CALIBRATION KIT #

Similar documents
FLOW METER KIT #

CBT Bowl & wrap replacement

CF35 # INSTALLATION & OPERATION

cbt lw MAINtENANcE guide

RH 800 & 2000 COMMERCIAL INSTALLATION GUIDE

BMC OPERATION AUTOMATIC & MANUAL SYSTEMS

CBT LW MAINTENANCE GUIDE

POLISHING DRUMS DODECAGON

Refrigerant Recovery Machine. Model No Operating Manual

OPERATION & MAINTENANCE MANUAL AC860

OPERATION & MAINTENANCE MANUAL RHS680

Automatic Water System Pump SERIES

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Ultra. Product Identifier according to Art.18 of Reg. (EC) No 1272/2008 [CLP]: GARLON ULTRA, Triclopyr Triethylamine Salt

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

TSS 15/55 Hi-Lift Vacuum

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Caresaver Universal Refrigerant Recovery Unit

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

PS /2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Installation Instructions

PWASH Gallon Parts Washer Assembly & Operating Instructions

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

FIREPLACE INSTALLATION

Icade. 1 Litre HERBICIDE P

PRE-INSTALLATION PROCEDURE

50T Electric Shop Press

Safe Operation Manual. Honeywell IQ Force Gas Detector

PRE INSTALLATION PROCEDURES

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

ELECTRIC DRILL INSTRUCTIONS. Item #21285

OPERATION & MAINTENANCE MANUAL TX600

100T Electric Shop Press

Page 1 of 18. Part# /5/2013

PRO 2000i LOW LEVEL DEPOSITOR

55-Gallon Dispenser Package

Residential Piping and Long Line Guideline

Instruction Sheet DANGER

Instruction Sheet DANGER

TrueClean ToteCleaner

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

SPECIFICATIONS FEATURES

BAYTAN 30 CAUTION. 1 Gallon. Flowable Fungicide KEEP OUT OF REACH OF CHILDREN. For Use Only by Commercial Seed Treaters.

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

CLOSED TRANSFER SYSTEM

Models: GW/R-T GW/R-2-T GW/R-3-T

RANCONA V RS Fungicide

Approved MAXIM PSP Page 1 of 5 MAXIM PSP

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

Lime Buster III. Model LB-300P IMS # (CIC1-LB300P) INSTRUCTION MANUAL

Installation Instructions

Dual Column Dehydrating Breather Manual

Installation Instructions

Safety Warnings. Work area safety. Electrical Safety. Personal Safety

G45 FastTrack. Page 1 of 8

Replacing a Gun Thermostat

PowerVac G Single to Twin Conversion Kit [ ]

OPERATOR'S MANUAL CD 400 / CD 500

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

REMOTE COOLER AIR COOLED & WATER COOLED

Installation & Operation Manual Models:

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference)

UV Lamp and Quartz Sleeve Replacement/Maintenance

Installation, commissioning and servicing instructions

ELECTRIC BODY SAW INSTRUCTIONS. Item #31660

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

Installation, Operating, and Maintenance Manual

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Cast Iron Commercial Hot Water Or Steam Boiler

Installation Instruction

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

17 U.S. gallon portable low profile drain with electric pump

AIR OPERATED CLUTCH & BRAKE BLEEDING KIT. MODEL NO: CHT637 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC01/12

SPECIMEN PRO. A foliar acting herbicide for the control of DOCKS in ESTABLISHED GRASSLAND.

