FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Similar documents
Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

Global Series Screw Air Compressors Life source of industries

FLOW HEATER 32E X 2R IMPORTANT GENERAL INFORMATION: SPECIFICATION. Instruction Manual. Article number: 045a-105 Electric heating capacity:

Global Series Screw Air Compressors Life source of industries HP

Refrigeration dryers DW 2-504

Compressed Air Products

New standard in compressed air treatment, providing Energy Savings up to 99%

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

EG Series Screw Air Compressors Life source of industries kw

Refrigeration air dryer

EG Series Screw Air Compressors Life source of industries HP

OIL FREE COMPRESSED AIR Piston, Scroll & Screw Compressors 55 L/min to 42,763 L/min 2 Cfm to 1510 Cfm

DENTAL AIR. LFx LF SF Class 0 clean air compressors. Atlas Copco dental compressors - 1

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

INDUSTRIALS GROUP. Refrigerant Dryers. Innovative Compressed Air Treatment Solutions GDD Series

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

QUINCY QOF SERIES OIL-FREE AIR COMPRESSORS QOF 2-30 HP

COMPRESSED AIR TREATMENT

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

Oil-Free Compressors. Oil-Free Compressors. Quincy QOF Series Oil-Free Air Compressors QOF 2-30 HP

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance.

ROTARY SCREW COMPRESSOR CSA 5,5-7, HP

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

Refrigeration dryers DW 2-504

Rotary type Oil-free Air Compressor General Catalogue. Oil-free Scroll Air Compressor Oil-free Claw Air Compressor

100% Oil-Free - Guaranteed

Oil Mist Separator Unit LGA 600 FUW

OPERATING INSTRUCTIONS

Refrigeration dryers for energy efficient compressed air quality

Adsorption Dryers. AD 7 to 1300

The Highest Quality Compressed air treatment Refrigerant dryers CFM 0.33 to 91.1 M/min

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL

CPP condensate separator series. High-performance products. Designed for you!

OIL-FREE SCREW AIR COMPRESSORS PRODUCT CATALOG

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Practic - HLE. Piston Compressors 2 TO 10 HP 6 TO 500 LITRES

ROLLAIR AIR COMPRESSORS

Rotary screw compressors. kw 2, ,5 bar 10 BRIO

Oil-injected rotary screw compressors GA GA

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

DRYPOINT AC ADSORPTION DRYERS EFFICIENT, COMPACT, POWERFUL m 3 /h

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

Refrigerant Dryers DS Series

Oil Free Scroll Compressors

ECO SCROLL OIL-FREE AIR COMPRESSOR KW

Vacuum Pump Vacuum Pump

DRYPOInt RA. Drying. The concept determines the efficiency. DRYPOINT RA, the most economic way to dry compressed air

White paper Compressed air drying

Rotary screw compressors

Membrane Dryers KMM Series

F o r Te x t i l e I n d u s t r y

Rotary screw compressors

Membrane Dryers KMM Series

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

With the world-renowned SIGMA PROFILE

Refrigerated Air Dryers

UltraDry s Features and Benefits

Refrigeration Dryers TG TI Series

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

WIND Technical Description

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

Refrigerated Compressed Air Dryer

Refrigerated Air Dryers

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

REFRIGERATION AIR DRYERSDW DW 2-420

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

The Technology of Modern Filtration KRAD. Compressed Air Dryer with integrated compressed air filters

Refrigerated Air Dryers

TUBULAR SERIES. IWATA STUDIO SERIES TUBULAR SERIES AIR COMPRESSORS IS-875HT and IS-925HT

meets medilab Oil-free compressed air for the medical and laboratory market

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

Treatment. Compressed Air. Equipment CONTENTS

Chapter 9: The basics of air preparation

HYDROGARD Refrigerated Air Dryers HGD and DES Series

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Oil Mist Separator Unit LGA 600 FUW

ADSORPTION DRYING: WHY?

