STORAGE FIRE PROTECTION SPRINKLERS

Similar documents
E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Sprinkler Solutions for Storage Applications

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Sprinkler Identification Numbers

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

Submittal Packages Detailed with Items and Reviewers

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Sprinkler Identification Numbers

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Sprinkler Identification Numbers

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Box-in-Box Cold Storage Fire Protection Options

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Storage Sprinkler U.S. Quick Reference Guide

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

standard response elo upright and pendent sprinklers (storage-density/area)

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

TECHNICAL DATA NOTICE

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

standard/quick response extended coverage light and ordinary hazard elo sprinklers

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

standard response elo upright sprinkler

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Non-Storage / Special Protection / Storage Sprinklers

Model/Sprinkler Identification Numbers

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

AESTHETIC SPRINKLERS.

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

esfr pendent sprinkler vk510 (k25.2)

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Sprinkler Identification Number (SIN)

S p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

STORAGE PRODUCT BROCHURE

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

The Series LFII (TY3596) Residential

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Fire Protection Products Technical Data Book Table of Contents, August 2017

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

Transcription:

STORAGE FIRE PROTECTION SPRINKLERS

HOW CAN YOU REDUCE YOUR FIRE SPRINKLER INSTALLATION COSTS? Tyco Storage Sprinklers are intended for use in storage applications such as big box retail, extra hazard, high-piled and rack storage situations. These sprinklers can provide more water at lower pressures, and the extended coverage (EC) versions protect a larger area than standard sprinklers. When compared to a standard sprinkler EC-17 and EC-25 sprinklers reduce the number of sprinklers needed in an area by approximately half and consistently performs better in a retail application. Frequently, specially designed ceiling sprinklers can eliminate the need for in-rack sprinklers increasing your rack design options and mobility. Installing larger orifice, extended coverage sprinklers can be cost-effective by reducing the overall number of sprinklers needed to protect a large area, getting stores opened faster and installers on to the next job quicker. Tyco Fire & Building Products Storage Sprinklers are the solution to save you time and money. Area Coverage for Standard Spray Sprinkler 10 ft. Area Coverage for EC-17 & EC-25 Sprinklers 14 ft. 10 ft. 14 ft. SAVES YOU MONEY CONTRACTORS: FASTER INSTALLS TO GET YOU TO THE NEXT JOB SOONER LESS DESIGN TIME (WITHOUT IN-RACKS) OWNERS: INCREASE YOUR STORE RACKING FLEXIBILITY OPEN YOUR STORE SOONER WITH FASTER INSTALLS 2 design parameters installation instructions, care and maintenance guidelines, and our limited warranty.

EC SERIES EXTENDED COVERAGE STORAGE SPRINKLERS MODEL EC-17 16.8 K-FACTOR RECESSED & PENDENT Applications: Big Box Retail/Extra Hazard/High-Pile Storage SIN TY7228 Tech Data Sheet TFP215 Reduces Number Of Sprinklers Installed Extended Coverage - Maximum 196 ft. 2 (14 ft. x 14 ft.) Spacing Designed For Area/Density Applications Of 0.25 GPM/ft. 2. High Hydraulic Calculations Based On Actual Spacing Can Be Spaced At 15' x 9'7" (144 ft. 2 Max Per NFPA 13) Pendent Design Is Ideal For Retail Applications Approvals: UL & C-UL Listed Minimum Pressure: 7 psi (0,5 bar) Pipe Thread Connection: 3/4" NPT Discharge Coefficient: K = 16.8 GPM/psi 1/2 K = (241,9 LPM/bar 1/2 ) Temperature Ratings: 160 F (71 C) or 212 F (100 C), Chrome, or White MODEL EC-25 25.2 K-FACTOR UPRIGHT Applications: Big Box Retail/Extra Hazard/High-Pile Storage SIN TY9128 Tech Data Sheet TFP213 Standard Response For Use In Obstructed Ceiling Conditions Control-Mode Extended Coverage For High Density Applications Applications Requiring An Area/Density Application Of Water 196 ft. 2 /Sprinkler Spacing (14 ft. X 14 ft. Spacing) Reduces Number Of Installed Sprinklers By Nearly Half Hydraulic Calculations Based On Actual Spacing (SxL Rule) Approvals: FM Approved, UL & C-UL Listed Minimum Pressure: 7 psi (0,5 bar) Pipe Thread Connection: 1" NPT or ISO 7-R1 Discharge Coefficient: K = 25.2 GPM/psi 1/2 K = (362,9 LPM/bar 1/2 ) Temperature Ratings: 165 F (74 C) or 214 F (101 C) design parameters installation instructions, care and maintenance guidelines, and our limited warranty. 3

