I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Similar documents
WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

10.85 VicFlex Sprinkler Fittings

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85

TECHNICAL DATA. Wet 26a. February 22, 2009

Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

FIGURE 1. Model RD107

esfr dry pendent sprinkler Vk502 (k14.0)

esfr dry pendent sprinkler Vk501 (k14.0)

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

40.31 V34, K14.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

Data Sheet 4.19 Issue C

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

standard response dry horizontal sidewall sprinklers

40.43 V38, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Low Flow Adjustable Concealed Pendent V3806 QUICK RESPONSE

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

TECHNICAL DATA NOTICE

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

standard response/ quick response extended coverage

DISCONTINUED PRODUCT. reference publication

STANDARD RESPONSE DRY PENDENT ELO SPRINKLERS TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS

40.10 V27, K5.6. Standard Spray; Upright, Pendent and Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

standard response large orifice dry

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Sprinkler Identification Numbers

Audi-Larm Audible Alarm

Standard response. elo sprinklers

standard response dry horizontal sidewall sprinklers

SuperKlean Washdown Products

DISCONTINUED PRODUCT

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Residential Flat Concealed Sprinkler, Pendent, Model: CN-RES, K-Factor: 4.9, SIN: SS8421

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler. Product Features. Product Description

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

Norminal Sprinkler Temperature Rating

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

40.11 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

SENJU SPRINKLER CO., LTD.

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

esfr pendent sprinkler vk510 (k25.2)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

SENJU SPRINKLER CO., LTD.

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

40.15 V34, K8.0 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Data Sheet 4.16 Issue D

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Sprinkler Identification Numbers

Transcription:

INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems Read and understand all instructions before attempting to install any Victaulic VicFlex products. Wear safety glasses, hardhat, and foot protection. These installation instructions are intended for an experienced, trained installer. The user shall understand the purpose of these products, c ommon industry standards for safety, and the potential consequences of improper product installation. It is the system designer s responsibility to verify suitability of stainless steel flexible hose for use with the intended fluid media within the piping system and external environment. The effect of chemical composition, ph level, operating temperature, chloride level, oxygen level, and flow rate on the stainless steel flexible hose shall be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause improper sprinkler operation and product failure, resulting in death or serious personal injury and property damage. Flexible Hose Listing and Approval Information Flexible Hose G1202 101-01 AH1 With AB With AB With AB With AB AH1-CC With AB With AB With AB AH2 With AB With AB With AB With AB AH2-CC With AB With AB With AB AH2-00 With AB AH2-68 With AB NOTES: Victaulic VicFlex flexible hoses are City of Los Angeles (RR5659) Approved, accepted for use by the City of New York Department of Buildings (MEA 60-05-E), and have the OSHPD Pre-Approval (OPA-2255-07). Flexible hoses are available in lengths from 1-72 inches/787-1829 mm with either 1/2-inch/DN15 or /-inch/dn20 NPT or BSPT threaded outlets. Maximum Working Pressure Rating of Flexible Hose: 200 psi/1 Bar/179 kpa (FM) 175 psi/12 Bar/1207 kpa (UL) 16 Bar/1600 kpa/22 psi (VdS, LPCB) 00 psi/21 Bar/2068 kpa (FM Series AH2-00) Maximum Ambient Temperature Rating of Flexible Hose: 225 F/107 C Connection to Sprinkler Piping: 1 inch/dn25 NPT/BSPT (UL, FM) 1 inch/dn25 IGS (UL, FM, VdS) DN20// inch BSPT (VdS) DN2/1 1/ inch BSPT (LPCB) of Flexible Hose: inch/76 mm (UL Series AH1, AH1-CC) 2 inch/50 mm (UL Series AH2, AH2-CC) 7 inch/178 mm (FM Series AH1, AH1-CC, AH2, AH2-CC, AH2-68) 76 mm/ inch (VdS Series AH1, AH1-CC, AH2, AH2-CC) 76 mm/ inch (LPCB Series AH1, AH2) 8 inch/20 mm (FM Series AH2-00) Maximum K-Factor of Sprinkler to be Connected to Sprinkler Reducing Nipple: K8.0 US/K115 metric for 1/2 inch/dn15 K1.0 US/K200 metric for / inch/dn20 K115 metric/k8.0 US for / inch/dn20 (VdS, LPCB) Maximum Number of 90 Bends Per Flexible Hose: Refer to the Friction Loss Data section Flexible Hose Bend Characteristics: NOTE: For out-of-plane (three-dimensional) bends, care shall be taken to avoid imparting torque on the flexible hose. 2X Bend Radius 2X Bend Radius 90 OR OR I-VICFLEX.AB_1

