Cotton Humidification Systems. from Samuel Jackson, Incorporated. Copyright 2002 SAMUEL JACKSON, INCORPORATED. All rights reserved

Similar documents
SAMUEL JACKSON DRYING SYSTEMS Background and Design Principles

Introduction to Moisture Restoration

Conditioning Hoppers. Installation and Electrical Wiring Guide

HU King Mesa Gas-Fired Humidaire Unit

Sam Jackson Technical Staff & Network

USTER INTELLIGIN-M APPLICATION REPORT. Monitoring of the ginning process THE GIN PROCESS CONTROL SYSTEM

How about Savings in Time, Money, Energy and Longer Life?

OPERATING AND MAINTENANCE MANUAL

Acrison. Model 515 Polyelectrolyte Preparation Module. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

AEC Sales & Support Research Equipment Phone Fax East Main Street

EN l Senking Batch Transfer Drying Tumbler DT Senking Batch Transfer Drying Tumbler DT High performance with less energy

The All-Inclusive Self-Contained Gas Heated Thermal Fluid Deep Chest Ironer


TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

HG Million Btu/Hr Gas-Fired Heater

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Distributed By: M&M Control Service, Inc Building Technologies

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Competitor Series Dryers

Tower Dryers U Bu/Hr. QuadraTouch Controls Industrial Grade Components

Originators of the Flexible Water Tube design

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS

Continuous mobile asphalt plant

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

engineered for a higher return

Circulating Water Temperature Controller

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

D R Y P O L Y M E R P R O C E S S I N G NORCHEM

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

Technical Installation, Start-up, Operation & Maintenance Manual For ENERGENICS KARTWASH PREMIER WITH TOUCHPAD DISPLAY

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

SERVICE MANUAL STEAMROLLER LINT CONDITIONER (MODELS SR & SR )

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Continuous Mixed-Flow Under FaN Grain Dryers

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

80 Gas Furnaces RAISE YOUR STANDARD OF COMFORT.

Originators of the Flexible Water Tube design

Power Flame Incorporated

Eclipse Self-Check UV Scanner

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

IMPORTANT CONSIDERATIONS

OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Liebert. Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

Direct Fired Heater Model AD Specification

Steam Humidification Light Commercial Applications. Better technology means better business.

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

The Ultimate in Direct Contact Water Heating. by Thermal Engineering of Arizona, Inc. An Inc. 500 Company

SULLAIR DESICCANT DRYERS

EN l JENSEN Transfer Dryer WR JENSEN Transfer Dryer WR Highest Performance with Minimal Use of Energy

BASIL 6700 TUNNEL CAGE WASHER

Discover the Difference

SLATE. Integrated Combustion Equipment Management Success Stories

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

DeLaval Optimat II gain more time and cut your biggest cost

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

Competitor Series Dryers

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

The SKE humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Originators of the Flexible Water Tube design

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability

Standard Features. Convey Dry Blend

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

INTERNATIONAL MACHIINE CONCEPTS. Operating Manual. Tablet Counting and Filling Machine. Model IMC

BASIL 6000 TUNNEL CAGE WASHER

Direct Gas-Fired Make-Up Air

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Boiler Technical Specifications (2013)

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

ASPHALT PLANT. atlasindustries.in

Power Flame Incorporated

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

FORCED AIR HEATING VARIFLAME HEATERS

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

FLAVOUR APPLICATION SYSTEMS

3. Turn on the electrical power supply to the dryer, and move the safety disconnect handle mounted on the dryer s upper power box to on.

Formax technology gives you more productivity

Bulletin , March Electric Hot Gas Bypass Valves

Transcription:

Cotton Humidification Systems from Samuel Jackson, Incorporated Copyright 2002. All rights reserved

A BRIEF WORD ABOUT OUR COMPANY... Samuel Jackson s Lubbock, Texas Factory and Offices Cotton conditioning and Samuel Jackson have been synonomous words for half a century. There is no other company in the world with a greater passion for exploring the effects of moisture as it relates to cotton fiber, developing products to use these effects, and bringing these products to commercial application for the cotton industry. Engineers devoted to discovery of new and better techniques of conditioning fiber for maximum value have many tools to assist them, most important of which is their home location in the heart of the largest cotton producing region of the world. Our manufacturing facility handles all of our metal forming and assembly operations. This permits creative designers to pursue conditioning techniques uninhibited by limitations of off-the-shelf devices. Some of our manufacturing personnel have been with us more than 30 years and their craftsmanship is well-known in a number of different industries. Our small, family owned and operated enterprise is working in most cotton producing regions of the world and welcomes new challenges and the friendships that come from meeting special needs. From the company that brought humid air to the cotton gin first, we welcome you to this view of our newest product line.

