Daikin leads the way:

Similar documents
Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Air Conditioners Heating & Cooling

usiness concern our Sky air product range commercial catalogue Preliminary version

Air conditioners Heating & Cooling

usiness concern our Sky air product range commercial catalogue

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Pure comfort & design

Pure comfort & design

Air conditioners Heating & Cooling

usiness concern our SKY AIR PRODUCT RANGE COMMERCIAL CATALOGUE

Pure comfort & design

Air Conditioners Technical Data

Pure comfort & design

Air Conditioning Systems

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air Conditioners Heating & Cooling

Concealed ceiling units

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioners Technical Data

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data EEDEN AZQS-BV1

Heating & Cooling. Air conditioners. M u l t i m o d e l a p p l i c a t i o n. » SEER up to A ++ » Energy efficient heating & cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioners. Technical Data FTY-H

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Air conditioners, heating & cooling for shops,restaurants and offices

Sky Air. Product catalogue for installers Your business is our concern

Air Conditioners Technical Data

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Technical Data

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Fan Coil Units. Technical Data FWC-BT/BF

Air conditioners Cooling only

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air conditioners, heating & cooling for the retailmarket and offices

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

AIR CONDITIONERS, HEATING & COOLING for your home

emura Form. function. redefined.

Daikin air conditioners for your home, shops, restaurants and offices

where innovation meets creativity

for your home FLXS-B Flexi type unit air to air heat pumps

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Europe s new energy label: raising the bar on energy efficiency

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Air Purifiers. Technical Data MC70L

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

The natural ombination

Air Conditioners Technical Data

for small rooms in multi application

for the retail market, hotels, restaurants and offices

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Daikin Altherma hybrid heat pump. The natural combination

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

DAIKIN Air Handling Unit Modular

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

GAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

VZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

SUPERB TECHNOLOGY FOR SUPERB INTERIORS

Our mission: beating the winter cold

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Europe s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact

VRV The total solution. Integrated Climate Control

Air Conditioners. Technical Data RZQG-L

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Air conditioners Heating & Cooling

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

w w w. d a i k i n. e u ATXS-E

Infrastructure cooling solution

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Transcription:

Daikin leads the way: Offering a full range of light commercial products optimised for seasonal efficiency All Seasons Climate comfort Heating Air Conditioning Applied Systems Refrigeration

Daikin leads the way to seasonal efficiency introducing a full light commercial range optimised for seasonal efficiency! With its 20/20/20 energy policy, Europe is seeking 20% less CO 2 produced, 20% more renewable energy used and 20% less primary energy consumed by 2020. To help achieve these targets it has issued the Energy Related Products Directive which specifies minimum eco-design requirements, such as improved energy efficiency, that must be integrated into energy-using products. For air conditioners below 12kW, the minimum requirements will be based on a new seasonal efficiency ratio and Daikin Europe N.V. has already integrated these improvements into the new Sky Air range of light commercial applications, thus underling our commitment to reducing environmental impact. European action plan C0 2-20% +20% -20% CO 2 emissions vs. 1990 Share of renewable energy Primary energy use vs. BAU* *Business As Usual By the year 2020 Measuring real-life performance The EU requires objective performance metrics to establish the minimum requirements that must be met, and to provide customers with information on air conditioner performance on which to base their choice. The current methodology nominal efficiency (EER) results in a significant gap between announced and actual performance and so a more accurate method seasonal efficiency (SEER) has been developed. The major changes include the integration of several rating temperatures for cooling and heating, the inclusion of energy use at part-load as well as full-load and the power used in auxiliary and standby modes. Since most systems operate under a partial load the majority of the time, the new methodology gives a better indication of expected real-life performance. Nominal versus Seasonal efficiency 40 50 60 70 30 80 20 90 Temperature Nominal Seasonal 10 CAPACITY 100 Capacity Nominal Seasonal Auxiliary modes Nominal Seasonal 1 Temperature condition: 35 C for cooling 7 C for heating Does not often occur in reality Several rating temperatures for cooling and heating, reflecting actual performance over an entire season Does not reflect partial capacity Benefits of inverter technology not visible Integrates operation at partial instead of full capacity Benefits of inverter technology are shown Does not take auxiliary power modes into account Includes consumption auxiliary modes: Thermostat off Standby mode OFF mode Crankcase heater Nominal efficiency gives an indication of how efficiently an air conditioner operates in nominal conditions. Seasonal efficiency gives an indication of how efficiently an air conditioner operates over an entire cooling or heating season.