INTRODUCTION Victaulic VicFlex Sprinkler Fittings connect the sprinkler piping directly to the sprinkler using a flexible hose and fittings and are designed for use in hat furring channel ceiling applications. Each drop assembly comes with one flexible hose, one adapter nipple or captured coupling, one sprinkler reducing nipple, and the Style AB Bracket. IMPORTANT INSTALLATION INFORMATION Victaulic VicFlex products shall be installed according to current, applicable National Fire Protection Association (NFPA 1, 1D, 1R, etc.) standards or equivalent standards. Victaulic VicFlex products are intended to be installed in wet, dry, or preaction actuated systems. Deviations from these standards or alterations to Victaulic VicFlex products or sprinklers will void any Victaulic warranty and will impact system integrity. Installations shall meet the provisions of the local authority having jurisdiction and local codes, as applicable. Drop ceiling construction shall meet the requirements of ASTM C65 and shall be installed in accordance with ASTM C75. Victaulic VicFlex Sprinkler Fittings and Style AB Brackets shall not be intermixed with other manufacturer s flexible sprinkler products. SHORT 90 ELBOW REDUCERS ARE TYPICALLY USED WITH CONCEALED SPRINKLERS (FM, VdS, LPCB ONLY). Refer to the specific product submittal for applications and listing information. These submittals are located in Sections 10 and 0 of the Victaulic G-100 Catalog or on the Victaulic website at victaulic.com. In addition, when installing Victaulic FireLock Automatic Sprinklers with Victaulic VicFlex Sprinkler Fittings, refer to the I-0 Installation and Maintenance Instructions for details on sprinkler installation requirements. Size the piping system to provide at least the minimum required flow rate for the sprinkler system. Per NFPA requirements, flush the system to remove foreign material. Continue to flush the system until water runs clear. DO NOT install sprinkler system piping through heating ducts. DO NOT connect sprinkler system piping to domestic hot water systems. DO NOT install sprinklers and sprinkler fittings where they will be exposed to temperatures that exceed the maximum ambient temperature rating for the sprinkler and sprinkler fittings. The flexible hose shall not be bent or fluctuated up-and-down or side-to-side when it is pressurized. Flexible hose and fittings have limited flexibility* and are intended only to be installed with bends not less than their respective minimum bend radii. DO NOT install flexible hose in a straight configuration. Protect wet piping systems from freezing temperatures. If construction is altered, refer to applicable standards to determine if additional sprinklers are required. The owner is responsible for maintaining the fire protection system in proper operating condition. For minimum maintenance and inspection requirements, refer to NFPA 25 and any other applicable NFPA standards that describe the care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that shall be followed. Relocation of Victaulic VicFlex products SHALL be performed by qualified personnel familiar with the system s original design criteria, sprinkler listings/ approvals, and state and local codes (including NFPA 1 standards). Failure to relocate this Victaulic VicFlex product properly could affect its performance during a fire, resulting in serious personal injury and property damage. * Reference UL 2: Section 25.1 I-VICFLEX.AB_2

FLEXIBLE HOSE ASSEMBLY DRAWINGS Refer to pages 9 12 of this manual for flexible hose technical data. 2 Example Series AH2 Flexible Hose Shown Below 2 Example Series AH2-CC Flexible Hose Shown Below 1 1 5 Item Example Series AH2 Description Example Series AH2-CC Description 1 Flexible Hose Assembly Flexible Hose Assembly 2 Adapter Nipple Coupling Assembly Reducer (Flexible Hose to Sprinkler) Reducer (Flexible Hose to Sprinkler) Shipping Cap Identification Sleeve 5 Identification Sleeve STYLE AB BRACKET ASSEMBLY DRAWING Refer to pages 6 7 of this manual for bracket installation instructions. 5 6 1 2 6 Item Description 1 2-inch/610-mm or 8-inch/1219-mm Square Bar* 2 Center Gate Assembly with Adjustment Screw Style AB End Bracket with Wing Screw Wing Screw 5 Relocation Warning Label 6 Sheet Metal Screw (#10-2 x /8 inch) * Reference submittal document 10.85 for listing information. Square bar length is in reference to nominal ceiling grid spacing. I-VICFLEX.AB_

