Turbo Blowers Blower housings from cast aluminum, closed impellers from sheet aluminum, maintenance-free squirrel cage rotor motors of our own manufacture to IP 54. The blowers can be supplied in clockwise or counterclockwise rotation. High performance by V-belt pulley drive at compact design. Special blowers for specific applications, e.g. for higher media flow and ambient temperatures, with improved corrosion protection, with sealed housing parts, for special voltage and frequency as well as to enclosure IP 55 and thermal class F. applications Conveying of medium air volumes at higher system resistance Vacuum operation Forced air supply for gas, oil and coal fired systems Air supply for drying installations Air supply for air cushion tables VFT60 VFT65 VFT71-72-73 Dimensions in Inches Subject to change.
Regenerative Blowers Units come with Threaded Flanges DIMENSIONS IN INCHES ±1/8" FECOA Model Number A B C D E F G H VFD2/VFD2S 13.11 11.65 12.13 5.43 7.87 3.94 0.35 8.66 VFD3/VFD3S 14.37 11.10 11.85 5.43 7.87 3.94 0.35 8.66 VFD41/VFD41S 14.06 14.09 14.76 6.14 8.66 4.72 0.43 9.84 VFD42/VFD42S 14.06 14.09 14.76 6.93 8.66 4.72 0.43 9.84 VFD4 14.06 14.09 14.76 6.93 8.66 4.72 0.43 9.84 VFD5 16.54 15.20 16.46 6.93 12.20 6.30 0.51 13.78 VFD5D 19.72 16.54 18.50 8.58 12.20 6.30 0.51 13.78 VFD6 17.13 15.59 16.65 6.93 12.20 6.30 0.51 13.78 J K L 4.72 0.39 2.05 4.72 0.39 2.05 5.91 0.47 2.36 5.91 0.47 2.36 5.91 0.47 2.36 7.87 0.47 3.15 7.87 0.71 3.54 7.87 0.47 3.15 VFD6D 27.01 18.50 21.14 8.58 14.37 10.24 0.55 16.54 11.81 0.71 4.02 VFD8 24.80 19.69 20.94 10.16 14.37 10.24 0.55 16.54 11.81 0.71 3.35 VFD9 27.36 22.05 23.82 10.16 15.75 14.96 0.67 17.72 16.93 0.79 3.74 FECOA Model Number M N O P Q R S T U VFD2/VFD2S 3.78 1.50 3.54 2.28 6.30 2.76 0.67 13.11 M5 33.1/15 3/4 VFD3/VFD3S 3.78 0.94 3.54 1.89 6.30 2.36 0.67 14.37 M5 37.5/17 3/4 VFD41/VFD41S 2.60 1.77 3.54 2.68 7.72 3.11 0.67 14.06 M5 46.7/21.2 1 1/2 VFD42/VFD42S 2.60 1.77 3.54 2.68 7.72 3.11 0.67 14.06 M5 58.4/26.5 1 1/2 VFD4 2.60 1.77 4.92 2.68 7.72 3.11 0.67 14.06 M5 58.4/26.5 1 1/2 VFD5 2.83 2.17 4.92 3.35 8.86 3.94 0.67 16.54 M6 76.1/34.5 2 VFD5D 3.54 2.17 4.92 3.35 10.24 3.94 0.79 18.82 M6 124.6/56.5 2 VFD6 2.83 2.17 4.92 3.35 8.86 3.94 0.67 17.13 M6 78.3/35.5 2 VFD6D 5.63 2.56 5.71 4.33 11.89 5.12 0.79 27.01 M8 198.5/90 2 1/2 VFD8 5.63 2.56 5.71 4.33 11.10 5.12 0.79 24.80 M8 233.7/106 2 1/2 VFD9 2.28 3.15 6.30 4.65 12.80 5.71 0.98 27.36 M8 264.6/120 3 Weight lbs/kg Flanges inlet & outlet NPT
Performance Data PRESSURE VACUUM 5 4 Pressure in PSIG 3 2 1 VFD3 VFD41 VFD2 VFD42 VFD4 Vacuum Inches of Water 120 11 100 90 80 70 60 50 40 30 VFD3 VFD42 VFD41 VFD4 VFD2 20 10 0 0 20 30 40 50 60 70 80 90 100 11 120 1 20 30 40 50 60 70 80 90 100 110 120 PRESSURE VACUUM 8 200 Pressure in PSIG 7 6 5 4 3 2 1 VFD5D VFD5 VFD6 VFD8 VFD6D VFD9 Vacuum Inches of Water 75 50 25 00 75 50 25 VFD5 VFD5D VFD6 VFD6D VFD8 VFD9 100 200 300 400 500 600 0 00 200 300 400 500 600
Technical Information FUNCTION Impeller and side channel facing each other form a circular working chamber which is intersected between intake and discharge port. The rotation of the impeller causes a radial pressure rise in the cellular-shaped vanes which leads to a differential pressure distribution between channel and impeller resulting in a rotational flow between channel and cellular vanes. The pressure generated by the vanes ensures a further acceleration in the direction of rotation leading to a helical flow motion through the blower and a high pressure increase. DESIGN The blowers are directly driven by asynchronous squirrel cage motors made by Elektror. The sealed bearings ensure