Installation Instructions for. CattleMaster Series Fountains

Similar documents
Installation Instructions for. OmniFount

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount

Installation Instructions for. DairyFount Series Fountains

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMatic Fountains

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions For

Installation Instructions For

Instruction Manual for. WaterMatic

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345-E

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Dishwasher Installation Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

FLCH4R Garage and Utility Electric Heater

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Installation Instructions

INSTALLATION INSTRUCTIONS

Panel Fan Series Operators Manual (Galvanized and Polymer)

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

Installation Instructions

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Instant Hot Water Dispenser Owner s Manual

ST. KITTS CEILING FAN

HE360 Humidifier Installation Kit

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

SERIES WATERERS INSTALLATION INSTRUCTIONS

Model: EF34. Owner's Guide & Installation Manual

Installation Instructions

SAVE THESE INSTRUCTIONS

Top Control Dishwasher

Oahu Showerspa Model #1035 Owner's Manual

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3370-S

INSTALLATION INSTRUCTIONS

Installation Instructions

Dishwasher Installation Instructions DW 24XT/DW 24XV

HE120, HE160 Humidifier Installation Kit

Installation Instructions

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)


SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3465

ASSEMBLY INSTRUCTIONS

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

OWNERS GUIDE TO INSTALLATION AND OPERATION

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

harborbreezeoutlet.com

KD-27A SERIES DISHWASHERS

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

Pump Out Vacuums Polyethylene & Steel

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

Viking Installation Guide

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

C-Box 100, H-Box 200 & H-Box 500

Xaact Spot. Xaact Hot Spot

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Electrical Mini Tank Water Heater anual, and Warranty nformation

L A signature series TA T N E RE O, A L L A T S IN

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Here is what comes in your box:

OPERATIONS MANUAL & PARTS LIST. BX2 Fastracts Extractor. IPC Eagle 3650 Dodd Rd, Eagan MN

SuperKlean Washdown Products

Installation S

Installation S

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Installation S

DISHWASHER INSTALLATION INSTRUCTIONS

HotLine Internal Sewer Pipe Heater Installation Manual

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Transcription:

Installation Instructions for CattleMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and maintained. Please follow instructions carefully. Read and understand all instructions before installing Ritchie Industries, Inc. 800-747-0222 Part # 17873 www.ritchiefount.com October 31, 2016 @RitchieWaterers

CattleMaster Series Installation Instructions SHUTOFF VALVE CONCRETE ANCHOR BOLT STANDARD DRAIN ELECTRICAL SERVICE PER LOCAL CODE RISER TUBE FROST LINE UNDERGROUND DRAIN OPTIONAL WATER SUPPLY A. Location - Installing the fountain in a location that offers protection from the wind will enhance the performance of the fountain. Livestock will tend to gather in this protected area, enticing them to drink more. Access panel should be opposite of prevailing winter wind to give additional protection to the supply line. B. Water Supply Line - Horizontal underground water line should be sized to account for pressure drop, relating to distance, and placed one foot below frost line. A one-inch vertical supply pipe is recommended. A shut-off valve should be installed under fountain to allow for easier servicing. For optimum serviceability, a stop and waste valve can be installed below frost level to drain water when unit is not in use. Vertical supply line must be centered in riser tube to provide an air space between the line and frozen ground outside of tube. Flush water supply line thoroughly before connection to fountain. Water supplies with foreign material such as sand, rust, etc. may require a filter to keep fountain valve working properly. C. Electric Supply It is generally most cost effective to run your electrical supply line at the same time you are trenching for your water supply. WARNING: ANY ELECTRICAL SERVICE MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED ELECTRICIAN. Ritchie Thermal Tube Part # Description D. Riser Tube - Install a riser tube and extend it at least one foot below frost line or down to horizontal underground water line. For optimum water line protection, use the 12 diameter insulated Ritchie Thermal Tube, part numbers and sizes are shown to the right. Tube opening must be kept clear. 18158 1 Top Section 16417 2 Top Section 16612 4 Top Section 16416 2 Extension NOTE: The supply line touching the riser tube is the most common cause of the supply line freezing. Do not surround the supply line with insulation, wood, or other foreign material. Any foreign material in the tube may cause frost to migrate to the supply line causing it to freeze. CattleMaster Series Instruction Manual 1 October 31, 2016