Daikin leads the way: Seasonal series Daikin is the first in the industry to have a full light commercial range optimised for seasonal efficiency and already meeting the very challenging requirements of 2014 ErP while 2013 is still not yet implemented. Seasonal series Seasonal Smart and Seasonal Classic offer more than 20% better performance than current existing inverter series, which is fully in line with 20/20/20 EU policy. This can even be enhanced with a smart use of unique Daikin options. The technology used allows achieving very high of seasonal efficiency while still maintaining or improving the comfort and flexibility features that make Daikin so unique. Daikin has a solution for all your needs: Seasonal Smart offers TOP seasonal efficiency. It answers needs for projects requiring high flexibility like longer piping lengths, wider operating range or EDP applications. Efficiency and comfort can be further enhanced with selectable evaporating and condensing temperature. Seasonal Classic offers a suitable solution for budget applications where less flexibility is required. Daikin offers now a complete light commercial range, optimised for seasonal efficiency! new new new new FCQG / FCQHG FFQ FHQG FBQ FDQ FAQ FVQ FUQ RZQG-L RZQSG-L So what s new? Thanks to this new design, Sky Air Seasonal Smart and Seasonal Classic outdoor units boast average seasonal efficiency improvements of more than 20% over the current Sky Air Inverter, and of more than 50% compared to non-inverter systems. The compressor and heat exchanger have been completely redesigned to offer optimal efficiency at partial conditions. The inverter control has been optimised over the full temperature distribution curve, providing so optimum partial load performance and giving it high ratings in real-life operating conditions. The auxiliary modes have been redesigned to reduce residual energy consumption. In addition to its high seasonal performance, the new Sky Air seasonal series includes benefits such as a wide operating range, ability to re-use existing piping as only the indoor and outdoor unit needs to be replaced, night quiet mode reducing the sound of the outdoor unit. Further enhancement of efficiency and comfort can be achieved on Seasonal Smart thanks to selectable evaporating and condensing temperature. Newly designed indoors offer optimised seasonal efficiency while improvement comfort and flexibility: round flow cassette (FCQG/FCQHG) new ceiling suspended cassette (FHQG) floor standing model (FVQ) new wall mounted unit (FAQ) new concealed ceiling unit (FBQ/FDQ) new

So what s new: Indoor units Next generation round flow cassette, setting the standard for efficiency and comfort The round flow cassette is designed for use in all forms and sizes of commercial offices, retail spaces, restaurants, hotels and other applications. Today, Daikin has improved its technology even further to enhance your comfort and provide you better energy efficient models. With a new infrared presence and floor sensor Daikin offers you the best solution for your application. With an auto cleaning panel, efficiency and air flow and therefore comfort are maintained optimal. infrared presence sensor infrared floor sensor Other features Without sensor Cooling Set point: 22 CDB Even more energy efficient The optional presence sensor adjusts the temperature or switches off the unit when there is nobody in the room. Up to 27% energy can be saved with this new function Estimated energy saving: up to 27% > Daikin was the first to launch an auto cleaning decoration panel. With this panel the costs can be further reduced as the filter cleans itself automatically once a day Maintenance on filter is facilitated: less time is required. Running cost can be reduced compared to standard solutions: up to 50% energy can be saved thanks to daily filter cleaning (Wolverhampton, UK) inside temperature ( CDB) inside temperature ( CDB) time time 26 24 22 20 26 24 22 20 09.00 With sensor (kwh) 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 July 09.00 Auto cleaning cassette Nobody in the room 09.30 10.00 10.30 11.00 11.30 12.00 12.30 13.00 13.30 14.00 14.30 15.00 15.30 09.30 10.00 10.30 11.00 11.30 12.00 12.30 13.00 13.30 14.00 14.30 15.00 15.30 Energy consumption Cumulative energy comparison over 12 months (Test site, Wolverhampton, UK) > August September October November December January February March April May June 16.00 16.30 17.00 16.00 16.30 17.00 50% difference in electricity consumption Standard round flow cassette July

