Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Similar documents
Connected Plant. SMARTLINE TRANSMITTERS So Smart, They Make Life Easy

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

Field Solutions. Accurate and Reliable Measurement

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

Improving the Performance of Power Plants Worldwide

Successful Applications Using ISA100 Wireless Technology

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

2015 Honeywell Users Group Europe, Middle East and Africa

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

Life Sciences Solutions. Better Solutions. Faster Results.

Section B Field Instruments

Rosemount 3051S MultiVariable Transmitter

PROCESS CONTROL COURSES

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

SAFETY ON A BROADER SCALE Safety and security for people, processes, plants, communities and environment

Safety Instrumented Systems The Smart Approach

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Terminal Automation Solutions SmartRadar FlexLine Global Experience. Locally Applied.

THE VALUE IS IN THE SOFTWARE

Certification Report of the ST3000 Pressure Transmitter

Terminal Automation Solutions

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Certification Report of the ST 3000 Pressure Transmitter with HART 6

L automazione al servizio della manutenzione

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

Protect your investment with Safety Manager

STOCEXPO March Antwerp, Belgium Honeywell Stand E22

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

DynAMo Alarm & Operations Management

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

The evolution of level switches and detectors

Engineering Guideline. pac- Carriers Type Universal

operational excellence Solutions for

Controllers, Indicators & Set Point Programmers

Field Products. Solutions for Improved Thermal Process Performance

SLG 700 SmartLine Level Transmitters Guided Wave Radar Safety Manual 34-SL Revision 4.0 December 2017

Presenter: Chris Morse Honeywell

SECTION Fluorescent Dissolved Oxygen Measuring System

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Andrew Brodie 26 September 2017 DISCOVER THE FASTER AND SCALABLE VERSION OF THE ENHANCED CONTROLEDGE HC900 FOR A SAFE AND PROFITABLE PLANT

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

SUPREMATouch. Modular Fire & Gas Detection System

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Temperature Solutions Line Card

The Professionals in Instrument Technology

SUPREMATouch. Modular Fire & Gas Detection System

B. M/s. Yokogawa and C. M/s. Honeywell

Advanced HART Diagnostic Suite

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Practical Distributed Control Systems (DCS) for Engineers & Technicians. Contents

Products Overview. Your trusted partner in process instrumentation

Temperature measurement with SITRANS T siemens.com/processinstrumentation

FDT DTM and eddl. Technology Overview Peter Overgaauw - Honeywell

ENRAF SERVO LEVEL GAUGE

Ronan Model X96S Series Density System

Figure 1 DirectLine DL423 Sensor. Description, continued

FUNCTIONAL SAFETY MANUAL

XYZ XYZ XYZ XYZ XYZ XYZ. Energy Utility Based billing for Individual Tenants. Comprehensive Base Station Monitoring. Diesel Generator Monitoring

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Powerful intelligence. Breakthrough functionality. SV2 Series Intelligent Safety Shut-off Valve

Industrial Wireless Enabling Safety

Rosemount 3051S Electronic Remote Sensors

Assembly. Host Sub-D Alarm

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

Safety lnstrumentation Simplified

1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process.

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Tasmanian supplier of high quality instrumentation, control and electrical equipment for all industries. Mining, Food and Beverage, Water and

WW HMI SCADA-04 Discover the new Situational Awareness Library in InTouch 2014

SECTION Free/Available Chlorine Analysis System

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

L automazione al servizio della manutenzione nell industria di processo

STEAMPAK Series BurnerPAK BMS Burner Management Systems

OPTIMIZING YOUR TECHNOLOGY INVESTMENT WITH SERVICE AND SUPPORT

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

Safety in the process industry

Instrumentation and Analytical Sales, Service & Training

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Intelligent sensing for every temperature and condition

Siemens Process Automation End-user Summit- 2011

Ronan Model X96S Series Weighing System

Instrumentation Products and Applications

Next Generation Alarm Management With DynAMo Alarm and Operations Management

Process Solutions. Solution Note. HC900 and OneWireless. Background. Applications. Key issues. Tanks in explosion-proof areas.

