MODEL 421 NUCLEAR POWER PLANT TRITIUM MONITOR

Similar documents
MODEL 321/421 NUCLEAR POWER PLANT TRITIUM MONITOR

300/400 UNITS - MODULAR CONFIGURATION

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Analog Room Pressure Monitor RPC Series

PORTABLE DEW POINT MONITOR

SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

ph COOLING TOWER CONTROLLER

Specification/ Data Sheet

Using the Model 1500 Portable Chilled Mirror Hygrometer

AS950 REFRIGERATED SAMPLERS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

DGH Series Global Air Treatment

Quality Components as a basis for Quality Equipment

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

I/A Series 716C 1/16 DIN Temperature Controller

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

UDC100 Universal Digital Controller Specifications

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Soft Start Series MP700 Solid State, Reduced Voltage

DIESEL Engine Fire Pump Controllers Features

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

Across-the-Line SERIES MP300 Combined Manual and Automatic

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Oxygen (O2) Single-Point Gas Detection System

Dual Column Dehydrating Breather Manual

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Model 4001 Series Single Channel Controller

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Nuclear Associates

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

V LPM Desiccant Air Dryer Installation and Operation Manual

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

SAM-MAX Refrigerant Monitors

Instructions Model MIR MSHA Approved IR Gas Detector 3.1 7/

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Rosemount Analytical MODEL 755A OXYGEN ANALYZER INSTRUCTION MANUAL U

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Instruction Manual WARNING

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

PumpSaver ISS-105 IS Super Cell Installation Guide

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

AS950 PORTABLE SAMPLERS

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

Two-Channel Gas Controller

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Enclosed Scroll Air Compressor System SES 3-5 HP

Controllers. Instruction Manual WARNING

Area Monitor/Frisker Count Rate Meter Victoreen

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

RQE Series Temperature Controllers

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

Applications and Features

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Model Q45P/R. ph/orp Monitor...

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Model OEM-2 INSTRUCTIONS FOR USE

Oxygen Plant Installation for Paktia Hospital (Gardez City)

GLD-30 Gas Leak Detector

MagnaValve Shot Flow Controller

Release Control Fire Alarm Systems

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Cambridge Engineering, Inc. 24 S-Series Technical Manual

451 Black Forest Road Hull, IA Ph: (712) Fax: (712) TS g/hr Turnkey Ozone Generation System

HEATLESS DESICCANT AIR DRYERS

Model Q45P/R. ph/orp Monitor...

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Waveguide Dehydrators

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Centro-Matic Automated Lubrication Systems System Controls

Transcription:

PLANT "WIDE RANGE" TRITIUM NPPM This tritium monitor is a version of the OTC standard 321/421 series, configured for the special environmental conditions associated with nuclear power plants, especially those of the CANDU type. This monitor can be used for other applications where tritium specific measurements in the presence of other radionuclides are required. Major distinguishing features include the following: Measures tritium or tritium oxide specifically Immune to other radioisotopes, including reactor gases as well as radon Gamma compensated dual chamber design Plate out proof ionization chambers eliminate background zero drift Drift free zero Rugged industrial enclosure Unaffected by variations in temperature or humidity A variety of alarms and controls are available. Optional Remote Displays and Sampling Units can be built to suit different applications. SENSITIVITY - NOISE LEVELS The Model 421 NPPM has been designed to exhibit sensitivities commensurate with safety requirements associated with worker exposure in power plants. Sensitivity limits induced by background noise levels with instruments incorporating 2 liter ionization chambers approach 0.3 μci/m 3. RANGE The Model 421 NPPM is dual range, extending measurement to up to 6 plus decades. MAINTENANCE Except for routine attention the sample line dust filters and preventive maintenance to the sampling pump, the instrument will provide decades of trouble free service. SUPERVISORY SIGNALS Computer compatible outputs are provided to signal operational failure including loss of sample flow, pump failure, electrical failure including that of the electronics, and failure of the ionization chambers. 300/400 UNITS - FIXED CONFIGURATION:PAGE 19

, NPPM VERSION MEASUREMENT Range, typical Display Accuracy Stability and Drift Noise Response Rate two, automatically switch 0.1 10,000 μci/m 3 low range 1.00 200.00 mci/m 3 high range other ranges available 4 1/2 digital panel meter ± 2 % of reading, ± L.S.D., whichever is greater ±1.0 μci/m 3 long term (thirty days), ambient temperature conditions ±1.5 μci/m 3, 1 sigma, with alpha suppression in use three linear electronic time constants approximately 40 seconds for signals up to about 80 μci/m 3 approximately 10 seconds for signals from 80 to 10,000 μci/m 3 approximately 3 seconds for signals above 1.00 mci/m 3 Warm Up Time less than ten minutes ALARM SYSTEMS High Level Malfunction Low Range Level alarm with 4-digit thumb wheel potentiometer preset from 1 9,999 μci/m 3. High Range Level alarm with 3-digit thumb wheel potentiometer preset from 2 200 mci/m 3. Toggle switch selector for High or Low Range Level Set Points. An Alarm condition activates a visual (red LED) an acoustic indicator and fail-safe relay closure. Toggle switch selector for latching or non-latching modes and reset. Acknowledge push button to silence acoustic indicator after alarm is tripped. Failure of any one three conditions will activate a non-latching visual indicator and fail-safe relay closure. One, a dc power supply monitor verifies all internal dc supplies are within specification. Two, verifies that the electrometer cable is connected. Three, sample flow monitored by a delta pressure switch. 300/400 UNITS - FIXED CONFIGURATION:PAGE 20

, NPPM VERSION, continued IONIZATION CHAMBER INTERNALLY MOUNTED Measuring volume: Total wetted volume: Electrodes Pressure Ports 1,200 cm 3 each 2,000 cm 3 each Wire Grid, contamination resistant 0.1 to 2 atmospheres 1/4 stainless steel Swagelok SAMPLE FLOW SYSTEM INTERNALLY MOUNTED Pump Flow Rate Flow meter Dust Filter Connection Low Flow Sensor diaphragm type 115/230 VAC 50/60 Hz 14 LPM maximum @ 0 psia 0-10 LPM adjustable HEPA respirator type 1/4 stainless steel Swagelok tube fittings Differential pressure switch ENVIRONMENTAL Temperature Humidity Air Conditioning -40 C to +65 C storage 0 C to +55 C operating 0-95 % RH Ventilation or air conditioning is not required. PHYSICAL, MAIN CABINET Size up 29.37 [747mm] High x 23.63 [600mm] Wide x 18.62 [473mm] Deep wall mounted NEMA 12 painted steel enclosure with key lockable door 115/230 VAC, 50/60 Hz, 50 W including pump and to 4 remote indicators 186 lbs [84kg] 300/400 UNITS - FIXED CONFIGURATION:PAGE 21

RECYCLING DRYER UNIT Desiccant dual copper tube coaxial columns containing desiccant agent. Columns are equipped with internal heaters for the regeneration of the desiccant Cycling System Motor driven cam timer controls solenoid valves and the heaters for sequential operation of each column Column A In use In use In use Column B 1. heat column 2. purge vapor 3. cool column The sequence of events takes six hours for completion, whereupon the sequence recommences for the opposite column. VISUAL INDICATORS Status Indicator Low Flow Circuit Protection Physical Size Rotary pointer knob indicates different states of the sample/regenerate process for both desiccant columns indicates when purge pump flow is <2 LPM 115/230 V, 50/60 Hz, 1500 Watts Crcuit breaker/power ON/OFF switch 30 [762mm] W x 46.75 [1187.5mm] H x 13.5 [343mm]D wall mounted painted steel enclosure 245 lbs [111 kg] 300/400 UNITS - FIXED CONFIGURATION:PAGE 22

TRITIUM SAMPLING UNIT (OPTIONAL) Pump 115/230 VAC, 50/60 Hz Flow Rate 89 LPM Maximum at 0 psia Flow Meter Dust Filter Pressure Connections Low Flow Sensor Vacuum Sensor 10-100 LPM HEPA respirator type 0.1 2 atmospheres 1/4 stainless steel Swagelok tube fittings differential pressure switch vacuum switch CONTROLS Control Pump Control Sample Control Valve Selection Pushbutton switch for power Maintained pushbutton switch for power to pump maintained pushbutton switch for MAIN/REMOTE control controlled by a rotary switch VISUAL INDICATORS Manifold Low Flow Connections red LED, on when purge pump flow fails or falls below 2 LPM. 1/4 stainless steel Swagelok tube fittings ENVIRONMENTAL Temperature Humidity Air Conditioning -40 C to +65 C Storage 0 C to +50 C Operating 0 95 % RH Ventilation or air conditioning is not required. PHYSICAL Physical Size 23.62 [600mm]Wide x 25.75 [654mm] High x 15.16 [385mm] Deep NEMA 12 Enclosure 120VAC, 60Hz, 1Ph, 15A 101 lbs [46 kg] 300/400 UNITS - FIXED CONFIGURATION:PAGE 23

REMOTE DISPLAY / CONTROL UNIT (OPTIONAL) Control Pump Control ON/OFF toggle switch for power to unit ON/OFF maintained pushbutton switch for power to pump Sample Control Valve Selection MAIN/REMOTE maintained pushbutton switch for control unit selection Valve selection controlled by PLC touch screen VISUAL INDICATORS PLC Touch Screen Displays Tritium Concentration 120VAC, 60Hz, 1Ph, 2A ENVIRONMENTAL Temperature Humidity Air Conditioning -40 C to +65 C Storage 0 C to +50 C Operating 0 95 % RH not required. PHYSICAL Physical Size 23.62 [600mm] Wide x 25.75 [654mm] High x 15.16 [385mm] Deep Excluding Hardware NEMA Rating NEMA 12 120VAC, 60Hz, 1Ph, 2A 66 lbs [30 kg] 300/400 UNITS - FIXED CONFIGURATION:PAGE 24