and improved comfort Already, the unique 360 air flow discharge pattern ensures a uniform temperature distribution across the room without dead corners The comfort can be further enhanced thanks to the optional sensor: The presence sensor allows air flow control. It directs the away from any person detected in the room, when the air flow control is on. With the floor sensor having cold feet becomes history. This sensor detects the average floor temperature and ensures even temperature distribution between ceiling and floor. Flexible installation The new cassette offers higher flexibility thanks to: The possibility to easily close one or more flaps via the wired remote controller (BRC1E52 - optional), to suit the room configuration. Optional closure kits are available as well > change room configuration/ refurbishment Air conditioning with smart use User friendly remote controller BRC1E52A new A series of energy saving functions that can be individually selected new Temperature range limit Improved setback function Presence & floor sensor connection (available on new round flow cassette) Setting temperature auto reset Off timer kwh indication new 3 weekly timers new

Wall mounted unit FAQ-C Seasonal efficiency, optimised for all seasons Ideal solution for shops, restaurants or offices without false ceilings Extension of the range: a 125 class has been developed for installation in larger rooms Modern style flat front panel Front panel can easily be removed and cleaned No optional adapter needed for DIII-connection Automatic fan speed selection: 3 fan speeds can be selected D3 compatibility as standard FAQ71,100C Concealed ceiling unit FDQ-C Seasonal efficiency, optimised for all seasons Up to 200Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas New casing: reduced height to fit flush into false ceilings Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Easy installation: less duct calculations are needed; moreover, the air flow can be adjusted during installation via the wired remote control (optional) instead of via channel adjustments. Standard drain pump FDQ125C Tall floor standing unit FVQ-C Seasonal efficiency, optimised for all seasons During start up, the room can be cooled down or heated very quickly; once the temperature in the room has reached its set point, the low power operation starts to save energy Better air flow distribution is achieved via individual blow: up and down, swing mechanism or air volume control (class 71 & 100). D3 compatibility as standard FVQ-C

So what s new: Outdoor units Seasonal efficiency outdoor units RZQG-L Seasonal efficiency, optimised for all seasons Seasonal smart series already comply with the EU s 2014 Eco-Design requirements, while 2013 still not yet implemented Suits computer room applications (EDP) Re-use of existing R-22 or R-407C technology Down to -20 C in heating mode Standard night quiet mode Maximum piping length up to 75m Minimum piping length: no limitation Compatibility with D-BACS Reduction of power consumption via i-demand option Further enhancement of efficiency and or comfort thanks to selectable evaporating and condensing temperature Seasonal efficiency outdoor units RZQSG-L Preliminary Seasonal efficiency, optimised for all seasons Seasonal Classic already complies with the EU s 2014 Eco-Design requirements, while 2013 still not yet implemented Re-use of existing R-22 or R-407C technology Down to -15 C in heating mode Maximum piping length up to 50m Minimum piping length: no limitation Compatibility with D-BACS Reduction of power consumption via i-demand option