DGH Series Global Air Treatment

KONDRAIN KONDRAIN HP. Condensate Drains. Intelligent condensate drainage up to 350 bar. Rev 03_ EN

Adsorption Air Dryers

Rotary Screw Compressors SXC»Compact«Series

RN SERIES REFRIGERATED COMPRESSED AIR DRYERS NON-CYCLING REFRIGERATEDERATED COMPRESSED AIR DRYERS SCFM

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Reciprocating Compressors AIRBOX / AIRBOX CENTER

REFRIGERATED AIR DRYERS

LMF Rotary Screw Air Compressors kW LX Range

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Largo & Allegro. Rotary Screw Compressors LARGO & ALLEGRO 23-36

REFRIGERATED AIR DRYERS SCFM. CRPC Energy Saving Series

Allegro. Rotary Screw Compressors. Allegro 8-14

50 barg refrigeration dryers PoleStar Smart HP

Rotary Screw Compressors SXC»Compact«Series

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Ingersoll Rand. Refrigerated Air Dryers. mb air systems ltd

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770

Transcription:

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

The Most Advanced Technologies for High-Quality air High-precision processing technology is required to produce the components that make up a Scroll Compressor. We have developed new Scroll Air-Ends thanks to the experience and know-how we have accumulated over the past 0 years. Class Zero Certification TÜV (independent third party test house) has just certified that the air quality from our oil free scroll compressors is in conformity with Class 0 (ISO857-:00[-:-:0]). Scroll Compression Principle As the orbiting scroll goes from No. to No.4 position, the size of the symmetrical crescent-shaped compression chambers is gradually reduced, compressing the air contained within. This is then discharged through the central exhaust port. 4 Orbiting scroll Fixed scroll Compression chamber Clean Air from oil-lubricated compressors contains oil and can contaminate the piping. This does not happen with an Oil-Free Scroll Compressor which produces high-quality oil-free air. INSIDE THE PIPING OF AN OIL-LUBRICATED COMPRESSOR What is Class Zero? ISO857-(JIS B89-) defines quality classes for compressed air. Class Zero indicates wall flow oil, oil mist and oil vapor are completely absent. As oil vapor in particular cannot be absorbed by conventional air filters, it is important factories that require clean air use Class Zero compressors. Oil-Free Drain Drainage from oil-lubricated compressors requires proper treatment as it contains oil. Oil-free scroll compressors, on the other hand, are eco-friendly, their drain is clean and does not contain oil, therefore avoiding the cost of drain disposal. INSIDE THE PIPING OF AN OIL-FREE COMPRESSOR CLASS 0 Oil Concentration mg/m³ As specified by the equipment user or supplier and more stringent the Class Drainage from an oil-free compressor Drainage from an oil-lubricated compressor 0.0 0. 4 5 Wall Flow Oil Oil Vapor Oil Mist

8.000 HOURS MAINTENANCE-FREE except intake filter 0.75 kw (HP) Oil Free Scroll Compressors are constantly evolving ANEST IWATA was the first manufacturer to introduce Oil Free Scroll Compressors in 99 and has kept improving them ever since in order to provide customers with the most advanced technology for high-quality air. Features 8.000 hrs. maintenance free * Class Zero oil-free air Low noise level Low vibration Compact size Wheels for easy relocation Membrane dryer model available 49dB(A) Principle of membrane Features of Membrane Dryer Environmentally friendly; no Freon gas SLPE-07E Purge-cut function Evolutional History of Scroll Compressor Casters for better mobility Scroll air-end (HP) (Direct-Driven) Aluminium air receiver (anti-rust coated) Membrane dryer Dryer Level (*) Outlet Dimensions capacity Weight dew point (wxdxh) kw HP bar MPa psi L/min m /h CFM db(a) size C L mm kg Volt/Hz/Pha SLPE-07E 70 4..4-5x590x690 50 Rc /8 5 0.75 49 switch [ball valve] (internal) SLPE-07ED 60.6. 5 5x660x690 5 99 000 004 006 * is measured at max working. * Noise level measured at a distance of M according to ISO0; tolerance±db * Except intake filter Even with Class Zero compressors, oil may be found in the piping. This may be caused by the presence of oil in the piping before installation of the compressor or by accident during the production process

