Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

Similar documents
MERLIN RANGE GAS DETECTION EQUIPMENT

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Gas interlock system S & 100 CS

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Troubleshooting Guide

Troubleshooting Guide

GPPS-evo V3.3. Installation Instructions

VGPS-evo V3.3. Installation Instructions. The VGPS-evo is a gas pressure proving system with ventilation interlock and optional CO2 detection.

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock.

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

ACCU-TEST SAFETY. Assured Gas Shut Off Protection

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

Please read this sheet as it contains important information

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

BX444-Mc Gas Detector

MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

GS100M Gas Detector. Technical Specification

Installation Instructions

TECHNICAL INSTRUCTIONS

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

intelligent solutions

BX444-M Gas Detector. Features. Application. Operation

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER

Building Services Brochure

Multi Function Control System for Boiler and Plant rooms SEC-B. The Home of Control & Automation in Ireland

Zareba Metro Gas Detector

Control Panels and Fire Detection Equipment

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

P R O D U C T D ATA S H E E T

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

GL-CO-RFG Channel Gas Leak Alarm System

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

GS100M Gas Detection Controller

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

GS300M Gas Detector. Features. Application. Operation

GS100M Gas Detector. Features. Application. Operation

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

MINERVA MX. 800 Series Ancillary Equipment

P R O D U C T D ATA S H E E T

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Application, Installation, Operation & Maintenance Manual

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

ALTAIR 5X Multigas Detector Product Specification

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

An introduction to... Sigma

APPLICATION DATA SHEET

TECHNICAL INSTRUCTIONS

Intelligent addressable fire alarm control panel

IGD.CO.UK

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Intelligent Addressable Fire Alarm System

Flopurge TS. Operation Manual

CHAPTER 20 SERVICE EQUIPMENT

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Addressable and Conventional Fire Protection

CODESEC FIRE ALARM SYSTEMS. security technologies

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Fire and Smoke Control Systems

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

FEC403EN Installation Manual

Gas ventilation monitoring and control system

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

Installation and user manual for the BiWire / Conventional Repeater Panel

P R O D U C T D ATA S H E E T

Control Panel Engineering and Commissioning Instructions

Largo & Allegro. Rotary Screw Compressors LARGO & ALLEGRO 23-36

Zareba Sensepoint Pro

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Accuracy by Design Products for the HVAC Professional

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Accessible Toilet Alarm

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

The complete conventional fire warning system

Smoke Vent Control Panel PCB4 V4 Installation Manual

INSTALLATION AND OPERATING INSTRUCTIONS

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

EXTINGUISHING AGENT RELEASE MODULE

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

AT-G-SENSE Gas Sensing System

For more information, please visit 3-form.com or call

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

Transcription:

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

2 THE MERLIN RANGE AMERICAN GAS SAFETY Gas detection and controls for boiler house applications American Gas Safety is becoming North America s leading designer, manufacturer & supplier of the latest range of gas detection and gas pressure proving systems. THE MERLIN RANGE We also design, manufacture and supply a full range of gas safety systems for use in laboratories and commercial kitchens. American Gas Safety has 30 years of experience in the gas industry and has become the trusted name to provide gas safety and installation solutions to the commercial market.

AMERICANGASSAFETY.COM 3 Meeting Gas Safety Standards is our business and our passion Our fully qualified engineers and designers keep up to date with industry practices and developments, adhering to all health and safety legislation, as well as, building codes. Our customers can feel assured that the solutions we are providing along with the technical backup are second to none. American Gas Safety is a family run and operated business with excellent customer service and value for money at its core. ADVANTAGES OF WORKING WITH AMERICAN GAS SAFETY Full technical support available Competitively priced Complete after sales care Full product catalogue available at americangassafety.com Easy Installation Express delivery available nationwide Modern digital design Full product operating and maintenance available online

