1. Read all instructions before proceeding with the installation. Improper installation may void warranties.

1. VCOM Panel Installation Instructions EIN-CP-GEN Panel Wiring Diagram EDW-WD-DAX-137

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

VERSATILE NEW BIW ALARM SYSTEMS DETECTS MOISTURE, LEAKS, HIGH LEVELS PLUS MANY OTHER OFF-NORMAL CONDITIONS

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

PO Box 827 Hawley, MN (218) Fax (218)

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Fluid Cooler Fan and Pump control panel

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

MAYI'A(; LEAVE THESE INSTRUCTIONS WITH THE OWNER LAISSER CE GUIDE DE MISE EN SERVICE AU PROPRIk'TAIRE DEJAR ESTAS INSTRUCCIONES CON EL PROPIETARIO

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

SP-1000X. Panic Device Power Controller Installation Guide. Rev

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Series. Access Power Controllers. Installation Guide

Installation, Operation & Service Manual

Installation Instructions

Installation Instructions

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

SSC-1D installation guide

Model 9001, Alarm

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Installation Instructions

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

Installation Instructions

Model 9001, Alarm

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Installation Instructions

Installation Instructions

Installation Instructions

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

INSTALLATION INSTRUCTIONS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

EVO192 v3.0 Fire and Burglary What s New

Installation Instructions

Installation Instructions 30 French Door Built-in Wall Ovens

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

MODEL MW200 MODEL MW600 AIR DRYER

Control Panel For Water Wash Hoods AM2

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL. Revised: July 2, 2017 DRAWING NO REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

ARM SERIES Switching Relays With Priority

Installation Instructions Wall Ovens

Wiring Diagrams Units Produced After April 20, 2009

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

Floating Pond Pump System 1/2, 3/4 & 1 HP 230V Models FPS05021, FPS07021, FPS10021

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

2 PREPARE THE OPENING

SAFETY INFORMATION AND WARNINGS

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following model: GS-1 GS-1-013EB GS-1-N13EB COUNTERTOP COOLER

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

Pump-Up Controller MODEL 4062

3480/RCH SERIES INSTALLATION INSTRUCTIONS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Installation and Operation Manual Low Power (LP) DC Power System

Duct and Rough Service Carbon Monoxide Sensor

American Dish Service

G-3/GS-3. Instruction Manual. G-Series Cooler. Manual is for the following model: GS-3-*21N** COUNTERTOP COOLER. * 0,N,2,B,P,Z,W **G,I,M,7 plug types

ECS 5M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Installation Guide for models:

Emerson Blue Easy Set 1H/1C

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

EATON DFDAP-M / FDAP-M Remote Alarm Panels

108A OTP1800. Grid Support. General Description

Q7800H Integrated Burner Control Subpanel

Electric Heat Accessory Installation Instructions

50A Integrated Furnace Control

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

FDF Foam Pump Controllers Features

MULTI-STAGE CHILLER CONTROL

CHAPTER 20 SERVICE EQUIPMENT

Centro-Matic Automated Lubrication Systems System Controls

Transcription:

Panel Wiring Diagram Model EAS-S1 PT LAA 1.1 1.2 1.3 From Main Power Panel 115 VAC, 1 Phase, 60 Hz. Main disconnect l provided by others. ) V :~::d W:::)-!_-...~.---------L_l! it-l----~ 115V10 N; El CB20A L21.T2 ~-----i 1.4 M1 NOTE: Motor!-:::=U 1i5U~C internal overload protection 10 Controls N ')------1 1 Hp MAX 115V 1(2) L 1 )-... 1.5 For Power Wiring 1.6 Options, See Page 2 CB10A Options POWER LGHT 1.7 DEC HW SERES HEATER 1.8 STEGO 01602.0-09.",,.'-.0"'.'".- ' M".. "",... 1.9 3~ -' - HGH LEVEL.10 High Level ALARM RELAY Alarm A1 DEC RJ2S LEVEL ALARM.11 LGHT DEC HW SERES Xl.12 2~...,.13 PT1 4 HAND OFF AUTO MOTOR.14 )( CONTACTOR Al ABB A 16-30-1 0-84.15 Timer On & Off ELAPSED TME METER GRASSLN.16.17 j Options; EVENT COUNTER KESSLER-ELLS PUMP RUN LGHT DEC HW SERES PROGRAMMABLE TMER.18 OMRON H3CR-F8 AS AR SWTCH COM NC LOW AR ALARM.19 TECMARK RELAY BS-TBS345 DEC RJ2S Contact Closed On Low Air.20 LOW AR LGHT DEC HW SERES AUDBLE ALARM.21 FLOYD BELL NW 09201 Q ALARM SLENCE.22 RELAY DEC RJ2S.23 PUSH TO SLENCE REMOTE ALARM.24 (AHW OR EQUV. 115 VAC ALARM).25 EDW-WD-OEM-ZO Rev 11 4/19/12 Page 1 of2

