INSTALLATION INSTRUCTIONS

Similar documents
Forced air distribution kit VA4460

INSTALLATION INSTRUCTIONS

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

DaVinci Heat Exchanger Touch-Screen Version

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

Questions on Installation? Call: 800.GE.CARES (US) WARNING RISK OF FIRE TOOLS YOU WILL NEED 4" DIA. METAL DUCT (RECOMMENDED)

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION OF THE OPTIONAL HOT WATER LOOP KIT FOR PREHEATING OF DOMESTIC WATER PA08550 MAX CADDY FURNACE

INSTALLATION INSTRUCTIONS OF THE OPTIONAL HOT WATER LOOP KIT FOR PRE-HEATING DOMESTIC WATER ALTERNA FURNACE

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

DaVinci Heat Exchanger

INSTALLATION INSTRUCTION

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Installation Instructions

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

Installation Electric Dryers Instructions 01

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

IMPORTANT SAFETY INFORMATION:

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

ST. KITTS CEILING FAN

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

e Bath Fan with Light User s Guide

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

Questions on Installation? Call: 800.GE.CARES (US) WARNING RISK OF FIRE 4" DIA. METAL DUCT (RECOMMENDED) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions

Installation Instructions

High-Density Industrial

Concepts Serving Systems

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Carbon Rack Enclosure

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Easy installation in both new construction and retrofit

Rotary XL (558 Series) and Classic (548 Series)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

e Bath Fan with Light User s Guide

Installation Instructions

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

REQUEST FOR ALTERNATE TO BID (SUBMITTAL FORM ATTACHED)

Bathroom Exhaust Fan

Hanson LED C e i l i n g F a n

Instructions. Duct Mount Accessory Q Rev: 11/

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

FLUSH WATER SAVER DUAL FLUSH KIT

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

REASSEMBLY; 2007 MY CAMRY [01...

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

Pellet Vent INSTALLATION INSTRUCTIONS

ZC Kit AGP Pellet Insert

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

CUSTOMER SERVICE. Toll-free:

Nest x Yale Lock Installation and Programming Guide. Back button Check (Set / Continue) Keypad

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

PVK-80 Power Vent - Installation Instructions -

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

ENERVEX MFD MECHANICAL FIREPLACE DAMPER

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Sunstruck Installation Manual

ITEM # , CARATUK RIVER CEILING FAN MODEL #40046, 40303

C Series. Cool Surface System INSTRUCTION MANUAL SIDE VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

Installation Instructions

CEILING FAN OWNER'S MANUAL

installation manual built-in refrigeration

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Easy installation in both new construction and retrofit

HE220, HE260 Humidifier Installation Kit

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

π H-2549 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

READ AND SAVE THESE INSTRUCTIONS

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

Model Flex-95 (E.P.A. Phase II Approved)

e Bath Fan with Light User s Guide

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

DOUBLE DISHDRAWER TM DISHWASHER

COOKER HOOD USER MANUAL

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

CEILING FAN OWNER'S MANUAL

LONG BEACH 52" outdoor fans

Transcription:

FORCED AIR DISTRIBUTION KIT AC01363 INSTALLATION INSTRUCTIONS THE FORCED AIR DISTRIBUTION KIT (AC01363) WITH HEAT ACTIVATED SYSTEM, CAN BE INSTALLED ONLY WITH THE GRAVITY KIT - MODERN STYLE (AC01385), AND ARE SOLD SEPARATELY. This manual is available for free download on the manufacturer s web site. It is a copyrighted document. Re sale is strictly prohibited. The manufacturer may update this manual from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any manual obtained from unauthorized sources. 45735A Printed in Canada 24-02-2015

This forced air kit contains the following parts: PL66622 44142 49027 49090 1x 1x 4x 1x PL66623 + 44028 60201 30414 44131 1x 1x 1x 1x Other accessories required (not included): AC01350 Insulated flexible aluminized trilaminated pipe 6 x 25 Air register 2

