaporator are found out for both the cases (i.e., by using air condenser and by using evaporative condenser.).on modifying the split air conditioning system (based on VCR system) with efficiency, which is the ratio of exergy output to exergy evaporative condenser instead of conventional air input, can be used as a realistic index to measure the condenser, exergy destruction in all the components, except improved performance of the system using evaporative 2015

ISSN 2229-5518 871 the evaporator reduced. Exergy destruction in evaporator increased slightly due to increase in load on the evaporator. By using evaporative condenser instead of [1] Goswami, D.Y., Mathur, D.Y., Kulkarni, S.M., 1993. conventional air condenser, the condensing temperature and Experimental investigation of performance of a pressure reduced slightly and as a result the approach residential air conditioning system with an evaporatively temperature in the condenser cooled condenser. Journal of Solar Energy Engineering 115, reduced and hence exergy destruction in condenser reduced. 206 211. As the condensing pressure reduced, the [2] Zhang, H.,You,H.,Yang,H.X.,Niu,J.L.,2000 Enhanced compressor discharge pressure also get lowered, resulting in reduction of compressor pressure ratio and hence the exergy destruction in compressor decreased. By using evaporative performance of air-cooled chillers using cooling. Building Services Engineering Technology 21, 213-217. evaporative Research condenser, compressor exit temperature and hence the [3] M.Hosoz, A.Kilicarslan, 2004. Performance evaluations of compressor work also get reduced. The pressure difference refrigeration systems with air-cooled, water-cooled and between condenser and evaporator side reduced and hence evaporative condensers. Int. J. Energy Res.28:683 696. the exergy destruction in expansion valve also decreased. [4] Yu, F.W., Chan, F.W., 2005. Application of direct In this work Grassmann diagram is used as a tool evaporative coolers for improving the energy to understand, how the input exergy supplied to a system is destroyed or utilized in different components of the system. efficiency of air-cooled chillers. Journal of Solar Engineering 127,430-433. Energy From the Grassmann diagrams drawn, it may be observed [5] Youbi-Idrissi, M., Macchi-Tejeda, H., Fournaison, L., that as a result of system modification exergy output Guilpart, J., 2007. Numerical model of sprayed air cooled increased from 0.2742 KW to 0.3296 KW. By using condenser coupled to refrigerating system. Energy evaporative condenser instead of conventional air condenser Conversion & Management 48, 1943 1951 about 36% improvements in exergy efficiency of VCR [6] Hajidavalloo, E., 2007. Application of evaporative cooling system is obtained. So, on the basis of exergy efficiency, on the condenser of window air- conditioner. Applied which is a more realistic performance index than COP, it Thermal Engineering 27, 1937 1943 may be stated that the use of evaporative condenser is a cost [7] E. Hajidavalloo, H.Eghtedari, 2010. Performance effective and promising modification for improving the improvement of air-cooled refrigeration system by using performance of conventional VCR systems. The major evaporatively cooled air condenser. i n t e r n a t i o n a l journal significance of this modification is that the use of of r e f r i g e r a t i on 3 3,9 8 2 988. evaporative condensers is ideally suited for operation in less humid places with high ambient temperatures, especially in [8] Onder Kizilkan, Ahmet Kabul, Ali Kemal Yakut, Middle East countries, where the use of refrigeration and air 2010.Exergetic performance assessment of a conditioning systems are inevitable. Acknowledgment variable-speed refrigeration system. International of energy research34, 463-475.DOI:10.1002/er.1553 journal [9] S. Anand, S.K.Tyagi, 2012.Exergy analysis and I express my sincere gratitude to my guide Dr. Rijo Jacob Thomas, Assistant Professor, Department of Mechanical Engineering for the expert guidance rendered during the course of this work. I am also thankful to him for constant encouragement for the progress of this work and also for the preparation of this paper. I am extremely thankful to the principal and management of TKM College of Engineering for providing excellent experimental and computing facilities at this college. I also express my gratitude to my parents and my classmates for their support to make this work a successful one. References experimental study of a vapor compression refrigeration cycle. J Therm Anal Calorim 110:961 971. DOI 10.1007/s10973-011-1904-z [10] J.Tissot,P.Boulet,F.Trinquet,L.Fournaison,M.Lejeune,F. Liaudet, 2013. Improved energy performance of a refrigerating machine using water spray upstream of the condenser. International Journal of Refrigeration.doi: 10.1016/j.ijrefrig.2013.08.025. 2015