LQ AQ SQ. Air-cooled and water-cooled portable chillers

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Outstanding Performance; Application Flexibility

Central Chillers TS Series

NQ Series Portable Chillers

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

OACS Outdoor Air-Cooled Central Chillers

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

GP SERIES Packaged Chillers

MAC N-407 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

EP1 Series Portable Chillers

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MACH N-407 Heat Pump Air-Cooled Chiller

EQ Series Portable Chillers

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

.2 Section Waste Management and Disposal.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Temptek Auxiliary Equipment

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Call us today! (800)

Call us today! (800)

Installation, Operation and Maintenance Manual. LQ Series Portable Chillers

Call us today! (800)

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

SECTION ROTARY-SCREW WATER CHILLERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Installation, Operation and Maintenance Manual. LQ Series. Portable Chillers 7 to 40 Tons

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Please record your equipment s model and serial number(s) and the date you received it in the spaces provided.

VariCool VAV Engineering Guide

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

MAC-120HE-03 Air-Cooled Chiller

Koolman Air-Coolded Water Chiller With Heat Pump Option

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

PACKAGED AIR COOLED Product Data Catalog

CHILLER. Operator s & Installation Manual

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

water to water heat pumps

PDF Created with deskpdf PDF Writer - Trial ::

MEDICAL CHILLER SYSTEMS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

30GT FLOTRONIC AIR-COOLED CHILLERS

CF-10A shown CF- 2A Shown

Energy-Saving Industrial Water Chillers

PARAGON Commercial Refrigeration Controls

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Liebert CSU3000 Chiller

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Circulating Water Temperature Controller

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION AIR COOLED WATER CHILLERS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

REFRIGERATION PRODUCTS

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

ULTIMATE ENERGY SAVING TECHNOLOGY

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

WO P NF L M 407c Spec Submittal

WO P NF L M 407c Spec Submittal

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Ultimate energy saving technology

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

RQE Series Temperature Controllers

Temperature Controllers

Air-Cooled Water Chiller Air-Cooled Water Chiller with Heat Pump Option 3~30 Tons

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Ultimate energy saving technology

GUIDE SPECIFICATIONS AQUARIUS ii

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

MODULAR CHILLER. R410a R22

Installation, Operation and Maintenance Manual. TC Series. Centrifugal Chillers 60 to 180 Tons. Copyright 2009 Thermal Care

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

SENTRA Series Water Unit

AIR COOLED PACKAGED CHILLER

REFRIGERATED AIR DRYERS

Refrigerated Air Dryers

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

GUIDE SPECIFICATIONS AQUARIUS ii

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

C13-Series Engineering Guide

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Transcription:

Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp {0.2 to 2.2 kw} for air-cooled units, and 1 to 3 Hp {0.7 to 2.2 kw} for water-cooled units, the EP1 Series boasts nonferrous construction (evaporator, pump, reservoir and piping) to resist corrosion, a compact footprint with easy-to-access interior, and a control that provides precise temperature control along with extensive diagnostics. Quality Construction; Reliable Operation Model EP1A-01 (air-cooled, 1 ton capacity) With more standard features than the competition, the EP1 Series Portable Chillers are designed for indoor use in industrial manufacturing locations. oth water-cooled and air-cooled units ship with a full refrigerant charge, eliminating the need for charging before operation. This saves time and money, right out of the box. Units with a remote air-cooled condenser ship with a nitrogen charge. All EP1 Chillers are manufactured using painted, heavy-gauge steel to form a cabinet with tool-free access. Conair s innovative microprocessor control system is designed specifically for portable chiller applications. The easy-to-use operator panel utilizes a four-plug wiring design which allows the entire control board to be replaced in minutes. Dependable chiller performance Designed with a comprehensive group of built-in protective features, the EP1 assures dependable performance with minimum downtime. A 2.5 minute anticycle timer prevents excessive compressor cycling. A low-load thermostat extends operating time at idle and low-load conditions and a non-cycling low pressure switch specifically designed for portable chillers helps protect the compressor from damage and unnecessary wear. More standard features The EP1 Series Portable Chillers come equipped with standard features that other manufacturers would offer as options. Features which guarantee long life, simple operation, and quality end results are included as standard with this series. Energy efficient Constructed with the energy efficient and reliable rotary compressor (1 ton unit) and the energy efficient and industrial scroll compressor (2 and 3 ton units), these compact chillers save you money by saving energy. Extensive warranty In addition to Conair s standard one year parts and labor warranty, the EP1 comes with a five year parts warranty for the microprocessor, and a lifetime $175 exchange policy after the initial five year warranty period.