Tools required for installation: Flat Screwdriver Robertson Screwdriver Phillips Screwdriver Utility knife Cutting pliers Ratchet with 11/32" (9mm) hexagonal socket FORCED AIR KIT AC01363 Warning In Canada, the connection of A forced air kit to a furnace duct is prohibited, unless local building codes allow it. This type of installation is allowed in the USA (UL 391 Standards). However, do not connect any hot air ducts to the cold air return. If the forced air kit pipe is to be connected to a furnace hot air distribution system, a backflow shutter (#6, not included) must be installed between the forced air kit fan and the central system hot air duct. To favor an optimum air distribution, it is recommended to connect the forced air kit pipe to the furnace duct using an angled connecter oriented towards the air outlet. If the fireplace is in a small room, the fan can be used to distribute excess heat in a determined area of the house. A certain loss of heat is to be expected more the duct length increase. 3

4 Forced Air Kit

FORCED AIR KIT INSTALLATION (AC01363) 1 Warm air outlet can be connected on the left side (1) or on the back (2) of the unit. Remove the knock-out on the selected side. 2 If the metal tabs did not come out with the knock-out, cut or file the remaining tabs on the perimeter of the opening. 5

3 Cut out the insulation to the size of the opening. 4 Cut a notch on the perimeter of the adaptor as shown. 6

5 Align the adapter notch with the fireplace warm air outlet notch and turn until the flange is fully inserted. The adapter is well in place when its flange is completely inserted and the adapter can rotate freely. 6 Install the heat distribution blower in a location where, you will have access for maintenance and somewhere the fan s noise will not be disturbing. 7

*Note: The heat distribution blower must be positioned at a minimum distance of 3 feet from the fireplace and outside of its enclosure. *Note: The length of the insulated flexible pipe between the fan and the air outlet must be no less than 12 feet. *Note: A minimum clearance to combustible materials of 2 inches from the heat distribution blower is required. *Note: The heat distribution blower can be installed horizontally, vertically or at any angle. 7 Connect the insulated flexible aluminized trilaminated pipe (B) to the fireplace adapter (E), then to the inlet of the heat distribution blower (A) using two clamp collars (C). Use the same procedure to secure the insulated flexible pipe to outlet of the heat distribution blower (A) and to the air register (D). Although it is not mandatory, it is recommended to use insulated flexible pipe for the entire length in order to circulate air at a sufficient temperature through the system. To obtain optimal efficiency, a maximum run of 50 feet is recommended. 8

HOT AIR GRAVITY KIT - MODERN STYLE (AC01385) INSTALLATION CAUTION: THE HOT AIR GRAVITY KIT (AC01385) IS MANDATORY AND MUST BE COMBINED TO THE PRESENT FORCED AIR KIT (AC01363). For the forced air kit to function properly it must be installed to a thermal switch. To do so, follow the following steps. 1 Remove the 4 screws (A) (set a side) that hold the access panel (B) of the box. Pass a cable (C) 14/2 (14 AWG) through the hot air gravity box 9

2 Pass the same previously mentioned cable through the cable connector (D) of the thermal switch box. Strip the cable end (E) and connect 2 terminals (1/4 not supplied) (F). 3 Connect the terminals (F) to the thermal switch (H) already preassembled to its mounting plate (G). 10

4 Tighten the cable connector and attach the box with the help of the 4 nuts (I) provided. 5 Mount the thermal switch box (G) into the hot air gravity box using the previous 4 screws (A). It is strongly recommended to use the rheostat to allow turning OFF the heat distribution blower manually before you open the fireplace doors. If the blower is running, the smoke could be drawn out of the fireplace instead of up the chimney and sparks may be drawn into the insulated flexible pipe of the forced air kit. Note that this rheostat will not turn the heat distribution blower ON unless the fireplace is hot enough (See Figure 1). 11

12 Figure 1