HUMIDAIRE UNITS - GAS-FIRED / OIL-FIRED Background and Purpose of the Humidaire Unit The Samuel Jackson Humidaire Unit generates warm humid air which carries water vapor to cotton fibers in a form which is quickly and uniformly absorbed. Samuel Jackson Humidaire Units have been in extensive use since 1959. Both gas-fired and oil-fired models are available. Humid air can be applied at various places in the gin plant. Humid air applied to lint just before the bale press reduces the force required to press out uniform bales and increases lint turn out. Gas-fired Humidaire Unit pictured with 16920 Hot Air Valve Option Humid air applied to the cotton just before the gin stand restores moisture to dry and brittle fiber before fiber-seed separation. This reduces short fiber generated by the gin saws. In very dry climates, humid air applied to seed cotton during pre-cleaning reduces static electricity problems that impede cotton flow. A Unique Mixture of Fire and Water A Samuel Jackson burner provides heated air for the Air is drawn into the Humidaire Unit and around a burner head that heats the air. This hot air enters a stainless steel water spray chamber. In the spray chamber, the hot air is scrubbed, cooled and humidified by a large volume of water circulated through stainless spray nozzles by a 5 HP pump. Zig-zag mist eliminator baffles at the top of the spray chamber allow humid air to leave while retaining water droplets. An external fan (not included) transfers the warm humid air to the place in the gin where it is applied to the cotton. As the water is evaporated from the tank, a float valve refills the tank. A conductivity control system constantly monitors this remaining water and operates a purge/refill cycle to keep the water fresh for low maintenance. Adjustment of the relative humidity of air from the Humidaire Unit controls the amount of moisture applied to the lint. Relative humidity is controlled with two digital temperature controllers that give the operator independent control of dry-bulb and wet-bulb temperatures. The closer these two temperatures are together, the higher the relative humidity. Heated air must pass through a powerful water spray. One controller regulates the burner fuel valve to control the air temperature. The other controller regulates a stainless butterfly valve for throttling water flow to the spray nozzles. Water flow through the nozzles controls the water temperature.

20050 Remote Diagnostic Panel for Humidaire Unit 20500 Dual Digital Temperature Control for Humidaire Unit Operator Controls Operator controls are simple and dependable. They can be installed at the ginner's console or at the press control console. A box is available for mounting them elsewhere. Selector switches turn on the burner and enable the water pump. The water pump starts to run only if the 14900A Lint Flue Scanner or other control indicates that cotton is present. Pilot lights verify that the burner and water pump are operating The 20500 Dual Digital Control allows precise, independent control of the air and water temperatures. This allows the ginner to obtain the desired levels of fiber moisture while eliminating most condensation problems at night or in cold weather. The closer the two temperatures are together, the higher the relative humidity. Each controller shows the desired temperature (SP) and the actual measured temperature. This makes troubleshooting easy. Two alphanumeric displays (at remote and main panel) simultaneously display operation statistics, error history, and alarm notices for remote or local acknowledgement. Electrical Controls and Fuel Valves Electrical controls are in the gasketed top compartment of the cabinet. A microprocessor handles combustion controls, diagnostics, and automatic self-test routines. Diagnostics include automatic gas valve leak testing, automatic testing of electrical interlocks, and monitoring of the water system (water tank level, pump rotation, overload relay, scanner adjustment, and conductivity control adjustment). Electrical Controls in Upper Cabinet The gas valves are located in the lower cabinet. The modulating valve with its actuator closes tightly when power is removed. The gas train, though simple, provides double block for safe, dependable shutoff. Gas Valves in Lower Cabinet