DeltaV SIS TM. for Process Safety Systems Smart Safety Loops. Reliable Process.

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Transcription:

Smarter Field Instrumentation Life Cycle Management Ray Rogowski Global Marketing PMC Instruments

Smart LifeCycle Management Pressure Temperature Radar Remote Seal Flange Mount User Interface Buttons Single Input Multiple Inputs Wireless Window Cap Comm Board Terminal Block Rear Cap Smart Multi- Variable Display (Basic/ Advanced) Sensor ST 800 Platform Analytical future Minimizing Project Risk and Schedule, Operation Cost 2 2015 Honeywell International All Rights Reserved

Lifecycle Challenges Planning: Range, Different types of Sensors, Accuracy, Isolation, Grounding, Certification, Protocol, Approval, Spare philosophy Procurement Technical vendor evaluation and model selection of options Project Execution and Commissioning: DCS integration, software, tools, loop test, configuration, security of configured data Long term Operation and Maintenance: Protocol support, easy to integrate, software tool, diagnostic Minimize Risk Minimize Schedule Minimize Cost 3 2015 Honeywell International All Rights Reserved

Typical Device Selection Parameters Cost Range SIL 2/SIL3 Compliance Certifications Mounting Sensor selection Field Transmitters Accuracy User Friendly Isolation Protocol Stability Typical Device Specific Versus Lifecycle Approach 4 2014 Honeywell International All Rights Reserved

Bringing LEAP Benefits To Field Instruments Address Last Minute Changes Up to 30% reduction Reduce Start-Up Time Up to 50% on loop check Reduced Engineering 60% Config & set-up Universal Range Simple Modularity Universal xmtr wiring Auto identification Preconfigured online Smart ordering tool Cloud Engineering Platform for FI EPC Honeyw ell Custom er Universal Transmitters 1. Multiple calibration ranges 2. Hot Swap modules Address last minute changes Unique EPKS Integration 1. Fully eliminate wiring checks 2. Auto device Identification 3. Local transmitter interface Cloud Application Tool 1. Error free ordering 2. Pre configured to install 3. Online collaboration Reducing Project Risk and Schedule

Universal Transmitters How is SmartLine Better? Multiple Factory Calibration Ranges Reduce project risk eliminate recalibration or rip and replace Minimize inventory and inventory complexity up to a factor of 3 Traditional SmartLine 1000mmwc 1200mmwc 1500mmwc Trial run Startup Ramp up Three in one 6 2015 Honeywell International All Rights Reserved

Universal Transmitters How is SmartLine Better? Universal Transmitter Wiring Eliminates all potential wiring re-work Faster Installation, Startup and Commissioning + + Loop Test (HART ) + Field Wiring** or Either connection will OPERATE correctly + + Loop Test (HART) + Field Wiring** 7 2015 Honeywell International All Rights Reserved

Universal Transmitters How is SmartLine Better? SmartLine Modularity Modularity Simplifies Field Installation & Replacement Specify only the minimum required Simple field upgrades Minimize end of project change cost Hot swap module change out; even in Div I. Simple and easy Modular replacement Minimize spare inventory, complexity and cost B a si c D is p la y Advanced Display 8 2015 Honeywell International All Rights Reserved

Unique EPKS Integration How is SmartLine Better? Smart Connected User Experience Transmitter Messaging + Maintenance Mode Indication Tamper Alerts Extended Diagnostics & FDM Comprehensive EPKS Integration Testing + 9 2015 Honeywell International All Rights Reserved

Unique EPKS Integration How is SmartLine Better? Transmitter Messaging + Maintenance Mode Right work, right instrument, safe mode Quickly identify the right device and task Avoid costly and time consuming errors Faster Loop check 10 2015 Honeywell International All Rights Reserved