1-INCH/DN25 IGS CONNECTION TO THE SPRINKLER PIPING USING A SERIES AH1-CC OR SERIES AH2-CC FLEXIBLE HOSE CORRECT - IGS Groove Profile INCORRECT - Orignal Groove System (OGS) Groove Profile The Style 108 Coupling assembly of the Series AH1-CC and AH2-CC shall be used ONLY with sprinkler piping connections that are prepared to Victaulic IGS proprietary groove specifications. DO NOT attempt to install the coupling on sprinkler piping connections that are prepared to any other groove specification. Refer to Victaulic publication 25.1 for the IGS groove specification, which can be downloaded at victaulic.com. The flexible hose shall not be bent or fluctuated up-and-down or side-to-side when it is pressurized for test. Failure to follow this instruction could cause improper sprinkler operation, serious personal injury, and/or property damage. DO NOT REMOVE NUT/BOLT FOR INITIAL INSTALLATION. CHECK GASKET: Check the gasket to ensure that it is suitable for the intended service. The color code identifies the gasket grade. Refer to Victaulic publication 05.01 for the color code chart, which can be downloaded at victaulic.com. a. REFER TO THE NOTICE BELOW FOR IMPORTANT GASKET INFORMATION. NOTICE Series AH1-CC and AH2-CC flexible hoses are designed for use ONLY in fire protection systems (temperatures greater than 0 F/ 0 C). Style 108 Coupling assemblies of Series AH1-CC and AH2-CC flexible hoses are provided with the Vic-Plus gasket system. Additional lubrication is not required for the initial installation of wet pipe systems that are installed at or continuously operating above 0 F/ 18 C. Refer to Victaulic publication 05.0 for the Vic-Plus Material Safety Data Sheet (MSDS), which can be downloaded at victaulic.com. Supplemental lubrication is required for Vic-Plus gaskets only if any of the following conditions exist. If any of these conditions exist, apply a thin coat of Victaulic lubricant or silicone lubricant to the sealing lips of the gasket interior only. If the continuous operating temperature is below 0 F/ 18 C If the gasket has been exposed to fluids prior to installation If the surface of the gasket does not have a hazy appearance If the gasket is being installed into a dry pipe system If the system will be subjected to air tests prior to being filled with water If the gasket was involved in a previous installation If the gasket sealing surface of the pipe contains raised or undercut weld seams, or cracks or voids at the weld seams. Lubricated gaskets will not enhance sealing capabilities on adverse pipe conditions. Pipe condition and pipe preparation shall conform to the requirements listed in product installation instructions. 1. DO NOT DISASSEMBLE THE COUPLING: The Style 108 Coupling assembly of the Series AH1-CC and AH2-CC is designed so that the installer does not need to remove the bolt and nut for installation. This design facilitates installation by allowing the installer to directly insert the sprinkler piping s grooved end into the coupling. 2. CHECK GROOVED END OF SPRINKLER PIPING: The outside surface of the sprinkler piping, between the groove and the end of the sprinkler piping, shall be smooth and free from indentations, projections, weld seams, and roll marks to ensure a leak-tight seal. All oil, grease, loose paint, dirt, and cutting particles shall be removed. The sprinkler piping s outside diameter ( OD ), groove dimensions, and maximum allowable flare diameter shall be within the tolerances published in current Victaulic IGS specifications, publication 25.1, which can be downloaded at victaulic.com. Never leave a Style 108 Coupling assembly of a Series AH1-CC or AH2-CC partially assembled. A partially assembled coupling poses a drop or burst hazard during testing. Keep hands away from the opening of the coupling when attempting to insert the grooved sprinkler piping into the coupling. Failure to follow these instructions could result in serious personal injury and property damage. I-VICFLEX.AB_

