DTA04. Motor thermistor relay. Benefits. Description

Similar documents
DTA. Motor thermistor relay. Benefits. Description

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Two-Channel Gas Controller

Motogard. Over Temperature Protection System. Installation Instructions

Oxygen (O2) Single-Point Gas Detection System

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Operating Manual MS220KA and MSR220KA

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

HTC-915-CONT. Heat-Trace Control system

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Operating Instructions. For. Alarm Control Module. Model SSR 500

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Process Alarm Module RTA 421

4 & 8-POINT ANNUNCIATORS Instruction Manual

PolyGard 2-channel Gas Controller MGC-03

Overload relays. General descriptions. Configuration of the front

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Operating Manual MS220DA

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

02/11/2015

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

ACS-30-EU-EMDR- 10-MOD

I/A Series 716C 1/16 DIN Temperature Controller

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Multi-Gas-Controller MGC2

/8 DIN Level Indicator

Danfoss gas detection unit Type GD Heavy Duty

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

GasGard 100 Control System

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Ordering Key. Dielectric strength

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

02/11/2015

RSGD. Three phase AC motor soft starter. Benefits. Description

Tower & Obstruction Lighting

Model A1600 Series Annunciator

SACE PR021/K SIGNALLING UNIT

Operating Manual MSF220V(VU)

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Danfoss gas detection units

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Process & TeMPerATUre UniversAl input DigiTAl MeTers

RE-PR3-E-27 3-Phase Panel Mount 27kW

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Monitoring Devices 11/1

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Power Supply Display Module PSDM. Installation and Operation Manual

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

SECTION LOW VOLTAGE LIGHTING CONTROLS

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Danfoss gas detection units

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

UDC100 Universal Digital Controller Specifications

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

Instructions for the fan motor control system, SILVER C

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

AO Annunciator Module

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

SCHMIDT LED Measured Value Display MD Instructions for Use

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

ISIS SAFETY SYSTEM Installation guide

Interface and EOL Modules 8

MSP1000 Motor Protection Relay

Temperature Controllers

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

GL-CO-RFG Channel Gas Leak Alarm System

VAMP 120 & 121. Arc flash detection units. Product picture

ACS-30-EU-VIA-DU-20-MOD

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Tower & Obstruction Lighting Controls

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Combustible Gas Detection and Control System

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

LC2200 Level Controller Installation and Maintenance Instructions

Operating Manual. Gasgard 100 Control System. Order No.: /00. MSAsafety.com

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

DIESEL Engine Fire Pump Controllers Features

Transcription:

Motor thermistor relay Benefits High operating safety. The thresholds are determined by the Motor PTC. Beyond the specified temperature the output stops the motor/s. Save time and costs.there is no need to connect other additional and expensive controllers. Ensure continuous production process in your plant. This type of controller allows limitation of false alarms which may be the cause of useless interruptions of production systems. Two outputs. The 2 ouputs provide, besides interrupting the the Motor supply, an additional signal for a lamp, PC or PLC. Bi-colour front LED. These devices indicate alarms for temperature and PTC. Description is a motor thermistor monitoring relay. Through the motor internal PTC or PTCs the DTA detects when one or more motor windings are exceeding the maximum operating winding temperature. The PTC type installed in the motor is different according to the motor insulation temperature. The temperature triggering threshold is detemined by the PTC Type. The relay is equipped with 2 outputs which operate in a complementary mode. The can be set to operate as MANUAL or AUTO reset. When set to manual, the front LED will notify when the motor temperature is back to normal avoiding to try to restore operation uselessly. Applications This product is extremely suitable for pumps temperature monitoring. It can be useful in all applications where motors are used especially where overloads are frequent and may cause motor damages: pumping stations, water treatment, conveyors, material handling, HVAC, chillers. etc. 19/09/2017 DS ENG 1