0.000 HOURS MAINTENANCE-FREE except intake filter 5.000 hours for 0 bar 0.000 HOURS MAINTENANCE-FREE except intake filter 5.000 hours for 0 bar Features 0.000 hrs. maintenance free * Class Zero oil-free air IE premium efficiency motor panel for easy operation in 5.5/7.5kW model Low noise level Low vibration.5 kw (HP) - 7.5 kw (0HP) kw (5HP) - 5 kw (0HP) Emergency Stop button Hour meter Motor gauge Scroll air-end Features Multi Stage for energy conservation Class Zero oil-free air 0.000 hrs. maintenance free for 8 bar model * IE premium efficiency motor Touch panel for monitoring running conditions Low noise level Low vibration Multi-stage Scroll Compressor SLPE-5()E-7()E SLPE-55()F-75()F Oil-Free Delivered air does not contain Fixed scroll Orbiting scroll any oil and is suitable for all applications where oil-free air is essential. 8 bar models Cooling fan Tip seal 7.5kW Scroll Air end (new) Noise kw HP bar MPa PSI L/min m /h CFM db(a) size mm kg Volt/Hz/Pha SLPE-5E.5 55 9. 5.5 57 SLPE-E-M. 4 4.5 8.5 Rc /8 55x686x74 87 SLPE-E-T. switch 4 4.5 8.5 6 [ball valve] SLPE-7E.7 5 404 4. 4. 0 SLPE-55F 5.5 7.5 596 5.7.0 6 Rc /4 05 SLPE-75F 7.5 0 sensor 808 48.4 8.5 65 [ball valve] 0 0 bar models Noise kw HP bar MPa PSI L/min m /h CFM db(a) size mm kg Volt/Hz/Pha SLPE-5E.5 9 9. 5.5 57 SLPE-E-M. 07 4.5 8.5 Rc /8 55x686x74 87 SLPE-E-T. switch 07 4.5 8.5 6 [ball valve] SLPE-7E.7 5 0.0 45 7 4. 4. 0 SLPE-55F 5.5 7.5 Rc /4 SLPE-75F sensor [ball valve] 7.5 0 * is measured at max working. * Noise level measured at a distance of M according to ISO0; tolerance±db *- Except intake filter *- 5000 hrs. for 0 bar models and 8000 hrs. for 5.5kW and 7.5kW models Even with Class zero compressors, oil may be found in the piping. This may be caused by the presence of oil in the piping before installation of the compressor or by accident during the production process 8 bar models 0 bar models kw HP bar MPa PSI L/min m /h CFM db(a) size mm kg Volt/Hz/Pha SLPE-0E (x.7) 5 7.6 4.7 6 Rc 65x958x556 SLPE-50E 5(4x.7) 0 sensor 65 96.8 57.0 6 [ball valve] 4 kw HP bar MPa PSI L/min m /h CFM db(a) size mm kg Volt/Hz/Pha SLPE-0E (x.7) 5 009 60.5 5.6 6 Rc 0.0 45 65x958x556 SLPE-50E 5(4x.7) 0 sensor 46 80.7 47.5 6 [ball valve] 4 * is measured at max working. * Noise level measured at a distance of M according to ISO0; tolerance±db *- Except intake filter *- 5000 hrs. for 0 bar models Even with Class zero compressors, oil may be found in the piping. This may be caused by the presence of oil in the piping before installation of the compressor or by accident during the production process

