Read and save these instructions

Similar documents
Read and save these instructions

Read and save these instructions

Split Wall-Recessed Cooling System Operation Care Installation Manual

Read and save these instructions

Read and save these instructions

Read and save these instructions

Read and save these instructions

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD

Read and save these instructions

Split Floor-Mounted Cooling System Operation Care Installation Manual

Read and save these instructions

WM-4510HZD Installation Instructions

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Control the Elements. Owner s Manual 3200VSi / 3200VSx / 4200VSi / 4200VSx V5.15

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Control the Elements. 220V / 1PH / 50Hz

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T20 Model

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Dixell Installing and Operating Instructions release 7.0

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

VINOTEMP INTERNATIONAL SOUTH SUSANA ROAD RANCHO DOMINGUEZ,CA (800) FAX (310) WINEMATE COOLING SYSTEMS

T-Series Air Conditioner T53 Model

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

5) Do not start or stop the unit by inserting or pulling out the power plug.

Portable Dehumidifier

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Beverage Air IMPORTANT

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Glass Door Refrigerators

Superdryer Dehumidifiers

Portable Dehumidifier with Internal Pump

INSTALLATION AND OPERATING MANUAL

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

INSTALLATION AND OPERATING MANUAL

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

M52 3-Phase INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

Model 1870F Dehumidifier Installation and Operating Manual

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

12,000 BTU Evaporative Portable Air Conditioner

Operator s Manual. IP-100 Immersion Probe Cooler

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

GL-DEH Series Portable Dehumidifier Operating Instructions

InstructIon Manual KrEs EQuIPMEnt stands

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

A PROUD HERITAGE OF EXPERIENCE & QUALITY. SINGLE- Zone Wine COOLER EL-33WCST

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ControltheElements. Owner smanual. FineFurnitureforFineWines

Quest Dry 105, 155, and 205 Dual

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

2.4 Cu. Ft. Compact Refrigerator

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Split Refrigeration Systems

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

ProAir CR23 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

INSTRUCTIONS! DO NOT DISCARD!

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Instruction Manual Item No.: V~, 60Hz

RPI Industries, Inc.

Glass Door Undercounter and Countertop Freezers

MINITOP Refrigerated Self-Service Display underneath

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

Operating Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

RPI Industries, Inc.

Quest 105, Dry155, and 205 Dual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

SLIDER CASEMENT AIR CONDITIONER

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

OPERATING INSTRUCTIONS

EXTREME SERIES OWNER S MANUAL. Extreme 3500 ti Extreme 5000 ti Extreme 8000 ti. The Coolest Thing In Wine Storage

OMNITOP Refrigerated Display with Ventilated Cooling

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

ULTIMATE SERIES OWNER S MANUAL. Ultimate 3300 Ultimate 4400 Ultimate 8800

Model 1850F Dehumidifier Installation and Operating Manual

Transcription:

www.winemate.com Customizable Wine Cooling System WM-4510HZD WM-6510HZD WM-8510HZD Installation, Use & Care Manual www.vinotemp.com Read and save these instructions

Important Safety Information NOTES: Do not plug in until 24 hours after delivery. Do not use a ground fault interrupter (GFI). Do not use an electrical extension cord. A dedicated 20 AMP circuit is required for WM-4510HZD and 30 AMP is required for WM-6510HZD & WM-8510HZD. - 1 -

Table of Contents Cellar Construction....3 Features & Specifications....4 Control Panel..... 7 Temperature & Humidity.. 8 Installation Instructions.. 12 Care Guide.24 Troubleshooting...25 Electrical Diagrams... 28 Customer Support 36 Warranty.37-2 -

Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R13 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall be installed on the warm side of the insulation. All joints, door frames, electrical outlets or switches and any pipes or vents that go through the cellar shall be sealed to prevent air and moisture leakage into the cellar. Concrete, rock, and brick are not insulation or vapor barriers. Doors shall be of a minimum size, insulated to at least R13 and tightly sealed with high quality weather stripping. Be sure to seal the bottom of the door and fill gap between the door s frame and wall before installing the cap molding. In order to maintain 55 F in the wine cellar, the ambient temperature surrounding the enclosure shall not exceed the temperature of the cellar by more than 25 F. No cellar wall shall receive direct sun or strong wind. Lighting shall be of low wattage, with a timer to insure lights are not left on when the cellar is not occupied. The cooling system will not be able to maintain the proper temperature if fresh moisture-laden air is constantly being introduced to the cellar. Symptoms of this condition are; cooling unit runs all the time with only a slight reduction in temperature and/or water overflows from the unit. Because of the temperature difference between the inside and outside, very small cracks can allow large amounts of outside air to enter into the cellar. Please be aware that moisture can pass through solid concrete, paint and wood. Often a newly constructed cellar contains fresh wood, paint, concrete and other building materials. These materials contain large amounts of moisture. When placed into operation in this type of environment, the system will work harder to remove this extra moisture resulting in increased run time. - 3 -

Purpose of the cooling units Features and Specifications WM-4510~8510HZD cooling units are designed and used to provide a stable temperature between 50~65 F for a properly insulated and sized space. The refrigerated space will maintain humidity within the range of 50~70% RH. These temperature and humidity ranges like in natural caves are optimized for long term storage of wine. Specialty of design The unit is self-contained and all-in-one ready for use. No copper tubing and drain line are required. Patented control programming can adjust the humidity without an external humidifier. Both curved supply grille and front panel bring you dynamic style. Backward-curved impeller fans can duct the supply air and exhaust air each 50 ft in total. Flexibility of installation Adjustable speed evaporator fan allows for flexible installations: standard through-wall, through-wall with ductworks, in-cellar with ductworks and remote-mount with ductworks. Quiet and high speed condenser exhaust fan selection makes it work at both normal and extremely high ambient temperatures. Availability of options Crankcase heater protects the compressor from slugging damage when the ambient temperature falls below 50 F. Low cellar temperature activated cellar heater outlet for an electric heater can be used in extreme low temperature condition to protect your wine from freezing. Low and high cellar temperature activated phone notification allows your expensive wine protected all the time. An independent humidifier can be hooked up to maintain the proper humidity as the customer requires in extremely dry conditions. Reusable condenser air filter keeps the condenser clean and maintains the cooling unit running efficiently. Optional left or right towards supply grille, top exhaust, side or rear power cord can meet your customized air supply and installation requirements. The specifications and dimensions are listed as follows: - 4 -

MODEL NO CELLAR SIZE (cu ft) AIR FLOW (cfm) AIR FILTER (, nominal) DUCT ( ) WM-4510HZD 1000 300 11.5x13.5x1 8 WM-6510HZD 1500 500 13.5x14.5x1 10 WM-8510HZD 2000 500 13.5x14.5x1 10 DIMENSIONS ( ) WxW1xD xd1xd2xh 14.375x0.25x21.5 x1.25x1x20 17.125x0.25x28.375 x1.25x1x22.125 17.125x0.25x28.375 x1.25x1x22.125 ELECTRICAL RATING WEIGHT (lb) 115V/60Hz/8A 95 115V/60Hz/14A 140 115V/60Hz/16A 140 NOTES: See the voltage, frequency and current specified on the label at the cooling unit. The rated capacity is determined under the cellar and ambient temperatures of 55 F and 75 F with R13 interior and R19 exterior insulations. Any lower cellar temperature, higher ambient temperature and less insulation will cause reducing capacity and may not maintain 55 F. The ambient temperatures shall not be higher than 100 F or lower than 50 F in order to operate properly. Fig. 1.2 Dimensions - 5 -

NOTE: WM-4510HZD is 14.25 wide, WM-6510HZD & 8510HZD is 17 wide without the front cover. Fig. 1.2 Feature descriptions Fig. 1.3 Exterior wall grille - 6 -