Specifications INDOOR UNIT FCQHG71F FCQHG100F FCQHG125F FCQHG140F OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 RZQG140L7V1 RZQG140LY1 EER 4.09 4.42 4.00 3.35 COP 4.80 4.99 4.40 4.12 Energy label Cooling/Heating A/A A/A A/A A/A SEER 6.11 6.21 6.00 - SCOP 4.18 4.30 3.89 - Pdesign (@ -10 C) 7.6 11.3 14.1 - Casing Material Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Dimensions Unit HeightxWidthxDepth mm 288x840x840 288x840x840 288x840x840 288x840x840 Weight Unit kg 25 25 25 25 Model BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 Decoration panel Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 50x950x950 50x950x950 50x950x950 Weight kg 5.5 5.5 5.5 5.5 Decoration panel Model BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W Decoration panel Model BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 Sound pressure Cooling High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 INDOOR UNIT FCQHG71F FCQHG100F FCQHG125F FCQHG140F OUTDOOR UNIT RZQSG71LV1 RZQSG71LY1 RZQSG100LV1 RZQSG100LY1 RZQSG125LY1 RZQSG125LV1 RZQSG140LV1 RZQSG140LY1 EER 3.50 3.70 3.23 3.21 COP 4.10 4.30 3.75 3.61 Energy label Cooling/Heating A/A A/A A/A A/A SEER 5.70 5.70 5.21 - SCOP 3.95 3.91 3.81 - Pdesign (@ -10 C) 7.6 8.0 8.0 - Casing Material Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Dimensions Unit HeightxWidthxDepth mm 288x840x840 288x840x840 288x840x840 288x840x840 Weight Unit kg 25 25 25 25 Model BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 Decoration panel Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 50x950x950 50x950x950 50x950x950 Weight kg 5.5 5.5 5.5 5.5 Decoration panel Model BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W Decoration panel Model BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 Sound pressure Cooling High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 INDOOR UNIT FCQG71F FCQG100F FCQG125F FCQG140F OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 RZQG140L7V1 RZQG140LY1 EER 3.39 3.87 3.73 3.21 COP 3.97 4.15 3.63 3.61 Energy label Cooling/Heating A/A A/A A/A A/A SEER 5.81 5.99 5.69 - SCOP 4.13 3.93 3.84 - Pdesign (@ -10 C) 6.3 11.3 12.7 - Casing Material Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 246x840x840 246x840x840 Weight Unit kg - - - - Model BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 Decoration panel Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 50x950x950 50x950x950 50x950x950 Weight kg 5.5 5.5 5.5 5.5 Decoration panel Model BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W Decoration panel Model BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 Cooling High/Low m³/min -/- -/- 27.5/19.0 27.5/19.0 Heating High/Low m³/min -/- -/- 27.5/19.0 27.5/19.0 Sound pressure Cooling High/Nom./Low dba 33/31/28 37/35/32 41/38/35 41/38/35 Heating High/Nom./Low dba 33/31/28 37/35/32 41/38/35 41/38/35 Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 INDOOR UNIT FCQG71F FCQG100F FCQG125F FCQG140F OUTDOOR UNIT RZQSG71LV1 RZQSG71LY1 RZQSG100LV1 RZQSG100LY1 RZQSG125LY1 RZQSG125LV1 RZQSG140LV1 RZQSG140LY1 EER 3.21 3.30 3.21 3.01 COP 3.61 3.54 3.41 3.41 Energy label Cooling/Heating A/A A/B A/B B/B SEER 5.11 5.11 5.11 - SCOP 3.81 3.80 3.81 - Pdesign (@ -10 C) 6.3 7.6 7.6 - Casing Material Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 246x840x840 246x840x840 Weight Unit kg - - - - Model BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 BYCQ140DW1 Decoration panel Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) Dimensions HeightxWidthxDepth mm 50x950x950 50x950x950 50x950x950 50x950x950 Weight kg 5.5 5.5 5.5 5.5 Decoration panel Model BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W BYCQ140DW1W Decoration panel Model BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 BYCQ140DGW1 Cooling High/Low m³/min -/- -/- 27.5/19.0 27.5/19.0 Heating High/Low m³/min -/- -/- 27.5/19.0 27.5/19.0 Sound pressure Cooling High/Nom./Low dba 33/31/28 37/35/32 41/38/35 41/38/35 Heating High/Nom./Low dba 33/31/28 37/35/32 41/38/35 41/38/35 Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220

