AS/NZS IEC :2015

Similar documents
AS/NZS 3133:2008 AS/NZS

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

AS/NZS TR IEC :2012

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

AS/NZS :2014

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

AS/NZS :2014

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

AS/NZS 4012:1999 AS/NZS

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :1995. Emergency escape lighting and exit signs for buildings AS/NZS :1995. Part 2: Inspection and maintenance

AS/NZS :2015

AS/NZS :2012. Regulatory compliance mark for electrical and electronic equipment AS/NZS :2012. Part 1: Use of the mark

Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS :2008

AS/NZS IEC 62560:2014

Australian/New Zealand Standard

AS/NZS :2016

AS/NZS IEC :2016

AS/NZS 4234:2008 AS/NZS

AS/NZS 3190:2011 AS/NZS

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

AS/NZS IEC :2013

AS/NZS :2009

AS/NZS :1998 AS/NZS ISO

AS/NZS 3957:2006 AS/NZS

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

AS/NZS :2011. Household and similar electrical appliances Safety AS/NZS :2011. Part 1: General requirements

AS/NZS :2014

Household and similar electrical appliances Safety

Australian/New Zealand Standard

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

Australian/New Zealand Standard

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016

Australian/New Zealand Standard

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

AS/NZS IEC :2016

Australian/New Zealand Standard

AS/NZS :2014

Australian/New Zealand Standard

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

Australian/New Zealand Standard

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508

Australian/New Zealand Standard

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

AS/NZS ISO/IEC :2012

Australian/New Zealand Standard

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

AS/NZS 2: 1067:2003 AS/NZS

Australian/New Zealand Standard

AS/NZS TR IEC :2012

Australian/New Zealand Standard

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

AS/NZS IEC :2014

Australian/New Zealand Standard

Australian/New Zealand Standard TM

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Australian/New Zealand Standard

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Australian/New Zealand Standard

AS AS Australian Standard. Installation of fire hose reels. This is a free 6 page sample. Access the full version online.

Australian/New Zealand Standard

Substations and high voltage installations exceeding 1 kv a.c.

Australian/New Zealand Standard

Australian/New Zealand Standard

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

AS/NZS :2016. Explosive atmospheres AS/NZS :2016. Part 7: Equipment protection by increased safety e. Australian/New Zealand Standard

Australian Standard. Fire detection and alarm systems. Part 6: Carbon monoxide fire detectors using electro-chemical cells

Interim Australian Standard

Australian Standard. Fire detection, warning, control and intercom systems Control and indicating equipment. Part 1: Fire

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

AS AS Australian Standard. Potting mixes. This is a free 7 page sample. Access the full version online.

Medical electrical equipment

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

AS AS Australian Standard. Soils for landscaping and garden use. This is a free 7 page sample. Access the full version online.

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d

Australian/New Zealand Standard

AS Australian Standard. Guards and patrols. This is a free 6 page sample. Access the full version online.

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

Australian Standard. Security screen doors and security window grilles AS AS 5039

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

Medical electrical equipment

AS/NZS :2016

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

Australian/New Zealand Standard

SOUTH AFRICAN NATIONAL STANDARD

Australian Standard. Fire protection for mobile and transportable equipment AS AS

Australian Standard. Safeguarding of machinery

Transcription:

AS/NZS IEC 60947.5.6:2015 (IEC 60947-5-6, Ed. 1.0:1999, IDT) Australian/New Zealand Standard Low-voltage switchgear and Part 5.6: Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) Superseding AS/NZS 3947.5.6:2000 AS/NZS IEC 60947.5.6:2015

AS/NZS IEC 60947.5.6:2015 This joint Australian/New Zealand standard was prepared by joint Technical Committee EL-006, Industrial Switchgear and Controlgear. It was approved on behalf of the Council of Standards Australia on 27 May 2015 and on behalf of the Council of Standards New Zealand on 4 August 2015. This standard was published on 23 September 2015. The following are represented on Committee EL-006: Association of Accredited Certification Bodies Ausgrid Australian Chamber of Commerce and Industry Australian Industry Group Bureau of Steel Manufacturers of Australia Business New Zealand Electrical Contractors Association of New Zealand Engineers Australia National Electrical and Communications Association National Electrical Switchboard Manufacturers Association Rail Industry Safety and Standards Board (RISSB) Keeping standards up to date Standards are living documents which reflect progress in science, technology, and systems. To maintain their currency, all standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current standard, which should include any amendments which may have been published since the standard was purchased. Detailed information about joint Australian/New Zealand standards can be found by visiting the standards webshop in Australia at www.saiglobal.com.au or Standards New Zealand s website at www.standards.co.nz. Alternatively, Standards Australia publishes an annual printed catalogue with full details of all current standards. For more frequent listings or notification of revisions, amendments, and withdrawals, Standards Australia and Standards New Zealand offer a number of update options. For information about these services, users should contact their respective national standards organisation. We also welcome suggestions for improvement in our standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comments to the Chief Executive of either Standards Australia or Standards New Zealand at the address shown on the title page. This standard was issued in draft form for comment as DR AS/NZS IEC 60947.5.6:2015.