2.1 Power Wiring Options Simplex Operation 2.2 2.3 2.4 2.5 2.6 2.7 Two Circuits G> <3 c: :> 0.. Nut -------... One Circuit G> <3 c: :> 0.. High Level Alann: This fioat activates the alarm light and audible alarm when lifted. The audible alarm may be silenced by pressing the illuminated PUSH TO SLENCE button on the front of the control panel. The hih level alarm light will remain on until the float is lowered. Timer On & Off: This float turns off the programmable timer when lowered. When this float is lifted the timer will be restarted. Note: The timer will start with its off cycle. Programmable Timer: The timer turns the pump on and off in a pre-set cycle. Note: The timer will start with its off cycle. Low Air Alarm: The air monitoring switch activates the alarm light and audible alarm when low air pressure is detected. The audible alarm may be silenced by pressing the illuminated PUSH TO SLENCE button on the front of the control panel. The low air alarm light will remain on until the condition is corrected. 2.8 2.9 ~.10 Factory default. Wire as shown. Use one wire nut to connect the pole of the pump circuit breaker together with the controls breaker and with the incoming L 1 power line. Use another wire nut to connect the neutral block of the pump with the controls neutral block and with the incoming neutral line. ~. 11 ~.12 ~.13 ~.14 ~.15 ~.16 ~.17 ~.18 ~. 19 ~.20 ~.21 ~. 22 ~.23 ~.24 ~.25 ~.26 ~.27 )?R EDW-WD-OEM-20 Rev 3.1 4/19/12 Page 2 of2

EAS-S1 PT-LAA SERES CONTROL PANEL SEE SEPARATE WRNG DAGRAM ~~ L ~GROUND LUG DSCONNECT (TYP) UN-FUSED DSCONNECT BOX BY OTHERS AR BLOWER N SECURED, WATER TGHT HOUSNG CONTROLS Ground.J 115V 15A120A con:~t~;1 J L.. Ground -------------------------~ PUMP Pump L 1 J SNGLE-OUTLET 115V20A Neutral- - - - - - - _-.J WATERPROOF NON-GF PLUG RECEPTACLE N BLOWER HOUSNG NOTES: THESE FGURES DEPCT A RECOMMENDED WRNG CONFGURATON. OTHER POSSBLE VARATONS NCLUDE: 3 CRCUTS: ADD A SEPARATE CRCUT FOR THE AR BLOWER. USE OF BREAKERS: USES A SMALL BREAKER BOX. NOTE THAT NEC REQURES #10 AWG MN. FEEDER SZE N THS CASE. 230 VOLT PANEL: REQURES ENTRELY SEPARATE.115V CRCUT FOR THE AR BLOWER. OTHER NOTES: BLOWER RUNS CONTNUOUSLY, NDEPENDENT OF CONTROLS N PANEL. ALL WRNG TO BE WTHN APPROVED CONDUT. SEE TREATMENT UNT NSTALLATON MANUAL FOR CONNECTON OF LOW AR LNE. AR BLOWER & DSCONNECT WRNG DETALS NUWATER ATU USNG (2) 115VCRCUTS NuWATER REVSED: Advanced Treatment Systems By Enviro-Flo nc. 4/09/14 Washington Contact: Ek Engineering nc. (360) 687-7668 - (360) 687-7669 fax..... 'r

Panel nstallation Before nstalling Panel 1. Read all instructions before proceeding with the installation. mproper installation may void warranties. 2. nspect your order for completeness and inspect each component for shipment damage. f something is missing or damaged, you will need to contact your supplier to obtain replacements. 3. Check to be sure the instructions and items supplied comply with state and local regulations. 4. A qualified electrician must be employed to install and service the panel and ancillary wiring. The equipment must be installed in compliance with the National Electric Code, as well as state and local codes. Placement of the Control Panel 5. nstall the electrical control or alarm panel within view of the tank. The panel should be attached to a post or an exterior wall. Panels that contain motor contactors should not be mounted to an exterior wall unless the mounting method includes sound deadening. fpossible, position the panel in the shade to protect it from weather. Extreme temperatures can cause inconsistent performance of the electrical components. Locate the panel at a convenient height (usually about five feet above the ground) and where it will be accessible for maintenance. nstall Floats and Pumps 6. nstall the electrical splice box(es) for the floats and pump(s) before installing the actual floats and pumping equipment. The splice box(es) are installed in the grommet(s) provided near the top of the riser. 7. nstall the floats. Thread the float and pump cords through the cord grips into the PVC splice box, leaving adequate lengths of electrical cord coiled inside the riser to allow easy removal of the pump and float assembly. Do not remove the colored markers or the paper tags from the float cords, and do not try to thread the markers and tag through the cord grip. These should be left on the float cord, outside the splice box. Tighten the cord grips by hand, not by tool, then check the tightness of the cord grips by tugging on each cord. A cord is secure and the connection watertight when the cord grip is tight enough to prevent slippage. Adequate lengths of cord should be left within the splice box to allow for easy removal for future disconnecting and re-splicing. 8. Run the wires from the control panel to the splice box. The wires can be brought through a conduit, or can be buried using suitable direct-burial wire. Conduit that enters the splice box must be sealed with a conduit seal. A conduit seal should be used, even if the wires are direct-buried, to prevent the infiltration of water into the splice box. The number of wires required depends on the control panel and the number of floats and pumps used. This can be determined by consulting the Splice Box Wiring diagram appropriate for the control panel and float arrangement being used. Wire should be sized at 14 AWG for the float. Refer to Figure 1 to determine the proper size for the pump wires. When calculating wire size, you need to take the length and size of your branch circuit wires from the service entrance panel to the pump control EN-CP-GEN-6 Rev 1.0 12/18/01 Page 1

panel into account. Wire that's too small can cause an excessive voltage drop and poor pump performance. Wires should be color coded or otherwise marked to aid in wiring the control panel. Colors may refer to either the color of the wire's insulation, the color of a tag, or the color of an electrical tape marker. 9. All splices made in the splice box should use waterproof wire nuts or butt connectors and heat shrink tubing. The splices must be waterproof! Splices that are not waterproof may cause a malfunction of the pump controls if water should leak into the splice box. Connect Control Panel 10. Connect the wires coming from floats to the terminals in the control panel. 11. Connect the wires coming from the pump(s) to the pump terminals. 12. Connect the incoming power to the panel. Power to the panel must be appropriate to the control panel and pump motor (i.e. 120VAC, single phase for a 120 VAC motor, 240 VAC single phase for a 240 VAC motor, etc.) nsure that the panel is properly grounded and that the fuse or breaker and wire size, from the main power panel and to the pump, are sized correctly. Separate circuits for the pump controls and each of the pump motors is recommended. Note: Voltage for the controls in the panel is always 120VAC, although the pump voltage may be l20vac or 240 VAC. 13. Use 60 CU conductors only. Torque the terminal blocks to 7.1 LB-N. Torque the circuit breaker and ground lugs to 45 LB-N. 14. When power is applied to the control panel, the wires to the pump may be energized. Do not service the pump or any electrical wiring in the pump vault without disconnecting the power at the circuit breaker and the fuse. The pump vault area is a hazardous area, and may contain explosive gases. Take appropriate precautions before working in the pump vault. Figure 1. Recommended Breaker & Wire Size Pump Motor Size Breaker size Wire Size Max Distance* 115 VAC 1/3 hp 20 amp 12AWG 210 ft 112 hp 20 amp 12AWG 160 ft 230 VAC 112 hp 15 amp 14AWG 400 ft 1 hp 20 amp 12AWG 400 ft 1 112 hp 20 amp 12AWG 310 ft * This is the maximum distance from the main power panel to the pump motor for the recommended wire size. f actual distance is greater than the listed maximum, or more than one pump is on the circuit, then a larger gauge of wire must be used. f the actual distance is close to the maximum distance, then it is recommended that the next larger gauge wire be used. EN-CP-GEN-6 Rev 1.0 12/18/O1 Page 2

H3CR-FB Timer Setting nstructions On Cycle ndicator Off Cycle ndicator - OFF ON Omron H3CR Range Selection Switch Off Time Selection Switch On Time Selection Switch Record your timer setting here T~EROFF'-_ On Dial Off Dial Note: Power is supplied to the timer by the "Timer Off" float. n some systems, such as a Recirculating Sand Filter, a jumper wire connection may be substituted for the "Timer Off" float. The "Off" cycle is activated first. At the conclusion of the "Off" cycle the "On" cycle is activated. nstructions: STEP#1. Use a small screwdriver to set the range selection switch to the appropriate time range. Select from 0-1.2, 0-3, 0-12, or 0-30. The selected range must accomodate both the "on" and "off" time settings. f your desired time setting can be acquired in more than one time range, maximize accuracy by using the lowest time range possible. For example, a one hour setting can be more accurately adjusted in the 0-1.2 time range than in the 0-3 time range. STEP#2. Use a small screwdriver to set the offtime selection switch to the required time unit for the "Off" time. Select from seconds (sec), seconds x 10 (los), Minutes (min), or hours (hrs). STEP#3. Set the off dial (large dial with the green pointer) to the off time required. NOTE: The typical Off setting for an intennittent sand filter is 1 hour. STEP#4. Use a small screwdriver to set the on time selection switch to the required time unit for the "On" time. Select from seconds (sec), seconds x 10 (los), minutes (min), or hours (hrs). STEP#5. Set the on dial (small dial with the red pointer) to the on time required. NOTE: The typical On setting for an intennittent sand filter is 40 seconds. STEP#6. Record your timer settings in the space provided. Default Setting: The timer is factory set to 1 hour OFF, 40 seconds ON. Setting Example: Set the timer to the above default setting. Step#1. Set the range selection switch to 0-1.2 range. Step#2. Set the off time selection switch to hours (hrs) range. Step#3. Set the off dial to 1.0 for 1 hour Off setting. TMER ON, _ Step#4. Set the on time selection switch to minutes (min) range. Step#5. Set the on dial to approx. 0.67 for 40 seconds On setting. EN CP-SET-2410 Rev 1.0 09/30/10