The SigniFire IP Camera System is capable of detecting and alarming on a variety of events. Once an alarm occurs it can be signaled through contact closure or by digital streamed transmissions over IP. Flaming Fires: Looks for a specific fire pattern consisting of a bright core of flam and a flickering corona. Reflected Fire Light: Detects the presence of the flickering component of fire light reflected off surfaces facing the fire. Smoke Plumes: Identifies the anomalies that are caused by smoke and analyzes the progression over a period of time to identify a growing smoke plume. Ambient Smoke: Monitors the light diffusion from light sources and bright objects in the video images to detect the pattern consistent with the slow accumulation of smoke. Intrusion Detection: Can monitor multiple areas of the video image for the presence of moving objects at different times. This can be used to detect and record wanted or unwanted persons. Phone (479) 968-4266 Fax (479) 890-9072 www.i-i-s.net
UL/FM, NFPA compliant flame and smoke detection Permanent or Temporary unmanned fire watch Integrate alarm signals and video with existing Video Management Systems Steam leak detection Remote video and alarm monitoring Records to network video recorder 24/7 and tracks events NFPA maintenance performed at computer Wireless or wired
ALGORITHMS SENSITIVITY LEVELS SigniFire IP Video Smoke detection camera, combines the enhanced resolution and picture clarity of a standard network camera with built-in fire, smoke and motion detector capabilities. The detection events are instantly reported to the Digital Video Management (DVM) system over a standard network connection and/or communicated directly to the CyberCat Fire Alarm Control Panel through a configurable relay. Each detection algorithm runs independently on the camera. This allows the end user to adjust the sensitivity settings low, medium, high, and ultra (smoke only) or turn off an algorithm altogether. The built in flexibility allows for a wide range of video flame and smoke detection options. DETECTION / EXCLUSION ZONES Each SigniFire IP video flame detection and video smoke detection camera can be configured with multiple detection and/or exclusion zones within the field of view. These zones can be added to do all of the following: detect specific events (fire, smoke and motion) within the zone detect events everywhere except the zone The activation of each zone can also be linked to specific time schedules Examples: setting up a motion detection zone in a hallway to be only active at night and/or weekends, when no one should be in the building. if the area is known for steam release occurring at certain periods of time, a smoke detection exclusion zone can be defined and linked to a schedule when such releases are expected. These detection/exclusion zones, combined with SigniFire s unique algorithm sensitivities, allow for endless configuration options to suit specific fire, smoke and intrusion detection requirements. NETWORK-FRIENDLY SigniFire IP video flame and smoke detection cameras are network devices with their own IP address. Communicating with the camera is easily accomplished with standard TCP/IP networking protocols. This enables the SigniFire solution to scale easily to any size organization. The SigniFire video flame and smoke detection cameras can be monitored anywhere there is network connectivity. Email alerts with snapshots of the event can also be sent to handheld PDA s. FIRE ALARM CONTROL PANEL INTERFACE The SigniFire IP video flame and smoke detection camera can connect directly to a CyberCat Fire Alarm Control Panel as a regular smoke and fire detector via three built-in, dry-contact relays mounted on the back of each camera. The dry contacts can also be easily programmed to include a delay on specific events, to allow video verification before the fire alarm panel is notified helping to eliminate nuisance alarms.
Processor Memory: Imager: Video Format: Video Resolution: Video Compression: UL Minimum Illumination: Events Notification Medium: Detector Performance: Flame: Smoke: Motion: Detection Zones: Dimensions and Weight: Temperature Limits: Power: Video Management Software: Connectors: Lenses available: 128 MB RAM Micron CMOS MT9M11 Color NTSC 640 x 480 (NTSC) MJPEG 1 Foot-candle (10 Lux) http network based communications, Alarm, Trouble and Auxiliary Dry Contacts 1 ft pan fire at 100 ft. indoor detection verified at 100 ft. confirmable motion detection based on zones and schedules User defined, including detect/non-detect logic. Each zone may be linked to multiple detection schedules (daily, weekly, monthly, yearly, single occurrence) 7 x 3.18 x 2 ; 1.5 lbs. 32-120 F (0-49 C) Humidity up to 5-95% non condensed Power over Ethernet (POE); 12 VDC (FM), 12-24 VDC (UL); Consumption < 5 Watts SpyderGuard API available for video management integration RJ-45 Ethernet Jack; Terminal block for three relay outputs and DC power connection; BNC for coaxial analog out. 2.8mm and 8mm lenses
A scalable, network video recorder with video management software, each FSM-IP is designed to support up to 32 SigniFire IP network, flame detecting cameras Constantly records video streams onto internal hard disk Customizable storage space to meet application needs. Provides monitoring of live videos With the scalable FSM-IP, multiple servers can be configured to handle a large number of cameras. This provides the ability to build an enterprise-level surveillance system that can be monitored and configured from one single workstation.
SpyderGuard is our state-of-the-art monitoring, investigative and administrative tool and is designed to seamlessly access multiple FSM-IP servers over an enterprise-wide network or the Internet. The SpyderGuard video flame and smoke detection software provides: live, on-event and on-demand video feeds voice annunciation of alarms with a precise location real-time access to building plans visuals of areas and locations under alarm conditions With SpyderGuard it is easy to search and playback events stored in video archives for forensic analysis of the events leading up to the fire.
SITUATIONAL AWARENESS Each time a fire, smoke and/or motion event is detected by one of the SigniFire IP video smoke detection cameras, SpyderGuard automatically switches to live feed of the event showing real-time footage with an audio description of alarm and location. The situational awareness provided byspyderguard means on-site personnel do not have to constantly monitor the video to know when a fire happens, and it provides instantaneous, relevant information to determine the appropriate course of action.
TIMELINE Statistics show 23% of all non-residential fires are arsons, requiring serious forensic investigations. Traditionally, fire investigators recreate the events that led to a fire by painstakingly collecting the evidence at the scene. SpyderGuard can reduce this process from weeks to just a few hours, through review of all video recordings prior to the event. Depending on the size of storage used,spyderguard allows investigators to view events hours, days and even weeks before the event. SECURITY PEACE OF MIND SpyderGuard combines physical security and early warning fire and smoke detection expanding the functionality of a video security system to protect the assets from accidental as well as intentional fires.