INDOOR UNIT FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8 OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 RZQG140L7V1 RZQG140LY1 EER 3.50 3.89 3.81 3.33 COP 3.65 4.21 3.83 3.61 Energy label Cooling/Heating A/A A/A A/A A/A SEER 5.61 5.61 5.61 - SCOP 4.01 4.25 4.05 - Pdesign (@ -10 C) 6.0 11.3 12.7 - Dimensions Unit HeightxWidthxDepth mm 300x1,000x700 300x1,400x700 300x1,400x700 300x1,400x700 Weight Unit kg - - - - Cooling High/Low m³/min 18/15 32/23 39/28 39/28 Fan - External static pressure High/Nom. Pa 100/30 120/40 120/50 120/50 Sound power Cooling Nom. dba 57 61 66 66 Sound pressure Cooling High/Low dba 37/29 38/32 40/33 40/33 Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 INDOOR UNIT FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8 OUTDOOR UNIT RZQSG71LV1 RZQSG71LY1 RZQSG100LV1 RZQSG100LY1 RZQSG125LV1 RZQSG125LY1 RZQSG140LV1 RZQSG140LY1 EER 3.28 3.31 3.21 3.02 COP 3.61 3.65 3.51 3.41 Energy label Cooling/Heating A/A A/A A/B B/B SEER 5.11 5.11 4.35 - SCOP 3.81 3.81 3.81 - Pdesign (@ -10 C) 6.0 7.6 7.6 - Dimensions Unit HeightxWidthxDepth mm 300x1,000x700 300x1,400x700 300x1,400x700 300x1,400x700 Weight Unit kg - - - - Cooling High/Low m³/min 18/15 32/23 39/28 39/28 Fan - External static pressure High/Nom. Pa 100/30 120/40 120/50 120/50 Sound power Cooling Nom. dba 57 61 66 66 Sound pressure Cooling High/Low dba 37/29 38/32 40/33 40/33 Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 INDOOR UNIT FHQG71C FHQG100C FHQG125C FHQG140C OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 RZQG140L7V1 RZQG140LY1 EER 3.82 3.81 3.35 3.31 COP 4.13 4.15 3.89 3.63 Energy label Cooling/Heating A/A A/A A/A A/A SEER 5.65 5.69 5.11 - SCOP 3.95 4.20 4.01 - Pdesign (@ -10 C) 7.6 11.3 14.1 - Casing Colour Fresh white (6.5Y 9.5/0.5) Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690 Weight Unit kg 32 38 Cooling High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 Heating High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 Sound power Cooling Nom. dba 55 60 62 64 Sound pressure Cooling High/Nom./Low dba 38/36/34 42/38/34 44/41/37 46/42/38 Heating High/Nom./Low dba 38/36/34 42/38/34 44/41/37 46/42/38 Piping connections Drain OD mm - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 INDOOR UNIT FHQG71C FHQG100C FHQG125C FHQG140C OUTDOOR UNIT RZQSG71LV1 RZQSG71LY1 RZQSG100LV1 RZQSG100LY1 RZQSG125LV1 RZQSG125LY1 RZQSG140LV1 RZQSG140LY1 EER 3.46 3.21 2.89 3.01 COP 4.00 3.61 3.62 3.41 Energy label Cooling/Heating A/A A/A C/A B/B SEER 5.11 5.11 4.61 - SCOP 3.81 3.80 3.81 - Pdesign (@ -10 C) 7.6 7.6 7.6 - Casing Colour Fresh white (6.5Y 9.5/0.5) Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690 Weight Unit kg 32 38 Cooling High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 Heating High/Nom./Low m³/min 20.5/17/14 28/24/20 31/27/23 34/29/24 Sound power Cooling Nom. dba 55 60 62 64 Sound pressure Cooling High/Nom./Low dba 38/36/34 42/38/34 44/41/37 46/42/38 Heating High/Nom./Low dba 38/36/34 42/38/34 44/41/37 46/42/38 Piping connections Drain OD mm - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240

