T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Similar documents
T8090A/Q682B Heating, Cooling, and Heating-Cooling Thermostat, Wallplate and Subbase

T874 Multistage Thermostat and Q674 Subbase

T834C Heating-Cooling Thermostat

Home and Building Control Home and Building Control Helping You Control Your World

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Y8196A (T8196A Thermostat/ Q682A Subbase) Heating/Cooling New Construction Thermostat/Subbase Package Installation Instructions

T8411R Electronic Heat Pump Thermostat

T7200D,E Series 2000 Commercial Microelectronic Thermostats

CT1500, CT1501, CT1502, CT1503

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8600D Chronotherm IV Deluxe Programmable Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

CT500 Electronic Thermostat

T8034C Heating/Cooling Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats

Oil-Fired Furnace Single Stage Heat Pumps No- Auxiliary Heat. Electric Air Conditioning

Deluxe Programmable Thermostats

T8401C Electronic Thermostats

T8195B/Q682B,C, Y8224A Heating or Cooling and Heating/Cooling New Construction Thermostat, Wallplate and Subbase

T8112C,DElectronic ProgrammableThermostats

T4398A,B High Performance Electric Heat Thermostats

Deluxe Programmable Heat Pump Thermostat T8611M

T4098A,B Deluxe Electric Heat Thermostats

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

CT2700 An Electronic Round Programmable Thermostat

Commercial Touchscreen Thermostat

T8011R Programmable Heat Pump Thermostat

T4398A,B Precision Electric Heating Thermostat

TP970 Series CONVERTASTAT Kits

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

Q7300L Series 2000 Commercial Thermostat Subbases

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

MagicStat CT3300 Programmable Thermostat

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

The T6140A,B Remote Bulb Temperature Controller

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

CT2800 Programmable Thermostat

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

T8524 Deluxe Electronic Thermostat

ACONT600AF11MA Programmable Comfort Control

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Q7300H Series 2000 Commercial Thermostat Subbases

tcu.z Commercial Programmable Thermostat Installation Instructions

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

TCONT602AF22MA. Programmable Comfort Control. Installation Instructions 18-HD37D1-1

Operator: Save these instructions for future use!

T8132C Programmable Thermostats

T6984F,G Electronic Floating Control Thermostats

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

T874R Thermostats and Q674L Subbases

CAUTION: ELECTRICAL HAZARD

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Operator: Save these instructions for future use!

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Operator: Save these instructions for future use!

ELECTRONIC COMMUNICATING THERMOSTAT

heat (2 heat/1 cool).

T-32-TS Touchscreen Thermostat. Installation Manual

T7984 A,B,C Electronic Modulating Control Thermostats

T7100D Microelectronic Conventional Thermostat

T8112 Programmable Thermostat

Honeywell/36. Programmable Thermostat OWNER S GUIDE

REMOVING OLD THERMOSTAT DETAILS. Model No CONTENTS YOUR THERMOSTAT REPLACES 0 PREPARATIONS. 5/2 Day Programmable Thermostat

Comfort System T-21-P Touchscreen Thermostat Installation Manual

1F60-22 INSTALLATION & OPERATING MANUAL SETBACK THERMOSTAT. Homeowner: Save this booklet for future use!

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

Safety & Installation Instructions

CT1001/CT1002 Touchscreen Programmable Thermostat

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Operator: SaVe these instructions forfuture use

Q7100A,C,D Thermostat Subbases

T8000C Programmable Thermostat

T7079A,B Solid State Remote Temperature Controllers

Safety & Installation Instructions

Operator: Save these instructions for future use!

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Emerson Blue Easy Set 1H/1C

Must be installed by a trained, experienced technician

Commercial/Industrial Combustion Control Level Three Announcement

1 PREPARATIONS 2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT. 1E78 Non-Programmable Thermostat CONTENTS

Honeywell/20 Programmable Thermostat

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

Detailed Installer Guide

Y594 (Multistage Thermostat Subbase) Package

IF78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Safety & Installation Instructions

Safety & Installation Instructions

Smart Temp. Model

Honeywell CT3611 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

Transcription:

M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B Subbase separately. Check thermostat and subbase (if used) suitability for the heating, cooling, or heating/cooling system. Refer to Table. Assemble tools required: flat-bladed screwdriver, hand or power drill with 3/6-in. drill bit, wire cutter/stripper or sharp knife, bubble level or plumb bob and line. Assure power is off to the heating, cooling, or heating/ cooling system at the main fuse panel. Most buildings have a separate switch box or circuit breaker for disconnecting power to the heating and cooling (if applicable) equipment. This thermostat is compatible with all heating, cooling or heating/cooling systems when thermostat is powered by batteries. If thermostat is not powered by batteries, refer to Table for thermostat and system compatibility information. Recycling Notice This control contains mercury in a sealed tube. Do not place control in the trash at the end of its useful life. If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of this control, or of an old control containing mercury in a sealed tube. If you have questions, call Honeywell Inc. at -800-468-50. TABLE SYSTEM COMPATIBILITY FOR NON-BATTERY POWERED S. Type of Heating System to be Controlled Conditions/Compatibility Electric (Line Voltage) typical baseboard and radiant Fan Coil Unit Gas Direct Spark Ignition (DSI), Intermittent Pilot (IP), and Standing Pilot (SP) Heat Pump Hot Water Zone Oil Vent Damper The R839D05 Isolating Relay or R84 Silent Switching Center must be installed in the thermostat control circuit. a Compatible. Assure correct subbase identity is selected for fan control. Compatible. If not using battery backup, assure that 4V control transformer common is accessible for connection to thermostat cable conductor and power to the transformer is not regularly interrupted by high temperature or limit operation. Compatible. Assure correct subbase identity is selected for fan control and changeover control (O terminal for cool and B terminal for heat). Honeywell -wire valves are compatible. Some non-honeywell -wire valves require an R839D05 Isolating Relay in the thermostat control circuit. a Some 3-wire valves require an R839A05 Isolating Relay in the thermostat control circuit. a, b If not using battery backup, assure that the 4V control transformer common is accessible for connection to thermostat cable conductor and power to the transformer is not regularly interrupted by high temperature, purge cycle, or limit operation. Honeywell damper motors are compatible. Some non-honeywell damper motors require an R839D05 Isolating Relay in the thermostat control circuit. a Check control amperage requirement. Warm Air Zone Most are compatible. a If thermostat is not compatible with the system being controlled, the system will not operate. No hazard exists. The thermostat will not be damaged unless it is used to directly control a line voltage system. For proper system operation, a Honeywell R84 or R839D05 Isolating Relay must be added to the thermostat control circuit. b Consult manufacturer for installation requirements. D.F. Rev. -94 Honeywell Inc. 994 Form Number 69-064

9 9 8 Installation WHEN INSTALLING THIS PRODUCT. Read these instructions carefully. Failure to follow them could cause a hazardous condition.. Installer must be a trained experienced service technician. 3. After installation is complete, check out product operation as provided in these instructions. IMPORTANT: An incorrectly leveled subbase will cause the temperature control to deviate from setpoint. It is not a calibration problem. CAUTION. Disconnect power supply to prevent electrical shock or equipment damage.. To prevent interference with the thermostat linkage, keep wire length to a minimum and run wires as close as possible to the subbase. 3. Do not overtighten thermostat captive mounting screws because damage to subbase threads can result. 4. Do not short across coil terminals on relay. This can burn out the thermostat heat anticipator. LOCATION Locate thermostat about 5 ft [.5m] above the floor in an area with good air circulation at average temperature. Do not mount the thermostat where it may be affected by: drafts, or dead spots behind doors and in corners. hot or cold air from ducts. radiant heat from the sun or appliances. concealed pipes and chimneys. unheated (uncooled) areas such as an outside wall behind the thermostat. Run wires from the heating, cooling or heating/cooling equipment to the new thermostat location. Refer to the Typical Wiring Diagrams section to determine the number of wires required for your application. UNPACK Handle your new thermostat carefully; rough handling may interfere with its accuracy. Before unpacking, refer to Fig.. Remove and discard the shipping wrap. IMPORTANT: Save package of screws and instructions for the homeowner. Remove the thermostat cover by lifting from the bottom. Set aside cover until needed later. Carefully remove the material protecting the mercury switch bulb. Loosen two captive mounting screws and separate wallplate (if provided) from back of thermostat base. Fig. Unpack thermostat. LIFT COVER BASE CAPTIVE MOUNTING SCREWS 8 7 6 0 5 4 3 0 6 7 35 30 5 0 0 COVER REMOVE PACKING MATERIAL M8673 MOUNT WALLPLATE OR SUBBASE Wall Mounting (Fig. ) Hold the wallplate or subbase in position on wall (Fig. ). Mark holes on the wall for anchors. Use spirit level to make sure the wallplate or subbase is level. Drill 3/6-in. holes, and gently tap anchors into holes until flush with the wall. Pull wires through the large wiring hole in the wallplate or subbase. Loosely fasten the wallplate or subbase to the wall with the three screws. Do not completely tighten the screws. Carefully level the wallplate or subbase (Fig. 3), and firmly tighten the screws. Fig. Mounting wallplate or subbase to wall. 3 SCREW HOLES WITH PLASTIC ANCHORS 3 SCREW HOLES WITH PLASTIC ANCHORS WALLPLATE O B R W G Y FAN COOL ON AUTO OFF ING/COOLING SUBBASE M55A M85 69-064

G R Y W O B Fig. 3 Leveling methods for wallplate or subbase. PLUMB LINE PLUMB BOB OR WEIGHT FAN ON R G AUTO O SPIRIT LEVEL Y B W OFF COOL M555 Outlet Box Mounting (Fig. 4) Use a horizontally mounted outlet box if possible. If a vertical outlet box is used, mount the wallplate or subbase on a 93A (beige) Cover Plate Assembly (ordered separately). Follow the instructions provided with the cover plate assembly. Align the wallplate or subbase mounting holes on the outlet box and loosely fasten with two screws. Carefully level the wallplate or subbase (Fig. 3), and firmly tighten the screws. WIRE WALLPLATE OR SUBBASE Follow the instructions provided by the heating, cooling, or heating/cooling equipment manufacturer. If not available, refer to the Typical Wiring Diagrams section at the end of this publication. Disconnect the power supply before making wiring connections to prevent electrical shock or equipment damage. Fig. 4 Mounting wallplate or subbase on horizontal outlet box. EXISTING HORIZONTAL OUTLET BOX EXISTING HORIZONTAL OUTLET BOX O R B R G Y W ING/ COOLING SUBBASE W WALLPLATE FAN ON AUTO OFF COOL M86 M553A VERTICAL OUTLET BOX ADAPTER RING COVER PLATE SUBBASE OR WALLPLATE NOT INCLUDED WITH UNIT. ACCESSORY PARTS AVAILABLE. MOUNTING SCREWS () M554A NOTE: All wiring must comply with local electrical codes and ordinances. This thermostat clock can be powered by a 4 Vac transformer with battery backup. Refer to Figs. 5 through 9 for hookup diagrams of typical powering applications. For Wallplate (Heating or Cooling Systems) Refer to Fig. 5 and strip the thermostat wire insulation as necessary. For heating-only systems, connect wires to R, W, and C (if applicable) terminals (Fig. 0). For cooling-only systems, connect wires R, Y, and C (if applicable) terminals. Firmly tighten the screws. 3 69-064

9 9 8 Push excess wire back into the wall. Plug the hole in the wall with nonhardening caulk, putty, or nonflammable insulation to prevent drafts from affecting thermostat operation. Subbase (Heating/Cooling Systems) Refer to Fig. 5 and strip the thermostat wire insulation as necessary. Connect the wires to the corresponding terminals on the subbase. If labels do not agree with your new subbase, refer to Table and the installation instructions furnished with the subbase. NOTE: If wiring a dual transformer system, only the O or the B terminal may be used. Push excess wire back into the wall. Plug the hole in wall with nonhardening caulk, putty, or nonflammable insulation to prevent drafts from affecting the thermostat operation. Fig. 5 Methods of connecting terminals. FOR STRAIGHT CONNECTION STRIP 5/6 in. [8 mm] FOR WRAPAROUND CONNECTION STRIP 7/6 in. [ mm] BARRIER M556B Subbase Terminal R R c R h W Y G C O B P TABLE SUBBASE TERMINAL DESIGNATIONS. Control Function Control transformer power. Line side of 4V power supply; cooling side, transformer heat/cool system. Line side of 4V power supply; heating side, transformer heat/cool system. Heating control circuit. Cooling control circuit; jumper to W for heat pump compressor control if no P terminal on subbase. Fan control circuit. Clock control (transformer common). Cooling damper or changeover/reversing valve, makes continuously in cool. Heating damper or changeover/reversing valve, makes continuously in heat. Heat pump contactor; P terminal on some models only. MOUNT THE Note the tabs on the top inside edge of the thermostat base. These tabs fit the slots molded into the top of the wallplate or subbase. Hang the thermostat base on the wallplate or subbase. Insert the two captive mounting screws located in the bottom corners of the base (Fig. 6). Firmly tighten the screws. INSERT BATTERIES Power is supplied to the clock by the 4 Vac transformer or two AAA alkaline batteries (included), or by the heating or cooling control circuit. Backup batteries may be installed to supply power to the clock if power is interrupted when using 4 Vac powering method. Install the batteries in the thermostat (Fig. 7). Once a year or when batteries are dead, replace with two new AAA alkaline batteries. Properly dispose of old batteries. We recommend Energizer batteries. Fig. 6 Thermostat mounting. 8 7 6 0 5 4 3 TAB () MOUNTING SLOT () 0 6 7 35 30 5 0 0 BASE WALLPLATE OR SUBBASE CAPTIVE MOUNTING SCREWS M8674 69-064 4

Fig. 7 Insert timer batteries. Fig. 8 Set timer. BATTERY LOCATION FOR () AAA BATTERIES; INSTALL WITH POSITIVE ENDS UP PROGRAM DIAL PROGRAM PIN (6) SETTING KNOB TIME INDICATOR ARROW M8585 SET Adjust the timer by moving the knob clockwise. Do not reverse the knob. When time is correctly set, the time indicator arrow (triangle shape) points to the correct time and the corresponding daytime (light) or nighttime (dark) portion of the program dial (Fig. 8). M8A Let the system operate for one minute. Adjust the heat anticipator lever to match the number that reads on the ammeter. SET Adjust the heat anticipator lever to match the current rating of the primary control for the proper cycle rate (Fig. 9). Adjustable anticipation must be set for total current of heat and fan control. The current rating is usually stamped on the control or valve (Fig. 0), or a setting may be given in the device instructions. If no current rating or heat anticipator setting is given, measure the current with an ammeter. Proceed with the following steps. Remove the thermostat from the wallplate or subbase. Connect an ac ammeter of appropriate range (about 0A to A) between the R and W terminals on the wallplate or subbase, except for electric heat and heat pump systems. Fig. 9 Adjust heat anticipator. SCALEPLATE SETTING LEVER M737 Fig. 0 Current rating of primary control. OIL BURNER CONTROL SHOWS VOLTAGE RATING SHOWS SETTING 8406 V8043E 004 4 4V 50/60CY.3 AMP @ 60CY SHOWS CURRENT DRAW 30 VAC 0. AMP SHOWS LOW VOLTAGE SHOWS VOLTAGE RATING 4 Vac 50/60 Hz TO BURNER T T F F ZONE VALVE FROM MAIN FUEL SUPPLY 0.4 AMP TYPICAL GAS VALVE SHOWS SETTING M66A 5 69-064

ATTACH COVER Make sure the packing inserts in the thermostat base are removed. Place the two tabs on the upper edge of the cover into the mounting slots in the thermostat base (Fig. ). Swing the cover downward until it catches at the bottom of the base. Fig. Attach cover. To switch positions, use thumb or index finger to slide lever to the desired position. Switch lever must stop in detent over the desired function indicator mark for proper circuit operation. Checkout CAUTION Do not check operation by shorting across the terminals of the system controls. This will damage the heat anticipator. 50 60 70 80 M8604 SET TEMPERATURE CONTROL LEVERS The two levers on the top of the thermostat control the low and high temperatures for energy savings and comfort control (Fig. ). The lever on the left (blue mark) controls the lower temperature. The lever on the right (red mark) controls the higher temperature. We recommend pushing the levers together at an appropriate temperature for either heat or cool until the occupant programs the thermostat and makes the final temperature selections. ING-ONLY SYSTEM Turn on power to the furnace. Push both temperature setting levers together at least 5 F [3 C] above the room temperature. The main burner should come on. The fan will start when the furnace heats up. Move both levers 5 F [3 C] below the room temperature. The burner should shut off. Operate the entire heating system at least one complete cycle. If thermostat fails any test, refer to the Troubleshooting Guide in the Owner s Manual. Reset both temperature setting levers to the desired temperatures. COOLING-ONLY SYSTEM Turn on power to the cooling equipment. Push both temperature setting levers together at least 5 F [3 C] below the room temperature. The cooling equipment will operate, and the fan will start. Allow for any time delay that may be built into the compressor control circuit. Fig. Temperature control levers. LOW TEMPERATURE (BLUE MARK) SET LEVER 50 60 70 80 HIGH TEMPERATURE (RED MARK) SET LEVER M859 SET SUBBASE SWITCHES (IF APPLICABLE) The subbase system switch controls system operation as follows: : Heating system is controlled by the thermostat. Cooling system is off. COOL: Cooling system is controlled by the thermostat. Heating system is off. OFF: Both the heating and cooling systems are off. If the fan switch is in the AUTO position, the fan is also off. The subbase fan switch controls fan operation as follows: ON: Fan operates continuously. AUTO: Fan operates with the cooling equipment as controlled by the thermostat or with the heating equipment as controlled by the plenum switch. In electric heat, heat pump, and fan coil systems, the fan is controlled by the thermostat in heating and cooling. NOTE: To avoid compressor damage, do not operate the system when outdoor temperature is below 50 F [0 C]. Refer to manufacturer recommendations. Move both levers 5 F [3 C] above room temperature. The cooling equipment and the fan should shut off. Operate the entire cooling system at least one complete cycle. If thermostat fails any test, refer to the Troubleshooting Guide in the Owner s Manual. Reset both temperature setting levers to the desired temperatures. ING/COOLING SYSTEM Turn on power to the furnace and cooling system. Place the system switch lever to and fan switch lever to AUTO. Push both temperature setting levers together at least 5 F [3 C] above room temperature. The main burner should come on. The fan will start when the furnace heats up. (If central electric heat, fan coil or heat pump system, fan starts immediately.) Move both levers 5 F [3 C] below room temperature. The burner should shut off. Place the system switch lever to COOL and the fan switch lever to AUTO. The cooling equipment will operate, and the fan will start. Allow for any time delay that may be built into the compressor control circuit. 69-064 6

NOTE: To avoid compressor damage, do not operate the system when outdoor temperature is below 50 F [0 C]. Refer to manufacturer recommendations. Move both temperature setting levers together at least 5 F [3 C] above the room temperature. The cooling equipment should shut off. Place the fan switch to ON. The fan should run continuously with the system switch in any position. Place the system switch to OFF. Move both temperature setting levers to various positions. The heating and cooling systems should not operate. Operate the entire system for at least one complete cycle with the system switch at COOL and one complete cycle with the switch at. If thermostat fails any test, refer to the Troubleshooting Guide in the Owner s Manual. Reset both temperature setting levers to the desired temperatures. Leave Owner s Manual and Assistance Information in a convenient place for the building occupant or provide with other appliance manuals. Fig. 3 Thermometer calibration. INCREASE M58 Calibration THERMOMETER The thermometer in your thermostat was accurately calibrated at the factory. The thermometer should need adjustment only if it has been dropped or shifted due to mishandling. If the setpoint lever and the thermometer reading do not agree:. Remove the thermostat cover by pulling up from the bottom of cover until it clears the mounting slots.. Set the thermostat cover on a table near an accurate thermometer. 3. Allow five minutes for cover thermometer to sense area temperature; compare the readings. Be careful not to touch thermometer or breathe on it. 4. If the readings are the same, replace cover and put the system into operation. 5. If the readings are different, insert a small screwdriver in the thermometer and turn it until the thermometers have the same reading (Fig. 3). 6. Replace thermostat cover and put the system into operation. NOTE: Radiant heat from your hands will offset the thermometer reading. After making each adjustment, wait five or ten minutes for the thermometer to stabilize before comparing. This thermostat was calibrated at the factory and should not need recalibration in the field. If recalibration seems necessary, first be sure wallplate or subbase is accurately leveled. Then check thermometer calibration. To check thermostat calibration, allow several hours of operation after installation. Then read thermometer and remove cover. Push temperature levers together to a setting below room temperature. Slowly move them up the scale together until the mercury slides across the tube. If the thermometer reading and the high temperature lever position are approximately the same at the instant the mercury moves to the other end, no recalibration is needed. If calibration is necessary, proceed as follows:. Remove the cover.. Place open-end calibration wrench, part no. 04994A (ordered separately), on the hex nut under the bimetallic coil controlled by the red lever (Fig. 4). Hold lever so it does not move, and gently turn the wrench clockwise until the mercury rests securely in the right end of the tube. 3. Put the thermostat cover on and wait ten minutes. 4. Read the thermometer. Then remove the cover. Moving both levers, place the HIGH lever at the thermometer reading. Hold lever so it does not move, and gently turn the wrench counterclockwise until the mercury just slides to the left end of the tube but no farther. Try to do this quickly so the heat from your hands does not affect the thermostat. 5. Repeat this procedure for the blue lever. Fig. 4 Use of 04994A calibration wrench. CALIBRATION WRENCH SETTING LEVER SCALEPLATE.35.30.5.0.0 M8583 7 69-064

Typical Wiring Diagrams Fig. 5 Typical hookup for timer powered by separate 4-Vac transformer. Fig. 7 Typical hookup for timer powered by system transformer. Timer powered by battery when system is not powered (e.g., power to system is off or interrupted). BATTERY BATTERY SUBBASE C C R W SUBBASE L L L L C C R W RELAY L L RELAY POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M84A POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. BATTERY BACKUP MAY BE USED IF POWER TO IS INTERRUPTED. M8A Fig. 6 Typical hookup for timer powered by two AAA alkaline batteries only. Fig. 8 Typical hookup for timer powered through control system. Timer powered by battery when heating or cooling equipment is on; timer takes power from system when heating equipment is off. BATTERY BATTERY SUBBASE L L C C R W RELAY POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M83A SUBBASE L L 3 C C RH RC W Y L L RELAY COMPRESSOR CONTACTOR POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. JUMPER RH-RC TERMINALS WHEN ONE TRANSFORMER POWERS BOTH ING AND COOLING. 3 FOR POWER STEALING ON ING, JUMPER C-RH AND C-W TERMINALS. M85A 69-064 8

Fig. 9 Typical hookup for timer powered through control system. Timer powered by battery when heating or cooling equipment is on; timer takes power from system when cooling equipment is off. BATTERY SUBBASE L L 3 3 C C RH RC W Y L L RELAY COMPRESSOR CONTACTOR POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. JUMPER RH-RC TERMINALS WHEN ONE TRANSFORMER POWERS BOTH ING AND COOLING. FOR POWER STEALING ON COOLING, JUMPER C-RC AND C-Y TERMINALS. M86A Fig. 0 Internal schematic and typical hookup for T890A Thermostat/908AJ Wallplate in heatingonly system. H H FALL C FALL C WALLPLATE C C R W Y L L RELAY POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M87A 9 69-064

69-064 0

69-064

Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited Honeywell Limitée 985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 554 Scarborough, Ontario MP V9 QUALITY IS KEY Printed 69-064 in Mexico