PRODUCT GALLERY. belgas.net

Similar documents
A D I V I S I O N O F M A R S H B E L L O F R A M PRODUCT GALLERY

TK-1001, 1101, 1201, 1301, 1601

Commercial Tankless Rack System

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Commercial Tankless Rack System

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

Commercial Tankless Rack System

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

EZ TANKLESS EZ DELUXE OPERATION & INSTALLATION MANUAL

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

GB Condensing Gas Boiler

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

Tankless Water Heaters

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

GB Condensing Gas Boiler

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat


AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

Flow Control for Fire Protection

PART NO. COMBUSTION AIR CAP

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

iq251, Gen II Submittal Data

TEMPERATURE CONTROLLERS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

B. Product Certificates: For each type of meter and gage, from manufacturer.

Residential/Commercial Gas Condensing Tankless Models

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

iq1001, Gen II Submittal Data

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

WAL-RICH CORPORATION SINCE 1950

i200, Gen II i250, Gen II Submittal Data

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

SECTION METERS AND GAGES FOR HVAC PIPING

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

CATALOG OF REPLACEMENT PARTS

Compressed Air Filters

TECHNICAL DATA OBSOLETE

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

TECHNICAL DATA. model c-2

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

Flow Control for Fire Protection

SECTION METERS AND GAGES FOR PLUMBING PIPING

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN AQUAS Pool Package

SERIES 19A. mith PRESSURIZED WET BASE

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

advanced : technology

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

SECTION HEATING BOILERS

Series 300 VTB. Installation Instructions

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

23 11/32 [593] Ø8 AIR INLET [203] 6 5/8 [168] 44 3/4 [1137] TOP VIEW ASUB-31 REV. B 38 11/16 [983] 3 NPT BOILER OUTLET WIRING CONNECTIONS 1 NPT 1 NPT

Residential Gas Tankless Water Heater

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

C1210ESC Tankless Water Heater

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

GB Condensing Gas Boiler

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

Rental Boiler Specifications (Nebraska Boiler)

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Intelligent Refrigeration Solutions

Twin-Agent Fire Fighting/Securing Systems Specifications

YALE Site Specifications AIR VENT SCHEDULE

NPE-A and NPE-S Condensing Tankless Water Heaters

MGD Gas Chromatograph

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

TECHNICAL DATA OBSOLETE

PRECISION CONTROL FROM MYSON PLUS

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Peerless Pump Company

Commercial Tankless Rack System

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

C1210ES Tankless Water Heater

TANKLESS WATER HEATER HEATING SOLUTIONS

Tankless Condensing High Efficiency Water Heaters

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

AM-14/AM-14C DISHWASHERS

C1050ES Tankless Water Heater

INDUSTRIAL CONDENSATE POLISHERS. LWTCP Series

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

NPE-A and NPE-S Condensing Tankless Water Heaters

DigiTemp. Digital Water Tempering System. PVI.com

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Residential & Commercial

Transcription:

PRODUCT GALLERY belgas.net

* ratings at wide open flow / Methane P50 Direct Operated - Instrument Supply, Particulate and Condensate Collection to 120 psi P912 Direct Operated - Low Pressure/Low,, Minimal Relief 3 WC to 5 psi 750 scfh Cv 0.087, 3/8 P40, Self-Relieving to 120 psi P36 60 psi P143, 3.5 WC to 6 psi 2,000 scfh Cv 0.455, 1 P32 to 120 psi P70, Self Relieving to 5,280 scfh Cv 0.462, 3/8, 1/2 P52SS Direct Operated -Stainless Instrument Supply, Particulate and Condensate Collection 425 psi 3 to 6,300 scfh Cv 0.782, 3/8, 1/2, P600 Direct Operated - 8 Diaphragm, Commercial, NG Engines - Relieving Optional 4 WC to 7 psi 6,500 scfh Cv 7.0 P37 400 psi 6,600 scfh Cv 0.443 1/2, 3/4 P39 Direct Operate - High Pressure Reducing for Instrument Supply 6,000 psi 5 to 500 psi 12,000 scfh Cv 0.130 P38 400 psi 15,000 scfh Cv 1.10 3/8, 1/2,

* ratings at wide open flow / Methane P201, Non-Relieving 30,000 scfh 1, 1 1/2, 2, P202, 30,000 scfh 1, 1 1/2, 2, P203, 3.25 psi 30,000 scfh 1 1/2, 2, F627 Pilot Operated - Farm Tap or Gate, ideal for Fixed Factor 5 to 2 ranges 39,000 scfh, 2, Socket, L627 Direct Operated - Propane specific design, UL Listed 5 to 40 psi 2 ranges 46,400 scfh, 2 P630 Direct Operated - First Stage High Pressure, Farm Tap, Gas Gathering 1,500 psi 3 to 500 psi 10 ranges 141,000 scfh Cv 8.20 1, 2, P98H Direct Operated - Back Pressure/ Relief in Steam, Liquids, Oil Production 5 to 200 psi 9 ranges 157,000 scfh Cv 16.60, P133 Industrial Commercial 60 psi 10 ranges 170,000 scfh Cv 51.40 2, P133K Direct Operated - 10 Diaphragm, 2 to 60 psi 370,000 scfh Cv 51.40 2, P627 Direct Operated - Farm Tap, City Gate, Gas Gathering 2,000 psi 5 to 500 psi 172,000 scfh, 2, Socket, R627 Direct Operated w/internal relief 2,000 psi 5 to 172,000 scfh, 2, Socket, P95H Direct Operated - Air, Steam, Liquids, Industrial & Heating Gases 5 to 8 ranges 199,000 scfh Cv 12.50 1/2,, P99 Pilot Operated - Boilers, Pneumatic Headers, Large Commercial Gas 1,000 psi 3 WC to 8 ranges 265,000 scfh Cv 24.0 2, W627 Direct Operated - Liquid Service High & Low Pressure 900 psi 10 to 500 psi 82 gpm Cv 3.76, 2,

* ratings at wide open flow / Methane Relief Outlet Range P630R High Relief - Field Adjustable, Gas, Air 3 to 9 ranges 48,000 scfh Cv 12.08 1, 2, P255 Direct Operated - Relief Pop-Off/ Reset Valve, Gas Distribution, Air 25 psi 50 to 7 settings 60,000 scfh Cv 5.25 L289 Back Pressure/Relief - Gas Distribution, Liquids, Air, Propane Gas 25 psi 5 WC to 40 psi 120,000 scfh Cv 17.50, 2 All 2 Outlet P289 Back Pressure/Relief - Gas Distribution, Liquids, Air, Propane Gas 7 WC to 75 psi 10 ranges 120,000 scfh Cv 17.50 3/4 x 1, 1, 2 F289 Pilot Operated Back Pressure/Relief - Gas Distribution, Air 137,000 scfh Cv 17.50 3/4 x 1, 1, 2 P1808 Back Pressure/Relief - Pilot Operated, Gas Distribution, Liquids, Air 3 to 258,000 scfh Cv 51.0 2 - Straight, Angle or * ratings at wide open flow / Methane Access. Outlet Range P1367 High to Low Instrument supply train w/relief 4,000 psi 20 or 35 psi 20 scfh Cv 0.001 P350 Aluminum & Stainless Particulate Filter 4,000 psi 2,400 scfh Cv 1.0 75/P79V Volume Booster for Valve Actuation 75/ P79V/400 psi 1:1 to 1:6 ratio 4 options 12,000 scfh Cv 0.61 3/8, 1/2, PL81 Pilot, Ideal for P627 2 ranges PL82 Pilot, Ideal for 289 & P1808 - PSI ranges PL82B Pilot - Relieving Applications, Ideal for P289 & P1808 PL83 Pilot, Ideal for P289 & P1808 - WC Ranges P119 Throttling or On/Off Valve - Fuel Valve for Heaters & Treaters, Liquids & Gases 3 to 60 psi Cv 7.0, 1

New Products Available from * ratings at wide open flow / Methane Currently in Production and Ready for Sale P98 Direct Operated - Back Pressure / Relief for Air, Steam, Liquids and Oil Production 5 to 170 psi 57,000 scfh CV 15.80 1.5, 2 P95 Direct Operated for Air, Steam, Liquids, Industrial Gases, Heating Gases 5 to 150,000 scfh Cv 12.50 1.5, 2 P300 3.0 WC to 8 psi 8 ranges 5,000 scfh Cv 8.57 1, 1 1/2, 2 F200 Fixed Factor Billing Non-Relieving 4.0 WC to 37,290 scfh 1, 1 1/2, 2 P289RC High Capacity Exhaust Booster Surge Valves, Recycle Valves Speeds Proportional Operations Cv 22.0 3/4 x 1, 1 Completing development for January 2017 Production * ratings at wide open flow / Methane P140 Direct Operated - 6 Diaphragm, Light, Residential 5.0 WC to 5 psi 4,300 scfh Cv 2.28 3/4, 3/4x1, 1 1 P212 Full Relief 4.0 WC to 37,290 scfh 1, 1 1/2, 2 * ratings at wide open flow / Methane In development for 2017/2018 Production P208 - Slam Shut 2.0 WC to 25,000 scfh 1 1/2x2, 2 P303 - True Monitor 8.0 WC to 2.25 psi 5,000 scfh Cv 8.57 1 1/2x2, 2 P308 - Slam Shut 2.0 WC to 5,000 scfh Cv 8.57 1 1/2x2, 2

L Series - Bimetal Thermometers Dual Scale F / C Dials Stainless Case and Stems - 50 to 1000 Fahrenheit in 9 ranges J & X Series - Severe Service Severe & Rugged Service Applications 63mm & 100mm Dial Sizes Stainless Case, Brass or Stainless Tube & Socket Dual & Single Scale available Liquid Fill available H, HW & HN Series - Precision Service 8019 Ohio River Blvd., Newell, WV 26050 800-727-5646 LT 5042 10/16 2.5M Severe & Rugged Service Applications 100mm & 160mm Dial Sizes Stainless Case, Brass or Stainless Tube & Socket Dual & Single Scale available NACE Compliant Gauges available belgas.net