ESFR SERIES EARLY SUPPRESSION FAST RESPONSE SPRINKLERS MODEL ESFR-25 TM 25.2 K-FACTOR PENDENT SIN TY9226 Application: High-Pile Storage Designed For Use With Storage Heights Up To 40 ft. (12,2 m) And Maximum Ceiling Heights Of 45 ft. (13,7 m) Operates At A Lower-End Head Pressure Providing Hydraulic And Sprinkler Placement Options Not Available With Traditional ESFR Sprinklers Flexibility When Sizing The System Piping Reduces Or Eliminates The Need For A System Fire Pump Approvals: FM Approved, UL & C-UL Listed, VdS, LPCB & NYC Approved Pipe Thread Connection: 1" NPT or ISO 7-R1 Discharge Coefficient: K = 25.2 GPM/psi 1/2 K = (362,9 LPM/bar 1/2 ) Temperature Ratings: 165 F (74 C) or 214 F (101 C) Tech Data Sheet TFP312 MODEL ESFR-1 14.0 K-FACTOR SIN TY6226 Application: High-Pile Storage PENDENT Tech Data Sheet TFP318 Designed For Use With Storage Heights Up To 35 ft. (10,7 m) And Maximum Ceiling Heights Of 40 ft. (12, 2 m) Protects Group A Plastics, Class I-IV Commodities, Some Rubber Tires, Roll Paper, Flammable Liquids And Aerosols In Some Storage Arrangements Approvals: FM Approved, UL & C-UL Listed, VdS, LPCB & NYC Approved Pipe Thread Connection: 3/4" NPT or ISO 7-R 3/4 Discharge Coefficient: K = 14.0 GPM/psi 1/2 K = (201,6 LPM/bar 1/2 ) Temperature Ratings: 165 F (74 C) or 214 F (101 C) Requires one level of in-rack sprinklers. COMPARE ESFR PENDENT SPRINKLER PRESSURE FOR RACK STORAGE Max. Ceiling Max. Storage ESFR-25 ESFR-17 Pendent ESFR-1 Height ft. (m) Height ft. (m) Min. Pressure psi (bar) Min. Pressure psi (bar) Min. Pressure psi (bar) 45 (13,7) 40 (12,2) 40 (2,8) 63 (4,3) 90 (6,2) 40 (12,2) 35 (10,7) 25 (1,7) 52 (3,6) 75 (5,2) 35 (10,7) 30 (9,1) 20 (1,4) 52 (3,6) 75 (5,2) 30 (9,1) 25 (7,6) 15 (1,0) 35 (2,4) 50 (3,4) 4 design parameters installation instructions, care and maintenance guidelines, and our limited warranty.