E. Mounting Platform - A concrete platform must be provided for all fountains. Use a minimum of 4 thick, (6 recommended thickness), large enough to accommodate fountain, and additional 4 step (on top of the platform) extending 18 out from each side of the unit. This will protect the unit from manure handling equipment, as well as discouraging animals from defecating in the fountain. Extending the platform provides animals a place to stand while drinking, consider the size of your animals when determining the dimensions of your platform. The concrete step and platform should slope away from the fountain for drainage and should be flush with the top of the thermal tube. A rough broom finish to concrete surface provides better footing for livestock. F. Preparing the Bottom - Apply the provided foam weather stripping to the bottom of the unit, along the outside edge of the fountain. G. Anchoring Fountain - CattleMaster Fountains have mounting pockets molded into the base. Use of Ritchie part #16555, stainless steel anchor bolts (not included), is recommended. Once you have verified the positioning of the fountain, drill, install, and tighten down anchor bolts. Use the large washers provided to hold unit down. Tighten hold down anchors tight, but do not over tighten as this could damage the plastic feet. Use an all-weather sealant under the outside edge when anchoring to concrete to keep air from leaking under fountain. NOTE: Do not drill holes for anchors before location can be verified with unit. H. Hose Connection Remove side panels and cover. Remove valve assembly from standpipe. Connect the hose to the valve assembly barb fitting and use a hose clamp to secure. Return the valve assembly to the standpipe. Pull the bottom of the hose to the shut-off valve at the top of the concrete. Leaving enough slack to be able to pull the valve assembly from the standpipe, cut hose to proper length and slip on barb fitting and hose clamp. Hose should not touch insulation or outside surface of fountain. Clamps and fittings are furnished to secure connections. I. Fenwal Thermostat The adjustable range of the Fenwal Thermostat is from 0 o F (-18 o C) to 100 o F (38 o C). The thermostat is not preset at factory. To adjust the thermostat to the desired temperature, first fill the trough to proper water level then check the water temperature with a thermometer. The next morning, check the water temperature again. If the water is warmer than desired, turn the thermostat down (clockwise). If there is ice forming on the surface of the water, turn the thermostat up (counter clockwise). Only slight adjustments should be made to the thermostat at any time. A 1/16 turn on the thermostat will change the water temperature 7 o F (4 o C). The most economical temperature for the trough is 44 o F (7 o C). J. Seal the Base - After the unit is completely installed, apply a bead of caulking around the base of the fountain to ensure no wind enters through the base of the unit. NOTE: Sealing the bottom of the unit from cold air is an important aspect of the unit's thermal performance. CattleMaster Series Instruction Manual 2 October 31, 2016

K. Drain Plug Insert the drain plug firmly into the drain hole in the trough. The plug can be tightened by tightening the eyebolt through the center of the plug. L. Water Seal Drain Install the small drain plug into the drain hole in the water seal groove around the valve chamber seal. This plug may be removed during the non-freezing periods to allow the water seal groove to drain. M. Electrical Connection - The electrical installation should be made and maintained by a qualified electrician conforming to national and local codes. A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. A suitable fuse or circuit breaker with properly sized wire must protect the 3- wire power to the fountain. For wiring connections, see wiring diagram. WARNING: DISCONNECT POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN EXTENDED AMOUNT OF TIME. FAILURE TO TURN OFF POWER CAN RESULT IN DAMAGE TO THE WATERING FOUNTAIN. WARNING: THIS INSTALLATION MUST BE MADE AND MAINTAINED IN STRICT CONFORMITY WITH NATIONAL/LOCAL PLUMBING CODES AND NATIONAL/LOCAL ELECTRICAL CODES (CSA IN CANADA). THE APPLICABLE PROVISIONS OF THESE CODES TAKE PRECEDENT. FAILURE TO MAKE AND MAINTAIN ALL INSTALLATIONS PROPERLY MAY RESULT IN LOSS OF LIVESTOCK, PERSONAL INJURY, OR DEATH. NOTE: National/Local electrical codes may require livestock waterers installed in feedlots in open feeding area to be grounded by a separate stranded copper grounding conductor or at least no.6 AWG terminating at a point where the branch circuit receives its supply. Check with local inspecting authorities. CattleMaster Series Instruction Manual 3 October 31, 2016

WIRING DIAGRAM 120V SINGLE PHASE WIRING DIAGRAM 240V SINGLE PHASE CattleMaster Series Instruction Manual 4 October 31, 2016