Control Features Standard control features: Two easy-to-read LED digital displays show Actual and Setpoint temperatures Manual reset of safeties from front panel eliminates need to open chiller cabinet Thirty minute deviation delay stops nuisance alarms during start-up and setpoint changes Compressor cycling delay prevents short cycling PID control program algorithm provides ± 1 F / C accuracy High/low temperature deviation alarm Power failure indicator signals brown out Easily switches between F and C readouts Low-flow protection Diagnostic lights that indicate: no flow, high and low refrigerant pressure, freezestat, over and under setpoint, pump on, compressor on, partial load, probe fault and optional low water level and water make-up Optional control features: Hand-held, remote control operator panel SPI communications Audible alarm From Process temperature readout Remote alarm contacts Remote on/off contacts High Quality Electrical Components All Conair EP1 Series Portable Chillers come standard with a NEMA 1 electrical enclosure to protect the microprocessor and chiller wiring. High quality electrical components meet IEC electrical standards and are fully tested before shipping. Disconnect switches, C-UL 508A industrial control panel are affordable options.

Features 03 01 Stainless steel brazed plate evaporator provides high efficiency heat transfer 02 Insulated polyethylene reservoir with removable cover 04 01 02 03 Water-cooled units have cleanable shell-and-tube condensers and a water regulating valve for head pressure control 04 05 Efficient and reliable one ton rotary compressor or two and three ton scroll compressors 05 Process pump with pressure gauge Internal view of the EP1W-03 Mechanical features Electronic hot gas bypass for stable capacity control Air-cooled units have copper tube / aluminum finned condensers and includes air inlet filter (optional on-one-ton unit) Remote condenser units include a galvanized steel remote condenser with fans and copper tube / aluminum fin coils with a nitrogen holding charge Electrical features Compressor, pump and condenser fan starters mounted and wired to motors Single-point main power block for simple wiring connection Freezestat safety switch with solid state sensor Encapsulated high and low refrigerant pressure safeties Pressure or flow switch interlocked with compressor Other features Nonferrous construction of evaporator, pump, reservoir and piping to resist corrosion Microprocessor controller to provide diagnostic and accurate temperature control Air-cooled condenser is generously sized for ambient temperatures up to 115 F {46 C} Internal insulated polyethylene reservoir comes with large capacity and a removable top Condenser fan discharges air quietly through the top of the unit Hot gas bypass provides accurate capacity control and extends compressor life Process Y-strainer protects the evaporator from contaminants in the water External sight glass, fill connection and drain connection Smaller footprint that takes up less floor space Easily removable side panels allow quick access to interior components

Pump Curves Water temperature at 50 F {10 C} EP1 Series Pump Curves (50 Hz) Flow (l/min) 70 0 20 40 60 80 160 ¼ Hp positive displacement pump (EP1A-01) 60 140 50 120 2 Hp, 2-stage 100 Pressure (psi) 40 30 3 Hp 2 Hp 80 Pressure (ft) 60 1 Hp 20 40 10 20 0 0 0 5 10 15 20 25 Flow (gpm) Specification Notes Pump availability: 0.25 Hp {0.19 kw} standard for 1.0 ton; 1 Hp {0.75 kw} standard for 2 and 3 ton; 2 Hp, 2 Hp {1.49 kw} 2-stage and 3 Hp {2.24 kw} optional for 2 and 3 ton. Pump curves do not reflect pressure drops due to internal piping. These pump curves are non-overloading using the service factor of the motors. Specifications may change without notice. Check with your Conair representative for the most current information.

Specifications Air cooled Pump pressure gauge 1/2 inch FPT water make-up (option) A water supply water return Water level sight glass Front view (EP1A) C Side view (EP1A) Rear view (EP1A) Water cooled / remote condenser indoor unit A Pump pressure gauge water supply Water level sight glass 1/2 inch FPT water make-up (option) 1 inch FPT condenser water out 1 in. FPT condenser water in water return Front view C Side view Rear view Remote condenser outdoor unit A Pump pressure gauge water supply Water level sight glass 1/2 inch FPT water make-up (option) 7/8 inch discharge line 7/8 inch liquid line water return Front view C Side view Rear view

Specifications Models EP1A-01 EP1A-02 EP1A-03 EP1W-02 EP1W-03 EP1R-03 (Indoor unit) Condenser Air cooled Water cooled Remote Performance characteristics EP1R-03 (Outdoor unit) Cooling capacity tons* 1.0 2.0 3.0 2.2 3.3 3.0 N/A Setpoint range F { C} 20 to 65 {-7 to 18} N/A Refrigerant Air flow ft 3 /min 1110 1585 2470 N/A 6750 Condensed water flow gpm {l/min} N/A 7 {27} 10 {38} N/A Reservoir holding capacity gal. {l} 3 {11} 11 {42} N/A Condenser fan Hp {kw} N/A 0.50 {0.40} Pump performance Pump motor size Hp {kw} 0.25 {0.18} 1 {0.75} N/A Pump flow gpm {l/min} 2 {7.5} 5 {18.9} 7 {26.4} 5 {18.9} 8 {30.2} 7 {26.5} N/A Pump pressure psi {bar} 80 {5.5} 39 {2.68} 38 {2.62} 39 {2.68} 37 {2.55} 38 {2.6} N/A Dimensions inches {mm} A - Height 33.125 {841} 41.500 {1054} 36.625 {930} 41.440 {1053} - Width 18.625 {473} 24.000 {610} 38.750 {984} C - Depth 27.625 {702} 39.625 {1006} 45.750 {1162} Voltages MCA 230/1 phase/60 Hz 11.8 N/A 3.0 230/3 phase/60 Hz N/A 17.0 21.5 15.4 18.9 N/A 460/3 phase/60 Hz N/A 9.0 11.9 8.2 10.6 N/A 575/3 phase/60 Hz N/A 7.2 9.6 6.6 8.5 N/A Weight lb {kg} Shipping 255 {116} 420 {191} 430 {195} 420 {191} 430 {195} 565 {256} Specification Notes * ased on the 50 F {10 C} water to the process, single pump selections, a maximum of 95 F {35 C} ambient air and 60 Hz. Adjust capacities up 2% per degree above 50 F {10 C} to a maximum of 65 F {18 C}. Adjust capacities down 2% per degree below 50 F {10 C} to a minimum of 20 F {-7 C}. Capacities are ± 5% based on the compressor manufacturer s ratings and are subject to change without notice. Consult with a Conair representative for other conditions. Capacities change depending on selected options. Standard set point range is 20 F to 65 F {-7 to 18 C}. To extend range to 20 F to 80 F {-7 to 27 C} the CPR valve option is required. Remote condenser operation requires both indoor and outdoor unit. Specifications may change without notice. Consult a Conair representative for the most current information. How it Works R407C High pressure switch HP Compressor Air, water or remote condenser Low pressure switch LP Thermal expansion valve Filter Hot gas bypass valve Y-strainer FZ FS Guage Pump Process fluid flow switch Evaporator Supply process temperature Tank Optional make-up water solenoid valve ypass valve Optional return process temperature Make-up water From process To process Process circulation: Process fluid enters through the From process connection to the reservoir tank. The pump draws water from the tank and moves it through the evaporator. Fluid is chilled and exits through the To process connection. Refrigerant circulation: The evaporator extracts heat from the process fluid. Vaporized refrigerant travels from the evaporator to the compressor, where it is com-pressed. The high-pressure vapor travels to the condenser. Air or water removes heat from the vapor, condensing it to liquid. This liquid is metered back to the evaporator by the expansion valve (TXV).