MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual

Similar documents
MS200/300/400 Magnetic Stirrer. Instruction Manual

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Digital 7 Square Plate Magnetic Stirrer

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Reacti-Therm I and III Heating/Stirring Modules

MD-MINI Dry Bath. Instruction Manual

Intelli-Stirrer MSH-300i Magnetic Stirrer with hot plate

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

PS-3401 Heater / Stirrer

Magnetic Stirring Systems with Heat

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Digital Heat Block User Manual

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Reacti-Therm I and III Heating Modules

JENCO ELECTRONICS, LTD.

User Manual. 10-Channel Analog Hotplate Magnetic Stirrer MS-M-S Channel Analog Magnetic Stirrer

TS-100C. Thermo-Shaker with cooling for microtubes and PCR plates. Operating Manual Certificate. Medical Biological Research & Technologies

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Hotplate/stirrers. Hotplate stirrers

OPERATING MANUAL. EchoTherm DIGITAL HOT PLATES and HOT PLATE/STIRRERS MODELS HP50, HP50A, HS50, HS50A, HP51, HP51A, HS51 and HS51A For All Voltages

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

i-cube Microplate Incubator E10030

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Professional Series. Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers

Humidity Monitor model 01080

DOC JAN06 LT 200

HI COD REACTOR and Test Tube Heater 2008 Series

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

TRAVELMATE. Instruction Manual

Manual Vane Anemometer PCE-VA 20

User Guide. Shaft Speed 6 6-Channel Shaft Speed Monitor. Calibration and Operation Software Reference UDJ701-5

Pasto Sous vide water bath

Hotplates, Magnetic Stirrers and Stirring Hotplates

Black Body Calibration Source User Manual

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Instruction Manual QUICK 855PG PROGRAMMABLE SMD REWORK STAION

HRS55PG PROGRAMMABLE SMD REWORK STAION. Instruction Manual. Thank you for purchasing our SMD Rework station. The unit is exclusively designed for

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

IMR IX176 Portable Gas Detector User Manual

Thermometer with Wired Sensor

TRAVELMATE FRIDGE FREEZER Instruction Manual

USER MANUAL. Adventure Kings 50L Refrigerator

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

FEATURES AND SPECIFICATIONS

High Temperature InfraRed Thermometer with Laser Pointer

BD Viper Lysing Heater Manual (for BD Viper System)

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

KEM Scientific, Inc. Instruments for Science from Scientists

Dual Laser InfraRed (IR) Thermometer

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Ingenieurbüro M.ZippererGmbH

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

ROTARY VACUUM EVAPORATOR RVO 004

Thermometer with Probe model 00891A

Operator s Manual. The Quietek

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

Micro-Computer Induction Cooktop SR-964T INSTRUCTION MANUAL. Thank you for your purchase.

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

HIn3550 Magnetic Field Monitor User's Manual

Portable Refrigerator

Thermal Electric Wine & Beverage Chiller. Model: WC-20TL (20 Standard Bottle Capacity) Instruction Manual

Air-Quality Detection Module. User s Manual

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

Thermometer model 02059

Ambient Weather WS-25 Wireless 8-Channel Floating Pool and Spa Thermometer with Indoor Temperature and Humidity User Manual

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Digital Cooking Thermometer models / 00282

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

OPERATING MANUAL. EchoThermJ DIGITAL HOT PLATE MODEL HP30 AND HP30A. DOCUMENT NUMBER HP30-03 Revised 10 December 2011

Dry Bath Heating Systems

Operating Instructions

FGT5 & FGT6 Gelation Timer. Instructions for use

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Digital Refrigerator/Freezer Thermometer model 00986

Chemical resistant Vacuum Pumps

DC COMPRESSOR FRIDGE-FREEZER Grape Glacier 2.75 INSTRUCTION MANUAL ENGLISH

User's Guide. Pinless Moisture Meter. Model MO257

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Operation Manual Digital Heating Hotplate HP-1D

Medical Refrigerator

AlcoBlow. User Handbook

TOQUE BLANCHE GRANDE CARTE

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015



Transcription:

MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual BANTE INSTRUMENTS CO., LTD

MS200/300/400 Hotplate Magnetic Stirrer 1 Introduction Thank you for selecting the MS series magnetic stirrer. This manual provides a step-by-step guide to help you operate the stirrer, please carefully read the following instructions before use. Unpacking The following list describes the accessories of stirrer. After the unpacking, please check all accessories are complete. If any are damaged or missing, please contact nearest distributor. Stir Bar Temperature Probe (Only for MS300/400) Stirring the Liquids Before plugging the plug into the power outlet, ensure that the local mains power voltage matchs the stirrer requirements. 1. Place the stir bar into the container. Press the power switch to ON position, the display will light up. ON OFF 2. Press the or key to set the stirring speed, the speed bar on display will show the run status. 3. If the stirrer does not work well, move the container slightly, ensure that the stir bar is always in the center of container.

MS200/300/400 Hotplate Magnetic Stirrer 2 Setting the Stirring Time MS series magnetic stirrer has a built-in timer that allows user to set the stirring time from 1 to 999 minutes. 1. Press the Time key to enter the setting mode, the display shows 000 min. 2. Press the or key to set the stirring time, press the Enter key to confirm. The timer automatically begins countdown until it gets to zero, the stirrer will stop the stirring simultaneously. If you want to exit the setting, press the Exit key. Heating the Liquids This section is applicable to MS300 and 400 magnetic stirrers. 1. Insert the connector of temperature probe into the corresponding connector socket on the rear panel of stirrer. 2. Place the temperature probe into the liquid. 3. Press the o C key and the or key to set the target temperature, press the Enter key to confirm. The stirrer is now begin heating.

MS200/300/400 Hotplate Magnetic Stirrer 3 NOTE: Ensure that the temperature probe is connected to socket, the hotplate will not heat if the probe is not attached. While heating a liquid the temperature probe must be immersed, otherwise the hotplate will heat continuously and will go into a fault condition. During the heating mode, the Heating icon will successively show as follows: When the liquid reached the setting temperature, the Heating icon will flashing continuously. Press the Exit key, the stirrer stops the heating immediately. Temperature Calibration During the heating, if the temperature reading displayed differs from that of an accurate thermometer, please follow the steps below to calibrate the stirrer. 1. Switch off the stirrer. 2. Press and hold the and keys for 3 seconds, then switch on the stirrer. The display will show the temperature value. 3. Press the or key to correct the temperature value, press the Enter key to confirm. Calibration is completed. Troubleshooting FAILURE Stir bar does not working Can not heating CAUSE Check the screw under the top plate are loose. Container is not in the center of top plate. The temperature probe is not connect to stirrer. Heater or temperature probe has damaged.

MS200/300/400 Hotplate Magnetic Stirrer 4 Specifications Model MS200 MS300 MS400 Maximum Stirring Volume Stirring Speed 2 Liters (H2O) 0 to 1250 rpm Temperature Range No temperature control Room temperature to 300 C Room temperature to 400 C Timer Range Top Plate Size Power Requirements Ambient Temperature Dimensions Weight 0 to 999 minutess 135 (L) 135 (W)mm AC220V/50Hz < 50 C 230 (L) 180 (W) 120 (H)mm 2.2kg

Hazardous Substance Statement Bante Instruments is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium, lead, mercury and the like. New technologies and design parameters are also promoting these efforts and we expect to have little or no such materials in our product in the coming years. We welcome our customer suggestions on how to speed up these efforts. Warranty The warranty period for stirrer is one year from the date of shipment. Above warranty does not cover the stir bar and temperature probe. Out of warranty products will be repaired on a charged basis. The warranty on your stirrer shall not apply to defects resulting from: Improper or inadequate maintenance by customer. Unauthorized modification or misuse. Operation outside of the environment specifications of the products. For more information, please contact the nearest authorized distributor. BANTE INSTRUMENTS CO., LTD E-mail: banteinstruments@yahoo.com Phone: +8621-6404-1598 Website: www.bante-china.com The information in this document is subject to change without notice. Copyright Bante Instruments, 2018. All rights reserved.