HAMILTON-H900. Intelligent humidification for all patient groups

Similar documents
product overview Adult Care Solutions

PRODUCT OVERVIEW. Adult Care Solutions

NZX Australasian Media Day 12 November 2003

Overview & H1/Q2 FY03 Update Auckland, Wellington, Melbourne, Sydney November 2002

Make the Connection. Compatibility Guide for Noninvasive Systems Validated With INOmax DS IR Plus

Deutsche Bank Securities 27th Annual Health Care Conference

Forward Looking Statements

Coaxial Circuits. Breathing Systems

Dräger VentStar Helix heated (N) plus Consumables and Accessories

Active Humidification

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN)

Quick start guide. English

Quick setup guide. English

Humidification & Filtration

CPAPSolutions. Product Profile. Overview: The Family of SleepStyle TM CPAP Solutions

ACCESSORIES ISLEEP VIVO Z1

Adult and paediatric ventilators. Quick Setup Guide. English

Disconnection Alarm Guide. English

Nuts and Bolts on Humidification: Active or Passive During Pediatric Invasive Mechanical Ventilation?

CLEO VERSATILITY IN VITAL SIGNS

A basic introduction about the principles of humidity

OKM 801INFANT INCUBATOR

VPAP COPD. H5i. Welcome Guide. Making quality of care easy. Respiratory Care Solutions. English NONINVASIVE VENTILATOR HEATED HUMIDIFIER

VPAP ST with ivaps. Welcome Guide. Making quality of care easy. English. Respiratory Care Solutions NONINVASIVE VENTILATOR

Instructions For Use. Hybernite ROC 2300 Rainout Control System

740 SELECT. Multi-Parameter Monitor

System Contents Your REMstar Pro C-Flex+ system includes the following items: Reusable gray foam filter Disposable ultra-fine filter (optional)

Quick start guide. BiPAP AVAPS

WILAmed AIRcon Respiratory Gas Humidifier. Experience High Tech Respiratory Gas Humidification. Made in Germany

Quick start guide. BiPAP AVAPS

OMNI Express VS VERSATILITY IN VITAL SIGNS

Content. TNI Systems. TNI soft Flow 50, TNI soft Flow junior Humidifier Consumables Trolleys and stands Applicators...

CLINICAL MANUAL REF JH 6/7/10 CLINICAL MANUAL

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

D&D Medical Inc EMS products

FISHER & PAYKEL HEALTHCARE CORPORATION LIMITED ANNUAL SHAREHOLDERS MEETING 20 AUGUST 2014 ADDRESS BY TONY CARTER, CHAIRMAN

Bipap A30/40 ventilator and System One humidifier

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

GoodKnight H 2 O. User's Manual. Heated Humidifier. Ref. : M-146DFU00-20 Revision D

Getinge WD15 Claro Washer-disinfector

GE Healthcare. Dash Variable-Acuity Monitoring

User guide User guide English

Puritan Bennett 980 Ventilator System Planning for Training Checklist

Humidification for patients with respiratory failure

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

ila ACTIVVE SYSTEM PLATFORM

Non-invasive/invasive ventilators. User Guide. English

PRODUCT CATALOG HORIZONTAL AUTOCLAVE.

User guide User guide English

VPAP Adapt. H5i. Welcome Guide. English. adaptive servo-ventilator

Ohio Medical s Push-To-Set TM Intermittent and Continuous Vacuum Regulators

A look into our complete product collection.

VPAP Auto VPAP ST VPAP S. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

1 Intended Use of the Breas HA 01 Humidifier

OUR CLIENTS WE CARRY OUT

Suction and Oxygen Therapy Range SUCTION AND OXYGEN THERAPY SOLUTIONS

Humidification in anaesthesia and critical care

GE Healthcare. ivent 201 Catalog

Dräger X-am 7000 Multi-Gas Detection

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

In the 1940s in Chicago, Illinois, a group of oxygentank technicians began meeting with doctors concerned with lung disease. This group named itself

VPAP Adapt. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

Ultraview SL2400 With Wireless-LAN-Option

Operator s Manual Infant Flow SiPAP

H4i. User Guide HEATED HUMIDIFIER. English

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

Professional Design Project

A look into our complete product collection. powered by

OSA Catalog. United States of America

Commission communication in the framework of the implementation of the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices

Quick start guide. CPAP Pro. Auto CPAP. Navigating in the menu. Caring for my. Setting up my therapy. DreamStation. Additional help and tips

5580 S. Nogales Highway Tucson, AZ Phone: (800) Fax: (520) ANAPOD Instructions For Use

Infant Flow SiPAP. Operator s manual

Neonatal Ventilator NV8

A look into our complete product collection.

Ref: TB ENG Issue date: June Plus or INOflo DS

A U T O S E R I E S Operating Manual

EC DECLARATION OF CONFORMITY

Improving Patient Safety and Essential Device Performance International Standards for Home Respiratory Care Equipment

740 SELECT. Multi-Parameter Monitor

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

USER Manual JR 10/02/06

(Information) COMMISSION

LTV Series ventilators

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

Short Instructions TNI 20 oxy

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

AEROpart Oxygen-accessories

TMBU & SCBU CLEANING AND DISINFECTION POLICY

Data Sheet... HANS RUDOLPH, inc. HANS RUDOLPH, inc.