I-VICFLEX.AB / Victaulic VicFlex Style AB Sprinkler Fitting / Installation Instructions GOOD. ASSEMBLE JOINT: Assemble the joint by inserting the grooved end of the sprinkler piping into the opening of the coupling. The grooved sprinkler piping shall be inserted into the coupling until contact with the center leg of the gasket occurs. A visual check is required to ensure that the coupling keys align with the groove in the sprinkler piping. BAD The nut shall be tightened until metal-to-metal c ontact occurs at the bolt pads. Failure to follow this instruction could cause joint failure, resulting in death or serious personal injury and property damage. 6. INSPECT PADS: Visually inspect the bolt pads at each joint to ensure that metal-to-metal contact is achieved in accordance with step 5. NOTICE Refer to the instructions on page 9 for disassembly and reassembly requirements. 5. TIGHTEN NUT: Using an impact wrench or standard socket wrench with an 11/16-inch/17-mm deep well socket, tighten the nut until metal-to-metal contact occurs at the bolt pads. Verify that the housings keys engage the sprinkler piping s groove completely. I-VICFLEX.AB_5

CONNECTION TO THE SPRINKLER PIPING USING AN ADAPTER NIPPLE AND A SERIES AH1, AH2, AH2-00, OR AH2-68 FLEXIBLE HOSE The flexible hose shall not be bent or fluctuated up-and-down or side-to-side when it is pressurized for test. Failure to follow this instruction could cause improper sprinkler operation, serious personal injury, and/or property damage. INSTALLATION OF THE SPRINKLER REDUCING NIPPLE ONTO THE FLEXIBLE HOSE TURN CONNECTION NUT ONLY 1. Apply pipe joint compound or PTFE thread sealant tape to the tapered threads of the adapter nipple, in accordance with the pipe joint compound or tape manufacturer s instructions. Using a pipe wrench, tighten the adapter nipple into the sprinkler piping. 1. Confirm that the seal inside the nut of the flexible hose is in place and is free from damage prior to installation. Connect the nut to the sprinkler reducing nipple. SHORT 90 ELBOW REDUCERS ARE TYPICALLY USED WITH CONCEALED SPRINKLERS (FM AND VdS ONLY). DO NOT use pipe joint compound or PTFE thread sealant tape on the fine threads of the sprinkler reducing nipple. The seal inside the nut of the flexible hose provides the leak-proof connection. Tighten the connection nut to a torque of 0 ft-lbs/5 N m (approximately 1/2 to / of a turn past hand-tight). NOTE: To prevent damage to the seal, tighten the assembly by applying torque only to the connection nut and DO NOT exceed the specified torque. INSTALLATION FOR ASTM C65 HAT FURRING CHANNEL CEILING SYSTEMS INSTALLED IN ACCORDANCE WITH ASTM C75 STANDARDS 1. Loosen the wing screw on top of each end bracket assembly to allow the end brackets to slide on the square bar. 2. Confirm that the seal inside the nut of the flexible hose is in place and is free from damage prior to installation. Connect the nut to the adapter nipple, as shown above. DO NOT use pipe joint compound or PTFE thread sealant tape on the threads of the adapter nipple. The seal inside the nut of the flexible hose provides the leak-proof connection. Tighten the connection nut to a torque of 0 ft-lbs/5 N m (approximately 1/2 to / of a turn past hand-tight). NOTE: To prevent damage to the seal, tighten the assembly by applying torque only to the connection nut and DO NOT exceed the specified torque. 2. Attach the end brackets to the ASTM C65 hat furring channel ceiling system installed in accordance with ASTM C75 standards. Verify that the end brackets engage the hat furring channels, as shown above. Adjust the Style AB Bracket assembly to the appropriate location on the hat furring channel. I-VICFLEX.AB_6

. Hand-tighten the wing screw on the side of each end bracket until the end bracket is secured to the hat furring channels. 6. Verify that the wing screw on the side of each end bracket is hand-tightened until the end bracket is secured to the hat furring channels. Adjustment Screw. Tighten the wing screw on top of each end bracket assembly to a torque of 6 inch-lbs/ N m (approximately 1/2 to / of a turn past hand-tight) to secure the end brackets to the square bar. 7. Move the center gate assembly of the Style AB Bracket to the desired location. Using a #2 square recessed drive bit, loosen the adjustment screw, then push open the center gate assembly. Slide the sprinkler reducing nipple into the center gate assembly. NOTE: The adjustment screw of the center gate assembly is staked to resist removal. 5. Using a 5/16-inch hex drive bit, tighten the #10-2 x /8-inch sheet metal screw (provided with the bracket) through the two locations on each end bracket and into the hat furring channels. 7a. Close the gate around the sprinkler reducing nipple. The gate will snap together tightly around the sprinkler reducing nipple. Using a #2 square recessed drive bit, tighten the adjustment screw to a torque of 75 inch-lbs/8.5 N m (until adjustment screw makes metal-to-metal contact with bottom of gate). NOTE: The sprinkler reducing nipple can be adjusted after the drywall is installed by using the adjustment screw on the center gate assembly. SPRINKLER INSTALLATION: Install the sprinkler by following the manufacturer s installation instructions. For Victaulic sprinklers, refer to the I-0 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Instructions. I-VICFLEX.AB_7

INSTRUCTIONS FOR REASSEMBLY OF A SERIES AH1-CC OR SERIES AH2-CC FLEXIBLE HOSE Verify that the system is depressurized and drained completely before attempting to disassemble a Series AH1-CC or AH2-CC Flexible Hose from the sprinkler piping. Failure to follow this instruction could result in death or serious personal injury and property damage. 1. Verify that the system is depressurized and drained completely before attempting to disassemble a Series AH1-CC or AH2-CC Flexible Hose from the sprinkler piping. 2. Loosen the nut of the Style 108 Coupling assembly to permit removal from the sprinkler piping.. Remove the nut, bolt, gasket, and linkage from the Style 108 Coupling housings. Inspect all components for damage or wear. If any damage or wear is present, replace with new Victaulicsupplied components. NOTE: Replacement gaskets shall be of the same grade that is suitable for the intended service.. Verify that the outside surface of the sprinkler piping, between the groove and the end of the sprinkler piping, is smooth and free from indentations, projections, weld seams, and roll marks to ensure a leak-tight seal. All oil, grease, loose paint, dirt, and cutting particles shall be removed. The sprinkler piping s outside diameter ( OD ), groove dimensions, and maximum allowable flare diameter shall be within the tolerances published in current Victaulic IGS specifications, publication 25.1, which can be downloaded at victaulic.com. 7. REASSEMBLE COUPLING ONTO FLEXIBLE HOSE: Place the lubricated gasket onto the inlet end of the flexible hose, then place the Style 108 Coupling housings over the gasket. Verify that the gasket is seated in the gasket pocket of the housings and that the housings' keys engage with the spacer. 8. INSTALL LINKAGE: Install the linkage onto the housings, as shown above. Spacer 5. Verify that the spacer is oriented on the inlet end of the flexible hose, as shown above. CAUTION A thin coat of Victaulic Lubricant or silicone lubricant shall be used to prevent the gasket from pinching/tearing during reassembly. Failure to use a compatible lubricant will cause gasket damage, resulting in joint leakage and property damage. 9. INSTALL HARDWARE: Install the bolt through the housings. Thread the nut onto the bolt until the top of the nut is flush with the end of the bolt, as shown above. Verify that the gasket remains seated in the gasket pocket of the housings and that the housings' keys engage with the spacer. 10. Follow all steps on pages 5 of this instruction sheet to complete the assembly. 6. LUBRICATE GASKET: Apply a thin coat of Victaulic Lubricant or silicone lubricant to the gasket sealing lips and exterior. It is normal for the gasket surface to have a hazy white appearance after it has been in service. I-VICFLEX.AB_8

TECHNICAL DATA FOR FLEXIBLE HOSES The following section provides friction loss information for flexible hoses that can be used with Style AB Brackets. It is the system designer s responsibility to verify suitability of stainless steel flexible hose for use with the intended fluid media within the piping system and external environment. The effect of chemical composition, ph level, operating temperature, chloride level, oxygen level, and flow rate on the stainless steel flexible hose shall be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in death or serious personal injury and property damage. I-VICFLEX.AB_9

SERIES AH1 AND AH1-CC FLEXIBLE HOSE FRICTION LOSS DATA (FM AND UL) Model AH1-1 AH1-CC-1 AH1-6 AH1-CC-6 AH1-8 AH1-CC-8 AH1-60 AH1-CC-60 AH1-72 AH1-CC-72 Length of Flexible Hose inches/mm 1 790 6 915 8 1220 60 1525 72 180 Outlet Size# Equivalent Length of 1-inch/DN25 Schedule 0 Pipe feet/meters Maximum Number of 90 Bends inches/metric FM* UL FM UL 1/2 5.8 52.0 DN15 16. 15.9 /. 55.0 2 DN20 1.5 16.8 1/2 6.7 6.0 DN15 19. 19.2 / 55.5 66.0 DN20 16.9 20.1 1/2 87.9 78.0 DN15 26.8 2.8 / 8.0 80.0 DN20 25. 2. 1/2 112.2 88.0 DN15.1 26.8 / 110. 90.0 DN20.6 27. 1/2 16.5 112.0 DN15 1.6.1 / 17.9 118.0 DN20 2.0 6.0 2 5 * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) -inch/76-mm minimum bend radius (tested and UL Listed only with standard 5 /-inch/16-mm length straight reducer) # /-inch/dn20 outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.95 A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 270 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.85. NOTE: Differences in equivalent lengths are due to varying test methods, per UL 2 and FM 167 standards. Refer to these standards for additional information regarding friction loss test methods. SERIES AH2 AND AH2-CC FLEXIBLE HOSE FRICTION LOSS DATA (FM AND UL) Model AH2-1 AH2-CC-1 AH2-6 AH2-CC-6 AH2-8 AH2-CC-8 AH2-60 AH2-CC-60 AH2-72 AH2-CC-72 Length of Flexible Hose inches/mm 1 790 6 915 8 1220 60 1525 72 180 Outlet Size# Equivalent Length of 1-inch/DN25 Schedule 0 Pipe feet/meters Maximum Number of 90 Bends inches/metric FM* UL FM UL 1/2 2.5 16.0 DN15 7.2.9 / 1.9 17.0 2 DN20.5 5.2 1/2 27.8 21.0 DN15 8.5 6. / 19. 2.0 DN20 5.9 7.0 1/2 8.2 2.0 DN15 11.6 9.8 / 0. 7.0 DN20 9.2 11. 1/2 2. 6.0 DN15 12.9 1.0 /.9 6.0 DN20 10. 1.0 1/2 6.6 55.0 DN15 1.2 16.8 / 7.5 5.0 DN20 11. 16.2 2 5 8 10 12 * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) 2-inch/50-mm minimum bend radius (tested and UL Listed only with standard 5 /-inch/16-mm length straight reducer) # /-inch/dn20 outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.85 A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 270 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.85. NOTE: Differences in equivalent lengths are due to varying test methods, per UL 2 and FM 167 standards. Refer to these standards for additional information regarding friction loss test methods. I-VICFLEX.AB_10

