GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

Similar documents
GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

INTERNATIONAL STANDARD

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Test Report. Test Requested : Test for compliance with clauses 8 and 9 of IEC : 1993+A1+A2. Page 1 of 6

American National Standard for Safe Use of Lasers

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

West Virginia University Laser Safety Program

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

AS/NZS IEC :2014

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

Contains Nonbinding Recommendations. Draft Not for Implementation

b. Laser Mishap. Any unplanned or unexpected event causing material loss or damage or causing personnel injury from laser use.

Northern Illinois University Laser Safety Manual

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Photobiological safety of lamps and lamp systems

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

NX7535 Series DESCRIPTION NX7535AN-AA FEATURES NX7535BN-AA

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Policy Redesign Project. Laser safety. Table of Contents

ANSI Z136.1-CDV Status on Updates for Next Revision & Work by TSC-4 Committee on Control Measures and Training

100 Ft. LASER DISTANCE METER

Certified Laser Safety Officer. Exam Reference Guide

Laser Safety Per Söderberg

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

FOCUS ON LASERS. Philip Campbell RADIATION SAFETY: Principles, Practice, and Emerging Issues March 2018

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

safety & regulatory information

TS105-10L5.5MM Thermopile Sensor

Lasers and Laser Safety

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Rice University Laser Safety Manual

American National Standard

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Duct Mount. Installation Instructions

Radiation and Laser Safety

Ref No: Date: September 30, 1994 ELECTRICAL AND ELECTRONIC EQUIPMENT NO. 2

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

American National Standard

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

Rutgers Environmental Health and Safety (REHS)

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

Laser Safety Manual. [Section 2.0] - Procedures: Administration and Evaluation

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

LASER SAFETY BARRIER

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

UC IRVINE LASER SAFETY PROGRAM

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

*For inquiries and questions about lasers, see the Yellow-Page.

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

LASER DIODE NX7637BF-AA

CD6102 / CD6102 OC / CD6102-2

Laser Safety for Laboratory Users

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Fibrlok II 2529 Universal Optical Fiber Splice

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

Dickeya solani survey of seed crops in England & Wales 2011

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification.

HFX Fiber Optic Component 50 Mbps, 650 nm LED

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

This document is a preview generated by EVS

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Laser Safety Program

This is a preview - click here to buy the full publication

American National Standard

MicrOTDR. Optical Fault Locator. User Manual

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

FIRERAY 5000 range USER GUIDE

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

FlexScan OTDR With SmartAuto and LinkMap

LASER SAFETY PLAN OPHTHALMOLOGY

Bioenvironmental Engineering Site Assessment I

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

NEED FOR LASER SAFETY

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Laser Institute of America. Laser Safety Guide. Eleventh Edition Prepared by LIA Laser Safety Committee

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

TYPE APPROVAL CERTIFICATE

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

Draft ES V1.1.1 ( )

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

NG4access ODF Platform Standard Chassis Installation Manual

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

Laser Safety. Occupational Health and Safety

G4 Pulsed Fiber Laser

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

Optical Measurement Techniques for LED Clusters and LED Safety

Light Detection and Ranging LiDAR and the FAA FAA Review and Reclassification of LiDAR systems

Laser Safety Guide March 29th, 2016

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

OWNERS MANUAL OPERATION GUIDE

Transcription:

CONSUMER PRODUCTS SERVICES DIVISION Date Received: May 25, 2016 Page 1 of 7 GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD LAIMEI INDUSTRIAL ZONE,CHENGHAI DISTRICT, SHANTOU, GUANGDONG Sample Description: RC TOYS Vendor: N/A Sample Size: N/A Manufacturer: N/A Style No(s): 3713(3611),3712(3610) Buyer: N/A SKN/SKU No.: N/A Labeled Age Grade: AGE 8+ PO No.: N/A Appropriate Age Grade: NOT REQUESTED Ref #: N/A Client Specified Age 8+ Country of Origin: CHINA Grade: Tested Age Grade: OVER 8 YEARS OF AGE Country of Destination: N/A UPC Code: N/A Assortment No.: N/A Rated voltage: 3.0V TX-CONTROLLER EXECUTIVE SUMMARY: The sample(s) was tested to the following requirement(s) and the data provided is for informational purposes only: - The classification in accordance with standard EN 60825-1. Note: At the requested of the client, EN 60825 testing was performed for item 3713. BUREAU VERITAS SHENZHEN CO., LTD. NL / cc Lung Cheong Ming, Nick Assistant Manager Electrical Department Toys, Premiums & Juvenile Products Division Bureau Veritas Shenzhen Co., Ltd 4/F, Block B, Minlida Industrial Building, 4th Zone of Honghualing Industrial Park, Xili Town, Nanshan District, Shenzhen, Guangdong, P.R.C. Tel: 86-755-86185200 Fax: 86-755- 86185206 www.bureauveritas.com/cps This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/cps and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.