Controlled Environment Equipment Solutions for the Lab

H M H M H M H M H M H M H M B A R R I E R W A S H E R E X T R A C T O R S

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

It only takes an. instant to go DR. DR Retrofit: no limits to retrofitting your X-ray department with DR AED detectors

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

DESIGN ENGINEERING MANUFACTURING

Transcription:

HAMILTON-H900 Intelligent humidification for all patient groups Intelligent Ventilation since 1983

We live for ventilation technology We live for ventilation technology that helps caregivers improve the lives of their critically ill patients. We believe that innovation is essential to meet the demands of critical care. To us, innovation is about realizing visionary new ideas and continuously improving existing products, always keeping patient safety and ease of use in focus. We learn from our customers and from multi-disciplinary experts. And we invest in long-term research and development. We develop Intelligent Ventilation solutions: devices and consumables for the ventilation of all critically ill patients from neonates to adults. Jens Hallek President Bob Hamilton Member of the board HAMILTON-H900

Meet the HAMILTON-H900 The HAMILTON-H900 humidifier has been developed with focus on ease of use and patient safety allowing you to focus on the important aspects of patient care. An innovative two-step setup helps you get started quickly. All connections for the humidifier are contained in a single breathing circuit set, which enables one-handed operation. The HAMILTON-H900 can be used with all common mechanical ventilators and flow drivers. Due to the ergonomic design, the user interface is easily visible and provides all the necessary information at a glance. Integrated temperature probe Wall-heated, all-in-one breathing circuits Adjustable temperature and humidity settings Ventilator-controlled operation* Preassembled and ready for use * Not available in all markets

Less risk of cross contamination By reducing the need to open the circuit to drain condensate, the HAMILTON-H900 minimizes the potential for the spread of pathogens associated with the development of ventilator-associated pneumonia (VAP). 1,2 Automatic connection checks and water-level detection The HAMILTON-H900 automatically checks each tube connection, as well as identifying the water chamber and circuit types. In addition, the humidifier automatically detects high and low water levels, and generates an alarm when it is running low on water. Ensuring the patient is always ventilated with humidification protects the functionality of mucociliary clearance. Reduced cost of ownership Over the lifetime of a humidifier, the initial investments are relatively small. Cost-driving factors include circuits, cables, temperature probes, and time and effort for cleaning and reprocessing. With the HAMILTON-H900, expensive replacements for lost or broken temperature probes and cables are a thing of the past. 1 Alp, Emine, and Andreas Voss. Ventilator Associated Pneumonia and Infection Control. Annals of Clinical Microbiology and Antimicrobials 5 (2006): 7. PMC. 2 Craven DE, Goularte TA, Make BJ. "Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia?" AmRevRespirDis. 1984 Apr; 129(4) 625-628. PMID: 6585160. HAMILTON-H900

Product overview 1 Auto mode key 2 Temperature monitoring window key 3 Tube connection indicators 4 Temperature gradient slider 5 Expiratory temperature increase key 6 Invasive/Noninvasive mode key 7 Chamber exit temperature slider 8 Visual alarm indicator 9 Optical water-level detection 10 Integrated temperature probe 11 All-in-one connector 12 Smooth-bore wall-heated tubes 12 11 2 3 3 4 5 1 7 6 8 9 10

Ventilator-controlled operation* The ventilator connectivity option allows you to operate the humidifier using any compatible Hamilton Medical ventilator. All the controls, monitoring parameters, and alarms are available, and can be set as required from the ventilator. Full integration of humidifier monitoring into patient data management systems is also provided. When used with a compatible ventilator, the humidifier can automatically select the humidification mode (invasive or noninvasive) based on the selected ventilation mode. * Not available in all markets HAMILTON-H900

Various therapies for all patient groups The HAMILTON-H900 is designed to provide humidification and heating of medical gases for adult, pediatric, and neonatal patients with all commonly used respiratory therapies: Invasive ventilation Noninvasive ventilation High flow oxygen therapy ncpap and Bubble CPAP The preassembled breathing circuit sets can be used for up to 28 days and include a temperature probe, water refill tube, Y-piece, and water chamber. Dual limb and single limb sets are available as single-use or autoclavable items. Low compliance and flow resistance Integrated heater wires Detachable, unheated extension for use in incubators Availability of breathing circuit sets on www.hamilton-medical.com/e-catalog

More information: www.hamilton-medical.com/hamilton-h900 Intelligent Ventilation since 1983 Manufacturer: Hamilton Medical AG Via Crusch 8, 7402 Bonaduz, Switzerland +41 (0)58 610 10 20 info@hamilton-medical.com www.hamilton-medical.com 689504.03 Specifications are subject to change without notice. Some features are options. Not all features are available in all markets. For all proprietary trademarks ( ) and third-party trademarks ( ) used by Hamilton Medical AG see www.hamilton-medical.com/trademarks. 2018 Hamilton Medical AG. All rights reserved. HAMILTON-H900