ELIMINATES THE NEED FOR IN-RACK SPRINKLERS MODEL ESFR-17 16.8 K-FACTOR SIN TY7226 Application: High-Pile Storage PENDENT Tech Data Sheet TFP315 Designed To Protect Most Encapsulated Or Non-Encapsulated Common Materials Up To 35 ft. (10,7 m) And Maximum Ceiling Heights Of 40 ft. (12,2 m) Protects Cartoned Expanded Plastics Up To 25 ft. (7,6 m) With Ceiling Heights Up To 30 ft. (9,1 m) Provides Hydraulic And Sprinkler Placement Options That Are Not Available With The ESFR-1 Sprinkler Operates At A Lower-End Head Pressure Providing Flexibility When Sizing The System Piping And Reducing Or Eliminating The Need For A System Fire Pump Approvals: FM Approved, UL & C-UL Listed, VdS, LPCB & NYC Approved Pipe Thread Connection: 3/4" NPT or ISO 7-R3/4 Discharge Coefficient: K = 16.8 GPM/psi 1/2 K = (241,9 LPM/bar 1/2 ) Temperature Ratings: 165 F (74 C) or 214 F (101 C) MODEL ESFR-17 16.8 K-FACTOR SIN TY7126 Application: High-Pile Storage UPRIGHT Tech Data Sheet TFP316 Designed To Protect Most Encapsulated Or Non-Encapsulated Common Materials Up To 30 ft. (9,1 m) And Maximum Ceiling Heights Of 35 ft. (10,7 m) Protects Carton Expanded Plastics Up To 25 ft. (7,6 m) With Ceiling Heights Up To 30 ft. (9,1 m) Approvals: FM Approved Pipe Thread Connection: 3/4" NPT or ISO 7-R3/4 Discharge Coefficient: K = 16.8 GPM/psi 1/2 K = (241,9 LPM/bar 1/2 ) Temperature Ratings: 165 F (74 C) or 214 F (101 C) design parameters installation instructions, care and maintenance guidelines, and our limited warranty. 5

ELO SERIES EXTRA LARGE ORIFICE SPRINKLERS Designed for high-density, high-piled storage applications with storage heights up to 20 ft. (6,1 m) and a maximum ceiling height of 27 ft. (8,2 m). Higher flow rate can be achieved at much lower pressure with the ELO Series Sprinklers. MODEL ELO-231B 11.2 K-FACTOR SIN TY5151 Upright 3/4" NPT SIN TY5251 Pendent 3/4" NPT SIN TY5851 Upright 1/2" NPT Standard Response, Standard Coverage 5 mm Bulb Approvals: FM Approved, UL & C-UL Listed, NYC Approved Discharge Coefficient: K = 11.2 GPM/psi 1/2 K = (161,4 LPM/bar 1/2 ) Refer to TFP342 for temperature rating and sprinkler finishes for the ELO-231B. Tech Data Sheet TFP342 MODEL ELO-231FRB 11.2 K-FACTOR SIN TY5131 Upright 3/4" NPT SIN TY5211 Pendent 3/4" NPT Quick Response, Standard Coverage 3 mm Bulb Approvals: FM Approved, UL & C-UL Listed, NYC Approved Discharge Coefficient: K = 11.2 GPM/psi 1/2 K = (161,4 LPM/bar 1/2 ) Refer to TFP344 for temperature rating and sprinkler finishes for the ELO-231FRB. Tech Data Sheet TFP344 MODEL ELO-231 11.2 K-FACTOR SIN TY5111 Upright 3/4" NPT SIN TY5211 Pendent 3/4" NPT SIN TY5811 Upright 1/2" NPT Tech Data Sheet TFP340 Standard Response, Standard Coverage Solder Type. Approvals: FM Approved, UL & C-UL Listed, NYC Approved Discharge Coefficient: K = 11.2 GPM/psi 1/2 K = (161,4 LPM/bar 1/2 ) Refer to TFP340 for temperature rating and sprinkler finishes for the ELO-231. 6 design parameters installation instructions, care and maintenance guidelines, and our limited warranty.

