SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Similar documents
Spa Control System OWNER S MANUAL

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Air Pump Up to 800 gallons

FLCH4R Garage and Utility Electric Heater

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

A2Z Ozone, Inc. PRODUCT MANUAL

INSTALLATION, OPERATION AND MAINTENANCE

InstructIon Manual KrEs EQuIPMEnt stands

User Manual. Juice Extractor MODEL: WJE2BSLA

e Bath Fan with Light User s Guide

(HSTAT Series) Instruction Manual

Installation, Operation & Service Manual

BLT-999W-2 Item # 60757

e Heater/Exhaust Fan/Light User s Guide

Installation and Operating Instructions

TrueClean ToteCleaner

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

User Manual. Wine Cellar

e Bath Fan with Light User s Guide

IMPORTANT INSTRUCTIONS

Ozone + UV Sanitation

IMpORTANT SAFETy INSTRUcTIONS

DBF 4XL Dryer Booster Fans

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

ELECTRIC FIREPLACE OWNER S MANUAL

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

20 High velocity Air

Outdoor Refrigerator USER S MANUAL

ion Genesis Pump Controller

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

e Bath Fan with Light User s Guide

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

INSTALLATION AND OPERATING MANUAL

R Series B & T2 Model

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

High-Velocity Floor Fan

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

1 HP Air Mover. Owner s Manual

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Xaact Spot. Xaact Hot Spot

OPERATION, SERVICE & PARTS MANUAL

IOM & Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.

MaxLite LED Round Pendant Highbay Series

O w n e r s M a n u a l

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

USER GUIDE. Metal Ceramic Heater NS-HTMCSL6. Before using your new product, please read these instructions to prevent any damage.

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

MDV. Mixing Degas Vessel. For Spa Ozone Generators Installation & Operations Manual Rev.C

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

HotPoly Tote Tank / IBC Heaters (TTH Series)

MN908 No. 282C Replaces 282B LB7013

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

INSTALLATION AND OPERATING MANUAL

IMPORTANT SAFETY INFORMATION:

Operating Instructions (ENG) MODEL: AM115V. Read instructions before operating the machine. AM /24/00

E1.5 ELECTRIC FAN HEATER

INSTALLATION & OPERATING INSTRUCTIONS

Operator s Manual. IP-100 Immersion Probe Cooler

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

OPERATION & INSTALLATION MANUAL

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

CE Approved Portable Dryer Wiring Diagrams. Model: 1200 Series. Electrical Installation Manual PNEG Version: 1.0. Date: PNEG-2119

INSTALLATION AND OPERATING MANUAL

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

SYSTEM CONTROL KIT Model: CK-41P

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTALLATION AND OPERATING MANUAL

MaxLite LED MICRO-T PANEL

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Panel Mounted Heat Exchangers by Dantherm, Inc.

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

IMPORTANT SAFETY INFORMATION:

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

With Remote Control. English

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

OPERATION, SERVICE & PARTS MANUAL

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

(The chances are you re never going to read me) Owner s Manual. Model S10E.

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

OWNE R S MA N UA L. Made in USA. September 2015

Transcription:

SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15

THIS PAGE INTENTIONALLY LEFT BLANK. 2

Operating Instructions and Parts Manual 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Description The Air Blower is designed for outdoor spa applications. It is designed for low noise and a high air flow rate. The unit is UL listed and the motor is protected with a resetting thermal overload device. The blower is designed for permanent electrical connections. The box contains the following: Blower Mounting Bracket UL Approved Check Valve Conduit Cover Plate, Gasket, and Screws Instruction Manual Unpacking/Unit Inspection After unpacking the blower, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts. DAMAGE TO THE UNIT DURING TRANSPORTATION IS NOT THE RESPONSIBILITY OF THE MANUFACTURER. Important Safety Instructions When installing and using this electrical equipment, basic safety precautions should always be followed. READ AND FOLLOW ALL INSTRUCTIONS. Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols: Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. Notice indicates important information, that if not followed, may cause damage to equipment. General Safety Information CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. GENERAL To reduce the risk of injury, do not allow children to use this product unless they are closely supervised at all times. Install blower no less than 1 foot (305 mm) above the maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions. Blower is designed for outdoor use. Install blower at least two feet above the ground in an area free of debris, chemicals, or sprinklers. ELECTRICAL before attempting to install, service, relocate or perform any maintenance. Tag and disconnect power and lock the fuse box / control panel to prevent unexpected application of power. Risk of Electric Shock. Install blower at least 5 feet (1.5 m) from pool / spa water using nonmetallic plumbing. To reduce the risk of electrical shock, connect the green colored wire inside the electrical box to the grounding terminal of your electrical service or supply with a continuous green insulated solid copper conductor minimum No. 8 AWG (8.4 mm2) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit. SAVE THESE INSTRUCTIONS. Installation Guidelines Failure to observe installation guidelines, could result in death or serious injury. See Figure 1 for recommended installation diagram. 1. Install at least 5 feet (1.5 m) from pool / spa water using nonmetallic plumbing. Install blower no less than 1 foot (305 mm) above the maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions. 2. The check valve supplied with the unit must be installed in a vertical orientation above the water level in an easily accessible location for serviceability. Take care to orient the check valve with the arrow pointing in the direction of the air flow inside the pipe. 3. Use a separate dedicated 2-inch rigid PVC supply line from the blower to the spa. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. 3

Operating Instructions and Parts Manual Hartford Loop required if Blower is more than 25 feet away from pool / spa Alternate location for check valve if Harford Loop is used 5 Foot minimum from water (use non-metallic plumbing) Conduit box and cover Non-metallic electrical tubing Orient blower housing as shown Bracket Wall or post Grade 12 inch minimum 24 inches above surrounding grade / 12 inch minimum above water Check valve (location when NOT using a Hartford Loop) Rigid PVC pipe Air flow Figure 1 Installation Guidelines (Continued) Do not glue the blower to the supply line. Glue fumes can potentially cause an explosion when the blower starts. Install a 1/4 self-tapping screw to secure the joint if necessary. Do not install blower below water level. Blower must be at least one foot above the maximum water level. 4. Mount blower in a vertical position using vertical rigid PVC pipe as shown in Figure 1. For additional support use supplied bracket as shown in Figure 1. For warm climates, try to locate the blower in a shaded location. If the blower is to be installed more than 25 ft from the spa, it will be necessary to install a loop that is 1 foot above the water line and as close to the spa as possible (See Figure 1). A loop and a check valve must be installed at least one foot above the water level when supercharging water jets. Mount using rigid PVC pipe. For additional support, use supplied bracket as shown. 5. Verify plumbing is free of leaks before adding water to spa. 6. Do NOT install adjustable jets. Adjustable jets can cause excessive back pressure within the unit. 7. Hydrotherapy jets naturally aerate when installed correctly. Do not use blower to supplement aeration when jets have been installed incorrectly. Wiring Guidelines Failure to observe wiring instructions, could result in death or serious injury. All wiring and electrical connections must be performed by a qualified electrician. Installations must be in accordance with local and national codes. 1. For electrical ratings, see product decal. 2. Check the line voltage to make certain it is correct for the blower being used. Do not attempt to connect 240 VAC to a 120-volt blower; it will damage the blower and void the warranty. 3. Refer to the National Electric Code Guidelines for wire size and to prevent electric shock. 4. Refer to the National Electric Code Guidelines for proper selection of wiring conduit and strain relief. 5. The blower field-wiring box is designed for non-metallic electrical tubing only. Refer to the National Electric Code Guidelines for proper selection of wiring, and strain relief. 6. Be certain to connect the green ground wire supplied with the blower to the ground from your electrical panel. 7. Connect remaining line wires individually to the remaining wires in the blower. 8. When wiring is complete carefully install gasket and conduit cover plate. Overheating, shortcircuiting and fire damage will result from inadequate wiring. 4

Blower Sizing The number of holes in the seats and floor of the spa can be used to determine the size of the air blower that will be required for your application. See Chart 1 for recommended blower size based on the number and size of holes. Water Jet Applications The blower can be used to boost the output of hydrotherapy jets. A venturi fitting is normally incorporated into the jet design. The purpose of the fitting is to allow air to mix with the water in the jet. The venturi fittings can be connected together and then pressurized with air from the blower to greatly increase the jet action. New Spa Applications It is important to select a water pump that will supply sufficient flow to the jets. Consult with the jet manufacturer for assistance in selecting a pump or pumps that will accommodate the number of jets desired in the spa. Improper sizing can cause overheating of the pump and blower. Choose the correct size blower based on the number of water jets in your spa (see Chart 1). See the chart below. Refer to the installation guidelines for additional details. 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX Winterizing The blower is designed for outdoor use. There are no special off-season requirements for the blower. In some spa systems it is possible to protect discharge lines from freezing by operating the blower for several minutes with the spa drained. The airflow can be used to purge water from the air lines. Blower Model Total Hole Area Square Inches Recommended Number of Holes at the Following Hole Diameters 1/8 Inch 3/16 Inch 1/4 Inch Number of Water Jets 80018-XXXX, 80015-XXXX 1.0 76 35 20 4 to 9 9 to 13 14 or more 80019-XXXX, 80016-XXXX 1.4 100 46 26 80020-XXXX, 80017-XXXX 1.8 150 68 38 Chart 1 Notes 5

Operating Instructions and Parts Manual Troubleshooting Chart - All repairs must be completed by licensed or certified professionals. Symptom Possible Cause(s) Corrective Action(s) Safety Alert Blower will not start 1. Power Off 2. Internal blower overload trips 3. Brushes worn out 4. Nuisance trips 1. Check electrical connections and fuse box / control panel 2. then check for restrictions or blockage in air discharge line 3. Replace motor 4. It is possible that if the blower is started and stopped repeatedly in a short time period, the thermal overload could interrupt the circuit. Allow the unit to cool and disconnect power. Restart after 5-15 minutes (depending on warmth of ambient conditions). Blower hums but will not run 1. Rotor locked 2. Brushes worn out 3. Wrong voltage 1. then check for debris or foreign object lodged in blower motor 2. Replace motor 3. Verify voltage is correct for blower Blower runs but delivers little air 1. Low voltage 2. Blower too small for application 3. Check valve installed incorrectly 1. Check electrical connections Verify voltage is correct for blower 2. Install additional blowers, or reduce piping restrictions 3. Re-orient check valve Internal blower overload trips 1. Blocked or restricted air line 2. Check valve installed incorrectly 1. Check for debris or foreign object lodged in discharge line 2. Re-orient check valve Blower runs too slow 1. Incorrect line voltage 2. Incorrect wire size 1. Check blower voltage requirements, make certain line voltage is correct 2. Verify correct wire gage is being used 6

80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX Replacement Parts List For Replacement Parts, call 1-877-278-2797 Please provide following information: - Model number - Serial number (if any) - Part descriptions and number as shown in parts list 1 3 2 5 4 6 7 8 9 Ref. No. Description Parts Number QTY. 1 Conduit Cover Plate, Gasket, 2 Screws, and Wiring Diagram (Kit) 81008-001 1 2 Blower Housing with Foam Inserts (Kit) 81006-001 1 3 Bracket 28569-001 1 4 Gear Clamp 67111-001 2 5 Motor 1 1 hp 120v 81000-001 1 hp 240v 81003-001 1-1/2 hp 120v 81001-001 1-1/2 hp 240v 81004-001 2 hp 120v 81002-001 2 hp 240v 80002-001 6 Sleeve 15497 1 7 Discharge Housing 28555-001 1 8 8-16 x 3/4 inch Plastite Screw 67007-001 8 9 Check Valve 10116-001 1 7

Operating Instructions and Parts Manual LIMITED WARRANTY For one (1) year from the date of purchase, the manufacturer will repair or replace, at its option, for the original owner any parts of its Blower ( Product ) which are found upon examination by the manufacturer to be defective in materials or workmanship. This Limited Warranty covers labor for a period of one (1) year for Product sold and installed in the United States (does NOT cover service labor for removal and reinstallation of the blower). Please call 1-877-278-2797 for instructions. Be prepared to provide the model number and serial number when exercising this limited warranty. Purchaser must pay all transportation charges on Products or parts submitted for repair or replacement. All non-warranty service charges are the responsibility of the original owner. Failure to pay for non-warranty service charges will void this Limited Warranty. This Limited Warranty does not cover Products that have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance or failure to operate in accordance with the manufacturer's written instructions. All maintenance and service must be performed by service agents approved by the manufacturer. Any unauthorized alteration or repairs will void this Limited Warranty. THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE (1) YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall the manufacturer or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer's customers for such damages. This Limited Warranty does not include freight charges for equipment or component parts, to and from the factory, services such as maintenance or inspection, repair or damage due to negligence such as freezing conditions, incorrect installation, nor acts of God. It also does not include refrigerant or other expendable materials. The liability of the manufacturer shall not exceed the repair or replacement of defective parts under this Limited Warranty. This Limited Warranty also does not include unnecessary service calls due to erroneous operational reports, external valve positions, or electrical service. If a non-warranty service call is made, and the homeowner is unwilling to pay for the service call, this Limited Warranty will be voided. This Limited Warranty is voided if the product is repaired or altered by any persons or agencies other than those authorized by the manufacturer. This Limited warranty applies only within the continental USA. For warranty outside the continental USA, contact the manufacturer. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST present a copy of the purchase receipt at the time of service. Please call the manufacturer at 1-877-278-2797 for service or return authorization and instructions. DO NOT MAIL THIS FORM TO the manufacturer. Use this form only to maintain your records. MODEL NO. SERIAL NO. INSTALLATION DATE 8