AS/NZS IEC 60947.5.6:2015 (IEC 60947-5-6, Ed. 1.0:1999, IDT) Australian/New Zealand Standard Low-voltage switchgear and Part 5.6: Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) Originated as AS/NZS 3947.5.6:2000. Jointly revised and redesignated AS/NZS IEC 60947.5.6:2015. COPYRIGHT Standards Australia Limited/Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in any form or by any means, electronic or mechanical, including photocopying, without the written permission of the publisher, unless otherwise permitted under the Copyright Act 1968 (Australia) or the Copyright Act 1994 (New Zealand). Jointly published by SAI Global Limited under licence from Standards Australia Limited, GPO Box 476, Sydney, NSW 2001 and by Standards New Zealand, Private Bag 2439, Wellington 6140. ISBN (Print) 978-1-77664-082-9 ISBN (PDF) 978-1-77664-083-6

AS/NZS IEC 60947.5.6:2015 2 PREFACE This Standard was prepared by the Joint Standards Australia/Standards New Zealand Committee EL-006, Industrial Switchgear and Controlgear, to supersede AS/NZS 3947.5.6:2000. The objective of this Standard is to provide characteristics, constructional and performance requirements and tests to verify performance for proximity sensors connected for operation by a two-wire connecting cable to the control input of a switching amplifier with a d.c. source. This Standard is identical with, and has been reproduced from, IEC 60947-5-6, Ed. 1.0 (1999), Low-voltage switchgear and, Part 5.6: Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR). As this Standard is reproduced from an International Standard, the following applies: (a) In the source text this International Standard should read this Australian/New Zealand Standard. (b) A full point substitutes for a comma when referring to a decimal marker. References to International Standards should be replaced by references to Australian or Australian/New Zealand Standards, as follows: Reference to International Standard Australian/New Zealand Standard IEC AS/NZS 60079 Electrical apparatus for explosive gas atmospheres 60079 Electrical apparatus for explosive gas atmospheres 60079-11 Part 11: Intrinsic safety i 60079.11 Part 11: Intrinsic safety i AS/NZS IEC 60947 Low-voltage switchgear and 60947 Low-voltage switchgear and 60947-1 Part 1: General rules 60947.1 Part 1: General rules 60947-5-2 Part 5-2: Control circuit devices 60947.5.2 Part 5.2: Control circuit devices and and switching elements Proximity switching elements Proximity switches switches Only normative references that have been adopted as Australian or Australian/New Zealand Standards have been listed.

60947-5-6 IEC:1999 3 AS/NZS IEC 60947.5.6:2015 CONTENTS 3 CONTENTS FOREWORD... 5 Clause 1 Scope...4 2 Normative references...4 3 Definitions...4 4 Classification...6 5 Characteristics...7 5.1 Control input of the switching amplifier...7 5.2 Interaction between proximity sensor and switching amplifier...7 5.3 Continuous characteristic...7 5.4 Discontinuous characteristic...7 5.5 Switching current difference...7 5.6 Line resistance...7 5.7 Insulation resistance...7 6 Product information...8 6.1 Proximity sensors...8 6.2 Switching amplifiers...8 7 Normal service, mounting and transport conditions...9 7.1 Normal service conditions...9 7.2 Connection identification and marking...11 7.3 Conditions during transport and storage...11 7.4 Electromagnetic compatibility (EMC)...11 8 Constructional and performance requirements...11 9 Tests...11 9.1 Switching amplifier...11 9.2 Proximity sensor...12 9.3 Results to be obtained...13 9.4 Verification of the electromagnetic compatibility...14 Page Figure 1 Example of a continuous characteristic of a proximity sensor...10 Figure 2 Example of a discontinuous characteristic of a proximity sensor...10 Figure 3 Control input of the switching amplifier...12 Figure 4 Characteristics of proximity sensor in the high impedance state...13 Figure 5 Characteristics of proximity sensor in the low impedance state...14 Table 1 Classification of proximity switches...6 Table 2 Connection and wiring identification...11

AS/NZS IEC 60947.5.6:2015 4 AUSTRALIAN/NEW ZEALAND STANDARD 60947-5-6 IEC:1999 7 Low-voltage LOW-VOLTAGE switchgear SWITCHGEAR and AND CONTROLGEAR Part 5.6: Part 5-6: Control circuit devices and switching elements Control circuit devices DC interface and switching for proximity elements DC sensors andinterface for proximity switching amplifiers (NAMUR) sensors and switching amplifiers (NAMUR) 1 Scope This International Standard applies to proximity sensors connected for operation by a two-wire connecting cable to the control input of a switching amplifier. The switching amplifier contains a d.c. source to supply the control circuit and is controlled by the variable internal resistance of the proximity sensor. These devices can be used in an explosive atmosphere if they also comply with IEC 60079-11. NOTE These devices have been defined by the German organization Normenausschuß für Meß- und Regelungstechnik (NAMUR) (Office for Standardization of Measurement and Regulation Techniques). 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 60079-11:1999, Electrical apparatus for explosive gas atmospheres Part 11: Intrinsic safety i IEC 60947-1:1999, Low-voltage switchgear and Part 1: General rules IEC 60947-5-2:1999, Low-voltage switchgear and Part 5-2: Control circuit devices and switching elements Proximity switches 3 Definitions For the purpose of this International Standard the following definitions apply. 3.1 proximity sensor device which converts the travel of an influencing body relative to it into an output signal NOTE 1 The proximity sensor is preferably contactless (e.g. inductive, capacitive, magnetic, photoelectric). NOTE 2 The proximity sensor may be operated with or without mechanical contact. 3.2 switching amplifier device which converts the signal from the proximity sensor presented at the control input into a binary output signal which may be produced e.g. by an electromagnetic relay or a semiconductor switching element COPYRIGHT

AS/NZS IEC 60947.5.6:2015 Low-voltage switchgear and - Part 5.6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) This is a free sample only. Purchase the full publication here: https://shop.standards.govt.nz//catalog/60947.5.6%3a2015%28as%7cnzs+iec%29/view Or contact Standards New Zealand using one of the following methods. Freephone: 0800 782 632 (New Zealand) Phone: +64 3 943 4259 Email: enquiries@standards.govt.nz