MODEL LD LARGE DROP SPRINKLER SPRINKLER GUARDS & GUARDS WITH SHIELDS Tech Data Sheet TFP782 G2 SPRINKLER GUARD Helps Provide Protection For The Sprinklers From Accidental Abuse WS-2 SPRINKLER SHIELD Designed To Shield Sprinklers From Water Spray From Higher Elevation Sprinklers MODEL LD 11.2 K-FACTOR SIN TY5153 Application: High-Pile Storage UPRIGHT Tech Data Sheet TFP335 Standard Response 5 mm Bulb Specific Application Control Mode Sprinkler Designed For The Protection Of High-Piled Storage That Meets Large Drop Sprinkler Installation And Design Criteria Provides A Higher Level Of Protection Than Standard Spray Sprinklers Offers An Economical Alternative By Eliminating In-Rack Sprinklers Approvals: UL & C-UL Listed, NYC Approved Pipe Thread Connection: 3/4" NPT or ISO 7-R1 Discharge Coefficient: K = 11.2 GPM/psi 1/2 K = (161,3 LPM/bar 1/2 ) Temperature Ratings: 155 F (68 C) 200 F (93 C) WSG-2 SPRINKLER GUARD & SHIELD Helps Provide Protection For The Sprinklers From Accidental Abuse Shields Upright Sprinklers From Water Spray From Higher Elevation Sprinklers Approvals: UL & C-UL Listed Finish: Red Paint or Zinc Coated Physical Characteristics: Welded Assembly Fabrication From Carbon Steel. design parameters installation instructions, care and maintenance guidelines, and our limited warranty. 7

TY SERIES INTERMEDIATE LEVEL SPRINKLERS For use in rack storage sprinkler systems where thermally sensitive elements must be shielded from the water spray of higher elevation sprinklers that could operate earlier during a fire. Also used in other applications such as beneath open-gridded catwalks. MODEL TY-B 5.6 / 8.0 K-FACTOR SIN TY3153 Upright 1/2" NPT SIN TY3251 Pendent 1/2" NPT SIN TY4153 Upright 3/4" NPT SIN TY4251 Pendent 3/4" NPT Tech Data Sheet TFP351 Standard Response 5 mm Bulb Approvals: FM Approved, UL & C-UL Listed, NYC Approved Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 5.6 GPM/psi 1/2 (80,6 LPM/bar 1/2 ) K = 8.0 GPM/psi 1/2 (115,2 LPM/bar 1/2 ) Refer to TFP351 for temperature ratings and sprinkler finishes for the TY-B. MODEL TY-FRB 5.6 / 8.0 K-FACTOR SIN TY3133 Upright 1/2" NPT SIN TY3231 Pendent 1/2" NPT SIN TY4133 Upright 3/4" NPT SIN TY4231 Pendent 3/4" NPT Tech Data Sheet TFP356 Quick Response 3 mm Bulb Corrosion Resistant Coating Approvals: FM Approved, UL & C-UL Listed, NYC Approved Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 5.6 GPM/psi 1/2 (80,6 LPM/bar 1/2 ) K = 8.0 GPM/psi 1/2 (115,2 LPM/bar 1/2 ) Refer to TFP356 for temperature ratings and sprinkler finishes for the TY-FRB. 8 design parameters installation instructions, care and maintenance guidelines, and our limited warranty.

TY SERIES SPRINKLER GUARDS & GUARDS WITH SHIELDS Tech Data Sheet TFP780 MODEL TY-L 5.6 / 8.0 K-FACTOR SIN TY3113 Upright 1/2" NPT SIN TY3211 Pendent 1/2" NPT SIN TY4113 Upright 3/4" NPT SIN TY4211 Pendent 3/4" NPT Standard Response Solder Type Approvals: FM Approved, UL & C-UL Listed Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 5.6 GPM/psi 1/2 (80,6 LPM/bar 1/2 ) K = 8.0 GPM/psi 1/2 (115,2 LPM/bar 1/2 ) Refer to TFP350 for temperature ratings for the TY-L. MODEL TY-FRL 5.6 / 8.0 K-FACTOR SIN TY3123 Upright 1/2" NPT SIN TY3221 Pendent 1/2" NPT SIN TY4123 Upright 3/4" NPT SIN TY4221 Pendent 3/4" NPT Quick Response Solder Type Approvals: FM Approved, UL & C-UL Listed, NYC Approved Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 5.6 GPM/psi 1/2 (80,6 LPM/bar 1/2 ) K = 8.0 GPM/psi 1/2 (115,2 LPM/bar 1/2 ), Chrome Plated Refer to TFP355 for temperature ratings for the TY-FRL. Tech Data Sheet TFP350 Tech Data Sheet TFP355 G1& G4 SPRINKLER GUARD Helps Provide Protection For The Sprinklers From Accidental Abuse G1/S1 & G4/S3 SPRINKLER GUARD & SHIELD Helps Provide Protection For The Sprinklers From Accidental Abuse Shields Upright Sprinklers From Water Spray From Higher Elevation Sprinklers G4/S3 G4 G1 GI/S1 Approvals: UL & C-UL Listed Finish: Red Paint or Zinc Coated Physical Characteristics: Welded Assembly Fabrication From Carbon Steel. design parameters installation instructions, care and maintenance guidelines, and our limited warranty. 9