Unique EPKS Integration How is SmartLine Better? Unique Tamper Alerts and Reporting Quickly identifying costly configuration changes SmartLine reports transmitter tamper attempts Attempted configuration changes Write-protect disablement Records event for investigation 11 2015 Honeywell International All Rights Reserved

Unique EPKS Integration How is SmartLine Better? Field Device Manager Plant Area Views Faster set-up and commission Quickly identify abnormalities High level or detail summary status at a glance 12 2015 Honeywell International All Rights Reserved

Unique EPKS Integration How is SmartLine Better? Comprehensive Integration Testing Problem free integration Faster Checkout, commission, startup Single DCS + instrumentation supplier Expect seamless compatibility Expect compatible tools, templates, work packages Expect lower risk and schedule + 13 2015 Honeywell International All Rights Reserved

Reduced Engineering How is SmartLine Better? Cloud Configuration Tools Up to 60% reduction in specification time Eliminate duplicate engineering effort Eliminate errors Simple out-of-box experience from specification start to installation Minimize FAT/SAT/Commissioning= Honeywell order system Factory 14 2015 Honeywell International All Rights Reserved

Reduced Engineering How is SmartLine Better? Field Setup Tools Match to Skills Guided novice user experience Organized and expert mode Graphical tool for advanced configuration Live Echo Curve 15 2015 Honeywell International All Rights Reserved

Honeywell Field Instrumentation Pressure Transmitters Absolute pressure transmitters Differential pressure transmitters Gauge pressure transmitters Remote seal transmitters Flanged / Level transmitters Multivariable transmitter Remote meters 16 2015 Honeywell International All Rights Reserved

Honeywell Field Instrumentation Temperature Transmitters Flexible Mounting Options - Field Mount - Single/Dual Compartment - Head Mount - DIN Rail Mount Single/Dual Input HART/DE/FF/ Profibus Protocol SIL2/3 Certification 17 2015 Honeywell International All Rights Reserved

Honeywell Field Instrumentation Level Transmitters GWR technology Liquid level and interface measurement SIL 2/3 and Overfill Protection HART and FF output Basis for future models Solids High Temperature and Pressure 18 2015 Honeywell International All Rights Reserved

Honeywell Field Instrumentation Flow Transmitters Magmeter Coriolis Mass Flow Vortex Shedding Clamp-On Ultrasonic 19 2015 Honeywell International All Rights Reserved

Honeywell Field Instrumentation Wireless Transmitters Absolute pressure transmitters Differential pressure transmitters Gauge pressure transmitters High Level Analog and Digital Universal Input (3) T, AI/DI/DO Valve Positioner HART Adapter Access points and routers Redundant Backbone Routers and Gateways 20 2015 Honeywell International All Rights Reserved

Planning and Procurement Reduce initial cost and complexity, provide flexibility Application Validation Tool validates transmitter selection for tank application. Online collaboration Modularity lets you pay for only what you need initially, and allows upgrades later Lower operating costs, avoid unplanned downtime & improve product quality Modularity reduces spare parts inventory and allows faster replacements Advanced display aids troubleshooting with up to 24-hour trend visibility Diagnostic summary view provides early problem detection** Total performance improves product quality through better control, faster response, and process static pressure & temperature compensation Operations ** Available through Honeywell s Field Device Manager Plant Lifecycle Project Execution Startup & Commission Reduce project startup time Transmitter messaging eliminates the need for two people to perform point-to-point verification Polarity insensitivity eliminates startup interruptions and rework due to polarity conflicts Lower maintenance costs, reduce repair time and enhance safety Modularity speeds repairs by avoiding complete device replacement and line breaks Transmitter messaging and maintenance mode indication helps avoid unit trips and provides additional communication between operations and field techs* Advanced display clearly provides diagnostic information, PV views and trending Platform approach across measurements minimizes training and support Maintenance * Available when used with Experion

Who says you can t have it all? At Honeywell, we say you can! Our SmartLine transmitter just got smarter! 22 2015 Honeywell International All Rights Reserved