LIST OF TECHNICAL SPECIFICATIONS 8 bar models Dryer Level (*) Outlet dew point capacity Dimensions kw HP bar MPa PSI L/min m /h CFM db(a) size C L mm kg Volt/Hz/Pha SLPE-07E 0.75 70 4..4-5 (internal) 5x590x690 50 49 SLPE-07ED 0.75 60.6. 5-5x660x690 5 SLPE-5E.5 55 9. 5.5 57 Rc /8 - - switch SLPE-E-M. 4 4.5 8.5 [ball valve] - - 87 55x686x74 SLPE-E-T. 4 4.5 8.5 6 - - - SLPE-7E.7 5 404 4. 4. - - 0 SLPE-55F 5.5 7.5 596 5.7.0 6 Rc /4 - - 05 SLPE-75F 7.5 0 808 48.4 8.5 65 [ball valve] - - 0 SLPE-0E (x.7) 5 sensor 7.6 4.7 6 Rc - - 65x958x556 SLPE-50E 5 (4x.7) 0 65 96.8 57.0 6 [ball valve] - - 4 Air Compressor Accessories Refrigerated Air Dryer Use of Refrigerated Air Dryers allows for the best performance of our oil-free scroll compressors. These units incorporate an electronic control to monitor all functions. A hot gas bypass valve avoids the formation of ice in the dryer. The vertical flow layout allows for easy access to the drain valve. 0 bar models Dryer Level (*) Outlet dew point capacity Dimensions kw HP bar MPa PSI L/min m /h CFM db(a) size C L mm kg Volt/Hz/Pha SLPE-5E.5 9 7. 4. 57 - - SLPE-E-M. 07.4 7. Rc /8 - - 55x686x74 87 SLPE-E-T. switch 07.4 7. 6 [ball valve] - - SLPE-7E.7 5 7 0..9 - - 0 SLPE-55F 0.0 45 5.5 7.5 coming soon - - coming Rc /4 soon SLPE-75F [ball valve] 7.5 0 coming soon - - coming soon sensor SLPE-0E (x.7) 5 7.6 4.7 6 Rc - - 65x958x556 SLPE-50E 5 (4x.7) 0 65 96.8 57.0 6 [ball valve] - - 4 * is measured at max working. * Noise level measured at a distance of M according to ISO0; tolerance±db. Even with Class zero compressors, oil may be found in the piping. This may be caused by the presence of oil in the piping before installation of the compressor or by accident during the production process. AID-6 / AC AID- / AC 4 5 6 * 7 SLPE - E D - M - 70 SLPE Oil Free Scroll Compressor Max. Press. 4 Series 5 Dryer 6 * 7 * : Only,kW model 07 0,75kW / HP 5,5kW / HP,kW / HP 7,7kW / 5HP 55 5,5kW / 7,5HP 75 7,5kW / 0HP 0 kw / 5HP 50 5kW / 0HP 0 kw / 0HP 00 0kW / 40HP Blank 8 bar 0 bar E F Blank D M T Blank E Series F Series Without Dryer With Dryer Single phase, 0V/50Hz Three phase, 400V/50Hz Without tank 90 With 90L tank 70 With 70L tank 500 With 500L tank name Part no. Compressor combination Max. air flow Outlet Dimension (wxdxh) Weight kw (HP) L/min size mm kg Volt/Hz/Phase AID-/AC AID00GPJ000 (4) 50 G/8 0x45x45 AID-6/AC AID006GPJ000 4(5.5) 600 5 AID-9/AC AID009GPJ000 5.5 (7.5) 950 6 G/ 70x55x475 AID-/AC AID0GPJ000 7.5(0).00 8 AID-8/AC AID08GPJ000 (5).800 AID-5/AC AID05GPJ000 5 (0).500 G 45x40x740 4 AID-/AC AID0GPJ000 8.5 (5).00 9 45x445x740 AID-4/AC AID04GPJ00 (0) 4.00 G-/4 40 AID-5/AC AID05GPJ00 + (0+) 5.00 485x455x5 49 AID-6/AC AID06GPJ004 0 (40) 6.00 54 G-/ 555x580x885 AID-75/AC AID075GPJ004 7 (50) 7.500 56 AID-05/AC AID05GPJ004 55 (75) 0.500 94 G 555x65x975 AID-0/AC AID0APJ004 55+(75+).000 96 AID-68/AC AID68APJ00 90 (0) 6.800 G-/ 665x75x05 44 0/50/single 0/60/single 0/50/single Data refers to the following nominal conditions: ambient temperature of 5 C, with inlet air 7 bar and 5 C, and 5 C dew point(-0.5 C atmospheric dew point). Max. working conditions: ambient temperature 45 C, inlet air temperature 55 C and inlet air 4 bar (6 bar for AID- to AID-8). It is recommended to install an air filter before the inlet.

How to Install Air Compressors INSTALLATION EXAMPLE FOR OIL FREE COMPRESSORS TO OPTIMIZE THE SUPPLY OF COMPRESSED AIR 4 Air Compressor Accessories 5 8 6 7 Air Receiver (Vertical) name N87FY000 Max. working Capacity Connection Weight Dimension MPa (bar) Liter in-out kg wxdxh (mm) 00 G/8-/4 7 70x70x56 N87LY000 00 6 446x446x554.() N87NY000 70 G/8-80 500x500x648 N87TY000 500 5 600x600x050 *equipped with safety valve, gauge, air release valve and drain valve 4 AIR COMPRESSOR: Oil Free Compressors are always recommended not only to provide clean air but also to reduce the maintenance time and costs. AIR RECEIVER TANK: The receiver tank acts as a reservoir of compressed air for peak demands and also helps remove water from the system by allowing the air a chance to cool and also. CONDENSATE DRAINAGE: Unnecessary costs and damage during the generation of compressed air can only be avoided in an efficient way with amount-adjusted condensate drainage. Condensate drains operate with a capacitive sensor which prevent compressed-air losses and minimize the energy demand. PRE-FILTER: To capture large particles that cannot be captured by the main filter. In other words, the pre-filter will prevent the debris from getting into the main filter and so this brings addition strength to the filtering technology used in air purifiers. Air Filter with Auto Drain name F4000-0G-WFZ Auto Drain name Max. working *recommended electric cable is X 0.75mm Connection Electricity Weight Dimension MPa (bar) in-out outlet (hose size) kg wxdxh (mm) BEKOMAT.6(6) G/ G½(φ8-0) 0V/50-60HZ.0 79x74x5 Air Regulator name max. working *equipped with gauge Max. working F4000-0G-WFY.0(0) 0.μ Filtrating Connection Weight Dimension MPa (bar) μm in-out kg wxdxh (mm) 5μ M4000-0G-W-FM 0.0μ *also available with other connection sizes from /8 to inch Setting range G/8* 0.45 80x79x7 Connection Weight Dimension MPa (bar) MPa (bar) in-out kg wxdxh (mm) R6000-0G-W.0MPa (bar) 0.05 to 0.85 (0.5-8.5) G/4 90x90x5 5 6 7 8 BYPASS LINE: Bypass lines are recommended in the event of maintenance of the air dryer and/or malfunctions so that main pipe line can be switched easily. MICRON FILTER: To eliminate more smaller size of vapor and solid particles than prefilter. ACTIVATED CARBON FILTER: To remove odors and vapors. They are used in factories where food is produced or for dental and medical who requires clean air. REFRIGERATED AIR DRYER: A refrigerated compressed air dryer is a type of compressed air dryer, used to dry compressed air. Compressed air always contains water, coming from the air that is sucked in by the compressor. To protect your piping, tools and equipment, it is always recommended to install. Safety precautions Compressor usage. Read the instruction manual before using the compressor.. These compressors are designed for air compression only and must never be used for any other type of gas.. Never use with respiratory equipment which directly intakes compressed air. This may cause serious injury. 4. Never direct the jet of air towards yourself, other persons or animals. 5. When using compressed air, be aware of and comply with all safety precautions to be adopted for the single application (inflating, using pneumatic tools, painting, washing, etc.). Compressor Installation. The compressor must never be exposed to adverse weather conditions (rain, sun, snow, etc.).. Keep the compressor away from explosive and flammable (acetylene or propane, etc.) objects to prevent fire and explosion.. Make sure ambient temperature at the compressor s chosen place of installation is always within the limits indicated in the instruction manual. Maintenance. Perform maintenance on the compressor routinely as indicated in the instruction manual.. Drain the water in the receiver tank every day to prevent clogging of the drain cock.. Never clean the compressor with liquids or solvents. When cleaning, disconnect the compressor from the electricity supply by removing the plug and use a damp cloth only. Others. Never alter or convert the compressor or its parts. Doing so may cause fire or malfunction.. Prepare a back-up compressor or other back-up system in case the compressor stops due to malfunction or activation of its protective devices. *Safety precautions of the above are minimum requirements. Before use, follow safety precautions in the instruction manual and each municipality, county and corporation's regulations.

ANEST IWATA GLOBAL NETWORK AI Poland AI Germany AI Sweden AI Russia AI China AI South Korea AI U.S. AI U.K. AI France AI Spain AI Italy AI CORPORATION Japan (Head Office) AI Taiwan AI Vietnam AI Thailand AI Indonesia AI Brasil AI South Africa AI India AI Myanmar AI U.A.E. AI Australia ANEST IWATA Air Tech s.r.l. Corso Vigevano, 46-055, Torino - Italy Tel.+9 0 09 0 - Fax +9 0 4 75 77 info@anest-iwataairtech.com - www.anest-iwataairtech.com German Office: ANEST IWATA Babatz GmbH Am Stahlbügel 7406 Bad Wimpfen Tel. +49 706-90 - Fax +49 706-99 info@babatz.de - www.babatz.de Swedish Office: ANEST IWATA Scandinavia AB Ögärdesvägen 6 C 4 0 Partille - Sweden Tel +46 40 8 60 info@anest-iwata.se - www.anest-iwata.se Distributed by: