CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Similar documents
CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

HEALTHY CLIMATE HUMIDIFIER

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

Owner s Manual. Humidifiers. For Models 350, 360, 400, 400M, 500, 500M, 600, 600M, 700 & 700M

Owner s Manual For Models 400, 500, 600 & 700

Owner s Manual. For Models 350, 360, 400A, 500A, 500M, 600A, 600M, 700A & 700M. Includes Safety & Operating Instructions and Warranty Information

READ AND SAVE THESE INSTRUCTIONS AUTOMATIC HUMIDIFIER. The Best Cure For Dryness OWNER S MANUAL FOR MODELS 448, 558, 568, 600, & 700

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS. The Best Cure For Dryness OWNER S MANUAL

OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS MODELS 4000, 5000, 6000 & 7000 HUMIDIFIERS. Includes Safety, Operating and Maintenance Instructions

Operating Instructions

Residential Steam Humidifier

HE360 Humidifier Installation Kit

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

HE220, HE260 Humidifier Installation Kit

HE360A,B Powered Flow-Through Humidifier

HE360 Powered Flow-Through Humidifier

HE365A,B Powered Flow-Through Humidifier with

Humidifiers Dealer Parts List Model 400/400M Humidifiers

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

HE120, HE160 Humidifier Installation Kit

FLOW-THROUGH FURNACE HUMIDIFIER

INSTALLATION INSTRUCTIONS

HE420A Steam Power Humidifier

Installation. Leveling

MODEL HUM HUMIDIFIERS

CellarMate. The Key to Wine Cellar Climate Control. Humidifier. Installation, Operation, and Maintenance Manual

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

Humidification. Facts For Total Indoor Air Comfort

HE365A,B Powered Flow-Through Humidifier

G-100ES Duct Mount Humidifier

Installation Instructions

FLOW-THROUGH FURNACE HUMIDIFIER

INSTALLATION INSTRUCTIONS

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

Safety, Installation, and Operation Manual

HE365A,B Powered Flow-ThroughHumidifier with

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

Continue to next pages for Template instructions, Owners Guide, Humidistat Instructions.

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

TECHNICAL INSTRUCTIONS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

INSTALLATION. Glass Panel Doors (select models) CAUTION

Humidifiers Dealer Parts List

BF5000NT BF5000 EF2604 SF2603 DF2603

DS 2001 REVISED Humidifier Assembly and Instruction Manual

G-100ES Duct Mount Humidifier

Duct Mounted Atomizing Humidifier. Table of Contents

USER S INFORMATION MANUAL

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

HE365A,B Powered Flow-ThroughHumidifier with JI

G61MPV SERIES GAS FURNACE WARNING

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

T4398A,B Precision Electric Heating Thermostat

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

SuperKlean Washdown Products

PARTS AND SERVICE MANUAL FOR THE 23 COMPACT FIREPLACE

Installation Instructions Owner s Manual

INSTALLATION INSTRUCTIONS

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes

Summer Breeze Heater Service Manual

USER S INFORMATION MANUAL

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

ComfortSTEAM TM. Humidification System

ML180UH SERIES GAS FURNACE WARNING WARNING

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

PARTS & SERVICE MANUAL

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

ROOM AIR CONDITIONER OWNER'S MANUAL

Installation Instructions

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

INSTALLATION INSTRUCTIONS

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Refrigerator. Installation Guide. Free Standing Appliance

EL195UHE SERIES GAS FURNACE WARNING WARNING

CUSTOMER SERVICE. Toll-free:

USER S INFORMATION MANUAL

COMPACT DRYER GDZ5-1 Training Presentation

Installation & Operating Guide

Duct Mount Rotating Drum Humidifier

USER S INFORMATION MANUAL

DT/DTH/DR/DRH MERIT SERIES

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

EL195DFE SERIES GAS FURNACE WARNING

WARNING FIRE OR EXPLOSION HAZARD.

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

User s Information and Installation Instructions

Automatic Humidifiers

Duct Mount Atomizing Humidifier

MEMOIRS VITREOUS CHINA TOILETS

Transcription:

IAQ HUMIDIFIERS Litho U.S.A. 2007 Dallas, Texas, USA 505,289M 09/2008 Supersedes 08/2007 KAZ # C.6046 HCWB2 & HCWP2 SERIES USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS Table Of Contents Introduction.................................... 1 Humidifier Operation............................ 1 Operating Instructions Manual Humidistat....... 2 Operating Instructions Universal Humidistat...... 2 Operating Instructions (Automatic Mode).......... 3 Operating Instructions (Manual Mode).......... 3 Water Characteristics......................... 4 Summer Shutdown........................... 4 Periodic Preventative Maintenance............ 4 HCWB2 Required Maintenance................ 5 HCWP2 Required Maintenance................ 6 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Introduction This manual includes information that will familiarize you with your humidifier. It also details routine maintenance required to keep the humidifier working properly. Electric shock hazard. Can cause injury or death. Disconnect all electrical power supplies before servicing. Shut off water into any water supply line.! CAUTION Risk of Equipment Damage. After humidifier installation is completed, turn water supply back on. Humidifier Operation Your new humidifier works with your central heating system to increase indoor humidity as necessary. The humidifier is typically wired to operate when the indoor blower motor is on during the heating mode and the indoor relative humidity (RH) is below the selected comfort level. During a call for humidity, water flows into the EquaFlo distribution tray, where it is distributed evenly across the width of the pan. The humidifier pad is saturated with water. Dry hot air moves through the pad where evaporation takes place. The humidified air carries moisture in vapor form throughout the home.! CAUTION Risk of Equipment Damage. Do not use the saddle valve to regulate water flow. The valve is designed to be completely opened or closed. Page 1

During humidifier operation, a steady stream of water flows to the drain. This water flushes away minerals and other particles of solid residue. Some particles are trapped by the humidifier pad. This eliminates the white dust" which is often mentioned in complaints about other systems. The water flow and drain design also eliminate problems caused by stagnant water. The humidifier pad must be in good condition to assure trouble free performance. It should be changed at least annually. All humidifier parts that come in contact with water are designed not to rust or corrode. Neither heat nor water will affect the humidifier components under normal operating conditions. HCWB2 12 and 17 and HCWP2 18 Operating Instructions It is important to maintain proper indoor relative humidity (RH). When the indoor RH is too low, the dry air can cause wood furniture to dry and crack. Low humidity can also lead to dry, cracked skin, as well as nose bleeds. When the indoor RH is too high, the extra moisture may cause condensation on the inside of windows (fogging or frost on windows). Water may puddle on window sills and floors. Recommended indoor relative humidity levels are given in table 1 and on the front of the humidistat. For example, when the outside temperature is 20 F, the recommended indoor relative humidity (RH) is 35%. HCWB2 12 and 17 and HCWP2 18 humidifiers are controlled by a manual humidistat, which is installed either in the living area or on the return air plenum. A manual humidistat is used to set desired indoor RH. The humidistat controls the humidifier so that it introduces humidity corresponding to the humidistat control knob setting. KNOB MANUAL HUMIDISTAT FIGURE 1 TABLE 1 Relative Humidity (RH) Settings Outside Temperature Recommended RH (Fahrenheit) +40 45% +30 40% +20 35% +10 30% 0 25% 10 20% 20 15% To check the humidifier operation, make sure that the water saddle valve is open, there is power to the humidifier and the furnace/air handler blower is running. Turn the humidistat control knob to the OFF position. Then, slowly turn the knob in the other direction, until you hear a click from either inside of the humidistat or from the humidifier solenoid valve. (If the RH in the immediate vicinity of the humidistat is more than 45%, the humidfier will not turn on.) After the humidifier has operated for several minutes and water is coming out at the drain, reduce the humidistat setting. Turn the knob to a point below the click point. The humidifier should automatically shut off. Now, set the humidistat dial at the recommended inside RH, depending on the outside temperature. It is important to watch for signs that the indoor relative humidity (RH) level. If the level is too low or too high, the humidistat control setting should be adjusted accordingly. You should anticipate changes in the outdoor temperature, so that you can adjust the setpoint prior to a drop in the outside temperature. It takes time for the humidifier to adjust the indoor relative humidity. Be sure to keep fireplace dampers closed when not in use. Chimneys provide an excellent escape route for heat, as well as humidity. HCWB2 12A and 17A and HCWP2 18A Operating Instructions HCWB2 12A and 17A and HCWP2 18A humidifiers are controlled by a universal humidifier control, which offers two modes of operation: automatic and manual. When installed in the automatic mode the system benefits you in the following ways: 1 The control automatically adjusts your home s RH based on the outdoor temperature. 2 The control eliminates the need to manually adjust the control. 3 The universal humidistat precisely controls the RH in your home, ensuring maximum comfort for a greater percentage of time. The universal humidistat also prevents excess condensation or low humidity in the home. 4 The universal humidistat eliminates the need to turn the dial setting to OFF during the summer season. Page 2

Automatic Mode Immediately after installation, the universal humidistat must be set to match your home s condition. Follow these steps to adjust the automatic humidifier control. See figure 2. UNIVERSAL HUMIDISTAT 6 NORMAL 5 4 HUMIDIFIER 3 2 7 TEST OFF 1 FIGURE 2 KNOB PAD REPLACEMENT TIMER RESET BUTTON 1 Turn the knob to setting 5, which is within the normal range. During the next 24 to 48 hours, it may be necessary to adjust the dial for more or less humidity, depending on your personal comfort and the home s requirements. See table 2. TABLE 2 Operation Guide Condition Solution Reduce the setting on the control Condensation on windows. dial by one increment at a time. Lack of humidity. Humidifier does not operate. (solenoid does not click" when control is moved to TEST position.) Humidifier won t shut off Test Mode Increase the setting on the control dial by one increment at a time. Make sure power is available to the solenoid valve. Turn dial to TEST. Make certain furnace blower is operating and furnace is calling for heat. If unit still does not operate, consult a heating contractor. Turn dial to OFF. If unit continues to operate, consult a heating contractor. System operation is checked by setting the knob to TEST. Make certain that the furnace blower is operating and furnace is calling for heat. Humidifier will operate for one minute. 2 During the coldest portion of the first heating season, minor adjustments may be necessary, depending on the home s construction. See table 2. The RH in your home will be accurately controlled to meet your needs and should not need further adjustment during future heating seasons. Make note of the dial setting in the event the knob gets moved. Your humidifier is part of a system that will accurately maintain the RH in your home. For every 1 F change in outdoor temperature, the universal humidistat will automatically adjust the indoor relative humidity by 0.5% RH. If you would like to determine the RH in your home, follow these steps: 1 Determine the outdoor temperature. 2 Activate the furnace blower by setting your thermostat fan switch to the ON position, or by setting your thermostat to a higher temperature. 3 Turn the control dial setting to the OFF position. Then, slowly turn the dial clockwise until you hear the solenoid valve click on. Slowly turn the dial counterclockwise until you hear the solenoid valve click off. At this point, make note of the dial setting. 4 Locate your dial setting on table 3. Follow the dial setting to the right until it intersects with the current outdoor temperature. This is the RH in your home under existing conditions. 5 Return the thermostat and control to their original settings. TABLE 3 Percentage Relative Humidity (RH) Outdoor Temperature ( F) Dial Setting 10 0 10 20 30 40 1 10 10 10 15 20 25 2 10 10 15 20 25 30 3 10 15 20 25 30 35 4 15 20 25 30 35 40 5 20 25 30 35 40 45 6 25 30 35 40 45 45 7 30 35 40 45 45 45 As an example, if the outdoor temperature is 20 F and, following step 3, the humidifier turns off at 5"on the dial range, then the RH in your home is 35%. The universal humidistat will accurately control the humidity in your home to a maximum of 45% RH and a minimum of 10% RH. The values of outdoor temperature and dial settings may fall in between or outside of the listed values in table 3. In these cases, you will be able to approximate your home s actual indoor RH. Manual Mode If an outdoor temperature sensor has not been installed with your universal humidistat, the control is installed in the cold air return and is set for manual mode operation. In this case, it is important to keep the humidistat setting at the recommended level in order to avoid excessive indoor RH. This will prevent the formation of condensation on inside windows (fogging or frost on windows). For example, with an outside temperature of 20ºF the correct setting will be 35% RH. If the temperature is expected to fall to 0ºF that evening, then adjust the setting to provide 25% RH several hours prior to the temperature change. UNIVERSAL HUMIDISTAT IN MANUAL MODE FIGURE 3 KNOB PAD REPLACEMENT TIMER RESET BUTTON Page 3

The recommended settings noted on the sticker on the front of the control and in table 1 are based on years of research and experience. For example, a winter time indoor RH of 50% may be considered by you to be ideal for your personal comfort; however, this setting may result in damage to your home. Observance of the recommended RH levels on your humidistat, therefore, is an important safeguard. These settings represent a compromise between RH levels that are desirable for comfort reasons and humidity levels, which will avoid condensation on your windows. The humidistat can be used to accurately determine the RH in your home during the winter. With the furnace blower operating at the heating speed, turn the dial to the lowest setting, then reverse the dial direction slowly until you hear the solenoid valve click on. At this point, read the RH on the dial. This will be very close to the actual RH in your home. To check the humidifier operation, set the knob to TEST. Make sure that the water saddle valve is open and that there is electricity to the unit. Generally, the furnace blower motor must be operating for the humidifier to function. After the humidifier has operated for one minute and water is entering the unit and coming out at the drain, reduce the humidistat setting to the recommended inside RH, depending on the outside temperature. Do not leave the control in the test mode. The humidifier will not operate properly in the test mode. Anticipate a drop in the outside temperature and lower the setting several hours before the drop in outdoor temperature occurs. Water Characteristics Your humidifier will operate effectively using either hard or mechanically softened water. Any type of water (hard, soft, hot, or cold) is acceptable for use with the HCWB2 or HCWP2 humidifiers. Hot supply water (140 F maximum) is recommended for all heat pump applications. The use of hot supply water will also increase the unit s capacity. Risk of Scalding. Water temperature over 125 F can cause severe burns and can scald instantly. Shut off the hot water into any hot water supply line. Summer Shutdown Models equipped with a manual humidistat (figure 1) Turn the humidistat control knob to the OFF position. Models equipped with a universal humidistat in the manual mode (figure 3) Turn the humidistat control knob to the OFF position. HCWB2 bypass models (figure 5) Switch the damper handle to one of the SUMMER settings to close the damper. Periodic Preventative Maintenance NOTE Annual inspection and maintenance is important for efficient and safe operation of your humidifier. Call your Lennox dealer for humidifier service, maintenance inspection and replacement parts. The humidifier pad should be replaced at least annually. Your humidifier is equipped with an in line water strainer and orifice as shown. These parts should be inspected and cleaned annually to assure continued proper unit performance. Inspect more often if white dust" is evident. SOLENOID VALVE COMPONENTS INLINE STRAINER FIGURE 4 OUTLET COMPRESSION NUT ORIFICE (inside tubing) SOLENOID VALVE INLET INLET COMPRESSION NUT 1 Disconnect electrical power to the furnace and shut off water supply. Make note of humidistat setting and turn humidistat dial to OFF position. 2 Disconnect the water line at the inlet compression nut. NOTE Always use the double wrench technique to connect or disconnect humidifier water lines. 3 Use a small nail or wire to remove the in line strainer from inside the inlet side of the valve. 4 Flush the in line strainer clean or replace with a new strainer. 5 Reinstall the in line strainer and reconnect the inlet water line. Take care. Do not bend or misalign the valve bracket and tubing. 6 Disconnect the water line at the outlet compression nut. 7 Check the hole in the plastic orifice to make sure the small opening is unplugged. Do not try to remove the orifice from the copper tube. 8 Reinstall the copper tube and reconnect the outlet water line. 9 HCWB2 Models Check to ensure that the copper tube is inside the plastic sleeve. Page 4

HCWB2 REQUIRED MAINTENANCE Refer to figure 5 for parts identification when reviewing the following procedure. Bold text indicates components that are identified in the illustration. Electric shock hazard. Can cause injury or death. Disconnect all electrical power supplies before servicing. Shut off water into any water supply line. 1 Make sure the main power to furnace is disconnected. 2 Make sure the humidistat is in the OFF position. 3 Make sure the water supply is turned off. 4 Slide the latch to release the front cover. Swing the cover open, then lift it away from the assembly. 5 Turn the damper handle to one of the SUMMER" positions. Grasp the tabs on the pad assembly frame and lift the assembly out of the humidifier base. NOTE It may be easier to remove the frame by pulling on the tabs one at a time. 6 Unsnap the pad assembly frame from the sides of the distribution tray. Remove the distribution tray from the pad assembly frame. Remove the tray cover by pulling it straight off of the distribution tray. Lightly scrape off any mineral deposits from the surface of the distribution tray. 7 Slide the humidifier pad out of the frame. Twist and flex the frame to loosen the calcium deposits on the frame or use a putty knife to clean the frame. Replace the humidifier pad annually or more frequently if necessary. Slide the pad into the frame with the black mark facing up. Snap the tray cover onto the distribution tray. Snap the distribution tray back into place. 8 Position the pad assembly frame so that the tabs are pointing outward. Align the drain extension on the pad assembly with the drain spud in the humidifier base. Reinsert the humidifier pad assembly frame in the base. Push the pad assembly frame in at the top until it snaps into place. Replace the front cover. Turn the damper handle to the WINTER" position. 9 Remove the drain hose from the bottom of the humidifier. Bend and flex the hose to loosen any internal calcium deposits. Flush the hose with water under pressure and slip it back onto the drain spud. The drain hose should have a constant downward slope and must not be flattened or blocked. 10 Turn on water supply. 11 Check humidifier operation: Manual Humidistat Adjust humidistat to highest setting and make sure the furnace blower is operating. Humidifier will operate if RH is less than 50%. Check the humidifier for leaks during operation. Adjust, if necessary. Universal Humidistat Check system operation by setting the knob to TEST position. With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. Press the RESET button on the side of the control to reset the Change Humidifier Pad" indicator. Check the humidifier for leaks during operation. Adjust, if necessary. 12 Set manual humidistat or universal humidistat to its original position. TRAY COVER HCWB2 Bypass Humidifier Parts Identification (Right side discharge orientation shown) DISTRIBUTION TRAY TABS SOLENOID VALVE FRONT COVER DAMPER DAMPER HANDLE WINTER/SUMMER ADJUSTMENT LEVER (Close damper during summer operation) HUMIDIFIER BASE LATCH HUMIDIFIER PAD ASSEMBLY FRAME (with frame tabs pointing outward and black mark facing up) FIGURE 5 DRAIN SPUD DRAIN HOSE Page 5

HCWP2 REQUIRED MAINTENANCE Refer to figure 6 for parts identification when reviewing the following procedure. Bold text indicates components that are identified in the illustration. Electric shock hazard. Can cause injury or death. Disconnect all electrical power supplies before servicing. Shut off water into any water supply line. 1 Make sure the main power to furnace is disconnected. 2 Make sure the humidistat is in the OFF position. 3 Disconnect electrical power to the humidifier and make sure that the water supply is turned off. 4 Pull the tab to release the control harness. Disconnect the harness. 5 Release the front cover latch at the bottom of the humidifier assembly. Swing the cover open, then lift it away from the assembly. 6 Grasp the tabs on the pad assembly frame and lift the assembly out of the humidifier base. NOTE It may be easier to remove the frame by pulling on the tabs one at a time. 7 Unsnap the pad assembly frame from the sides of the distribution tray. Remove the distribution tray from the pad assembly frame. Remove the tray cover by pulling it straight off of the distribution tray. Lightly scrape off any mineral deposits from the surface of the distribution tray. 8 Slide the humidifier pad out of the frame. Twist and flex the frame to loosen the calcium deposits on the frame or use a putty knife to clean the frame. Replace the humidifier pad annually or more frequently if necessary. Slide the pad into the frame with the black mark facing up. Snap the tray cover onto the distribution tray. Snap the distribution tray back into place. 9 Position the pad assembly frame so that the tabs are pointing outward. Align the drain extension on the pad assembly with the drain spud in the humidifier base. Reinsert the pad assembly frame in the base. Push the pad assembly frame in at the top until it snaps into place. 10 Remove the drain hose from the bottom of the humidifier. Bend and flex the hose to loosen the internal calcium deposits. Flush the hose with water under pressure and slip it back onto the drain spud. The drain hose should have a constant downward slope and must not be flattened or blocked. 11 Reinstall the front cover by hooking at the top of base and latching at the bottom. 12 Reconnect the control harness. Make sure that the plug snaps into place. 13 Reconnect electrical power and turn on water supply. 14 Check humidifier operation: Manual Humidistat Adjust humidistat to highest setting and make sure the furnace blower is operating. Check the humidifier for leaks during operation. Adjust, if necessary. Universal Humidistat Check system operation by setting the knob to TEST. With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. Press the RESET button on the side of the control to reset the Change Humidifier Pad" indicator. Check the humidifier for leaks during operation. Adjust, if necessary. 15 Set manual humidistat or universal humidistat to its original position. TRAY COVER PAD ASSEMBLY FRAME HCWP2 Humidifier Parts Identification SOLENOID VALVE DISTRIBUTION TRAY FRONT COVER TABS BASE HUMIDIFIER PAD (Black mark facing up) DRAIN HOSE DRAIN SPUD LATCH HARNESS TAB POWER CORD FIGURE 6 Page 6