Specifications INDOOR UNIT FAQ71C FAQ100C FAQ125C OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 EER 3.40 3.62 - COP 3.70 3.61 - Energy label Cooling/Heating A/A A/A - SEER 5.21 5.11 - SCOP 3.90 4.01 - Pdesign (@ -10 C) 6.3 10.2 - Casing Colour Fresh white (6.5Y 9.5/0.5) Fresh white (6.5Y 9.5/0.5) - Material Resin Resin - Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 340x1,200x240 Weight Unit kg 13 17 17 Cooling High/Nom./Low m³/min 18/16/14 26/23/19 -/-/- Heating High/Nom./Low m³/min 18/16/14 26/23/19 -/-/- Cooling High/Nom./Low dba 61/58/56 65/62/58 -/-/- Sound power Heating High/Nom./Low dba 61/58/56 65/62/58 -/-/- Sound pressure Cooling High/Nom./Low dba 45/42/40 49/45/41 -/-/- Heating High/Nom./Low dba 45/42/40 49/45/41 -/-/- Piping connections Drain OD mm - - - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 INDOOR UNIT FAQ71C FAQ100C FAQ125C OUTDOOR UNIT RZQSG71LV1 RZQSG71LY1 RZQSG100LV1 RZQSG100LY1 RZQSG125LV1 RZQSG125LY1 EER 3.21 3.01 - COP 3.61 3.41 - Energy label Cooling/Heating A/A B/B - SEER 5.11 4.61 - SCOP 3.81 3.81 - Pdesign (@ -10 C) 6.0 6.8 - Casing Colour Fresh white (6.5Y 9.5/0.5) Fresh white (6.5Y 9.5/0.5) - Material Resin Resin - Dimensions Unit HeightxWidthxDepth mm 290x1,050x238 340x1,200x240 340x1,200x240 Weight Unit kg 13 17 17 Cooling High/Nom./Low m³/min 18/16/14 26/23/19 -/-/- Heating High/Nom./Low m³/min 18/16/14 26/23/19 -/-/- Cooling High/Nom./Low dba 61/58/56 65/62/58 -/-/- Sound power Heating High/Nom./Low dba 61/58/56 65/62/58 -/-/- Sound pressure Cooling High/Nom./Low dba 45/42/40 49/45/41 -/-/- Heating High/Nom./Low dba 45/42/40 49/45/41 -/-/- Piping connections Drain OD mm - - - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 1~ / 50/60 / 220-240/220 INDOOR UNIT FVQ71C FVQ100C FVQ125C FVQ140C OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 RZQG140L7V1 RZQG140LY1 EER 3.37 3.81 3.21 3.21 COP 3.64 4.14 3.70 3.61 Energy label Cooling/Heating A/A A/A A/A A/A SEER 5.16 5.59 4.77 - SCOP 3.81 3.80 3.85 - Pdesign (@ -10 C) 6.3 11.3 11.3 - Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x350 1,850x600x350 Weight Unit kg 39 47 47 47 Sound power Cooling High/Nom./Low dba 55/53/50 62/59/56 63/60/58 65/63/60 Sound pressure Cooling High/Nom./Low dba 43/41/38 50/47/44 51/48/46 53/51/48 Power supply Phase / Frequency / Voltage Hz / V 1~/ 50/60 /220-240/220 INDOOR UNIT FVQ71C FVQ100C FVQ125C FVQ140C Outdoor unit RZQSG71LV1 RZQSG71LY1 RZQSG100LV1 RZQSG100LY1 RZQSG125LV1 RZQSG125LY1 RZQSG140LV1 RZQSG140LY1 EER 3.21 3.21 2.81 3.01 COP 3.61 3.61 3.41 3.41 Energy label Cooling/Heating A/A A/A C/B B/B SEER 5.11 5.11 4.31 - SCOP 3.81 3.80 3.81 - Pdesign (@ -10 C) 6.0 7.6 7.6 - Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x350 1,850x600x350 Weight Unit kg 39 47 47 47 Sound power Cooling High/Nom./Low dba 55/53/50 62/59/56 63/60/58 65/63/60 Sound pressure Cooling High/Nom./Low dba 43/41/38 50/47/44 51/48/46 53/51/48 Power supply Phase / Frequency / Voltage Hz / V 1~/50-60/220-240/220

INDOOR UNIT FUQ71B FUQ100B FUQ125B OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 EER 4.05 3.86 3.39 COP 4.08 3.95 3.42 Energy label Cooling/Heating A/A A/A A/B SEER 5.25 4.67 4.41 SCOP 3.89 4.02 4.09 Pdesign (@ -10 C) 5.1 9.0 11.3 Casing Colour White Material Resin Dimensions Unit HeightxWidthxDepth mm 165x895x895 230x895x895 Weight Unit kg 25.0 31.0 Cooling High/Low m³/min 19.0/14.0 29.0/21.0 32.0/23.0 Heating High/Low m³/min 19.0/14.0 29.0/21.0 32.0/23.0 Cooling High/Low dba 56/51.0 59.0/54.0 60/55 Sound power Heating High/Low dba 56/51 59.0/54.0 60/55 Sound pressure Cooling High/Low dba 40/35 43.0/38.0 44/39 Heating High/Low dba 40/35 43.0/38.0 44/39 Piping connections Drain OD mm - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 INDOOR UNIT FDQ125C OUTDOOR UNIT RZQG125L7V1 RZQG125LY1 EER 3.75 COP 3.83 Energy label Cooling/Heating A/A SEER 5.61 SCOP 4.05 Pdesign (@ -10 C) 12.7 Casing Colour Not painted (galvanised) Dimensions Unit HeightxWidthxDepth mm 300x1,400x700 Weight Unit kg 45 Model BYBS125DJW1 Decoration panel Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x1,500x500 Weight kg 6.5 Cooling High/Low m³/min 39/28 Heating High/Low m³/min 39/28 Fan - External static pressure High/Nom. Pa 200/50 Sound power Cooling Nom. dba 66 Sound pressure Cooling High/Low dba 40/33 Heating High/Low dba 40/33 Piping connections Drain OD mm - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220 INDOOR UNIT FDQ125C OUTDOOR UNIT RZQSG125LV1 RZQSG125LY1 EER 3.21 COP 3.51 Energy label Cooling/Heating A/B SEER 4.31 SCOP 3.81 Pdesign (@ -10 C) 7.6 Casing Colour Not painted (galvanised) Dimensions Unit HeightxWidthxDepth mm 300x1,400x700 Weight Unit kg 45 Model BYBS125DJW1 Decoration panel Colour White (10Y9/0.5) Dimensions HeightxWidthxDepth mm 55x1,500x500 Weight kg 6.5 Cooling High/Low m³/min 39/28 Heating High/Low m³/min 39/28 Fan - External static pressure High/Nom. Pa 200/50 Sound power Cooling Nom. dba 66 Sound pressure Cooling High/Low dba 40/33 Heating High/Low dba 40/33 Piping connections Drain OD mm - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50/60 / 220-240/220

Specifications OUTDOOR UNIT RZQG71L7V1 RZQG71LY1 RZQG100L7V1 RZQG100LY1 RZQG125L7V1 RZQG125LY1 RZQG140L7V1 RZQG140L7Y1 Dimensions Unit HeightxWidthxDepth mm 990x940x320 990x940x320 1,430x940x320 1,430x940x320 1,430x940x320 1,430x940x320 1,430x940x320 1,430x940x320 Weight Unit kg 77 77 99 99 99 99 99 99 Sound power Cooling Nom. dba 64 64 66 66 67 67 68 68 Sound pressure Cooling Nom. dba 48 48 50 50 51 51 51 51 Heating Nom. dba 50 50 52 52 53 53 53 53 Night quiet mode Level 1 dba 43 43 45 45 45 45 45 45 Compressor Type - - - - - - - - Operation range Cooling Ambient Min.~Max. CDB -15~50-15~50-15~50-15~50-15~50-15~50-5~46-5~46 Heating Ambient Min.~Max. CWB -20~15.5-20~15.5-20~15.5-20~15.5-20~15.5-20~15.5-10~15.5-10~15.5 Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Piping Additional refrigerant charge kg/m - - - - - - - - connections Level difference IU - OU Max. m - - - - - - - - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400 OUTDOOR UNIT RZQSG71LV1 RZQSG71LY1 RZQSG100LV1 RZQSG100LY1 RZQSG125LV1 RZQSG125LY1 RZQSG140LV1 RZQSG140LY1 Dimensions Unit HeightxWidthxDepth mm 770x900x320 770x900x320 990x940x320 990x940x320 990x940x320 990x940x320 1,430x940x320 1,430x940x320 Weight Unit kg 68 68 77 77 77 77 99 99 Sound power Cooling Nom. dba - - - - - - - - Sound pressure Cooling Nom. dba - - - - - - - - Heating Nom. dba - - - - - - - - Night quiet mode Level 1 dba - - - - - - - - Compressor Type - - - - - - - - Operation range Cooling Ambient Min.~Max. CDB -5~46-5~46-5~46-5~46-5~46-5~46-5~46-5~46 Heating Ambient Min.~Max. CWB -10~15.5-10~15.5-10~15.5-10~15.5-10~15.5-10~15.5-10~15.5-10~15.5 Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A Piping Additional refrigerant charge kg/m - - - - - - - - connections Level difference IU - OU Max. m - - - - - - - - Power supply Phase / Frequency / Voltage Hz / V 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400 1~ / 50 / 220-240 3~ / 50 / 400 Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. FSC ECPEN12-500P Daikin products are distributed by: Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.euroventcertification.com or using: www.certiflash.com Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende ECPEN12-500_P 1000 10/11 Copyright Daikin The present publication supersedes ECPEN11-500_P2 Printed in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environment is set in the EMAS and ISO 14001 systems. Responsible editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende