Installation instructions

Similar documents
CoreLine Panel the clear choice for LED

Reflector T2 and GU10 6,000 hours

SmartBalance recessed combining performance with smart design

SmartBalance Free Floor Standing combining performance with smart design

TBS165 affordable and efficient

SmartBalance Free Floor Standing. combining performance with smart design. Benefits. Features. Application. Specifications

EC-Declaration of Conformity Annex

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

performance PowerBalance, surface mounted Benefits Features Application Specifications

1. Key Features and Benefits

This annex is valid from: to Replaces annex dated: Prolonged until

CoreLine Wall-mounted the clear choice for LED

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

ClearAccent - Affordable recessed LED spot

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

CoreLine Waterproof the clear choice for LED

Fortimo LED Line Gen2 Module

CoreLine Batten the clear choice for LED

With this symbol Gavita declares that this product complies with legal European requirements.

EU Declaration of Conformity Annex

EU Declaration of Conformity Annex

High-performance LED Elbow spot

Joint CELMA / ELC Guide on LED related standards

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

EU Declaration of Conformity Annex

LED Shoplight fixture

CoreLine Recessed Spot the clear choice for LED

Fortimo LED Line High Flux Module

GAN Electronic 750W/1000W DE EU

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

Test Lamp for 210 series flame detectors Non EX

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

ProAir an unrivalled combination of light quality and efficiency

ELLA ID. High CRI, High lm/w OptoDrive LED-module

StoreFlux powerful LED accent lighting that blends perfectly in the store architecture

2015 /9C EN-00 OSRAM GmbH Marcel-Breuer-Str München Germany. LED module PL-LIN-HV-DC-G1. M see attached list

Affordable and reliable energy saving LED Lighting Luminaires

SmartForm top-class lighting in a fresh, appealing design

Downlight ENCORE DL6 15W 2700K

EC-Declaration of Conformity

EU Declaration of Conformity Annex

EC-Declaration of Conformity

LED Linear Design Highlights

SmartForm the new standard for office lighting with modular recessed luminaires

Five ways to save energy. Sales Director Thorn Energy Solutions

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

2014 / ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. OSRAM Lamp controlgear QUICKTRONIC. M See attached list

LED Product Catalogue

2013 / ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. OSRAM LED module LF05A/E-P. M See attached list

RE-PR3-E-27 3-Phase Panel Mount 27kW

Ledinaire Batten Simply great LED

STS Directory Accreditation number: STS 0009

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

SmartForm the new standard for office lighting with modular recessed luminaires

EC-Declaration of Conformity OSRAM J

WARRANTY LED ECO PANEL.

Premier External TD. Installation Manual INS352-3

LPCMPIRM65 & LPCMPIRDSI65

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

Product Compliance Andy Guest

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CoreLine Recessed Spot the clear choice for LED

EU Declaration of Conformity

LED SUPERSTAR MR16 35 ADV 24 /36 Product description

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Installation Instructions. Mira LED Light System

LED ECO PANEL.

EC-Declaration of Conformity

High bay LED lighting fixture

Directions for use MACH LED 300DF

TROFFER RETROFIT KIT (TRK)

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

Mains-related EMC-issues associated with Lighting Equipment. P.A. Beeckman PGI/Philips Innovation Services EMC Kennismarkt Oost - October 12, 2012

3kW 6kW, QUBE Fiber Lasers

THINTEK G2 PANEL.

THINTEK G2 PANEL.

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

ISCG90SS _03 ISCG90SS

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

Tri-level Control HF Sensor

EasyAir office sensor advanced grouping SNS200

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Product Tests Report

IT Istruzioni di montaggio e d'uso EN Instruction on mounting and use DE Montage- und Gebrauchsanweisung FR Prescriptions de montage et mode d emploi

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. Auxiliary Equipment LS/PD AP KIT. See attached list

LED ECO PANEL.

LED ROUND MINI PANELS

EU Declaration of Conformity Lampenwerk Wipperfürth

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

HIGH LUMINOUS EFFICIENCY

EC-Declaration of Conformity

Transcription:

SmartBalance Wall-mounted WL484W Installation instructions Instructions de montage Montageanleitung Montage instruktie Istruzioni di montaggio Instrucciones de montaje Instruções de montagem Monteringsinstruktioner Monteringsvejledning Kokoonpano- ja kiinnitysohjeet Montaj yönergesi Οδηγι ες συναρµολο γησης Instrukcja montazu Szerelési utasítások Návod k montázi Návod k montáži

Contents 1. General information...3 1.1. Designated use...3 1.1.1. Intended purpose...3 1.1.2. Location...3 1.2. Disclaimer...3 1.3. Product family code configuration...3 2. Safety instructions...4 3. Abbreviation and symbols...4 4. Installing wall bracket...5 5. Electrical connections...6 6. Installing light unit...8 7. Settings... 10 8. Cleaning... 10 9. Technical data... 10 10. Approbation... 11 Installation instructions - WL484W 2

1. General information 1.1. Designated use! 1.1.1. Intended purpose The intended purpose of this luminaire is for use in general lighting areas, offices, corridors and health care applications. The luminaire may be used in medical areas (in accordance with EN 60598-2-25). It is not intended for use in operating rooms. 1.1.2. Location For indoor use only. 1.2. Disclaimer The manufacturer cannot be held liable for damage caused if the luminaire is used for purposes other than the intended purpose or if safety instructions and warnings are ignored. 1.3. Product family code configuration WL484W LED52S/830 PSD D/I RLY D26 SW SI Product family code Total lumen output CRI CCT Driver type Light source configuration EFE current pulse control Dimming via external powerline (night light) Dimming switch Housing color Product family code WL484W Total lumen output 52S (5200 lumen total output) CRI 8 (CRI80) CCT 30 (3000K) 40 (4000K) Driver type PSD (DALI dimming ballast) Light source configuration D/I (Direct & indirect light) IND (Only indirect light) EFE current pulse control RLY (EFE pulse control single Luminaire) (No EFE pulse control) Dimming via external powerline (night light) D26 (Night light function via separate relay) (Night light via DALI) Separate switchable SW (Direct and indirect are separately switchable) (No separately switchable light source) Housing color WH (White) SI (Silver) Installation instructions - WL484W 3

2. Safety instructions! When using luminaires of protection class I make sure that the grounding conductor is connected to the luminaire wall bracket. Apart from the relays in the wall bracket (not all versions), no other part in the luminaire is serviceable by the user. Please contact your Philips representative for service of defective parts. Maintenance instructions To assure the lighting quality of this unique LED lighting concept there are only a few instructions regarding the maintenance of this luminaire: Do not touch electronic components! Electronic components are under high voltage. Electronic components are ESD sensitive. During installation or when maintaining the luminaire. always use static-free gloves to avoid marks on the luminaire. To remove dirt and spots use the following: -- Dust: only use microfiber cloths. -- Fingerprints, etc.: use a cleaner for synthetic materials with antistatic properties. Do not stare into the LED light beam. A SmartBalance luminaire with DALI driver also supports Touch and Dim functionality. This luminaire should not be used for illumination during building activities due to dirt and dust contamination.! ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES 3. Abbreviation and symbols IEC lighting protection class I (protective ground) Dispose of separately in accordance with 2002/96/EC (WEEE - Waste Electrical and Electronic Equipment) CE conformity marking Designed for indoor use only Installation instructions - WL484W 4

4. Installing wall bracket Note: Only certified installers should carry out mounting and installation. The WL484W can be mounted by one person. The supply voltage must correspond to the voltage shown on the product label. The wall bracket is only suitable for use on walls that are either solid or supplied with a suitable high-strength wall-mounting solution. Attach the wall bracket with the correct screw or bolt for the type of wall. Preferably use the holes that are farthest apart. Use washers to ensure that the screws/bolts hold well. Distance A : 600 mm Distance B : 100 mm Dimensions of rear cable entry: 500 x 22 mm. Please note: the space directly behind the connection terminal is limited. The best place for cables to enter is between the two connection terminals. Connection terminals Installation instructions - WL484W 5

