HTLS. Heat Tracing Line Sensing Control Panel

Similar documents
Installation, Operation and. Maintenance Instructions

Installation, Operation Maintenance Instructions and

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

ITAS / ITAS-EXT / ITLS / ITLS-EXT

(HSTAT Series) Instruction Manual

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Installation and Operations Manual

- User Brochure tekmarnet 4 Setpoint Control 161

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

CFP2 Exde IMMERSION HEATER

HotPoly Tote Tank / IBC Heaters (TTH Series)

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Installation & Operation Manual

Installation & Operation Manual

Heating Cable. Description

CONDENSING WATER BOILERS. (Models VLT , Q VX ,

MaxLite LED MICRO-T PANEL

- User Brochure Programmable Thermostat 510

Installation & Operation Manual

Heating Cable. Description

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

First Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts)

Clean Steam Generators

OPERATION & INSTALLATION MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Controllers. Instruction Manual WARNING

Instruction Manual WARNING

INSTRUCTION MANUAL P Heating and 1 Cooling

FloorHeat Installation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MODEL 891 FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: SHIPPING DIMENSIONS: - 19"W 19"D 28"H SHIPPING WEIGHT: - 46 LBS.

Duct Mount. Installation Instructions

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

Humidity Monitor model 01080

Digital Refrigerator/Freezer Thermometer model 00986

Remote Relay Module (RRM)

TrueClean ToteCleaner

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

TrueClean ToteCleaner

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Quick Set-up Guide. 1. Location 2. Remove Mounting Base. 4. Switch Settings. 3. Install Mounting Base. 5. Wiring. Snow Melting Control PM-653

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

DigiTrace C910 Series Heat Trace Controller Installation, Operation, and Maintenance Manual

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

AG Series Electric Heaters

SEALING FIBER SEALING COMPOUND

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

ion Genesis Pump Controller

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

View the expanded manual: GEN5

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Air Pump Up to 800 gallons

Nov 08 PRODUCT SPECIFICATION SHEET

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

MaxLite LED Round Pendant Highbay Series

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Model R060 Installation - Operation Manual

Design Criteria. Installation

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

OPERATING INSTRUCTIONS

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Installation and Maintenance "L" and "LS" Series

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

LABORATORY ILLUMINATED FLOTATION BATH

Compact Equipment Warranty Policy

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Preamplifier Power Supply PPS-02 user's guide

MaxLite LED Vapor Tight Linear Fixture

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

INSTALLATION, OPERATION AND MAINTENANCE

Blade Series Heat Exchanger Operation and Installation

GTS. User Manual. Gas-to-Steam Humidifier. Affix product label here.

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Installation, Operation & Service Manual

EQUIPMENT Operation Manual

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

SC Installation, Operation & Application Guide

ALL-WEATHER LANDSCAPE BURIAL SUBWOOFERS Burial Subwoofers: 10 & 12 (250mm & 300mm)

Installation and Maintenance Instructions

C910 Series. Single-point heat-tracing control system

Transcription:

PDS Heat Tracing Line Sensing Control Panel Series 8000/12000/24000 Features: Color Touchscreen Operator Panel Eight/Twelve/Twenty Four Points of Independent Control NEMA 4/12 Enclosure High/Low Temperature Alarms Continuity Alarming Ground Fault Alarming/Trip Open Sensor Alarm Common Alarm Output Load Management Internal Power Distribution (Includes Circuit Breakers) 120, 240, and 277 Vac Global Programming Auto-Cycle Feature Current Display Failed Sensor Output Setting Loop Enable/Disable Hand/Off/Auto Selection Network Communications Applications: Process Temperature Maintenance Freeze Protection Roof/Gutter De-Icing Tank and Vessel Heat Tracing Snow Melting Floor Heating Steam Condensate Return Systems Fire Protection Systems C US Description The IntelliTRACE Series is a microprocessor based control/ monitoring and power management/distribution system for heat trace applications. The IntelliTRACE 8, 12, 24 loop heat trace system provides alarms for high / low temperature, continuity, ground fault leakage, and sensor faults. The advanced features include a color touchscreen operator interface panel that provides simple programming with no keyboards or cryptic labels. The panel displays loop status, alarm conditions and graphics on process temperatures, Technical Specifications setpoints, and currents. Through the Global Programming feature, operator setup time is greatly reduced. With the built-in power distribution, the IntelliTRACE multi-loop provides reduced material, installation, and maintenance costs. The load management eliminates the need for expensive ground fault breakers, limits inrush current and systematically interrogates all circuits for continuity, and ground fault leakage, sensor faults, and temperature alarms. Supply Voltage: 120, 240, and 277Vac, Three-Phase Operating Environment: 32-120ºF (0-40ºC) Communications: RS-485 MODBUS Input: RTD 100 Ω Platinum Three-Wire Output: Two-Pole Contactors Maximum Current: 24 Amps/Ckt Temperature Alarms: High/Low 2ºF Deadband Non-Latching Ground Fault Alarm: Adjustable 25-500 ma Factory Set @ 30 ma Continuity Alarm: < 2 amps Non-Latching Load Management: 15 sec. Non-Overlap to Reduce Inrush Auto-Cycle: Programmable to 720 Hrs (30 days) Failed Sensor Output Setting: 0-100% Control Mode: On/Off with adjustable deadband Phone: 1-888-996-9258 Fax: 615-793-3563 www.chromalox.com 2000 Wiegand Industrial Division Emerson Electric Co.

