PRODUCT IFORMATIO (*) IDOOR MODEL PKA-RP100KAL PACKAGED AIR CODITIOER OUTDOOR MODEL PUHZ-ZRP100VKA If function includes heating: Indicate the heating season the Function (indicate if present) information relates to. Indicated values should relate to one heating season at a time. Include at least the heating season Average (mandatory) cooling Warmer (if designated) heating Colder (if designated) Item symbol value unit Item symbol value unit Design load Seasonal efficiency cooling Pdesignc 10,0 kw cooling SEER 6,1 - heating/average Pdesignh 7,8 kw heating/average SCOP/A 4,0 - heating/warmer Pdesignh x kw heating/warmer SCOP/W x - heating/colder Pdesignh x kw heating/colder SCOP/C x - Declared capacity for cooling, at indoor temperature 27(19) and outdoor temperature Tj Declared energy efficiency ratio, at indoor temperature 27(19) and outdoor temperature Tj Tj=35 Pdc 10,0 kw Tj=35 EERd 3,7 - Tj=30 Pdc 7,3 kw Tj=30 EERd 5,3 - Tj=25 Pdc 4,7 kw Tj=25 EERd 7,6 - Tj=20 Pdc 4,2 kw Tj=20 EERd 10,2 - Declared capacity for heating/average season, at indoor Declared coefficient of performance/average season, at indoor Tj=-7 Pdh 6,9 kw Tj=-7 COPd 2,4 - Tj=2 Pdh 4,2 kw Tj=2 COPd 4,1 - Tj=7 Pdh 3,1 kw Tj=7 COPd 5,1 - Tj=12 Pdh 3,7 kw Tj=12 COPd 6,1 - Tj=bivalent temperature Pdh 7,8 kw Tj=bivalent temperature COPd 2,0 - Tj=operating limit Pdh 5,8 kw Tj=operating limit COPd 1,5 - Declared capacity for heating/warmer season, at indoor temperature 20 and outdoor temperature Tj Declared coefficient of performance/warmer season, at indoor Tj=2 Pdh x kw Tj=2 COPd x - Tj=7 Pdh x kw Tj=7 COPd x - Tj=12 Pdh x kw Tj=12 COPd x - Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd x - Tj=operating limit Pdh x kw Tj=operating limit COPd x - Declared capacity for heating/colder season, at indoor temperature 20 and outdoor temperature Tj Declared coefficient of performance/colder season, at indoor Tj=-7 Pdh x kw Tj=-7 COPd x - Tj=2 Pdh x kw Tj=2 COPd x - Tj=7 Pdh x kw Tj=7 COPd x - Tj=12 Pdh x kw Tj=12 COPd x - Tj=bivalent temperature Pdh x kw Tj=bivalent temperature COPd x - Tj=operating limit Pdh x kw Tj=operating limit COPd x - Tj=-15 Pdh x kw Tj=-15 COPd x - Bivalent temperature Operating limit temperature heating/average Tbiv -10 heating/average Tol -20 heating/warmer Tbiv x heating/warmer Tol x heating/colder Tbiv x heating/colder Tol x Cycling interval capacity Cycling interval efficiency for cooling Pcycc x kw for cooling EERcyc x - for heating Pcych x kw for heating COPcyc x - Degradation co-efficient cooling Cdc 0,25 - Degradion co-efficient heating Cdh 0,25 - Electric power input in power modes other than 'active mode' Annual electricity consumption off mode POFF 15 W cooling QCE 572 kwh/a standby mode PSB 15 W heating/average QHE 2763 kwh/a thermostat - off mode PTO(c/h) 80/40 W heating/warmer QHE x kwh/a crankcase heater mode PCK 0 W heating/colder QHE x kwh/a Capacity control (indicate one of three options) fixed Other items Sound power level (indoor/outdoor) LWA 65/69 db(a) staged Global warming potential GWP 1975 kgco2eq. variable Rated air flow (indoor/outdoor) - 1560/6600 m3/h MITSUBISHI ELECTRIC CORPORATIO SHIZUOKA WORKS Contact details for obtaining 3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, Japan more information E-mail: melshierp@nb.mitsubishielectric.co.jp (*) This information is based on the "product information requirement" in COMMISSIO REGULATIO (EU) o206/2012.
TECHICAL DOCUMETATIO ( 1 ) IDOOR MODEL PKA-RP100KAL 365H1170W295D (mm) PACKAGED AIR CODITIOER OUTDOOR MODEL PUHZ-ZRP100VKA 1338H1050W330D (mm) Function cooling heating The heating season Average (mandatory) Warmer (if designated) Colder (if designated) Capacity control fixed staged variable Item Seasonal efficiency ( 2 ) symbol value unit cooling SEER 6,1 - heating/average SCOP/A 4,0 - heating/warmer SCOP/W x - heating/colder SCOP/C x - Energy efficiency class cooling SEER A++ - heating/average SCOP/A A+ - heating/warmer SCOP/W x - heating/colder SCOP/C x - Other items Sound power level (indoor/outdoor) LWA 65/69 db(a) Refrigerant - R410A - Global warming potential GWP 1975 kgco2eq. identification and signature of the person empowered to bind the supplier Hideyo Tamura Manager, Packaged Air Conditioners Quality Control Section MITSHUBISHI ELECTRIC CORPORATIO SHIZUOKA WORKS (1) This information is based on COMMISSIO DELEGATED REGULATIO (EU)o626/2011. (2) SEER/SCOP values are measured based on FprE 14825:2011: Testing and rating at part load conditions and calculation of seasonal performance.