Page 2 of 7 RESULTS: SUMMARY OF TEST RESULTS The sample is classified as Class 1 Laser Product according to EN60825-1. Test Executed Test Standard Limit Tests for Classification of Laser Products Sec. 8, Sec. 9, EN 60825-1: 1994 + A11: 1996 + A2: 2001 + A1: 2002 Table 1, EN 60825-1: 1994 + A11: 1996 + A2: 2001 + A1: 2002

Test method and equipment: Page 3 of 7 The following test equipment are applied for the tests: Equip. No Equipment Name Brand Name Model M006003L Digital Light Meter TES TES-1336A M006004L Digital Light Meter Sper 840020 Scientific M008005L Digital Caliper (0-12 ) Mitutoyo CD-12 C M008006L Digital Caliper (0-12 ) Mitutoyo CD-12 C M015003L Stainless Steel Ruler (0-12 ) Endo Keiki NIL M019001L Optical Sensor Head Advantest Q82214 M019002L Optical Power Meter + Optical Sensor Interface Unit Advantest Q8221 / Q82203 M019003L Optical Spectrum Analyzer Advantest Q8341 M019004L Optical Sensor Head Advantest Q82214 M019005L Optical Power Meter + Optical Sensor Interface Unit Advantest Q8221 / Q82203 T031001L Laser Test Fixture + Sample Platform NIL NIL T032001L 7mm Sensor Aperture Stop NIL NIL T032003L 0.5mm Field Stop Aperture NIL NIL T032004L 5mm Field Stop Aperture NIL NIL T033001L Filter (Yellow) Lee Filter 101 T033002L Filter (Green) Lee Filter 124 T033003L Filter (Red) Lee Filter 182 T033004L Filter (Blue) Lee Filter 195 The measurements are carried out with the measurement set up following Section 9 of EN 60825-1. The measurement condition 2 specified in Section 9.3 and Table 10 of EN 60825-1 is adopted. Description of the lasers or LEDs under test: Source No. Feature LED 1 CW / Single-λ / red led, controller

RESULTS: Page 4 of 7 I) TESTS DURING OPERATION Basic Parameters of the lasers or LEDs Single-wavelength source: Parameters Unit Led 1 Color of the laser/led (e.g. Red / Amber / Yellow / Green / Blue, etc.) Wavelength (λ) measured / Given by manufacturer (nm) Red 629 Time Base estimated (sec) 100 Apparent source size (a) measured Angular subtense (α) estimated Is the laser or LED continuous wave or pulsed? (mm) (mrad) 0.2 1.95 CW Break Point (T 2) (second) 10.11

RESULTS: Page 5 of 7 For continuous wave (CW) lasers or LEDs: Note: a laser or LED operating with a continuous output for a period equal to or greater than 0.25 second. A) TESTS AGAINST RETINAL PHOTOCHEMICAL HAZARD (RPH): Single-wavelength source: Parameters Unit Led1 Limiting angle of acceptance (γ p) (mrad) N/A Measurement aperture (d) (mm) N/A Measurement distance (r) (mm) N/A Exposure time (t) (sec) N/A Radiant power (P) (µw) N/A Radiant energy (Q) (µj) N/A The corresponding RPH AEL for Class 1 Laser <µw or µj> N/A

RESULTS: Page 6 of 7 B) TESTS AGAINST RETINAL THERMAL HAZARD (RTH): Single-wavelength source: Parameters Unit Led1 Angle of acceptance (γ) (mrad) 1.95 Measurement aperture (d) (mm) 7 Measurement distance (r) (mm) 15.53 Exposure time (t) (sec) 100 Radiant power (P) (µw) 0.87 Radiant energy (Q) (µj) N/A The corresponding RTH AEL for Class 1 Laser µw 511.16 N/A = Not Applicable III) TESTS UNDER FAULT CONDITIONS Details: No electronic component can be shore-circuited.

Page 7 of 7 RESULTS: END