4 THE MERLIN RANGE CONTENTS Find the panel you need in an instant GDP2 2 zone gas detection panel. See pages 6&7 GDP4 Multi zone gas detection panel. See pages 8&9 500S Single zone utility control. See pages 10&11 500S+ Two zone utility control. See pages 10&11 FAB1 Fire alarm bypass. See pages 12 DETECTOR Gas detector. See pages 6&7 ANCILLARY Supplementary products. See pages 14

AMERICANGASSAFETY.COM 5

6 THE MERLIN RANGE THE MERLIN RANGE GDP2 System The Merlin GDP2 can be used as a single or two zone gas detection and shut off system. Used in a variety of applications including boiler-houses, plant- rooms and factories. The Merlin GDP2 can operate with up to two Merlin detectors to monitor a variety of gases, the more common being Natural gas (Methane), Carbon Monoxide and LPG. Gas detectors are fixed remote from the GDP2 panel & should be wired back to the GDP2 panel with three core low voltage cable. Remote emergency shut- off buttons and thermal links can also be connected to the Merlin GDP2 panel. ADVANTAGES OF THE MERLIN GDP2 SYSTEM Easy to install The use of clearly marked PCB connections, low voltage wiring and push-fit wiring connections makes the GDP2 very simple to install. User friendly Digital LED design gives clear system indication at all times. Easily Adaptive Will work with building management systems and remote fire panels. Fitted with emergency stop as standard capable of accepting any number of additional emergency shut off buttons. Covered by the American Gas Safety 3 year warranty. Detector Dimensions: H 3.7 inch x W 5.2 inch x D 1.3 inch

AMERICANGASSAFETY.COM 7 WIRING DIAGRAMS AND ANCILLARY PRODUCTS 10 1 2 3 4 5 6 7 8 9 11 BOX DIMENSIONS: H 4.4 INCH X W 6.4 INCH X D 2.4 INCH (EXCLUDING EM STOP) 1. Mains Input 100-120VAC 2. Gas Solenoid Valve Power Output,100-120VAC Max 3A 3. Remote Gas detector input, 24VDC power supply (sold separately) 4. Remote Gas detector input, 24VDC power supply (sold separately) 5. Remote EM Stop buttons (purchased separately). VOLT FREE INPUT 6. Fusible Links (purchased separately). VOLT FREE INPUT 7. Fire panel (Supplied by others). VOLT FREE INPUT 8. BMS output contacts. Normally Closed, Common & Normally Open 9. Sounder Alarm, 24VDC power supply (purchased separately) 10. BMS selection & Auto reset 11. Zone 1 & 2 enable/disable dip switches MERLIN GDP2 SYSTEM WIRING DIAGRAM

8 THE MERLIN RANGE THE MERLIN RANGE GDP4 System The Merlin GDP4 is a gas detection and shut off system that can be used with up to twelve Merlin gas detectors, Used in a variety of applications including boiler-houses, plant-rooms and factories. The Merlin GDP4 can operate with Merlin gas detectors to monitor a variety of gases, the more common being Natural gas (Methane), Carbon Monoxide and LPG. Gas detectors are fixed remote from the GDP4 panel and are wired back to the GDP4 panel with three core low voltage cable. The GDP4 can be used to monitor the same or a number of different gases. Remote emergency shut- off buttons and thermal links can also be connected to the Merlin GDP4 panel. GDP Detector Dims: H 3.7 inch x W 5.2 inch x D 1.3 inch ADVANTAGES OF THE MERLIN GDP4 SYSTEM Easy to install The use of clearly marked PCB connections, low voltage wiring and push-fit wiring connections makes the GDP4 very simple to install. Multi zone system - Can be used with up to twelve gas detectors. User friendly Digital LED design gives clear system indication at all times. Easily Adaptive - Will work with building management systems and remote fire panels. Fitted with emergency stop as standard capable of accepting any number of additional emergency shut off buttons. Covered by the American Gas Safety 3 year warranty.