ULTRA K17 SPECIAL APPLICATION SPRINKLERS MODEL ULTRA K17 16.8 K-FACTOR SPECIAL APPLICATION CONTROL-MODE UPRIGHT Applications: High-Pile Storage SIN TY7153 Tech Data Sheet TFP330 Standard Response 5 mm Bulb Meets NFPA 13 Specific Application Control-Mode Requirement For High-Pile Storage Approved For Storage Heights Of 25 ft. (7,6 m) And Building Heights Up To 30 ft. (9,1 m) Full-Scale Fire Testing Has Shown That The Ultra K17 Can Control Fires With Commodities Up To Group A Plastics, And Eliminate The Need For In-Rack Sprinklers Reduces End Head Pressure Which Often Eliminates The Need For A Fire Pump Approvals: FM Approved, UL & C-UL Listed, NYC Approved Pipe Thread Connection: 3/4" NPT or ISO 7-R3/4 Discharge Coefficient: K = 16.8 GPM/psi 1/2 K = (241,9 LPM/bar 1/2 ) Temperature Ratings: 155 F (68 C) 200 F (93 C) K17 SERIES MODEL K17-231 11.2 K-FACTOR Application: High-Pile Storage SIN TY7151 Upright Tech Data Sheet TFP335 SIN TY7251 Pendent Standard Response 5 mm bulb Very Large Orifice Sprinkler For Use In High Challenge Storage Occupancies Meets The NFPA Requirements For Ordinary And Extra Hazard Occupancies. Low-Pressure Requirement Can Save Cost By Reducing Branchline Size, Taking Advantage Of Maximized Spacing, And Upgrading Existing Densities Approvals: FM Approved, UL & C-UL Listed, NYC Approved Pipe Thread Connection: 3/4" NPT or ISO 7-R3/4 Discharge Coefficient: K = 16.8 GPM/psi 1/2 K = (241,9 LPM/bar 1/2 ) Refer to TFP335 for temperature rating for the Model K17-231. 10 design parameters installation instructions, care and maintenance guidelines, and our limited warranty.

STORAGE SPRINKLER SPECIFICATIONS Storage Sprinklers Listed Have A Maximum Pressure Of 175 psi & Maximum Spacing Per NFPA. Refer to the Technical Data Sheet for specific information. All versions of a sprinkler may not be listed or approved. Sprinkler Thread K-factor Temperature Listings & Technical Model SIN Style Size Element Discharge Response Finish Rating Approvals Data Sheet EC-SERIES EC-17 TY7228 Pendent 3/4" Solder 16.8 GPM/psi 1/2 SR B, C, W 160 F. 212 F UL, C-UL TFP215 EC-25 TY9128 Upright 1" Solder 25.2 GPM/psi 1/2 SR B 165 F, 214 F FM, UL, C-UL TFP213 ESFR-SERIES ESFR-25 TY9226 Pendent 1" Solder 25.2 GPM/psi 1/2 FR B 165 F, 214 F UL, C-UL, FM, VdS, LPCB, NYC TFP312 ESFR-1 TY6226 Upright 3/4" Solder 14.0 GPM/psi 1/2 FR B 165 F, 214 F UL, C-UL, FM, VdS, LPCB, NYC TFP318 ESFR-17 TY7226 Pendent 3/4" Solder 16.8 GPM/psi 1/2 FR B 165 F, 214 F UL, C-UL, FM, VdS, LPCB, NYC TFP315 ESFR-17 TY7126 Upright 3/4" Solder 16.8 GPM/psi 1/2 FR B 165 F, 214 F FM TFP316 K17 SERIES Ultra K17 TY7153 Upright 3/4" 5 mm Bulb 16.8 GPM/psi 1/2 SR B 155 F, 200 F UL, C-UL, FM, NYC TFP330 K17-231 TY7151 Upright 3/4" 5 mm Bulb 16.8 GPM/psi 1/2 SR B 155 F, 200 F, 286 F UL, C-UL, FM, NYC TFP332 K17-231 TY7251 Pendent 3/4" 5 mm Bulb 16.8 GPM/psi 1/2 SR B 155 F, 200 F, 286 F UL, C-UL, FM, NYC TFP332 LD LARGE DROP LD TY5153 Upright 3/4" 5 mm Bulb 11.2 GPM/psi 1/2 SR B 155 F, 200 F, 286 F UL, C-UL, NYC TFP335 ELO-SERIES ELO-231 TY5811 Upright* 1/2" Solder 11.2 GPM/psi 1/2 SR B, C, L, W, WOL 165 F, 212 F, 286 F UL, C-UL, FM, NYC TFP340 ELO-231 TY5111 Upright* 3/4" Solder 11.2 GPM/psi 1/2 SR B, C, L, W, WOL 165 F, 212 F, 286 F UL, C-UL, FM, NYC TFP340 ELO-231 TY5211 Pendent* 3/4" Solder 11.2 GPM/psi 1/2 SR B, C, L, W, WOL 165 F, 212 F, 286 F UL, C-UL, FM, NYC TFP340 ELO-231B TY5851 Upright* 1/2" 5 mm Bulb 11.2 GPM/psi 1/2 SR B, C, L, W, WOL 155 F, 200 F, 286 F UL, C-UL, FM, NYC TFP342 ELO-231B TY5151 Upright* 3/4" 5 mm Bulb 11.2 GPM/psi 1/2 SR B, C, L, W, WOL 155 F, 200 F, 286 F UL, C-UL, FM, NYC TFP342 ELO-231B TY5251 Pendent* 3/4" 5 mm Bulb 11.2 GPM/psi 1/2 SR B, C, L, W, WOL 155 F, 200 F, 286 F UL, C-UL, FM, NYC TFP342 ELO-231FRB TY5131 Upright* 3/4" 3 mm Bulb 11.2 GPM/psi 1/2 QR B, C 155 F, 200 F, 286 F UL, C-UL, FM, NYC TFP344 ELO-231FRB TY5231 Pendent* 3/4" 3 mm Bulb 11.2 GPM/psi 1/2 QR B, C 155 F, 200 F, 286 F UL, C-UL, FM, NYC TFP344 TY-SERIES TY-B TY3153 (1) Upright 1/2" 5 mm Bulb 5.6 GPM/psi 1/2 SR B, C, L, W, WOL 135 F, 155 F, 175 F, UL, C-UL, FM, NYC TFP351 200 F, 286 F, 360 F TY-B TY3251 (1) Pendent 1/2" 5 mm Bulb 5.6 GPM/psi 1/2 SR B, C, L, W, WOL 135 F, 155 F, 175 F, UL, C-UL, FM, NYC TFP351 200 F, 286 F, 360 F TY-B TY4153 (1) Upright 3/4" 5 mm Bulb 8.0 GPM/psi 1/2 SR B, C, L, W, WOL 135 F, 155 F, 175 F, UL, C-UL, FM, NYC TFP351 200 F, 286 F, 360 F TY-B TY4251 (1) Pendent 3/4" 5 mm Bulb 8.0 GPM/psi 1/2 SR B, C, L, W, WOL 135 F, 155 F, 175 F, UL, C-UL, FM, NYC TFP351 200 F, 286 F, 360 F TY-FRB TY3133 (1) Upright 1/2" 3 mm Bulb 5.6 GPM/psi1/2 QR B, C, L 135 F, 155 F, 175 F, UL, C-UL, FM, NYC TFP356 200 F, 286F TY-FRB TY3231 (1) Pendent 1/2" 3 mm Bulb 5.6 GPM/psi1/2 QR B, C, L 135 F, 155 F, 175 F, UL, C-UL, FM, NYC TFP356 200 F, 286 F TY-FRB TY4133 (1) Upright 3/4" 3 mm Bulb 8.0 GPM/psi1/2 QR B, C, L 135 F, 155 F, 175 F, UL, C-UL, FM, NYC TFP356 200 F, 286 F TY-FRB TY4231 (1) Pendent 3/4" 3 mm Bulb 8.0 GPM/psi1/2 QR B, C, L 135 F, 155 F, 175 F UL, C-UL, FM, NYC TFP356 200 F, 286 F TY-L TY3113 (1) Upright 1/2" Solder 5.6 GPM/psi 1/2 SR B 165 F, 212 F, 280 F UL, C-UL, FM TFP350 TY-L TY3211 (1) Pendent 1/2" Solder 5.6 GPM/psi 1/2 SR B 165 F, 212 F, 280 F UL, C-UL, FM TFP350 TY-L TY4113 (1) Upright 3/4" Solder 8.0 GPM/psi 1/2 SR B 165 F, 212 F, 280 F UL, C-UL, FM TFP350 TY-L TY4211 (1) Pendent 3/4" Solder 8.0 GPM/psi 1/2 SR B 165 F, 212 F, 280 F UL, C-UL, FM TFP350 TY-FRL TY3123 (1) Upright 1/2" Solder 5.6 GPM/psi1/2 QR B, C 165 F UL, C-UL, FM, NYC TFP355 TY-FRL TY3221 (1) Pendent 1/2" Solder 5.6 GPM/psi1/2 QR B, C 165 F UL, C-UL, FM, NYC TFP355 TY-FRL TY4123 (1) Upright 3/4" Solder 8.0 GPM/psi1/2 QR B, C 165 F UL, C-UL, FM, NYC TFP355 TY-FRL TY4221 (1) Pendent 3/4" Solder 8.0 GPM/psi1/2 QR B, C 165 F UL, C-UL, FM, NYC TFP355 Sprinkler Finish Legend: B = Brass; BB = Bright Brass; C = Chrome; L = Lead Coating; P = Polyester Coating (White is standard); Wh = White; W = Wax Coating (for 135 to 212 ); WOL = Wax Coating over Lead (135 to 212 ) Hazard Legend: LH = Light Hazard; OH = Ordinary Hazard; All = Any Hazard Response Legend: SR = Standard Response; QR = Quick Response; FR = Fast Response (1) Intermeiate Level with Shield * Separately ordered Shields/Guards. design parameters installation instructions, care and maintenance guidelines, and our limited warranty. 11

WORLD HEADQUARTERS Tyco Fire & Building Products 451 N. Cannon Avenue Lansdale, PA 19446 USA Phone: 215-362-0700 Toll-free: 800-523-6512 Fax: 215-362-5385 Technical Services Toll-free: 800-381-9312 Fax: 800-791-5500 REGIONAL HEADQUARTERS Tyco Fire & Building Products Europe & Middle East Kopersteden 1 P.O. Box 198 7500 AD Enschede The Netherlands Phone: 31-53-428-4444 Fax: 31-53-428-3377 Asia & Australia No.45 Tuas Avenue 9 Singapore 639189 Phone: 65-6743-3212 Fax: 65-6743-9181 www.tyco-fire.com TYCO is a registered trademark of Tyco International Services GmbH, and is used under license by Tyco Fire & Building Products and its affiliates in the United States and other countries. All brand names, product names, or trademarks belong to their respective holders. Tyco Fire & Building Products reserves the right to change product design and specifications without notice. Copyright 2008 Tyco Fire Products LP. All rights reserved. Printed in USA / VIG / 5M / TF -2008009 2/08