N. Float Adjustment Open water-supply shut-off valve, check for and fix any leaks. Adjust float for a water depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew. With the valve functioning properly and the water level set at the proper level, you may install the valve cover. The water seal groove between the frame and valve cover must be filled with liquid to create a protective seal from cold winter air getting to the valve. O. Cable Heater Uncoil cable heater and loop around the valve. Attach the remaining part of the cable heater to the water supply, as far down the riser tube as possible with the cable twist ties provided. This heater is water tight, but should not be immersed in water. Heater may cross over itself, but should not be tightened at those locations. CAUTION: Installation must not cause any strain on heater wiring connections. Avoid heater damage caused by hot spots due to its leads lying close to each other. Also, do not wrap additional insulation around heater. P. Install Side Access Panel Once all water line connections have been checked for leaks and electrical hook-up is complete, the side access door may be installed. Q. Children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. R. Cleaning Your Fountain To clean your watering fountain you will need a good stiff bristled brush. Remove the cover then brush the water seal groove to remove any build-up then brush the tank. Remove the plug that is located at the end of the trough to drain out the water and debris. You can shut off the water with the shutoff valve located under the unit or by holding the float in the up position. After the water and debris has drained reinstall the plug and let the tank refill. Now is a good time to readjust the float if needed. Reinstall cover and you are done. CattleMaster Series Instruction Manual 5 October 31, 2016

Ritchie Valves Ritchie valves come in two sizes and three pressure ratings green for high supply line pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the size of trough also impacts valve choice. Although different pressure rated valves may be used in a fountain, each fountain will only accommodate one size and configuration of valve. Your individual situations may require a change from the standard valve supplied with your fountain, see your Ritchie Dealer if this is needed. 3/4 Part # GPM Pressure Range White 16697 33 Low, 5-40 psi (34-275 kpa) Red 11101 20 Moderate, 40-60 psi (275-414 kpa) Green 15377 16.5 High, 60-80 psi (414-552 kpa) NOTE: Maximum inlet water pressure for each valve is shown above. If water pressure is extremely high, and if the valve does not shut off, a pressure-reducing valve may be needed. Product Specifications Product Name CM480 CM480 CM10T CM1440 Part # 18248 18235 18700 18252 Drink Height - in/cm 16/41 16/41 25/64 16/41 Width - in/cm 23.5/59.7 23.5/59.7 32/81 23.5/59.7 Length - in/cm 51/129.5 86/218.4 120/305 146/370 Shipping Weight - lbs/kg 90/41 123/56 235/107 186/84 Operating Capacity - gal/liter 20/76 35/133 50/189 60/227 Herd Capacity - head 200 beef, 100 dairy 300 beef, 150 dairy 400 beef, 200 dairy 475 beef, 240 dairy CattleMaster Series Instruction Manual 6 October 31, 2016

8 22 CattleMaster 480 Part # 18248 1 15 2 9 4 10 14 16 18 17 20 7 11 12 13 3 5 21 6 19 Item Part # Description Qty Item Part # Description Qty 1 18428 CM Cover 1 15 11514 Valve Bracket 3/4" pkg 1 pkg 2 18349 CM Frame pkg 1 pkg 16 15377 Green Male Valve 3/4" pkg 1 pkg 18350 CM Cover & Frame pkg 1 pkg 17 18314 Float with Hardware pkg 1 pkg 3 18250 CM 480 Casing 1 18313 Hardware for Float pkg 1 pkg 4 16780 CM 480 Trough pkg 1 pkg 18 16993 Green Valve & Float pkg 1 pkg 5 16621 Access Panel 6"x14" 2 19 18318 Bolt Down Washer (4/pkg) 2 pkg 6 18147 Access Panel Hardware pkg 2 pkg 20 17679 CM Bulkhead fitting 2" 1 7 16534 Fenwal Thermostat SS pkg 1 pkg 21 18653 Ritchie Decal 12" (1/pkg) 1 pkg 18320 O-Ring Fenwal (6/pkg) 1 pkg 22 17281 Plug #3 - Water Channel (2/pkg) 1 pkg 18074 Nut Brass Fenwal (6/pkg) 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 8 18266 Frame Bolt & Wshr SS(3/pkg) 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 9 18265 Trough Bolt & Nut SS (5/pkg) 1 pkg NS 18329 CM 480 Accessory pkg 1 pkg 10 18338 CM Drain Plug pkg 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 2 11 11419 Heater 120V 250W (1/pkg) 2 pkg 12 17678 Drain Elbow Fitting 1 18251 CM 480 240V 13 17677 Drain Tube 10" 1 NS 11403 Heater 240V 300W (1/pkg) 2 pkg 14 18181 CM Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg CattleMaster Series Instruction Manual 7 October 31, 2016

CattleMaster 840 Part # 18235 15 16 18 1 14 17 8 22 2 9 4 10 20 7 11 12 3 13 6 21 5 19 Item Part # Description Qty Item Part # Description Qty 1 18428 CM Cover 1 15 11514 Valve Bracket 3/4" pkg 1 pkg 2 18349 CM Frame pkg 1 pkg 16 15377 Green Male Valve 3/4" pkg 1 pkg 18350 CM Cover & Frame pkg 1 pkg 17 18314 Float with Hardware pkg 1 pkg 3 18240 CM 840 Casing 1 18313 Hardware for Float pkg 1 pkg 4 16786 CM 840 Trough pkg 1 pkg 18 16993 Green Valve & Float pkg 1 pkg 5 16621 Access Panel 6"x14" 2 19 18318 Bolt Down Washer (4/pkg) 2 pkg 6 18147 Access Panel Hardware pkg 2 pkg 20 17679 CM Bulkhead fitting 2" 1 7 16534 Fenwal Thermostat SS pkg 1 pkg 21 18653 Ritchie Decal 12" (1/pkg) 1 pkg 18320 O-Ring Fenwal (6/pkg) 1 pkg 22 17281 Plug #3 - Water Channel (2/pkg) 1 pkg 18074 Nut Brass Fenwal (6/pkg) 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 8 18266 Frame Bolt & Wshr SS(3/pkg) 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 9 18265 Trough Bolt & Nut SS (5/pkg) 1 pkg NS 18331 CM 840 Accessory pkg 1 pkg 10 18338 CM Drain Plug pkg 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 2 11 11419 Heater 120V 250W (1/pkg) 4 pkg 12 17678 Drain Elbow Fitting 1 18243 CM 840 240V 13 17677 Drain Tube 10" 1 NS 11403 Heater 240V 300W (1/pkg) 3 pkg 14 18181 CM Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg CattleMaster Series Instruction Manual 8 October 31, 2016

CattleMaster 10T Part # 18700 1 15 16 18 2 14 17 22 9 8 4 7 10 20 11 12 3 13 5 21 6 19 Item Part # Description Qty Item Part # Description Qty 1 18428 CM Cover 1 15 11514 Valve Bracket 3/4" pkg 1 pkg 2 18349 CM Frame pkg 1 pkg 16 15377 Green Male Valve 3/4" pkg 1 pkg 18350 CM Cover & Frame pkg 1 pkg 17 18314 Float with Hardware pkg 1 pkg 3 18698 CM 10T Casing 1 18313 Hardware for Float pkg 1 pkg 4 18697 CM 10T Trough 1 pkg 18 16993 Green Valve & Float pkg 1 pkg 5 16562 Access Panel 10"x20" 2 19 18318 Bolt Down Washer (4/pkg) 2 pkg 6 18147 Access Panel Hardware pkg 2 pkg 20 17679 CM Bulkhead fitting 2" 1 7 16534 Fenwal Thermostat SS pkg 1 pkg 21 18653 Ritchie Decal 12" (1/pkg) 1 pkg 18320 O-Ring Fenwal (6/pkg) 1 pkg 22 17281 Plug #3 - Water Channel (2/pkg) 1 pkg 18074 Nut Brass Fenwal (6/pkg) 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 8 18266 Frame Bolt & Wshr SS(3/pkg) 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 9 18265 Trough Bolt & Nut SS (5/pkg) 1 pkg NS 18331 CM 10T Accessory pkg 1 pkg 10 18338 CM Drain Plug pkg 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 2 11 11419 Heater 120V 250W (1/pkg) 4 pkg 12 17678 Drain Elbow Fitting 1 18701 CM 10T 240V 13 17677 Drain Tube 10" 1 NS 11403 Heater 240V 300W (1/pkg) 3 pkg 14 18181 CM Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg CattleMaster Series Instruction Manual 9 October 31, 2016

CattleMaster 1440 Part # 18252 22 1 2 14 15 16 18 17 8 9 4 10 7 20 3 11 12 13 5 21 6 19 Item Part # Description Qty Item Part # Description Qty 1 18428 CM Cover 1 15 11514 Valve Bracket 3/4" pkg 1 pkg 2 18349 CM Frame pkg 1 pkg 16 15377 Green Male Valve 3/4" pkg 1 pkg 18350 CM Cover & Frame pkg 1 pkg 17 18314 Float with Hardware pkg 1 pkg 3 18659 CM 1440 Casing 1 18313 Hardware for Float pkg 1 pkg 4 16791 CM 1440 Trough pkg 1 pkg 18 16993 Green Valve & Float pkg 1 pkg 5 16621 Access Panel 6"x14" 3 19 18318 Bolt Down Washer (4/pkg) 3 pkg 6 18147 Access Panel Hardware pkg 3 pkg 20 17679 CM Bulkhead fitting 2" 1 7 16534 Fenwal Thermostat SS pkg 1 pkg 21 18653 Ritchie Decal 12" (1/pkg) 1 pkg 18320 O-Ring Fenwal (6/pkg) 1 pkg 22 17281 Plug #3 - Water Channel (2/pkg) 1 pkg 18074 Nut Brass Fenwal (6/pkg) 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 8 18266 Frame Bolt & Wshr SS(3/pkg) 1 pkg NS 13830 Cable Htr 120V 48W (1/pkg) 1 pkg 9 18265 Trough Bolt & Nut SS (5/pkg) 2 pkg NS 18333 CM 1440 Accessory pkg 1 pkg 10 18338 CM Drain Plug pkg 1 pkg NS 14866 Seal Foam 1/2"x3/4"x10' Roll 3 11 11419 Heater 120V 250W (1/pkg) 5 pkg 12 17678 Drain Elbow Fitting 1 18255 CM 1440 240V 13 17677 Drain Tube 10" 1 NS 11403 Heater 240V 300W (1/pkg) 3 pkg 14 18181 CM Standpipe pkg 1 pkg NS 16424 Cable Htr 240V 48W (1/pkg) 1 pkg CattleMaster Series Instruction Manual 10 October 31, 2016

Problem Water in Trough Too Warm Ice in Trough Valve Freezing Supply line Freezing Valve won t stop dripping Low water flow Trouble Shooting Solution Adjust thermostat to lower temperature Check to see if thermostat has failed by contacts burning closed Check fuses or circuit breakers Check all heating elements to make sure they are working and hot Adjust thermostat to higher temperature Check for voltage from thermostat output Check voltage to fountain with and without electrical load Check that heaters are wired properly Check that cable heater is installed properly and fastened to water supply line and is working when heaters are hot Check for missing or damaged insulation Check for air gaps for wind penetrations Check that the cable heater is uncoiled and fastened around valve, to supply line and is working when heaters are hot Check that supply piping is centered in riser tube Check that riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between casing and concrete floor Check float adjustment. Check for waterlogged float, or float rubbing on side of valve compartment Disassemble valve and check for 3/4 Valve: sand or scale in valve rubber. Also check valve orifice outlet for wear and damage. A screen or filter my be required with sandy or scaly water Turn valve rubber over and reassemble Valve Rubber Check for excessive water system pressure Check that valve inlet is not plugged or supply hose is not kinked Check system pressure from supply hose by installing a tee and a pressure gauge directly in front of the valve to check pressure drop when valve is open. A severe pressure drop indicates a restriction or undersized supply system. Check that shutoff valves are fully open CattleMaster Series Instruction Manual 11 October 31, 2016

Ritchie Limited Warranty Eff ective S ep temb er 2012 Ritchie Industries, Inc. warrants its products to be free of defective materials and workmanship. Defective part(s) will be repaired or replaced at the option of Ritchie Industries. This warranty specifically excludes all labor and shipping charges. This warranty does not apply to any appearance items, to any product whose exterior has been damaged or defaced, to any product that has been improperly installed, to any product subjected to misuse, abnormal service or handling, and to any products altered or repaired with other than original equipment or manufacturer s parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. All warranty claims must be processed through an Authorized Ritchie Dealer/ Distributor. Proof of purchase is required. This warranty is not transferable. The period of warranty begins at original date of purchase as follows: Poly Units Base, top and ball closures 10 year limited against manufacturing defect. 100% first five years, then declining 20% per year for the remaining five years. Stainless Steel Units Stainless trough and stainless valve chamber frame: Ten years against manufacturing defect or corrosion. 100% all ten years. Casing and cover: 10 year limited against manufacturing defect. 100% first year, then declining 10% per year for the remaining nine years. Component Parts All component parts, such as floats, valves, heating elements: One year from the date of purchase against manufacturing defect, 100%. CattleMaster Series Instruction Manual 12 October 31, 2016