Structure F A G B C D E A G F Element Component Function A Power Supply terminals A1 ( + or L ) A2 ( - or N ) B PTC input Up to 6 PTCs in series can be connected C TEST / RESET pushbutton When no overtemperature alarm is present, this double function pusbutton, operates as TEST by simulating the PTC overtemperature: motor stops as long as pushbutton is pressed, as soon as pushbutton is released the normal operation is restored. The pushbutton operates as RESET when the motor had been stopped by overtemperature, the setting is for MANUAL reset and the LED shows the "Ready for reset" situation. D Information LED Green ON steady: no alarm Red ON steady: over-temperature alarm Fast Red blinking: open circuit PTC Slow Red blinking: short-circuit Red and Green alternate: ready for reset E Remote RESET pushbutton terminals To configure the device as Autoreset they shall be jumpered F Output 1 terminals SPST electromechanical relay. During normal operation the conctact is closed, it opens when an alarm is triggered G Output 2 terminals SPST Electromechanical relay. Normally open contact, it closes when an alarm is triggered 19/09/2017 DS ENG 2

Features General Material PA66 or Noryl Assembly DIN rail mounting (According to EN 50022) Protection grade IP20 Weight 150 g Terminals Screw terminals. AWG30 to AWG14 (0.05 mm 2 to 2.08 mm 2 ) stranded or solid 22.5 mm [0,885 ] 84 mm [3,307 ] 99.5 mm [3,917 ] Power supply Power supply 18 to 265 Vac/Vdc: 45 to 65 Hz, or dc Consumption 3VA ( AC supply ) / 1.5W ( DC supply ) Environmental Working temperature -25 C to 60 C (-13 F to 140 F) Storage temperature -40 C to 80 C (-40 F to 176 F) Relative humidity 5-95% non condensing Pollution degree 2 Operating max altitude 2000 m amsl ( 6560ft ) Salinity No saline environment UV resistance No UV exposure 19/09/2017 DS ENG 3

Compatibility and conformity Standard compliancce EN60255-6 Approvals (UL 508, CSA 22.2, ) CE Marking L.V. Directive EN60947-5-1, EMC Directive EN 60947-8 Inputs Measuring ranges Resistance measuring Input from a series of 1 to 6 PTC according to EN44081 or IEC34-11-2 Cable length Max. 600m (wire 1.5mm 2 ) or 200m (wire 0.5mm 2 ) Over-temperature trip > 3600 Ω Over-temperature reset < 1580 Ω Short-circuit protection 14 Ω (reset 16Ω) Open circuit detection 20 kω (reset < 18 kω) Switching frequency < 1Hz Refresh time 500 ms Alarm detection Outputs Type Logic Output 1 Output 2 Contact rating 2 x SPST NO electromechanical relay De-energized on alarm Energized on alarm NEMA B 300 240 Vac AC1 8 A @ 250 Vac DC12 5 A @ 24 Vdc AC15 2.5 A @ 250 Vac DC13 2.5 A @ 24 Vdc Insulation Inputs to output 1 Inputs to output 2 Inputs to supply Output 1 to supply Output 2 to supply Output 1 to output 2 Basic Insulation 19/09/2017 DS ENG 4

Operating diagram When the temperature of one of the PTCs in series is exceeded output relays will both switch: relay 1 is deenergized and output relay 2 is energised. The LED is ON red. When the motor normal temperature is restored, if the is wired as "Auto reset", the operation is restarted automatically. If the is wired as manual reset when the normal motor temperature is restored the LED starts blinking alternatively red and green indicating it is ready for reset. When the front or the remote RESET buttons are pressed the operation starts again. The LED turns to green and the output relays switch back to original position. Power supply 3600 1580 Auto reset Relay 1 ON Relay 2 ON Manual reset Reset button Relay 1 ON Relay 2 ON 19/09/2017 DS ENG 5

Connection Diagrams L1 + or L L2 L3 STOP N PE START A1 1 3 5 A2 2 4 6 RESET r1 1 r2 14 22 A1 13 21 A2 T1 T2 T1 T2 PTC M1 M 3 +t - or N A1 L2 L1 A2 Code Description Main contactor START Machine start pushbutton STOP Machine stop pushbutton RESET Remote reset button L1 Green Lamp (OK) 1 For Auto Reset operation r1 and r2 shall be jumpered 19/09/2017 DS ENG 6

References Order code DM24 COPYRIGHT 2016 Content subject to change. Download the PDF: www.productselection.net 19/09/2017 DS ENG 7