U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Similar documents
86BSD Digital Output

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

DP86 Constant Voltage with Fitting

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

86BSD Digital Output

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

M7100 Pressure Transducer

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

D5100 Industrial Differential Pressure Transducer

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

86BSD Digital Output

89BSD Digital Output

MSP100 Pressure Transducer

Standard SPECIFICATIONS FEATURES APPLICATIONS

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

D5100 Industrial Differential Pressure Transducer

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

MSP340 Pressure Transducer

MS4525 SPECIFICATIONS

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

U5300 Industrial Pressure Transducer

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

FC22 Compression Load Cell

M5200 Industrial Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Sub psi SPECIFICATIONS

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

U5700 Submersible Liquid Level Pressure Transducer

MSP100 Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

MSP300 Pressure Transducer

FC23 Compression Load Cell

M5800 Pressure Transducer with Rotatable Display

P125 High Pressure Sensor

U5600. Wireless Pressure Transducer SPECIFICATIONS

LOW PRESSURE Intrinsically Safe Transducer AST44LP

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

ELAF LOAD CELL SPECIFICATIONS FEATURES

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

The Importance of Pressure Sensors in HVACR Systems

MODEL 4000A & 4001A ACCELEROMETER

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

PT9420 (Extended Range)

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

TS105-10L5.5MM Thermopile Sensor

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

Heavy Duty Pressure Transducers

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

MODEL 834M1 ACCELEROMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

TSYS02S Digital Temperature Sensor

TSEV01S01C10 SPECIFICATIONS

MINIATURE ELECTRONIC PRESSURE SCANNERS ESP-16HD/32HD/64HD

HM1500LF Relative Humidity Module

HM1520LF Relative Humidity Module

15203B 25203B 35203B Uniaxial Biaxia Triaxial

Cable Actuated Sensor Industrial User Scalable 4 20mA

OPERATION MANUAL MODEL & ACCELEROMETER

Cable Actuated Sensor Industrial User Scalable VDC Output

PT9600. Cable Actuated Encoder Reel. General. Environmental

CABLES AND ACCESSORIES FOR TRUBLUE DATA LOGGERS

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

Cable Actuated Sensor Industrial Incremental Encoder Output

LMM-H03 Mass Air FLow Sensor

OPERATION MANUAL MODEL 4610 ACCELEROMETER

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

OPERATION MANUAL Model 8011 & mA

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

LMM-H04 Mass Air FLow Sensor

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Heavy Duty Pressure Transducers Line Guide

PT9150 (Extended Range)

OPERATION MANUAL MODEL 805M1 ACCELEROMETER

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

OPERATION MANUAL MODEL 3038 ACCELEROMETER

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

OPERATION MANUAL MODEL 3255A ACCELEROMETER

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

OPERATION MANUAL MODEL 8102 ACCELEROMETER

TESS WIRELESS SENSOR TAG DEMO V1.1

MODEL ACCELEROMETER

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Transcription:

SPECIFICATIONS Mountable with O-ring seal Stainless Steel wetted surfaces Amplified ASIC calibrated Absolute, sealed gage Cable option Analog output SENT Output Optional (contact factory for details) FEATURES Mountable O-ring with seal ±0.5% Accuracy ±2.0 Total Error Band Cable option Freeze Protection Available APPLICATIONS Urea level Urea pressure Air brakes Corrosive fluid measurement for E&V applications Automotive The U86B is an automotive designed 16mm media isolated, piezoresistive silicon pressure sensor packaged in a 316L stainless steel housing and is designed for O-ring mounting. The sensing package utilizes silicone oil to transfer pressure from the 316L stainless steel diaphragm to the sensing element. The U86B is designed for high performance, low pressure applications. A custom ASIC is used for temperature compensation, offset correction, and provides an amplified output of 0.5 to 4.5V. CE approved and manufactured to TS16949 standard, this model may also come with a cable if desired. For a similar sensor without plastic housing, refer to the 86A or for a plastic threaded fitting, refer to the LM pressure transducer. SENSOR SOLUTIONS ///U86B 07/2018 Page 1

STANDARD RANGES Range psia, psig, psis Range bara, barg, bars 0 to 050 0 to 005 0 to 100 0 to 010 0 to 150 0 to 012 0 to 200 0 to 013 Other pressure ranges available, please contact factory PERFORMANCE SPECIFICATIONS Unless otherwise specified: Supply Voltage: 5V, Ambient Temperature: 25 C after 10 sec warm-up PARAMETERS MIN TYP MAX UNITS NOTES Supply Voltage 4.75 5.00 5.25 V Supply Current 12.5 ma DC Ratiometric Output 0.5 4.5 V 1, 5 Accuracy (combined linearity, hysteresis & repeatability) -0.5 0.5 %Span 2 Total Error Band -2.0 2.0 %Span 3 Compensated Temperature -7 +105 C Operating Temperature -40 +105 C Storage Temperature -40 +125 C Insulation Resistance (500V DC) 10 MΩ 4 Reverse Voltage 18 V Overvoltage Protection 18 V Short Circuit Protection Continuous Output Noise @ 1kHZ 13 mv Response Time (10% to 90%) 1.0 ms Long Term Stability -0.15 0.15 %Span/Year Output Load 47 kω Diagnostics Ability Included Notes 1. Ratiometric to supply voltage, pressure transfer function at 5V Voltage Supply, see Chart A 2. Best Fit Straight Line 3. TEB includes all accuracy errors, thermal errors, span and zero tolerance over the compensated range 4. Between sensor body to any pins of connector 5. This product can be configured for custom OEM requirements, contact factory for different transfer functions and output clipping. See Chart B SENSOR SOLUTIONS ///U86B 07/2018 Page 2

ENVIRONMENTAL SPECIFICATIONS PARAMETERS MIN TYP MAX UNITS NOTES Pressure Overload 2X Rated 6 Pressure Burst 3X Rated 7 Pressure Cycle 1M Cycles Material Port: 316/316L ST STL Sealing: FKM Fluoroelastomer 70 (O-Ring) Housing: PA66 + 30%GF Freezing Protecting Optional 9 Notes 6. The maximum pressure that can be applied without changing the transducer s performance or accuracy. 7. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer. 8. Transducers can be installed by M4X0.7 Torx washer head screws (qty 2) with 2.2Nm torque (values provided are for reference). Actual torque depends upon on mating support material, surface flatness and different screws. Transducer housing may crack if over-torqued when installing 9. Medium dead volume that exceeds 350mm 3 max in manifold (excluding sensor) may damage the sensor during frozen condition Agency Approvals EMC Performance Criteria: Output Change < ±1.5% of FS @RT ESD ISO 10605 Immunity Radiated Field ISO 11452-2 BCI ISO 11452-4 8kV Contact / 15kV Air Level V, 140V/m, 200MHz-3.2GHz d = 150mm, d = 450mm, d = 750mm Frequency Range: 1MHz-400MHz Modulation CW, AM Severity Level V (200mA) SENT Only Magnetic Field Test 15Hz to 150kHz, Level 4 ISO 11452-8 Emission Conducted. Voltage Mode/Current Probe Frequency Range: 150kHz 108MHz, Class 5 CISPR 25 Emission Radiated Frequency Range: 150kHz - 2.5GHz, Class 5 CISPR 25 Output Interface SENT (SAE J2716, 2010) SENSOR SOLUTIONS ///U86B 07/2018 Page 3

CHARTS Chart A: Pressure Transfer Function, Supply = 5V Output Voltage = 80% Supply V (Pressure Applied Pmin) + 10% Supply V Pmax Pmin Chart B: OEM Custom Calibration. High/Low Rail values can be adjusted by Circuit SENT Functional Block Diagram (Pin 1) (Pin 3) (Pin 2) SENSOR SOLUTIONS ///U86B 07/2018 Page 4

DIMENSIONS Dimensions are in inches [mm] Non-Vent Cap/Non-Freeze option shown See Note 8 See Note 9 SENSOR SOLUTIONS ///U86B 07/2018 Page 5

CABLE DIMENSIONS See Cable Ordering Information matrix for cable length options MOLEX HOUSING # 50-57-9403 MOLEX TERMINALS # 16-02-0082 (.100 [2.54] PITCH) HIGH TEMPERATURE CABLE, 3 CONDUCTORS, 24 AWG MOLEX CONNECTOR # 43645-0300 MOLEX TERMINALS # 43030-0003 CONDUCTOR: 24 AWG RATED VOLTAGE: 300V TEMPERATURE RANGE: -40 O C 200 O C Customer & Sensor Side Pos No Color Function 1 Red Supply 2 Black GND 3 Blue Output SENSOR SOLUTIONS ///U86B 07/2018 Page 6

ORDERING INFORMATION U86B 100P A 2 F 1 A Pressure Range 050P 005B 100P 010B 150P 012B 200P 013B Pressure Type G Gage A Absolute S Sealed Gage Output Ratiometric 1 0.5V @ 0.0barG/A/S 2 0.5V @-0.5barG/S 3 0.5V @ -1.0 barg/s Output Type A Analog Connector 1 Molex Freeze Protection N None F Freeze SENT Output available, contact factory for details CABLE ORDERING INFORMATION U86B CBL 010 1 Cable Length 005 5 [127] 010 10 [254] 020 20 [508] Connector 0 No Connector 1 Molex Connector #50579403 Cable Lengths are in inches[mm] NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity Company Tel: +1 800-522-6752 Email: customercare.frmt@te.com EUROPE Measurement Specialties (Europe), Ltd., a TE Connectivity Company Tel: +31 73 624 6999 Email: customercare.lcsb@te.com ASIA Measurement Specialties (China), Ltd., a TE Connectivity Company Tel: +86 0400-820-6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS ///U86B 07/2018 Page 7