5. Electrical connections WL484W LEDXXS/8X0 PSD D/I RLY D26 SW XX 15 16 1 2 3 4 5 Direct light mains Direct light switches Night light switch Indirect light mains 6 7 8 9 10 DA- DA+ GND N2 L2 11 12 13 14 Door L2 Door Sw Bed 1 Bed 2 15 16 NL-L NL-N 1 2 3 4 5 L1 N1 GND DA+ DA- WL484W LEDXXS/8X0 PSD D/I SW XX 6 7 8 9 10 1 2 3 4 5 Direct light mains Indirect light mains 6 7 8 9 10 DA- DA+ GND N2 L2 1 2 3 4 5 L1 N1 GND DA+ DA- Installation instructions - WL484W 6

WL484W LEDXXS/8X0 PSD IND XX 1 2 3 4 5 Indirect light mains 1 2 3 4 5 L1 N1 GND DA+ DA-! Make sure the cables are stripped to the correct length and run along the back of the wall bracket as far as possible (see below). The luminaire has limited room for excess wire length or multicore cables with thick insulation. Excess cable length may prevent the light unit from sliding completely over the wall bracket. Installation instructions - WL484W 7

6. Installing light unit Wall bracket Light unit With the Philips logo face up, slide the light unit over the wall bracket until the internal hooks on either side snap onto the wall bracket. Now connect both 6-pole connectors, located on the far-left and far-right sides of the luminaire (only on the far-right side of the direct light version). Make sure that all wires are placed inside the wall bracket, and slide the light unit farther over the wall bracket until both holes in the plastic optical cover are aligned with the mounting holes in the wall bracket.! Warning! If considerable force is required to slide the light unit all the way to the wall or if it springs back, there is most likely a trapped wire or connector in the way: make sure to place the wires in the back side of the luminaire and avoid excess length. Installation instructions - WL484W 8

Screw Screw Fasten the light unit to the wall bracket with both supplied screws. These screws only need to prevent the luminaire from sliding back away from the wall and only need to be secured hand-tight. Maximum torque: 0.5 Nm! Warning! Only tighten these screws with a manual screwdriver. Do not use power tools. Installation instructions - WL484W 9

7. Settings Before putting the luminaire into service, if applicable, program the desired scenes into the DALI/DMX controller for the luminaire. Depending on the luminaire type, dimensions of the room and reflective properties of the walls and ceiling, it may be necessary to change the output levels to reach the desired lux levels. 8. Cleaning Note: Periodic cleaning of the faceplate results in improved light efficiency. Use regular glass cleaner. Do not use concentrated disinfectant or a solvent. For cleaning the other outer surfaces, use a cloth dampened with any usual cleaner. Check the compatibility of the cleaner with lacquer and plastics before use. The following cleaning agents have been tested or declared compatible by the supplier and are safe to use when diluted according to the instructions: Terralin Protect (Schülke) Antifect Extra (Schülke) Hexaquart plus Observe all applicable local regulations. Clean with a damp cloth only; spraying is not allowed. 9. Technical data Connection Push in Nominal voltage / freq range 230 V 50/60 Hz Ingress protection code (installed luminaire) IP 40 Glow wire test ( C) 650 Net weight each (kg) Max 6.0 kg Ambient temperature (transport and storage) -20 C to +70 C Ambient temperature (operating) 0 C to +35 C Relative humidity Max. 90% Inrush current (per driver) 48 A (max.) Mains current pulse-time half peak 180 µs Ground fault current 0.7 ma (max) Number of drivers on MCB (16A type B) 20 max (indirect only 24 max) Number of drivers connected to one 30 ma residual current detector 30 max Indirect light driver Direct light driver Inrush current Ipeak 22 A 21 A Inrush current Twidth 275 µs 255 µs Ipeak Twidth Installation instructions - WL484W 10

10. Approval The designated product: WL484W LED52S/830 PSD D/I RLY D26 SW SI is/are in conformity with the essential requirements of the following European Directives and harmonized standards: Low Voltage Directive (LVD), 2006/95/EC EN 60598-2-1 Edition 7.0 2008-04 Fixed general purpose luminaires EN 60598-2-25 Edition 1.0 1996-08 Luminaires for use in clinical areas of hospitals and health care buildings IEC 62031 Edition 1.0 2008-01 LED Modules for general lighting Electromagnetic Compatibility Directive (EMC), 2004/108/EC EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting EN 61547 Equipment for general lighting purposes EMC immunity requirements EN 61000-3-2 Limits for harmonic current emissions (<16A per phase) EN 61000-3- 3 Limits for voltage fluctuations and flicker Additional IEC 62471-2 Photobiological safety of lamps and lamp systems (Issue date 08/2009) IEC62722-2-1 Luminaire performance - Part 2-1: Particular requirements for LED luminaires IEC62717 LED modules for general lighting - Performance requirements Specification The factory is certified in accordance with: Quality Management System ISO9001:2008 Certificate no. GB/10/81148.00 issued by SGS Environmental Management System ISO 14001 Occupational Health & Safety Management System OHSAS 18001 The in-house laboratory is accredited by DEKRA Testing and Certification for Supervised Manufacturer's Testing in compliance with ISO/IEC 17025 Restriction of the use of certain Hazardous Substances in electrical and electronic equipment Directive (RoHS), 2011/65/EC EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Sample(s) has/have been type tested by: Philips Lighting B.V., Winterswijk, The Netherlands Installation instructions - WL484W 11

The designated product(s) WL484W LEDXXS/840 PSD D/I SW WH WL484W LEDXXS/830 PSD D/I SW WH WL484W LEDXXS/840 PSD D/I SW SI WL484W LEDXXS/830 PSD D/I SW SI WL484W LEDXXS/840 PSD IND WH WL484W LEDXXS/830 PSD IND WH WL484W LEDXXS/840 PSD IND SI WL484W LEDXXS/830 PSD IND SI is/are in conformity with the essential requirements of the following European Directives and harmonized standards: Low Voltage Directive (LVD), 2006/95/EC EN 60598-2-1 Edition 7.0 2008-04 Fixed general purpose luminaires EN 60598-2-25 Edition 1.0 1996-08 Luminaires for use in clinical areas of hospitals and health care buildings IEC 62031 Edition 1.0 2008-01 LED Modules for general lighting Electromagnetic Compatibility Directive (EMC), 2004/108/EC EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting EN 61547 Equipment for general lighting purposes EMC immunity requirements EN 61000-3-2 Limits for harmonic current emissions (<16A per phase) EN 61000-3-3 Limits for voltage fluctuations and flicker Additional IEC 62471-2 Photobiological safety of lamps and lamp systems (Issue date 08/2009) IEC62722-2-1 Luminaire performance - Part 2-1: Particular requirements for LED luminaires IEC62717 LED modules for general lighting - Performance requirements Specification The factory is certified in accordance with: Quality Management System ISO9001:2008 Certificate no. GB/10/81148.00 issued by SGS Environmental Management System ISO 14001 Occupational Health & Safety Management System OHSAS 18001 The in-house laboratory is accredited by DEKRA Testing and Certification for Supervised Manufacturer's Testing in compliance with ISO/IEC 17025 Restriction of the use of certain Hazardous Substances in electrical and electronic equipment Directive (RoHS), 2011/65/EC EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Remarks: XX = the declaration of conformity is valid for all lumen packages between LED30S and LED52S in these types. The notified body, DEKRA, conducted ENEC05 and issued certificate no. 2179701.01. Sample(s) has/have been type tested by: Philips Lighting B.V., Winterswijk, The Netherlands Installation instructions - WL484W 12

2015 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. (Royal Philips) or their respective owners. 08 / 2015 www.philips.com/lighting