High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Similar documents
Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

A. Codes and Standards that are Standard at the University:

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SECTION (15833) - HVAC POWER VENTILATORS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Selecting the Correct Fan

Direct Fired Heater Model AD Specification

University of Houston Master Construction Specifications Insert Project Name

SECTION AXIAL FANS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

A. This Section includes air-handling units with coils for indoor installations.

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Glossary of Terms Laboratory & Fume Exhaust Fans

Modular Supply Make-Up Air Unit

Bulletin FH05 FUME EXHAUST

MXI Mixed Flow Inline Fan

Direct Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

CONTENTS. B. System Design and Performance Requirements

B. System Design and Performance Requirements

Industrial Fans & Blowers

Fans: Features and Analysis

Introduction to Fans. The Basics of Fan Principles and Terminology

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

SECTION AIR HANDLING UNIT

SECTION CENTRAL HVAC EQUIPMENT

Belt Driven Mixed Flow Fans

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

1.1 This section applies to air handling units for HVAC Systems.

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SECTION WATER-SOURCE UNITARY HEAT PUMPS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Advance Release September 2009

Modular Heating & Ventilating Unit Model IGX-HV

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

XeteX, Inc. All Rights Reserved.

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Plenum Fans. Model HPA. Direct Drive

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

MARLOW PUMPS RECIRCULATION

AIR HANDLER SPECIFICATION

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Submittal Data Performance Data Electrical Data

SECTION AIR DUCT ACCESSORIES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise T-Series AHU Full Spec. Prepared by: Phone Number: Prepared for: Acceptable Manufacturers

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

City of Duluth Festival Center 04/25

University of Delaware

SECTION AIR OUTLETS AND INLETS

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

JM Aerofoil Fans Bulletin JMA60-05

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Centeral Station Air Handling Unit

Twin City Fan & Blower

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

SPECIFICATIONS - DETAILED PROVISIONS Section Heating, Ventilation, and Air Conditioning Equipment C O N T E N T S

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

QUICKSHIP PROGRAM. Twin City Fan QuickShip

Double Skin Air Handling Units

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

3.0 Factory packaged or modular constructed AHUs, when approved for use, shall conform to the following criteria:

KIC Air Curtains. Technical Guide

QUICKSHIP PROGRAM. Twin City Fan QuickShip

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Enviro KES INSTALLATON MANUAL

and SHUTTERS Made to Work. Built to Last.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

B. Unit shall be shipped as a single package unless the unit is too large to fit on a standard tractor-trailer.

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

SECTION COOLING TOWERS

Transcription:

High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust Fans 1.02 RELATED WORK All sections, drawings plans, specifications and contract documents. 1.03 REFERENCES A. AMCA Publication 99, Standards Handbook (2003 Edition) B. AMCA Standard 210 99, Laboratory Methods of Testing Fans for Aerodynamic Performance Rating C. AMCA Standard 211 05, Certified Ratings Program Product Rating Manual for Fan Air Performance D. AMCA Standard 300 96, Reverberant Room Method for Sound Testing of Fans E. AMCA Publication 311 05, Certified Ratings Program Product Rating Manual for Fan Sound Performance F. AMCA 204 96, Balance Quality and Vibration Levels for Fans G. AMCA 500 D 98, Laboratory Methods of Testing Dampers for Rating H. AMCA 500 L 99, Laboratory Methods of Testing Louvers for Rating I. SMACNA HVAC Duct Construction Standards Metal and Flexible, Medium Pressure Plenum Construction J. ANSI/AIHA Z9.5 2003, Laboratory Ventilation K. ANSI/ABMA 11 1990 (R1999), Load Ratings and Fatigue Life for Roller Bearings L. ASHRAE, Laboratory Design Guide (2002 Edition) M. ASTM B117 03, Standard Practice for Operating Salt Spray (Fog) Apparatus N. ASTM D2247 02, Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity O. ASTM D2794 93(2004), Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact) 1.04 QUALITY ASSURANCE A. Performance ratings: Fans shall be licensed to bear the AMCA Certified Ratings Seal for Sound and Air Performance. Acceptable manufacturers whose equipment is not licensed to bear the AMCA Certified Ratings Seal for Sound and Air Performance shall submit sound and air performance data obtained and calculated in accordance with AMCA Standards 210, 211, 300, and 311. These tests shall be performed by a laboratory that is accredited by AMCA.

B. Fans shall be manufactured at an ISO 9001 Certified facility. C. Units specified as Spark Resistant Construction shall conform to AMCA Standard 99 0401 86, Classifications for Spark Resistant Construction. D. Fan impeller shall be statically and dynamically balanced in accordance with AMCA Standard 204 96, Balance Quality and Vibration Levels for Fans. Vibration tests shall be conducted and recorded on each assembled fan before shipment at the specified fan RPM. These readings shall conform to the AMCA 204 96 Standard. E. Fan manufacturer shall provide at the owner and engineer s expense and option, witness testing of the fan in an AMCA Accredited Laboratory during the submittal stage of the project. These tests shall be performed in accordance with AMCA Standard 210 99, Laboratory Methods of Testing Fans for Aerodynamic Performance Rating." 1.05 SUBMITTALS A. Provide dimensional drawings, product data and performance on each high plume dilution laboratory exhaust fan unit. B. Provide fan curves for each fan at the specified point of operation. Airflow, static pressure and brake horsepower shall be clearly shown on the submittal. Fan curves submitted for review not utilizing a one to one (same scale for horizontal and vertical axis) scale shall be rejected. For multiple fan assemblies, fan curves shall also be adjusted to show assembly operation. C. Primary airflow from laboratory exhaust system, optional bypass airflow through mixing box, overall airflow through fan, and discharge nozzle airflow shall be provided. Outlet nozzle velocity and plume rise calculated per ASHRAE Applications Handbook shall also be provided for the specified fan performance and wind velocity. PART 2 PRODUCTS 2.01 GENERAL A. Fan performance data shall follow AMCA Standard Conditions of 0 Ft elevation and 70 Deg F. (Air Density shall be 0.075 lb/ft) B. Fans selected shall allow for +/ 15% variation of scheduled static pressure and airflow. C. Fan shall be AMCA Arrangement 9, Belt Drive, Upblast Inline Centrifugal Blower as dictated on the plans and specifications. D. Fan systems shall incorporate integral lifting lugs for ease of installation. 2.02 FAN HOUSING AND CONSTRUCTION A. Fan housing shall be a minimum 12 gauge steel construction. B. Adjustable motor plate, where applicable shall utilize threaded studs for positive belt tensioning.

C. Fan shall be constructed with an integral housing drain to alleviate rainwater. D. Fan shall contain a bolted and gasketed access door. Access door shall allow for the removal of wheel, shaft and bearings without the removal of the fan from the laboratory exhaust system. E. Belt driven fan shafts shall be stainless steel and accurately turned, ground and polished. Shafting shall be sized for a critical speed of at least 125% of maximum fan RPM. F. Unit fasteners exposed to corrosive airstream shall be of stainless steel construction. G. Option1 Unit components fabricated of steel shall be coated with an electrostatically applied, high performance, baked phenolic epoxy powder coating with an ultraviolet protective topcoat. Finish color shall be light gray. Coating thickness shall be 5.0 mils. Option2 Unit components fabricated of steel shall be coated with an electrostatically applied, baked epoxy powder coating with an ultraviolet protective topcoat. Finish color shall be dark gray. Coating thickness shall be 5.0 mils. Option3 Unit components fabricated of steel shall be coated with an electrostatically applied, baked polyester powder coating. Finish color shall be gray. Coating thickness shall be 2.0 mils. Coating shall be salt spray tested per ASTM B117 for in excess of 1000 hours without failure, humidity resistance tested per ASTM D2247 for in excess of 1000 hours without failure, and impact resistance tested per ASTM D2794 and shall pass a minimum of 100 in lbs. H. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. I. Units specified as Spark Resistant Construction shall be constructed to the AMCA Spark Resistant Construction level as dictated on the plans and specifications. J. Unit shall be shipped in ISTA Certified Transit Tested Packaging. 2.03 HIGH PLUME DISCHARGE NOZZLE A. Fans shall incorporate a conical discharge nozzle supplied by the fan manufacturer. B. Discharge nozzle shall be constructed and designed to efficiently handle up to 6000 feet per minute outlet velocity. Nozzle shall not utilize a stack cap nor hinged cover and shall be matched to project specific requirements as noted on the contract drawings. 2.04 CENTRIFUGAL FAN IMPELLER

A. Fan impeller shall be non overloading, steel centrifugal, backward inclined, flatblade type. Blades shall be continuously welded to the backplate and deep spun inlet wheel shroud. B. Fan impeller hub shall be keyed and securely attached to the fan shaft. C. Fan impeller shall be statically and dynamically balanced in accordance with AMCA Standard 204 96, Balance Quality and Vibration Levels for Fans. D. Fan impeller shall be coated with a finish to match the fan housing. E. Fan impeller shall be balanced utilizing weights which are welded and coated with chemical resistant coating. Balancing by means of bolts and washers shall not be acceptable. F. Belt driven fan bearings shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreaseable ball or roller type in a cast iron pillow block housing utilizing concentric mounting locking collars. G. Option1 Belt driven fan bearings shall be selected for a minimum L50 life of not less than 200,000 hours. Option2 Belt driven fan bearings shall be selected for a minimum L10 life of not less than 200,000 hours. H. Belt driven fan units shall have stainless steel lube lines installed from the fan bearings with Zerk fittings to allow for easy lubrication. 2.05 BYPASS AIR PLENUM A. For constant volume systems the fan and nozzle assembly shall be directly connected to the roof curb and exhaust duct. B. For variable volume systems a bypass air plenum shall be supplied as shown on the contract drawings. C. Bypass air plenum shall be designed to support fan assembly (assemblies) and configuration(s) as shown on the contract drawings. D. Bypass air plenum shall introduce outside air above the roof level and shall have rain hood(s) and bird screen protection over the bypass air damper(s). E. Bypass air plenum shall be constructed of welded steel, minimum 14 gauge, with a finish to match the fan housing. F. Bypass dampers shall be opposed blade low leakage design. The dampers shall be aluminum construction and coated to match the fan housing. Option1 Extended shafts and manual locking quadrant handles shall be provided for adjustment of the dampers. The extended shaft can be used for external connection to actuators by controls contractor. Option2 24V electric actuators shall be provided to control the dampers. The actuators shall be provided by the fan manufacturer.

G. Fan isolation dampers shall be provided as shown on the project documents. Option1 Isolation dampers shall be gravity type coated to match fan housing. Option2 Isolation dampers shall be opposed blade low leakage design. The dampers shall be aluminum construction and coated to match the fan housing. 2 position, spring return actuators shall be provided. The actuator shall be pre wired with appropriate transformer to the fan disconnect switch to open when the fan is energized and close via spring return when the fan is de energized. 2.06 FAN MOTORS AND DRIVES A. Option1 Fan motors shall be premium efficiency, NEMA frame, nominal 1800 or 3600 RPM Totally Enclosed Fan Cooled (TEFC) with a 1.15 service factor. Option2 Fan motors shall be premium efficiency, NEMA frame, nominal 1800 or 3600 RPM Totally Enclosed Fan Cooled, Inverter Duty Labeled with a 1.15 service factor. Option3 Fan motors shall be premium efficiency, NEMA frame, nominal 1800 or 3600 RPM Mill and Chem duty with a 1.15 service factor. Option4 Fan motors shall be premium efficiency, NEMA frame, nominal 1800 or 3600 RPM Explosion Proof with 1.0 service factor. Class and Division Rating. B. Option1 Belt driven fan drive belts shall be oil and heat resistant, nonstatic type. Fixed drives shall be sized for a minimum 1.5 service factor (150% of the motor horsepower) and shall be readily and easily accessible for service, if required. Option2 Belt driven fan drive belts shall be oil and heat resistant, nonstatic type. Fixed drives shall be sized for a minimum 2.0 service factor (200% of the motor horsepower) and shall be readily and easily accessible for service, if required. C. Belt driven fans shall utilize precision machined cast iron type sheaves, keyed and securely attached to the wheel and motor shafts. PART 3 INSTALLATION A. Install high plume fan system(s) as indicated on the contract drawings and in the contract specifications.

B. Install fan system(s) in accordance with manufacturers Installation, Operation, and Maintenance Manuals. Start up procedures from the IOM manuals shall be strictly followed. PART 4 ACCEPTABLE MANUFACTURERS A. Loren Cook Company, Model TCNHBLE