AMERICANGASSAFETY.COM 9 WIRING DIAGRAMS AND ANCILLARY PRODUCTS 1 2 3 4 5 6 7 8 9 10 11 BOX DIMENSIONS: H 7.1 INCH X W 10 INCH X D 2.5 INCH (EXCLUDING EM STOP) 1. Mains Input 100-120VAC 2. Gas Solenoid Valve Power Output, 100-120VAC Max 3A 3. Remote Gas Detector Input, 24VDC Power Supply (purchased separately) 4. Remote Gas Detector Input, 24VDC Power Supply (purchased separately) 5. Remote Gas Detector Input, 24VDC Power Supply (purchased separately) 6. Remote Gas Detector Input, 24VDC Power Supply (purchased separately) 7. Remote EM Stop Buttons (purchased separately). VOLT FREE INPUT 8. Fusible Links (purchased separately) 9. Fire Panel (Supplied by others). VOLT FREE INPUT 10. BMS Output Contacts. Normally Closed, Common & Normally Open. 11. Sounder Alarm 24VDC Power Supply (purchased separately). MERLIN GDP4 SYSTEM WIRING DIAGRAM

10 THE MERLIN RANGE THE MERLIN RANGE 500S System 500S+ System The Merlin 500S panel is designed to provide the user with an effective means of isolating any utility, via a key switch or in the event of an emergency, by operation of the emergency EPO button. The key operated 500S product carries a 3 year AGS warranty and is fully supported by our technical team. The 500S has a fascia mounted emergency shut off button fitted as standard and the fascia mounted LEDs give simple and concise information to the operator. The panel is fully compatible with AGS remote emergency stop terminals allowing a large number of EPO terminals to be connected in series and wired back to the panel. The 500S can be integrated with a BMS and fire alarm via a low voltage dry contact. The 500S in an excellent isolation panel. Simple to fit with little maintenance required and is covered by the full support that comes with the entire range of Merlin products The Merlin 500S+ is a two zone isolation panel with two outputs: Utility 1 & Utility 2. The 500S+ is designed to provide an effective way of isolating gas, water, electricity, oil, compressed air etc. by means of a key switch on the panel or by the operation of the emergency shut off button. The key operated 500S+ product series carries a 3 year AGS warranty and is fully supported by our technical team. The 500S+ has a fascia mounted emergency shut off button fitted as standard and the fascia mounted LEDs give simple and concise information to the operator. The panel is fully compatible with AGS remote emergency stop terminals allowing a large number of EPO terminals to be connected in series and wired back to the panel. The 500S+ can be integrated with a BMS and fire alarm via a low voltage dry contact. The 500S+ in an excellent dual isolation panel. Simple to fit with little maintenance required and is covered by the full support that comes with the entire range of Merlin products.

AMERICANGASSAFETY.COM 11 WIRING DIAGRAMS AND ANCILLARY PRODUCTS 1. Mains Input 100-120VAC 3 4 5 6 2. Utility Power Output, 100-120VAC Max 3A 3. BMS Selection & Auto Reset Dip Switch 4. Remote EM Stop Buttons (purchased separately). VOLT FREE INPUT 2 1 5. Fusible Links (purchased separately) 6. BMS Output Contacts. Normally Closed, Common & Normally Open BOX DIMENSIONS: H 4.4 INCH X W 6.4 INCH X D 2.4 INCH (EXCLUDING EM STOP) MERLIN 500S SYSTEM WIRING DIAGRAM 1. Mains Input 100-120VAC 4 5 6 7 2. Utility Power Output, 100-120VAC Max 3A 3. Utility Power Output, 100-120VAC Max 3A 4. BMS Selection & Auto Reset Dip Switch 5. Remote EM Stop Buttons (purchased separately). VOLT FREE INPUT 2 3 1 6. Fusible Links (purchased separately) 7. BMS Output Contacts. Normally Closed, Common & Normally Open. BOX DIMENSIONS: H 4.4 INCH X W 6.4 INCH X D 2.4 INCH (EXCLUDING EM STOP) MERLIN 500S+ SYSTEM WIRING DIAGRAM

12 THE MERLIN RANGE THE MERLIN RANGE FAB1 System The Merlin FAB 1 (Fire Alarm Bypass) system gives the user the ability to have use of the gas for a pre-set time whilst the fire alarm is being tested. Without a FAB-1 the Gas could be shutoff via the buildings BMS system during a fire alarm test. With prior notice to a fire alarm test, the user can turn the key on the FAB1 to the on position, giving an uninterrupted gas supply for between 10 and 45 minutes. During this time the system controlling the gas will ignore shut-off signals from the buildings fire alarm system. The bypass time can be adjusted using the dip switches inside the panel. During the bypass time gas can still be shut off, pressing the emergency gas shut off button will close the gas solenoid valve.

AMERICANGASSAFETY.COM 13 WIRING DIAGRAMS AND ANCILLARY PRODUCTS 5 4 3 2 1 BOX DIMENSIONS: H 4.4 INCH X W 6.4 INCH X D 2.4 INCH (EXCLUDING EM STOP) 1. Mains Input 100-120VAC 2. Fire alarm input 3. Connect to fire panel terminal in the merlin panel 4. BMS input 5. Switches for bypass time adjustments MERLIN FAB1 SYSTEM WIRING DIAGRAM

14 THE MERLIN RANGE THE MERLIN RANGE Ancillary Equipment American Gas Safety provide a comprehensive package, supplying not only gas detection and interlock panels but also a full range of ancillary equipment. Gas Solenoid Valve We only supply the best quality Gas Solenoid Valves which are design for safety and the control of various gases, including Natural gas, Propane and LPG. They are safety shut off valves Normally closed, so when power is supplied to the gas solenoid valve it will automatically open and as soon as that power is taken away the gas solenoid valve will close. The valves supplied are all covered by the American Gas Safety 3 year warranty and are tested and certified to UL standards. The valves are also rated to IP65 thus allowing them to be deployed in wet or dirty environments. Merlin Gas Detector Range American Gas Safety supplies a full range of remote gas detectors for detecting CO, CO2, natural gas and LPG to compliment the Merlin range of panels. The detectors are designed using modern European digital components. If the relative gas is detected on the sensor head this will trigger the isolation of the power supply to the solenoid and isolate the gas supply. This can then be rectified by resolving the leak, allowing the sensor head to clear and resetting the attached Merlin panel. There is no need for on-site calibration or re-calibration saving time and money. Emergency Knock-Off Button We only supply the highest quality emergency knock-off buttons for increased longevity and reliability. The Emergency Knock-off button s can either be twist release type, twist key release type or use a resettable Perspex screen, whichever the governing code stipulates. Once the EM stop button has been depressed the Merlin panel will not function until the system has been reset both at the button and on the unit. There is no limit to the number of additional EM stops that can be fitted per Merlin panel and they are connected with low voltage cabling. Heat detectors All panels in the Merlin range will accept the connection of heat detectors (Fusible Links). It is recommended that heat detectors should be positioned over the heat source, whether it be a boiler or water heater. The heat detector will trigger the alarm state at temperature of 72 degrees centigrade.

AMERICANGASSAFETY.COM RESET TEST AMERICANGASSAFETY.COM AMERICANGASSAFETY.COM AMERICANGASSAFETY.COM 15 THE MERLIN RANGE A typical boiler room set up METHANE SENSOR 12INCH FROM CEILING GAS DETECTION SYSTEM MERLIN GDP2 Power Methane Power Zone 1 EMERGENCY SHUT OFF CO Gas On Zone 2 EM Stop Heat Detector SOUNDER STROBE Fire Alarm RESET MUTE HEAT SENSORS Power CO Detector FIRE ALARM BMS Low High CARBON MONOXIDE SENSOR 60INCH FROM FLOOR BOILER 1 BOILER 2 GAS VALVE The above diagram is an example of a Merlin GDP2 Gas Detection System

AGS HEAD OFFICE +1 (727) 608 4375 FAX: +1 (727) 538 4237 EMAIL: INFO@AMERICANGASSAFETY.COM 4500 140TH AVENUE NORTH SUITE 101, CLEARWATER FL 33762 WWW.AMERICANGASSAFETY.COM