Secret to High Performance A Samuel Jackson Water Valve and Burner Water flow and pressure to the spray nozzles is controlled with a stainless steel butterfly valve. Water pressure before and after the valve is shown on pressure gages. Should the flow of air be choked and other safety controls fail to function, the dual high temperature probes, located above the burner and in the spray chamber, will shut the unit off. Built-in temperature sensors protect the Humidaire Unit from high temperatures nozzles and zig-zag mist eliminator. A heat shield inside the burner duct helps direct heat effectively while protecting outer surfaces from the flame. Cooling air for the heat shield comes through the four holes pictured. A large panel door on the spray chamber front (not pictured) provides easy access to the water tank screen, spray Adjustable four-piece shutters form an aperture to restrict the flow area ahead of the burner to maintain a high velocity of air across the burner head for good combustion. (In the picture, the stainless mesh air inlet screen is removed to show the shutters and the burner head.) The stainless steel water valve is custom machined for long life and reliable operation. The burner orifice is easy to change to adapt to different fuels (natural gas or LPG) and to different maximum outputs. The burner can modulate from the maximum output down to 1/20 (20 to 1 turn-down ratio) of maximum output. The complete spray chamber is constructed of stainless steel. Shown here are spray nozzles, stainless header pipes, and the mist eliminator baffles. Four piece shutters adjust easily to make a beautiful flame

A Machine That Takes Care of Itself A digital water conductivity monitoring and control system prevents scale formation inside the spray chamber, nozzles, pump and circulation pipes. This feature contributes greatly to trouble-free operation and long life of the unit. This will prevent excessive scale formation in the spray chamber of the unit. Purge valve operation is monitored and a special diagnostic alerts the operator if a problem occurs in purging. TRU-Temperature logic (Timed Response Under- Temperature) lets the ginner know when water temperature is inadequate. Clogged water nozzles, among other common maintenance oversights, contribute to low water temperature. The degree of sensitivity may be set by gin management and electronically locked if desired. Positive pressure or gravity drainage systems can be accommodated. This allows drainage or purging of used water to an elevated storage tank if needed. The worm gear connection to the valve will fit a standard garden hose to send purge water anywhere it is needed. A digital conductivity control works closely with the Humidaire s PLC controls to monitor and control water quality. The result is stable water temperature and low maintenance. Stainless steel is used for the water tank, spray chamber, spray nozzles, water pipes, mist eliminator, water and air screens, discharge hood and burner duct to provide long life and attractive appearance. The water purge valve automatically releases used water at 40 psi. This can be sent to drainage or used to compost trash, fill water trucks for the gin yard, or other uses for warm The optional 16920 Hot Air Valve is available for humid air applications with special battery condensers where a source of hot dry air is needed for drying the condenser screen and rollers. This hot dry air can also be used for heating surfaces on the lint slide where condensation is a problem. Heated air is pulled through the valve from the burner duct before the spray chamber by an external fan (not included). The mix valve controls the amount of hot air mixed with ambient air to maintain the desired dry air temperatures. This valve comes with an electric actuator and digital temperature control. The Humidaire Unit is shown here with the 16920 Hot Air Valve Option. This option is popular for battery condenser applications where a source of warm dry air is needed.

The Moisture Mirror Touch Screen System Coordinator The Moisture Mirror brings together a number of existing Samuel Jackson products and coordinates the interaction of new sensors and functions to make moisture control easier and more intuitive for the operator. Screens are easy to navigate with help screens always just one touch away. The Moisture Mirror is designed to easily accept signals from Samuel Jackson sensors and controls. It is also easy to connect sensors from many other manufacturers that have compatible signals. Take a look at the Moisture Mirror s can do list! Incoming cotton moisture sensors can be connected to automatically set appropriate drying system temperatures faster than a human operator can respond. This lets a ginner use lower temperature drying without worrying about surprises. The operator touches the screen to increase or decrease the color bar to fine tune the control to his operating preferences. A user programmable electrical contact is available to signal other devices when wet cotton enters the gin. When a Samuel Jackson Steamroller System is connected, final bale moisture can be automatically controlled with great precision. An embedded sensor option in the Steamroller makes this tight feedback control possible. The operator sets the Target Moisture and The Mirror handles the rest! Brilliant yellow bar graphs show the operator mass flow of seed cotton from the module feeder and the precleaning system when a Samuel Jackson Flow Analyzer is connected to the Mirror. Keep The Mirror close to your module feeder controls, your operator will not want to be without it! Seed cotton moisture after the drying system (located in the overflow hopper) is actively displayed on its own screen and on the summary screen when the Mirror is connected to a Samuel Jackson (or compatible) after-drying moisture sensor. The product would not be complete without letting you view its work. An X-Y graphical plot shows you the past 24 hours of moisture history including incoming seed cotton moisture, after-drying moisture, and final bale moisture.

The Steamroller Lint Conditioning System is the most powerful moisture restoration device for lint cotton in the world. More than 4.1 million bales have had moisture restored with Steamrollers since its invention in late 1996. Ideas from users and designers have been added to further enhance operation. Growers enjoy a big turnout increase. Ginners enjoy pressing a 500 pound bale with no effort. Reduced power consumption and maintenance for the press are nice economic side effects. A 40% reduction in hydraulic pressure to press a bale is not unusual. Automatic tying systems work faster and easier. Bale tie breakage is eliminated when the bales are pressed with high levels of moisture, even 6-tie systems. The Steamroller handles moisture restoration without moist air in the battery condenser. The condenser remains free to do the job it does best, without condensation and hairing on its drum.

Cotton flows from the battery condenser into the Steamroller. Taming a thick, fast moving fluffy batt of cotton is no problem for the large feed-in drum. Fast moving batt entering Steamroller Moist air, generated by a Samuel Jackson Humidaire Unit, completely penetrates the cotton batt inside the Steamroller. The cotton batt is compressed, upon leaving the Steamroller, into a blanket of cotton. This thin uniformly conditioned cotton flows down to the lint slide. Unlike a dry fluffy batt, a compressed batt increases the slide capacity and is easier to charge into the press. High capacity fast, dogless presses require a conditioned batt to press. Without adequate moisture, the cotton will bloom out of the press box during box rotation. Conditioned cotton batt flowing out of Steamroller The Steamroller efficiently forces all of the moist air through the cotton, saving fuel and money in operating the Humidaire Unit. An optional moisture sensor is available to measure the moisture content of the cotton batt flowing out of the Steamroller. The cotton is pressed onto the moisture sensor by the Optional moisture sensor doffer/compression roller. The Steamroller s control system comes with everything required to let it track effortlessly with the battery condenser s drive. The control system allows the ability to easily fine tune the Steamroller s cotton drafting action from the battery condenser for optimal performance. Please contact us for more information on the benefits of moisturizing lint cotton with the Steamroller Lint Conditioning System.

STEAMROLLER LINT CONDITIONER Typical Steamroller Lint Conditioning System Layout

The Lint Slide Grid The Lint Slide Grid is used to humidify cotton as it passes down the lint slide to the baling press. It is composed of stainless steel crosspieces (slats) which overlap to form louver-like openings. Humid air, introduced through the floor of the lint slide beneath the grid, issues from these openings and passes upward through the batt of cotton, adding moisture to it. The overlapping arrangement of the slats helps to push the cotton down the slide as the cotton floats on this bed of humid air and prevents the accumulation of pin trash beneath the grid. The Lint Slide Grid is an exclusive product with us and is the best and most economical method of humidifying the lint in most gins. We invented it in 1976 to replace the prior method of putting humid air in the battery condenser, which caused problems with hairing the condenser screen.

Conditioning Hoppers Double-Entry Conditioning Hoppers protect this gin s cotton from excessive short fiber and damage to staple that occurs when incoming cotton is dry. Humid air enters from two directions for thorough conditioning. When cotton enters a gin too dry, no amount of downward adjustment in drying system temperature can protect the fiber from what happens at the gin stands without fiber protection. Even turning drying burners off will not stop the loss of staple and a sharp increase in short fiber content that occurs when saws take fiber from seed that is dry. For three decades, the Conditioning Hopper, used in conjunction with a Humidaire Unit, has protected fiber properties of cotton in arid regions of the world by humidifying seed cotton before the gin stand. No expensive chemicals are required to enjoy this staple increase and, as a bonus, static charge is eliminated. Installed between the conveyor distributor and the feeder, the Conditioning Hopper works with the Humidaire Unit to expose the seedcotton to humid air before ginning. Longtime users of these hoppers report reduced short fiber content, increased staple length (typically 1/16), and reduced load on the gin stand. Conditioning Hoppers are available to fit most gin stand types and arrangements and, in many cases, can share a Humidaire Unit with the Lint Slide Grid. Double-entry hoppers are available for high capacity gin stands. The double-entry design permits more uniform conditioning in high capacity applications.

THE 2002 SAMUEL JACKSON PRODUCT LINE Samuel Jackson, Inc. announces its product line for 2002. The products listed are the result of precise engineering, quality manufacturing, and rigorous testing. Performance beyond expectations and strong technical support are the hidden ingredients of every member of our product family. The Samuel Jackson team looks forward to serving you with all of your cotton moisture control needs. HUMIDIFYING EQUIPMENT FOR COTTON GINS Humidaire Units Produce warm humid air to increase moisture content of cotton at the lint slide or below the conveyor distributor. All models prompt operator with helpful alphanumeric messages and remember the past 500 events to assist in troubleshooting and optimization. Independent water and air temperature controls provide dependable and precise regulation of output. Scale and buildup is virtually eliminated with pulsed purge system. Humidaires are available in gas-fired and oil-fired models. Steamroller Lint Conditioner The newest technology in cotton moisture restoration. Designed for high capacity gins, the Steamroller efficiently moisturizes and compresses the cotton batt. Each system is custom engineered to ensure maximum performance. Lint Slide Grids An economical method of applying humid air at the press for small to medium capacity gins. Available in packages that include piping, reclamation hood, fans, and tech support. Conditioning Hoppers Installed below the conveyor distributor. Raises the cotton moisture content to protect the fibers from breakage by gin and lint cleaner saws, eliminates static, and increases effectiveness of moisture restoration systems at the press. DRYING EQUIPMENT FOR COTTON GINS Drying Systems We engineer drying systems and guarantee their performance. Samuel Jackson Drying Systems are known worldwide for handling the wettest and most demanding cotton drying applications. Pull-through operation without push fans, use of high air volumes with low air temperatures, and innovative methods of using hot air at the module feeder are characteristics of our cotton drying systems. Advanced touchscreen controls and moisture sensors keep temperatures appropriate for the incoming fiber, safely limited, and highly stable and controlled. Heaters Samuel Jackson Heaters feature advanced combustion control and diagnostics with the same friendly features as our Humidaire Units. All heater models may be used with push fans or in pullthrough systems. Each heater is factory tested and quality inspected; just part of why Samuel Jackson makes the most reliable heaters for cotton gins. Gas-fired Heaters 4 and 8 million Btu/hour sizes. Oil-fired Heaters 4 and 7 million Btu/hour sizes. Can be used on pressure side of push fans or in pull-through systems. Hot Box II This version of the Hot Box fits over the discharge end of a module feeder belt and picks up the cotton in hot air from a separate pull-through heater. No push fan, vacuum feeder, or other motorized components are used. Communication with Samuel Jackson heaters is standard to insure peak operation and record operator actions.

THE 2002 SAMUEL JACKSON PRODUCT LINE PAGE 2 NEW! The Flail for Hot Box II Rotating chains at staggered intervals are mounted above a Hot Box II exit. These chains break wads and disperse stubborn, wet cotton to maximize drying effectiveness. Push Plenums for Gas-fired Heaters Used with push fan rotated to bottom horizontal discharge. Diffuses the air better so burner has improved turndown performance. Also places the burner at a more convenient height. MOISTURE MEASUREMENT AND MISCELLANEOUS CONTROL DEVICES NEW! The Moisture Mirror System Coordinator Adjusts drying temperature automatically by measuring incoming seed cotton moisture. Measures and displays after-drying seed cotton moisture. Displays the flow rate and split of seed cotton coming into the gin from the module feeder. Measures final lint moisture on Steamrollers and adjusts the Humidaire Unit automatically to maintain the desired moisture. Provides a color graph of moisture information from the past 24 hours. Sled Moisture Sensor Device resembles a sled that rides on top of cotton on belt conveyor. Cotton moisture content is measured and sent to a Moisture Mirror (see above) for automatic control of drying system. Moisture Sensors for the Feed Control and Live Overflow These rugged resistance sensor assemblies come with a cotton moisture transmitter assembly to report seed cotton moisture information to the Moisture Mirror (see above). One is mounted inside the feed control bin and the other is mounted in the live overflow bin to accurately sense moisture following the drying process. High Temperature Limit Controls To limit hot air temperature for all Samuel Jackson burners. Flow Analyzer Displays volume of cotton flowing through pre-cleaning system. Useful for balancing load in a split stream precleaning arrangement or for advance visual indication of a cotton surge from the feeder. Requires Moisture Mirror (see above). NEW! The Water Watch Option Displays exact usage of water by a Samuel Jackson Humidaire Unit. Information includes real time values of makeup water and purge water. Also includes evaporation rate over the past 24 hours. Uses standard LCD display included on late mo del Samuel Jackson Humidaire Units (model HU-60-1255 or later). Cotton Moisture Meters Delmhorst hand-held moisture meters are available with module probe, seed cotton cup, and bale probe. Digital readout insures consistent readings. Electric Banjos These units mount on the fan inlets of either pull or push fans to provide full fan performance regardless of material loading or air temperature. They unload the fans automatically to provide soft start and then modulate smoothly to maintain desired motor load as the air system loading changes. Rugged construction provides excellent performance for drying system pull fans and prolongs fan life, even when used for trash duty applications.

This page is intentionally left blank.