Advantages Highest Value/ Lowest Installed Cost Easy Retrofit into Existing Systems. Eliminates Ammeter Panels. Eliminates Signal Light Kits. Eliminates Monitor Wire Alarm Panels. Monitors Continuity without the use of Monitor Wire. Reduced Material and Installation Costs. Temperature/Monitor and Power Management / Distribution in One Package. Built-in GFI eliminates the need for separate Ground Fault Breakers. Lowest Learning Curve Simple Color Touchscreen Operator Panel (no Keyboards/no cryptic labels). Reduced Maintenance/Troubleshooting Time/Cost Temperature/Monitor and Power Management in one Package. Periodic Auto-Test Function Checks Continuity, Alarms & GFI Status on each loop. Continuous Monitoring of Heat Trace Circuits. 2 1382 Heil Quaker Blvd. LaVergne, TN 37086 PH: 1-888-996-9258 www.chromalox.com

Ordering Information MODEL 8000 Series Line Sensing Heat Trace Panel Order Table cul Listed Eight Loop Line Sensing Temperature/Monitor Heat Trace Panel. Nema 4 Steel Enclosure 36 H x 30 W x 8 D. Includes: Complete Prewired Controller, Two-Pole Contactors, Current Transformer to Measure Operating Currents, High/Low Temperature Alarms, On/Off Control, RTD Sensor Input, Color Touchscreen Programming, GFI Indication or Shutdown, Common Alarm Output, Hand/Off/Auto Selection, Loop Enable/Disable and Auto-Cycle Feature. Eight Independent Loops of Heat Trace Control 8. Voltage 0 120 Vac (Includes Single-Pole Circuit Breakers) 208Y/120 Vac Three-Phase Four-Wire 1 240 Vac (Includes Double-Pole Circuit Breakers) 240 Vac Three-Phase Three-Wire Delta 2 277 Vac (Includes Single-Pole Circuit Breakers) 480Y/277 Vac Three-Phase Four-Wire Circuit Breaker Rating Selection 1 15 amp Thermal Magnetic Circuit Breakers 2 20 amp Thermal Magnetic Circuit breakers 3 30 amp Thermal Magnetic Circuit Breakers Cabinet Heater 1 Thermostat Controlled Enclosure Heater Pressurization Control System 1 Type Z for Class I Division II Hazardous Location 8 2 3 1 1 Typical Model Number 3 1382 Heil Quaker Blvd. LaVergne, TN 37086 PH: 1-888-996-9258 www.chromalox.com

Ordering Information MODEL 12000 Series Line Sensing Heat Trace Panel Order Table cul Listed Twelve Loop Line Sensing Temperature/Monitor Heat Trace Panel. Nema 4 Steel Enclosure 48 H x 36 W x 10 D. Includes: Complete Prewired Controller, Two-Pole Contactors, Current Transformer to Measure Operating Currents, High/Low Temperature Alarms, On/off Control, RTD Sensor Input, Color Touchscreen Programming, GFI Indication or Shutdown, Common Alarm Output, Hand/Off/Auto Selection, Loop Enable/Disable and Auto-Cycle Feature Loop Disable and Auto-Cycle Feature. Twelve Independent Loops of Heat Trace Control 12. Voltage 0 120 Vac (Includes Single-Pole Circuit Breakers) 208Y/120 Vac Three-Phase Four-Wire 1 240 Vac (Includes Double-Pole Circuit Breakers) 240 Vac Three-Phase Three-Wire Delta 2 277 Vac (Includes Single-Pole Circuit Breakers) 480Y/277 Vac Three-Phase Four-Wire Circuit Breaker Rating Selection 1 15 amp Thermal Magnetic Circuit Breakers 2 20 amp Thermal Magnetic Circuit breakers 3 30 amp Thermal Magnetic Circuit Breakers Cabinet Heater 1 Thermostat Controlled Enclosure Heater Pressurization Control System 1 Type Z for Class I Division II Hazardous Location 12 2 3 1 1 Typical Model Number 1382 Heil Quaker Blvd. LaVergne, TN 37086 PH: 1-888-996-9258 www.chromalox.com 4

Ordering Information MODEL 24000 Series Line Sensing Heat Trace Panel Order Table cul Listed Twenty-Four Loop Line Sensing Temperature/Monitor Heat Trace Panel. Floor-Mount Nema 4 Steel Enclosure 60 H x 60 W x 12 D. Includes Complete Prewired Controller, Two-Pole Contactors, Current Transformer to Measure Operating Currents, High/Low Temperature Alarms, On/off Control, RTD Sensor Input, Color Touchscreen Programming, GFI Indication or Shutdown, Common Alarm Output, Hand/Off/Auto Selection, Loop Enable/Disable and Auto-Cycle Feature. 24. Twenty-Four Independent Loops of Heat Trace Control Voltage 0 120 Vac (Includes Single-Pole Circuit Breakers) 208Y/120 Vac Three-Phase Four-Wire 1 240 Vac (Includes Double-Pole Circuit Breakers) 240 Vac Three-Phase Three-Wire Delta 2 277 Vac (Includes Single-Pole Circuit Breakers) 480Y/277 Vac Three-Phase Four-Wire Circuit Breaker Rating Selection 1 15 amp Thermal Magnetic Circuit Breakers 2 20 amp Thermal Magnetic Circuit breakers 3 30 amp Thermal Magnetic Circuit Breakers Cabinet Heater 1 Thermostat Controlled Enclosure Heater Pressurization Control System 1 Type Z for Class I Division II Hazardous Location 24 2 3 1 1 Typical Model Number 1382 Heil Quaker Blvd. LaVergne, TN 37086 PH: 1-888-996-9258 www.chromalox.com 5

WARRANTY AND LIMITATION OF REMEDY AND LIABILITY Chromalox warrants only that the Products and parts by Chromalox, when shipped and the work performed by Chromalox when performed, will meet all applicable specification and other specific product and work requirements (including those of performance), if any, and will be free from defects in material and workmanship under normal condition of use. All claims for defective or nonconforming (both hereinafter called defective) Products, parts or work under this warranty must be made in writing immediately upon discovery, and in any event, within one (1) year from delivery, provided, however all claims for defective Products and parts must be made in writing no later than eighteen (18) months after shipment by Chromalox. Defective and nonconforming items must be held for Chromalox's inspections and returned tot he original f.o.b. point upon request. THE FOREGOING IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIED WHATSOEVER EXPRESS, IMPLIED AND STATUTORY, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Notwithstanding the provisions of this WARRANTY AND LIMITATION Clause, it is specifically understood that Products and parts not manufactured and work not performed by Chromalox are warranted only to the extent and in the manner that the same are warranted to Chromalox by Chromalox's vendors, and then only to the extent that Chromalox is reasonably able to enforce such warranty, it being understood Chromalox shall have no obligation to initiate litigation unless Buyer undertakes to pay all expenses therefor, including but limited to attorney s fees, and indemnifies Chromalox against any liability to Chromalox's vendors arising out of such litigation. THE FOREGOING IS CHROMALOX'S ONLY OBLIGATION AND BUYERS EXCLUSIVE REMEDY FOR BREACH OF WARRANTY, AND IS BUYERS EXCLUSIVE REMEDY AGAINST CHROMALOX FOR ALL CLAIMS ARISING HERE UNDER OR RELATING HERETO WHETHER SUCH CLAIMS ARE BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORIES, BUYERS FAILURE TO SUBMIT A CLAIM AS PROVIDED ABOVE SHALL SPECIFICALLY WAIVE ALL CLAIMS FOR DAMAGES OR OTHER RELIEF, INCLUDING BUT NOT LIMITED TO CLAIMS BASED ON LATENT DEFECTS. IN NO EVENT SHALL BUYER BE ENTITLED TO INCIDENTAL, OR CONSEQUENTIAL DAMAGES AND BUYER SHALL HOLD CHROMALOX HARMLESS THEREFROM ANY ACTION BY BUYER ARISING HERE UNDER OR RELATING HERETO, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORIES, MUST BE COMMENCED WITHIN ONE (1) YEAR AFTER THE DATE OF SHIPMENT OR IT SHALL BE BARRED. W2008M PDS October 2000 1382 Heil Quaker Blvd. LaVergne, TN 37086 PH: 1-888-996-9258 www.chromalox.com 6