Control Panel 1. Evaporator fan speed control Fig. 2.1 Control panel Turn the knob clockwise to the lowest speed position for non-duct installations; turn counter-clockwise to achieve required air flow CFM for the duct installations. 2. Humidifier outlet Plug in your own independent humidifier in the extremely dry conditions. 3. Cellar heater outlet (option) Plug in your own forced-air electric heater to protect your wine from freezing. The heater will be turned on when the cellar temperature is below the preset low cellar temperature. 4. Alarm call connector (option) Connect the automatic dialer and then plug the provided phone line into your home phone jack. A speech notice will be sent to your phones when the cellar temperature is out of the range. 5. Crankcase heater with fan cycling switch (option) If the ambient temperature falls below 50 F, switch on the heater. 6. High condenser fan switch If the ambient temperature rises above 90 F or ducts are installed, switch on the high condenser fan. - 7 -

Temperature and Humidity 1. The controller 1) Keys Fig. 3.1 TEMPERATURE CONTROLLER SET: To display set-point; in programming mode it selects a parameter or confirms an operation. : To start a manual defrost. : To see the maximum stored temperature; in programming mode it browses the parameter codes or increases the displayed value. : To see the minimum stored temperature; in programming mode it browses the parameter codes or decreases the displayed value. : To turn on/off the power to the unit. + : To lock/unlock the keypad. SET+ : To enter in the programming mode. SET+ : To return to the temperature display. 2) Lock and unlock the keys To lock the keys, press up + down keys + until POF is displayed; to unlock the keys, press up + down keys + until PON is displayed. 3) Display During normal operating conditions, the display shows the value measured by the air temperature probe. In case of active alarm, the temperature flashes alternately to the code alarm. The LED functions are listed as follows. LED MODE FUNCTION ON Compressor enabled Flashing Anti-short cycle enabled ON Defrost cycle enabled ON Fan enabled Flashing Fan delay after defrost enabled ON Alarm occurring ON Temperature measuring unit Flashing Programming mode - 8 -

4) Alarm Signals The alarm codes are described as follows. MESSAGE CAUSE FUNCTION P1 Temperature probe faulty Compressor switching to Con and CoF HA High temperature alarm Probe temperature ALU higher than the setting temperature; Outputs unchanged LA Low temperature alarm Probe temperature ALL lower than the setting temperature; Outputs unchanged CA External alarm All outputs off Probe alarms P1, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms HA, LA automatically stops as soon as the temperature returns to normal value. Alarm CA (with i1f=pal) recovers only by switching off and on the instrument. 2. Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature. Allow 24 hours to stabilize the temperature for each new temperature setting operation 3. How to see temperature set-point 1) Press and immediately release the SET key, the display will show the set-point value. 2) Press again and immediately release the SET key to display the probe value. 4. How to change the set-point 1) Press and hold the SET key until the C or F LED starts flashing and the set-point is displayed. 2) Press the up/down keys / to change the set-point value within 10 sec. 3) Press the SET key again to store the new set-point value. NOTE: The unit turns on at set-point Set plus regulation differential Hy after antishort cycle AC has elapsed; the unit turns off at set-point Set. 5. Manual Defrost Press and hold the defrost on. key until defrost starts. The defrost indicator will be - 9 -

6. Parameter Programming 1) Press and hold the SET + keys until the C or F LED starts flashing, then release the keys. 2) Press and hold again the SET + keys until the Pr2 label is displayed, then release the keys. The first parameter Hy will be displayed. 3) Press up/down keys / to scroll to the required parameter within 10 sec. 4) Press the SET key to display its value. 5) Use up/down keys to change its value within 10 sec. 6) Press SET to store the new value and the display will flash 3 times. 7) To exit: Press SET + or wait 15sec without pressing a key. PARAMETER DESCRIPTION DEFAULT VALUE Set set-point ( ) 55 Hy temperature regulation differential ( ) 4 AC anti-short cycle delay (min) 10 Con compress on with probe faulty (min) 20 CoF compress off with probe faulty (min) 20 CF temperature unit ( F/ C) F: Fahrenheit res display resolution in: integer dly temperature display delay (min) 1 ot probe calibration ( ) 0 LS minimum set-point ( ) 50 US maximum set-point ( ) 65 idf defrost cycle interval time (hour) 12 MdF defrost cycle endurance time (min) 30 ALC temperature alarm type re: relative to set-point ALU high temperature alarm ( ) 10 ALL low temperature alarm ( ) 10 AFH alarm recovery differential ( ) 5 ALd temperature alarm delay (min) 60 dao temperature alarm delay on startup (hr) 23 SAA heater set-point ( ) 40 SHy heater regulation differential ( ) 4 FSU fan action Std FnC fan operating mode C-n: on with compressor & off during defrost C-y: on with compressor & on during defrost O-n: on all the time & off during defrost O-y: on all the time & on during defrost Fon fan on with compressor off (min) 0 FoF fan off with compressor off (min) 15 NOTE: Depending on the controller, not all parameters are used. - 10 -

7. How to calibrate the air probe If the actual cellar temperature differs from the setting temperature, set parameter ot = actual cellar temperature minus set-point. 8. How to adjust defrost cycle In case there is excessive frost, the parameters FnC = C-y, idf = 4 and MdF = 20 can be used to avoid frost. 9. How to adjust the humidity The parameter Fon is used to adjust the humidity in the wine cellar. Higher Fon results in higher relative humidity. Use a separate hygrometer to monitor the humidity. 10. How to set alarm call 1) Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the set-point Set. 2) In order to test the call function, set parameters Ald = 0 and dao = 0. After testing, set Ald = 60 and dao = 23. 11. How to set low cellar temperature heater The heater turns on at SAA minus Shy; the heater turns off at SAA. NOTES: Use a forced air heater to warm up the wine cellar. If there is a thermostat on the heater, bypass it or set the thermostat at the highest level. If the heater runs more than 10 A current, use a 120VAC coil contactor. - 11 -

Installation Instructions NOTE: Mounting brackets, screws, gaskets and other seal materials are not included. Filter adapter, air filter, rear exhaust grille, duct hoods and insulated ducts are sold separately. 1. General Instructions Fig. 4.1 Cooling Unit Installation - 12 -

1) The cooling unit produces cooling supplied into the cellar, meanwhile it also generates heat that must be exhausted outside the cellar. So the cold-air supply and cellar-air return side must be separated from the hot-air exhaust and ambient-air intake side. Through-wall or through-duct installations can separate these two sides. 2) Furthermore, the condenser of cooling unit must intake adequate fresh ambient-air to work properly. The ambient-air intake and hot-air exhaust must not be short-circulated. Both of them must remain unobstructed 36 clearance all around. The area into which the hot air is exhausted must be well ventilated. If it is not, heat generated by the unit will build up and the unit may not operate properly. 3) Additionally, cold-air supply from the front grille must remain unobstructed 36 clearance. 4) The ambient temperatures shall not be above and below what are specified. 5) If the intake and exhaust are located outdoor, protection guards must be installed. 6) Secure the ducts with conduits to the walls and make sure they are not curled, twisted, bent and clogged. 2. Standard through-wall installation (Fig 4.2, 4.3, 4.4 & 4.5) It is the standard installation when the cooling unit can exhaust the hot air to an adjacent space. 1) The cooling unit shall be mounted near the ceiling with equal distance from each side of the cellar. 2) Cut a rectangular opening between two wall studs. The dimensions of the opening shall be 1/4 larger than the width and height of the cooling unit; if top exhaust installation, cut another rectangular opening at the top of the cellar to the length and width of the top exhaust. 3) Construct a shelf as shown. The shelf must be capable of supporting the weight of the cooling unit and preventing it from moving. 4) Place the cooling unit on the shelf with the back of the unit flush with the outside of the wall. 5) Seal the clearance between the cooling unit and opening with a high quality weather stripping, polyurethane spray foam, or foam tape. Cover the seal with molding and attach the molding to the wall not the unit. If it is top exhaust installation, place more gaskets along the top exhaust at the top of the cooling unit. 6) Install the wall grille on the cellar exterior wall or install a rear exhaust grille and an air filter at the rear of the cooling unit. 7) Plug the unit into a properly grounded and dedicated outlet of adequate capacity. 8) Turn the evaporator fan control knob clockwise to the lowest speed position. - 13 -

Fig. 4.2 Flush to the outside of wall with wall grille Fig. 4.3 Flush to the outside of wall with air filter & rear exhaust grille - 14 -

Fig. 4.4 Top exhaust with air filter & rear exhaust cover Fig. 4.5 Flush to the racks or the inside of wall with air filter & rear exhaust grille NOTE: Insulate any cold surfaces of cooling unit for better performance if exposed to the outside. - 15 -

3. Through-wall installation with hot-air exhaust and ambient-air intake ducts (Fig. 4.6 & 4.7) It is the installation when the cooling unit can not exhaust the hot air to an adjacent space. 1) The cooling unit shall be mounted near the ceiling with equal distance from each side of the cellar. 2) Cut a rectangular opening between two wall studs. The dimensions of the opening shall be 1/4 larger than the width and height of the cooling unit. 3) Construct a shelf as shown. The shelf must be capable of supporting the weight of the cooling unit and preventing it from moving. 4) Place the cooling unit on the shelf with the back of the unit flush with the outside of the wall. 5) Seal the clearance between the cooling unit and opening with a high quality weather stripping, polyurethane spray foam, or foam tape. Cover the seal with molding and attach the molding to the wall not the unit. 6) Attach the duct hoods to the rear of the cooling unit with screws (Use #8 x ½L screws only). 7) Attach the insulated ducts to the hoods with adhesive tapes. 8) Secure the ducts with conduits to the cellar exterior walls and make sure they are not curled, twisted, bent and clogged. 9) Install an air filter at the rear of the cooling unit. 10) Plug the unit into a properly grounded and dedicated outlet of adequate capacity. 11) Turn on the high condenser fan switch. 12) Turn the evaporator fan control knob clockwise to the lowest speed position. NOTE: The exhaust and intake ducts can be combined maximum 50 ft long. The cooling unit can also be installed with its front flush with the racks or the inside of the wall. Insulate any cold surfaces of cooling unit for better performance if exposed to the outside. - 16 -

Fig. 4.6 Flush to the outside of wall with hot-air exhaust & ambient-air intake ducts Fig. 4.7 Flush to the outside of wall with hot-air exhaust duct & air filter 4. In-cellar installation with hot-air exhaust and ambient-air intake ducts (Fig. 4.8, 4.9, 4.10 & 4.11) It is the installation when the cooling unit is installed away from the wall. NOTE: The exhaust and intake ducts can be combined maximum 50 ft long. - 17 -

Fig. 4.8 In-cellar with hot-air exhaust & ambient-air intake ducts Fig. 4.9 In-cellar with hot-air top exhaust duct to attic & ambient-air intake ducts - 18 -

Fig. 4.10 Floor-mount with hot-air top exhaust duct to attic & ambient-air intake duct Fig. 4.11 Floor-mount with hot-air top exhaust duct to attic & air filter &rear exhaust cover 5. Through-wall installation with cold-air supply ducts (Fig 4.12) It is the installation when the cooling unit is located away from the wine rack. NOTE: - 19 -

The supply duct can be maximum 50 ft long. The cooling unit can also be installed with other configurations shown above. Fig. 4.12 Flush to the outside of wall with cold-air supply duct & wall grille 6. Remote installation with cold-air supply and cellar-air return ducts only (Fig. 4.13) It is the installation when the cooling unit can not be installed inside the wine room but it can exhaust the hot air to an adjacent space. NOTES: The supply and return ducts can be combined maximum 50 ft long. Insulate the cold side of cooling unit for better performance. If the air probe is in a return duct, the evaporator fans shall be running all the time. Meanwhile the set-point shall be adjusted accordingly due to the temperature differential between return duct air and the cellar air. 1) Cut two circular openings at the wine cellar ceiling or wall as illustrated. 2) Secure the cooling unit on the top of the wine cellar or other strong flat places 3) Remove the front cover of the cooling unit. 4) Attach the duct hoods to the front the cooling unit with screws (Use #8 x ½L screws only). 5) Attach the insulated ducts to the hoods with adhesive tapes. 6) Secure the ducts with conduits to the wine cellar ceiling and exterior walls and make sure they are not curled, twisted, bent and clogged. - 20 -

7) Install a rear exhaust grille and an air filter at the rear of the cooling unit. 8) Plug the unit into a properly grounded and dedicated outlet of adequate capacity. 9) Turn the evaporator fan control knob counter-clockwise to achieve the required air flow CFM. Fig. 4.13 Cold-air supply and cellar-air return ducts only 7. Remote installation with cold-air supply, cellar-air return, hot-air exhaust and ambient-air intake ducts (Fig. 4.14 & 4.15) It is the installation when the cooling unit can not be installed inside the wine room and it can not exhaust the hot air to an adjacent space. NOTES: The supply and return ducts can be combined maximum 50 ft long. The exhaust and intake ducts can be combined maximum 50 ft long. Insulate the cold side of cooling unit for better performance. If the air probe is in a return duct, the evaporator fans shall be running all the time. Meanwhile the set-point shall be adjusted accordingly due to the temperature differential between return duct air and the cellar air. 1) Cut two circular openings at the wine cellar ceiling or wall as illustrated. 2) Secure the cooling unit on the top of the wine cellar or other strong flat places 3) Remove the front cover of the cooling unit. 4) Attach the duct hoods to the front and rear of the cooling unit with screws (Use #8 x ½L screws only). - 21 -

5) Attach the insulated ducts to the hoods with adhesive tapes. 6) Secure the ducts with conduits to the wine cellar ceiling and exterior walls and make sure they are not curled, twisted, bent and clogged. 7) Install an air filter at the rear of the cooling unit. 8) Plug the unit into a properly grounded and dedicated outlet of adequate capacity. 9) Turn on the high condenser fan switch. 10) Turn the evaporator fan control knob counter-clockwise to achieve the required air flow CFM. Fig. 4.14 Cold-air supply, cellar-air return, hot-air exhaust and ambient-air intake ducts - 22 -

Fig. 4.15 Cold-air supply, cellar-air return and hot-air exhaust ducts - 23 -

Care Guide 1. Cleaning Condenser Clean the condenser and air filter regularly. Condenser and filter may need to be cleaned at least every 6 months. Condenser and air filter are located on the ambient air intake side of the cooling unit. Use a condenser brush or a vacuum cleaner with an extended attachment to clean the condenser. Air filter is washable and reusable. 2. Removing Condensate Remove the excessive condensate if it is accumulated on the cooling unit in high humidity conditions. 3. Removing Unit When you remove the cooling unit, beware water may come out of the unit. 4. Installing Drain Line The unit is equipped with an additional drain fitting. In case of extreme humidity there is a drain line needed, remove the drain plug on the bottom left at the rear, then remove the connection plug and fit a 0.375 OD drain tube into the drain connection. Install the cooling unit with the front higher than the rear. - 24 -

Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Complaint Possible Causes Response a. Power cord not plugged b. No power from supply c. Incorrect or loose wirings d. Low voltage e. Setting higher than ambient temperature f. Cut-in too high g. Defrost light blinking h. Compressor light blinking i. Defective controller i. Call service for diagnosis 1. Unit not running 2. Unit not starting, but temperature rising high 3. Temperature fluctuating 4. Temperature high, unit stopping and starting normally 5. Temperature high, unit stopping and starting with short running time a. Anti-short cycle a. Reset AC a. Check power cord b. Check receptacle and fuses c. Check all wirings and connections d. Contact an authorized electrician e. Lower temperature setting f. Reduce Hy g. Unit is under defrost mode h. Unit is under anti-short cycle delay a. Air probe a. When using an air probe, the wine bottle temperature is mainly controlled by the average air temperature. If the set-point is 55 F with the differential 4F, the cooling unit turns on at 59 F of air temperature (It may be higher than 59 F if it is in anti-short cycle or defrost cycle) and turns off at 55 F of air temperature. The average air temperature is 57 F, and then the wine temperature is around 57+/- 0.5 F. The air is light enough to change so quickly that it maintains relatively constant average temperature that would prevent wine bottle temperature from fluctuating. a. Temperature setting high a. Lower the setting a. Air probe touching the a. Move the air probe away from the evaporator coil, displaying evaporator temperature ok b. Short circuit of air flow between b. Deflect the supply air down cold-air supply and cellar-air return, displaying temperature ok c. Failed controller and probe c. Call service for diagnosis 6. Temperature a. Improper cellar insulation & seal a. Check insulation, gasket and door - 25 -

high or not cooling and running continually 7. Unit running too long 8. Fan motor running but compressor not running 9. Compressor running but fan not running 10.Temperature high, compressor stopping and starting but very short running time 11.Fan running too long b. Cellar too large c. Ambient temperature too high d. Exhaust restricted e. Malfunctioning fans f. Evaporator or condenser airflow g. Dirty Condenser h. Iced evaporator i. Refrigeration system restriction j. Refrigerant leak k. Undercharge or overcharge l. Failed components a. Improper cellar insulation & seal b. Cellar too large c. Ambient temperature higher > 90 F d. Exhaust restricted e. Dirty Condenser f. Improper condenser air flow a. Post-compressor fan running mode b. Incorrect or loose wirings c. Failed components d. Liquid refrigerant in the compressor a. Fan blade stuck b. Incorrect or loose wirings c. Failed motors a. Failed components b. Improper condenser airflow c. Dirty condenser d. Overcharge of refrigerant e. Discharge or suction pressure too high a. Post-compressor fan running mode for humidity modulation 12.Temperature a. Low temperature setting opening b. Check for excessive size c. Check installation location d. Leave minimum 3 feet clearance for the hot air exhaust side and leave minimum 1 foot clearance for the fresh air intake side e. Check for both evaporator and condenser fans f. Check for air restrictions, air shortcirculation, grille directions g. Clean condenser h. Defrost and reset temperature i. Call service j. Call service k. Call service l. Check compressor windings, start relay and overload protector a. Check insulation, gasket and door opening b. Check for excessive size c. Check for installation location d. Leave minimum 3 feet clearance for the hot air exhaust side and leave minimum 1 foot clearance for the fresh air intake side e. Clean condenser f. Check for fan and air short circulation a. Check fan running time FON b. Check all wirings and connections c. Check start relay, start capacitor, overload protector, compressor. d. Call service. a. Check for proper clearance b. Check all wirings c. Call service a. Check compressor windings, start relay and overload protector. b. Check for condenser fan c. Clean condenser d. Call service for removing refrigerant e. Call service for information a. Reset FON a. Raise the setting - 26 -

low 13.Evaporator freezing up 14.Water leak 15.Excessive condensate in wine cellar 16.Condensate inside ducts 17.Condensate outside ducts 18.Circuit tripping 19.Noisy operation b. Low ambient temperature c. Air probe fault d. Temperature controller fault a. Evaporator air flow restriction b. Low temperature setting c. Low ambient temperature d. Defective controller or probe e. Not stopping due to air leak, high ambient temperature, condenser air flow restriction or pull-down cooling f. Initially working then stopping, moisture in the system g. Refrigerant low or leaking h. Capillary tube or expansion valve blockage a. Air leak in the wine cellar causing excessive condensate b. High humidity causing excessive condensate c. Evaporator air flow restriction d. Water passages restricted e. Unit not level (No water overflow but water leak) f. Drip tray leak (No water overflow but water leak) a. Air leak in the wine cellar causing excessive condensate b. High humidity causing excessive condensate c. Water passages restricted a. Drain line restricted b. Continually running not stopping c. Too cold supply air a. Duct not insulated b. High humidity c. Too cold supply air a. Incorrect fuse or breaker b. Incorrect wirings c. Failed components a. Mounting area not firm b. Loose parts c. Compressor overloaded due to high ambient temperatures or airflow restriction d. Defective components b. Move to another location c. Change a new one d. Change a new one a. Check for fans and air flow b. Check for set-point c. Change defrost cycle d. Check for controller and probe e. Check for seal, door opening, ambient temperature and condenser air flow f. Call service g. Call service h. Call service a. Check for air leak b. Use drain line c. Check supply air flow or air TD d. Clean the drip tray e. Check unit level f. Seal the leak using silicone sealant a. Check for any air leak b. Use drain line c. Clean the drip tray a. Check for drain b. raise temperature setting or increase defrost cycle c. Increase air flow or raise temperature setting a. Check for insulation b. Use dehumidifier c. Increase air flow or raise temperature setting a. Check for proper fuse or breaker b. Check for wirings and connections c. Call service a. Add support to improve installation b. Check fan blades, bearings, washers, tubing contact and loose screws. c. Check for airflow d. Call service for checking internal loose, inadequate lubrication and incorrect wirings - 27 -

Electrical Wiring Diagrams Fig. 7.1 WM-4510 ~ 8510HZD standard wiring diagram - 28 -

Fig. 7.2 WM-4510 ~ 8510HZD crankcase heater wiring diagram - 29 -

Fig. 7.3 WM-4510 ~ 8510HZD alarm call wiring diagram - 30 -

Fig. 7.4 WM-4510 ~ 8510HZD cellar heater wiring diagram - 31 -

Fig. 7.5 WM-4510 ~ 8510HZD crankcase heater & alarm call wiring diagram - 32 -

Fig. 7.6 WM-4510 ~ 8510HZD crankcase heater & cellar heater wiring diagram - 33 -

Fig. 7.7 WM-4510 ~ 8510HZD alarm call & cellar heater wiring diagram - 34 -

Fig. 7.8 WM-4510 ~ 8510HZD crankcase heater, alarm call & cellar heater wiring diagram - 35 -

Customer Support If you need further assistance, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com - 36 -

Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and serial numbers in the space provided: Model Serial No. Attach your purchase receipt to this owner s manual. 1. Limited Warranty VINOTEMP warrants its products, parts only, to be free from defects due to workmanship or materials under normal use and service for twelve months after the initial sale. If the product is defective due to workmanship or materials, is removed within twelve months of the initial sale and is returned to VINOTEMP, in the original shipping carton, shipping prepaid, VINOTEMP will at its option, repair or replace the product free of charge. This warranty constitutes the entire warranty of the VINOTEMP with respect to its products and is in lieu of all other warranties, express or implied, including any of fitness for a particular purpose. In no event shall VINOTEMP be responsible for any consequential damages what is so ever. Any modification of VINOTEMP products shall void this warranty. Service under Warranty This service is provided to customers within the continental UNITED STATES only. VINOTEMP cooling units are warranted to produce the stated number of BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty. Shall a VINOTEMP cooling unit fail, contact the dealer for instructions, do not return the unit to the factory without authorization from VINOTEMP. If the unit requires repair, re-pack it in the original shipping carton and return it to the factory, shipping prepaid. VINOTEMP will not accept COD shipments. If the unit -37-

is determined to be faulty and is within the twelve month warranty period VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation of Implied Warranty VINOTEMP S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT. VINOTEMP SHALL NOT BE LIABLE FOR: DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE UNIT, DAMAGES BASED UPON INCONVENIENCE, LOSS OF USE OF THE UNIT, LOSS OF TIME OR COMMERCIAL LOSS, ANY OUTER DAMAGES, WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly cool a particular enclosure. Customers are cautioned that enclosure construction, unit location and many other factors can affect the operation and performance of the unit. There for suitability of the unit for a specific enclosure or application must be determined by the customer and cannot be warranted by VINOTEMP. Protect Your Investment with an Extended Warranty! Add a New Leaf extended warranty to your order, and have the security of knowing that if there should be a problem, even years in the future, New Leaf will be there to assist! Usable for any Wine Cellar or other electronic device manufactured by Vinotemp. Add this warranty to purchases made from vinotemp.com or other qualified vendors. Warranty must be registered within the first 10 days from original purchase. Visit www.vinotemp.com to purchase. -38-