maintenance-free operation. Standard equipment silencers are mounted on the discharge and intake side thereby reducing the noise level considerably. All blower and motor parts are cast aluminum and therefore highly resistant to corrosion. The ribs on the blower housing provide for good heat dissipation, further assisted by the air flow of the motor fan. All blowers are equipped generally with base plate on the silencer and rubber feet for mounting in a vertical or horizontal position. OPERATING PERFORMANCE The blowers may be operated pulsation-free over the whole range of their performance curves. They are designed for the conveying of air as well as for generating pressure or vacuum. The use of the units for corrosive toxic media, air of high humidity and medium temperatures exceeding +40 C is subject to a detailed clarification. The conveying of explosive gases is not permitted.the units are to be installed in weather-protected places and must not be exposed to strain by vibrations, shocks and percussions. If the media to be conveyed contains solid particles or other pollutants, they are to be removed before entering the blower by installing a filter or similar device on the intake side. Blowers with limited performance curves in the high pressure range should be fitted depending on the application with the relative pressure relief valves in order to avoid an overload of the motor. Pressure relief valves can be mounted directly on the discharge port, vacuum relief valves directly on the intake port of the blower. Adjustment of the permitted maximum pressure of the blower is made in the factory. It is possible to adjust the valves below the maximum pressure. The rated values indicated in the performance curves are valid within a tolerance of +10%. The drive motors are manufactured in accordance with EN 60034-1 (VDE 0530 Part 1), amply dimensioned and suited for continuous operation. As a standard the motor insulation is class B and enclosure IP 54. Permitted ambient temperatures range from -20 C to +40 C, blowers can be speed controlled via AC inverter. Details about the installation and operation blowers may be obtained from the respective installation and operating instructions. FIELDS OF APPLICATION The blowers offer a wide field of application facilities wherever the use of air as energy supply leads to optimum results. The fields of application listed below present just a small segment. There are a wide range of possible applications for these units. Pneumatic air tube systems Pneumatic conveying systems Vacuum cleaning systems Vacuum lifting gear Vacuum transport system Bottle- filling stations Printing machines Screen printing machines Air-cushion tables Drying systems Welding fume extraction Textile machinery Agricultural machines Dental equipment Water treatment Fish pond aeration Aquarium aeration Aeration of galvanic tanks Air Knife systems ACCESSORIES A variety of accessories allow for a convenient installation of the blowers.
Performance Data PRESSURE Blower Model Motor HP Voltage Phase Frequency Rated Current at 230/460V Maximum Pressure inch H 2 O Maximum Flow SCFM Weight lbs/kg VFT60 7.0 230/460V 3φ 60Hz 18.8/9.4 40 1342 148/67 VFT65 11.0 230/460V 3φ 60Hz 30/15 33 2189 196/89 VFT71 15.0 230/460V 3φ 60Hz 42/21 42 2824 419/190 VFT72 23.0 230/460V 3φ 60Hz 54/27 55 3178 507/230 VFT73 31.0 230/460V 3φ 60Hz 72/36 69 3531 550/250 PERFORMANCE CURVES 72 64 VFT73 56 VFT72 Pressure Inches of Water 48 40 32 24 VFT71 VFT65 16 VFT60 8 0 500 1000 1500 2000 2500 3000 3500 FUJI ELECTRIC CORP. OF AMERICA Park 80 West Plaza II Saddle Brook NJ 07663 Phone (201) 712-0555 Fax (201) 368-8258 11/99 10M