Instruction Manual Suppository Penetration Tester. Type PM 30

TCPSeries Installation Operation & Maintenance

INSTALLATION INSTRUCTIONS

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

OPER LV Wheeler Way

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

'' Stone Fireplace Model# SRFP41301 Instructions Manual

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

Transcription:

CALIBRATION KIT #79689837

2 General information This manual contains technical information regarding Bayer SeedGrowth Equipment. Please read and understand these instructions completely before proceeding to install and operate the equipment. Bayer reserves the right to change specifications, models, components, or materials at any time without notice. For additional equipment information contact us at 1.800.634.6738. Please have this manual available when contacting Bayer. This manual uses signal words and symbols to help avoid personal injury. Danger, Warning, and Caution are signal words used to identify the level of hazard. Danger alerts that an extreme hazard will cause serious injury or death if operators or installers do not follow the recommended precautions. Warning alerts that a hazard may cause serious injury or death if operators or installers do not follow the recommended precautions. Caution alerts that a hazard may cause minor or moderate injury if operators or installers do not follow the recommended precautions. Always use caution and common sense when working with any chemical. Read the product label and SDS carefully and follow their instructions exactly as described. Optimal operating conditions for this piece of equipment requires an ambient temperature 32 F to +104 F (0 C to +40 C), relative humidity less than 90% (minimum condensation). Make necessary provisions to protect this piece of equipment against excessive dust, particles containing iron, moisture and against corrosive and explosive gases. Our technical information is based on Tip: calls attention to special information. extensive testing and is, to the best of our current knowledge, true and accurate but Note: emphasizes general information worthy of attention. given without warranty as the conditions of use and storage are beyond our control. Variables, such as humidity, temperature, Example: gives a problem or exercise that illustrates a method or principle. change in seed size or variety and viscosity of chemical products can all affect the accuracy of the chemical application and seed coverage. To ensure the desired application rate and optimum seed coverage, check the calibration periodically throughout the day, and make adjustments as needed. Bayer Crop Science Division 1451 Dean Lakes Trail Shakopee, Minnesota 55379 USA Phone: +1 952 445 6868 Toll Free: +1 855 363 3152 E-mail: equipment@bayer.com Web: www.seedgrowth.bayer.com Bayer SeedGrowth TM and the Bayer Cross are registered trademarks of Bayer. SGRCALIBRATIONKIT01132016

CONTENTS 3 CONTENT #1 SYSTEM DIAGRAM 04 #2 EQUIPMENT INSTALLATION 05 On a CBP without a Flow Meter 05 On a CBP with a Flow Meter 08 #3 EXPOSURE CONTROL 11 #4 CALIBRATION 12 CBP Tank with I/P Pump & RH Basic 12

4 System Diagram SYSTEM DIAGRAM TOP MOUNT CALIBRATION KIT 100oz Calibration Beaker End Caps Union Tee Mount Plate Main Run Tee Shut-off Valve EXPLANATORY NOTES Dry Weight 8.2lbs [3.7kg] Overall Height 22.28 [566mm] Capacity: 100oz [3L]

EQUIPMENT installation 5 Installation Required assembly tools Hose Cutter (1) 7/16 Wrench (1) 1/2 Wrench (1) Step 3: Connect the Shutoff Valve to the piece of 1/2 Tubing. Installation on CBP Tank without a Flow Meter Step 1: Connect the Calibration Mount Plate to the Tank Agitation Motor Base with factory supplied hardware in this order: bolt+[tank Motor Mount + Calibration Mount Plate]+wiz nut. Tighten securely. Step 4: Remove the Calibration Port Plug from the top of the Tank. Cut to fit a piece of the factory supplied 1/2 Tubing. Press it into the Shutoff Valve. Press the other end into the 90 Elbow Press-lock Fitting and install on top of the CBP Tank. Step 2: Cut a 3 piece of the factory supplied 1/2 Tubing. Press it into the Male Run Tee (attached to the bottom of the Calibration Cylinder). Step 5: Connect one end of the factory supplied 1/2 Recirculation Tube to the Male Run Tee located underneath the Calibration Tube.

6 Equipment installation Step 6: Cut to fit and connect the other end of the Vent Tube to the Press-lock Fitting on the pump, located underneath the CBP Tank. Step 9: Press in the remaining Tubing into the Union Tee. Step 7: Remove the second Vent Plug from the top of the CBP Tank. Cut a 2 piece of Tubing. Press it into the Vent Press-lock Fitting. Step 10: Cut to fit and connect the remaining piece of Tubing to the 90 elbow press-lock fitting, located on top of the Calibration Tube. Step 8: Press the Union Tee onto the 2 piece of tubing. Step 11: Connect one end of the remaining 20 Vent Tube to the Union Tee.

Equipment installation 7 Step 12: Cut to fit and connect the other end of the Vent Tube to the Press-lock Fitting on the pump, located underneath the CBP Tank. Step 13: Connect one end of the Transfer Tube to the Press-lock Fitting on the pump, located underneath the CBP Tank. Step 14: Insert the other end of the Tubing into the Treater Chemical Inlet Assembly Press Lock Fitting. Top Calibration installed without a Flow Meter

8 Equipment installation Installation on CBP Tank with a Flow Meter Step 1: Connect the Calibration Mount Plate to the Tank Agitation Motor Base with factory supplied hardware in this order: bolt+[tank Motor Mount + Calibration Mount Plate]+wiz nut. Tighten securely. Step 4: Remove the Calibration Port Plug from the top of the Tank. Cut to fit a piece of the factory supplied 1/2 Tubing. Press it into the Shutoff Valve. Press the other end into the 90 Elbow Press-lock Fitting and install on top of the CBP Tank. Step 5: Connect one end of the factory supplied 1/2 Recirculation Tube to the Male Run Tee located underneath the Calibration Tube. Step 2: Cut a 3 piece of the factory supplied 1/2 Tubing. Press it into the Male Run Tee (attached to the bottom of the Calibration Cylinder). Step 3: Connect the Shutoff Valve to the piece of 1/2 Tubing. Step 6: Connect the other end of the Recirculation Tube to the 1/2 Press-lock Fitting on the Flow Meter Assembly (right side).

Equipment installation 9 Step 7: Remove the second Vent Plug from the top of the CBP Tank. Cut a 2 piece of Tubing. Press it into the Vent Press-lock Fitting. Step 10: Cut to fit and connect the remaining piece of Tubing to the 90 elbow press-lock fitting, located on top of the Calibration Tube. Step 11: Connect one end of the remaining 20 Vent Tube to the Union Tee. Step 8: Press the Union Tee onto the 2 piece of tubing. Step 12: Cut to fit and connect the other end of the Vent Tube to the Press-lock Fitting on the pump, located underneath the CBP Tank. Step 9: Press in the remaining Tubing into the Union Tee.

10 Equipment installation Step 13: Cut to fit and connect the other end of the Transfer Tube to the Press-lock Fitting underneath the Flow Meter. VENT TREATMENT RECIRCULATION VENT Step 14: Connect one end of the Treatment Tube to the Press-lock Fitting on the Flow Meter Assembly (left side). FLOW METER TRANSFER Top Calibration installed with a Flow Meter Step 15: Insert the other end of the Tubing into the Treater Chemical Inlet Assembly Press Lock Fitting. Note: Use the same instructions to install a Calibration Kit onto a PSD Tank. LP300 Tanks are assembled and shipped from the factory with the Calibration Kit installed.

Exposure Control 11 Exposure Control Always use caution and common sense when working with chemicals. Read the product label and SDS carefully and follow their instructions exactly as described. The following Personal Protective Equipment (PPE) recommendations and best practices help promote safe use in seed treatment. Wear protective clothing Wear disposable or reusable coveralls with long sleeves. Hand protection required Wear chemical-resistant gloves. Treatment products Keep products in a locked room that has been approved for crop protection products. Wear a mask Wear respiratory protection. Wear rubber boots Wear chemical resistant rubber boots. Eye protection required Wear protective eyewear. Labels Label recommendations and directions for handling must be followed, including treatment procedure (use of sticker) as well as the safety requirements. Calibration Seed treatment equipment must be checked and calibrated regularly to ensure accurate and safe application. Clean seed Use well cleaned seed to avoid creation of polluted dust that will contaminate the treating facility, workers, farmers and the environment during sowing. Cleaning Use a vacuum to clean machines and coveralls. Never use compressed air. Laundry Wash soiled reusable clothing separately. Workers must take a shower after each shift. Empty containers Non-returnable empty containers must be triple rinsed before they can be disposed. For others the recommendation of the producer must be followed. Spillage Spillage must be avoided; it must be thoroughly cleaned up to avoid contaminating the environment and waterways. Maintenance Keep machinery clean between treating sessions.

12 Calibration Calibration Required calibration tools Step 3: Ensure the Pump Head is clamped down onto the Pump Element! Stopwatch or watch with a second hand. Calibration - CBP Tank with I/P Pump & RH Basic Step1: Connect the Tank Agitation Power Cord to an external 115VAC power source. Tank agitation begins when power cord is plugged into power source. Step 4: Ensure the Main Flow Valve underneath the CBP Supply Tank from the Filter is in the TREAT mode. Step 5: Ensure the Recirculation Valve is in the recirculation mode. Step 2: Open the Tank Cover Lid and pour in desired chemicals. Allow chemicals to agitate for a few minutes.

Calibration 13 Step 6: Ensure the Tank Valves are in the TREAT mode. Step 9: Ensure the RH Basic Main Power Switch is in the ON position (UP) Power light will also indicate that the power is ON when lit. POWER Step 7: Turn the Drain Valve underneath the calibration Tube to the right. Step 10: Turn the RH Basic PUMP #1 Switch to the PRIME position. The Pump will run, purging the treatment lines of air and fill with chemical. Then turn PUMP #1 Switch to OFF position. Repeat for all Pumps used (1-4). PUMP 1 PUMP 1 Step 8: Set the Pump Control to the FORWARD position.

14 Equipment installation Step 11: Turn the RH Basic PUMP #1 Switch to the PRIME position. Step 14: Turn the RH Basic PUMP #1 Switch to the PRIME position. PUMP 1 PUMP 1 Step 12: The Pump will run, filling the Calibration Graduated Beaker with chemical just up to the ZERO mark. Step 15: The Pump will run, filling the Calibration Graduated Beaker with chemical for one minute. Step 13: Turn the RH Basic PUMP #1 Switch to OFF position. PUMP 1 Step 16: Turn the RH Basic PUMP #1 Switch to OFF position. Ensure chemical does not drain from the graduated cylinder! If required, open and close the Drain Valve to ensure the Valve properly seals! PUMP 1

Equipment installation 15 Step 17: Note the amount (ounces) of chemical added to the Beaker in one minute. Compare that number to the chemical product label requirement. Adjust the Dial on the LS Pump Control (increase or decrease) to achieve desired Pump output speed. Step 20: Turn the RH Basic PUMP #1 Switch to the PRIME position. The Pump will run, purging the treatment lines of air and fill with chemical. Then turn PUMP #1 Switch to OFF position. Repeat for all Pumps used (1-4). PUMP 1 PUMP 1 Step 18: Turn the Drain Valve underneath the calibration Tube to the right. Chemical will drain from the Beaker back into the Supply Tank. Repeat these calibration steps for each Supply Tank used until desired calibration results are achieved. Note: Check pump calibration on each lot of seed. If extremely high or low temperatures exist, the viscosity and flow of certain treatment products may be affected. A typical example would be treating early in the morning at colder temperatures compared to treating in the afternoon when the temperature has increased. Step 19: When calibration is complete, turn the Recirculation Valve in the TREAT mode.

Bayer Crop Science Division 1451 Dean Lakes Trail Shakopee, Minnesota 55379 USA For fast and easy access to our website scan the code with your smartphone and an appropriate app. www.seedgrowth.bayer.com