SERIES AH2-00 FLEXIBLE HOSE FRICTION LOSS DATA (FM) Model AH2-00-1 AH2-00-6 AH2-00-8 AH2-00-60 AH2-00-72 Length of Flexible Hose inches/mm 1 790 6 915 8 1220 60 1525 72 180 Outlet Size# inches/metric Equivalent Length of 1-inch/DN25 Schedule 0 Pipe feet/meters* 1/2 2.5 DN15 7.2 / 1.9 DN20.5 1/2 27.8 DN15 8.5 / 19. DN20 5.9 1/2 8.2 DN15 11.6 / 0. DN20 9.2 1/2 2. DN15 12.9 /.9 DN20 10. 1/2 6.6 DN15 1.2 / 7.5 DN20 11. Maximum Number of 90 Bends * 8-inch/20-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) # /-inch outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.8 A higher number of bends may be permitted, provided the sum of degrees is equal to or less than the total maximum allowable degrees of bends (e.g. Two 90 bends equal 180. Three 90 bends equal 270 ). The minimum bend radius and maximum number of 90 offset (bends), stated in these installation instructions, refer to the final installed condition of the hose. For friction loss data for elbows, refer to Victaulic submittal 10.85. NOTE: Differences in equivalent lengths are due to varying test methods, per the FM 167 standard. Refer to this standard for additional information regarding friction loss test methods. SERIES AH2-68 FLEXIBLE HOSE FRICTION LOSS DATA (FM) Model AH2-68 Length of Flexible Hose inches/mm 28 711 Outlet Size# inches/metric Equivalent Length of 1-inch/DN25 Schedule 0 Pipe feet/meters* 1/2 22.2 DN15 6.8 / 1.1 DN20.9 2 2 Maximum Number of 90 Bends * 7-inch/178-mm minimum bend radius (tested with standard 5 /-inch/16-mm length straight reducer) # /-inch outlet data shown with K1.0 - For other K-factor friction loss data, refer to Victaulic submittal 10.85 For friction loss data for elbows, refer to Victaulic submittal 10.85. NOTE: Differences in equivalent lengths are due to varying test methods, per the FM 167 standard. Refer to this standard for additional information regarding friction los test methods. SERIES AH1, AH1-CC, AH2, AND AH2-CC FLEXIBLE HOSE FRICTION LOSS DATA (VDS) Length of Flexible Hose mm/inches 790 1 Outlet Size Metric/inches DN20// Maximum Number of 90 Bends at 76.2-mm/-inch Series AH1 and AH1-CC Equivalent Length of Steel Pipe in meters/feet According to EN 10255 DN 20 (26,9 x 2,65).0 12.9 Series AH2 and AH2-CC Equivalent Length of Steel Pipe in meters/feet According to EN 10255 DN 25 (,7 x,25) 5.5 18.0 1 915 6 DN20//.6 15.0 6. 21.0 1220 8 DN20// 6.1 20.0 8.5 27.9 1525 60 DN20// 7.6 25.0 10.7 5.1 180 72 DN20// 9.2 0.0 12.8 2.0 Flexible Hoses are VdS Approved for use in wet systems only. Only VdS Approved pendent spray sprinklers of 10-mm, 15-mm, and 20-mm nominal diameters with K-factors of 57, 80, and 115 shall be used. Tested with a 5 /-inch/16-mm length straight reducer. NOTE: No specific VdS Approval is required for manufacturers of hat furring channel ceiling systems. I-VICFLEX.AB_11

INSTALLATION INSTRUCTIONS I-VICFLEX.AB Victaulic VicFlex Style AB Sprinkler Fitting for Hat Furring Channel Ceiling Systems SERIES AH1 AND AH2 FLEXIBLE HOSE FRICTION LOSS DATA (LPCB) Series AH1* Series AH2** Length of Flexible Hose mm/inches Outlet Size Metric/inches Maximum Number of 90 Bends at 76.2-mm/-inch Equivalent Length of Steel Pipe in meters/feet According to EN 10255 DN 25 (,7 x,25) Equivalent Length of Steel Pipe in meters/feet According to EN 10255 DN 25 (,7 x,25) 790 1 DN20// 2 1.6.6 1.8 6.0 915 6 DN20// 16.9 55..6 11.9 1220 8 DN20// 19.9 65.1. 1.0 1525 60 DN20// 2.5 80.2.1 1.6 180 72 DN20// 28.5 9. 5.5 18.1 * Hose Type 2 and Size: DN20/0.8-inch Nominal ID, per LPS 1261 ** Hose Type 2 and Size: DN25/1-inch Nominal ID, per LPS 1261 Series AH1 and AH2 Flexible Hoses are LPCB Approved for use in wet systems only. Only LPCB Approved pendent spray sprinklers of 10-mm, 15-mm, and 20-mm nominal diameters with K-factors of 57 and 80 shall be used. Tested with a 5 /-inch/16-mm length straight reducer. For complete contact information, visit victaulic.com I-VICFLEX.AB 708 REV G UPDATED 10/2017 Z000AB000 VICTAULIC AND VICFLEX ARE REGISTERED TRADEMARKS OR TRADEMARKS OF VICTAULIC COMPANY AND/OR ITS AFFILIATED ENTITIES IN THE UNITED STATES AND/OR OTHER COUNTRIES. 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED.