An Urgent Bulletin from CSA Group Hazardous Locations Products No. 28 (Supersedes Electrical Certification Notice No. 544A) Date: January 3, 2018 See Attachment 1 for Effective Dates. See Attachment 1 for Application Due Dates Announcing: Publication of CSA C22.2 No 213-2017, Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations, superseding CSA C22.2 No 213-2016 and replacement dates for CSA C22.2 No 213-M1987 See Attachment 2 for affected Class Numbers. To purchase the Standard, visit us at www.shop.csa.ca Who is affected? Manufacturers of nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location. What do you do? 1. CSA Group Service Delivery staff will contact you to address compliance with each revision as applicable to the product designs covered in your affected Certification Reports. In addition to updates to your Certificate(s) of Compliance & Report(s), testing may be required to comply with these revisions. 2. Please respond within thirty (30) days of receiving CSA Group s Application for CSA Certification Services and Quotation communication. You must respond no later than the application dates listed in Attachment 1 in order to guarantee the update to your certification is completed by the corresponding effective dates shown in the same attachment. If testing is needed, we will inform you of the samples required. Approvals: See attachment 3 Major Revisions: See attachment 4 Background and Rationale: See attachment 5 For questions specific to your file or products contact your CSA Group technical staff associate. Go to http://www.csagroup.org/services/testing-andcertification/product-listing/ and enter your Master Contract # and the class numbers associated with this Notice to determine which of your products are affected. For technical questions on this Certification Notice Contact Dorin Stochitoiu by phone 416-747-2324, fax 416-747-4149 or e-mail dorin.stochitoiu@csagroup.org The standard edition or amendments announced in this Notice may be used for certification as of the date of issue of this Notice. The Effective date in this Notice is the date on which the current requirements, applicable to Certified products listed in the affected class numbers, expire and the standard edition or amendments announced in this Notice become the only requirements that may be used for certification. In the event that currently certified products do not comply with the latest requirements outlined in this Notice after the effective date, the certification of such models may be discontinued. Visit us at www.csagroup.org where you can click on "Contact Us" for the online phone listing of our Offices and Partners. DQD 529.01 Rev 2017-10-03 CSA Group 2016. All rights reserved. Ref No: N17-137 Page 1 of 6
ATTACHMENT 1 Effective Dates Unless superseded by a further notice the following effective dates apply: New Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location Between now and December 31, 2020, the following CSA Standards apply for certification of new Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location: (i) CSA C22.2 No. 213-M1987; (ii) CSA C22.2 No. 213-2016; (iii) CSA C22.2 No. 213-2017 After December 31, 2020 the CSA Standard CSA C22.2 No. 213-2017, or a newer edition, applies for certification to new Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location. Existing certified Intrinsically Safe Equipment and Associated Equipment Up until December 31, 2022, the following CSA Standards apply when evaluating any revision of existing CSA certified Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location: (i) CSA C22.2 No. 213-M1987; (ii) CSA C22.2 No. 213-2016; (iii) CSA C22.2 No. 213-2017 Note: This means that the standards currently stated in the existing certifications remain applicable for the scope of revisions of existing certifications during the stated period. After December 31, 2022, the CSA Standard CSA C22.2 No. 213-2017 or a newer edition applies to existing CSA certified Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location requiring revisions. Manufacturers must make an application no later than March 1, 2022 in order to guarantee that the evaluation of the revisions their certified equipment is completed by December 31, 2022. Between now and December 31, 2027, the following CSA Standards remain valid for existing CSA certified (classified) location, without revisions of such certifications: (i) CSA C22.2 No. 213-M1987; (ii) CSA C22.2 No. 213-2016; (iii) CSA C22.2 No. 213-2017 Note: This means that the certifications already done to these standards remain valid for the period stated, providing that no revisions of such certifications are necessary. After December 31, 2027, the CSA Standard CSA C22.2 No. 213-2017 or a newer edition applies to all new (classified) location, and to any previously such CSA certified equipment. Page 2 of 6
Manufacturers must make an application no later than March 1, 2026 in order to guarantee that the evaluation to their equipment is completed by December 31, 2027. Manufacturers may make an application at any time to have their equipment evaluated to the requirements of CSA C22.2 No. 213-2017 or a newer edition. ATTACHMENT 2 Affected Class Numbers Class No: 2228 01, RADIO APPLIANCES - Transmitters and Receivers, Amateur, Commercial and Communication - For Hazardous Locations 2258 01, PROCESS CONTROL EQUIPMENT - Custom Built - For Hazardous Locations 2258 03, PROCESS CONTROL EQUIPMENT - Intrinsically Safe and Non Incendive Systems - For Hazardous Locations 2258 04, PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations 3218 01, INDUSTRIAL CONTROL EQUIPMENT - Custom Built - For Hazardous Locations 3218 02, INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Auxiliary Devices-For Hazardous Locations 3218 03, INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Magnetic - For Hazardous Locations 3218 04, INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Manual - For Hazardous Locations 3218 05, INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Miscellaneous - For Hazardous Locations 3218 06, INDUSTRIAL CONTROL EQUIPMENT - Miscellaneous Apparatus - For Hazardous Locations 3428 12, LUMINAIRES - Exit Type 1 and 2 for Hazardous Locations 3458 01, PORTABLE LUMINAIRES - For Hazardous Locations 3838 02, AGRICULTURAL EQUIPMENT, PACKAGING EQUIPMENT AND PAINT SPRAYERS - Bottling, Labeling, Packaging and Canning Machines - Haz-Loc 4818 01, SIGNAL APPLIANCES - Air - Accessories - For Hazardous Locations 4818 02, SIGNAL APPLIANCES - Audible - For Hazardous Locations 4818 03, SIGNAL APPLIANCES - Miscellaneous - For Hazardous Locations 4828 01, SIGNAL APPLIANCES - Combustible Gas Detection Instruments - For Hazardous 4828 02, SIGNAL APPLIANCES - Toxic Gas Detection Instruments - For Hazardous Locations 4828 31, SIGNAL APPLIANCES - Combustible Gas Detection Instruments - For Hazardous Locations- Components 4838 01, TELECOMMUNICATION EQUIPMENT - For Hazardous Locations 9014 01, FLAMMABLE LIQUID HANDLING EQUIPMENT - Accessories 9068 01, SCALES - For Hazardous Locations 9098 01, MISCELLANEOUS - For Hazardous Locations 1618 01, CLEANING MACHINES - For Hazardous Locations 2258 02, PROCESS CONTROL EQUIPMENT - For Hazardous Locations 2268 01, SOUND RECORDING AND REPRODUCING EQUIPMENT - For Hazardous Locations 2418 01, ELEVATOR EQUIPMENT - For Hazardous Locations 2818 01, HEATERS - Air - Stationary Type - For Hazardous Locations 2848 01, HEATERS - Industrial and Laboratory - For Hazardous Locations 2878 02, HEATERS - Miscellaneous - For Hazardous Locations 3218 09, INDUSTRIAL CONTROL EQUIPMENT - Special (Custom) Industrial Control Assemblies for Hazardous Locations 3228 01, VALVES - For Hazardous Locations 3228 02, VALVES - Actuators - For Hazardous Locations 3238 01, SWITCHES - Automatic - Pressure Type - For Hazardous Locations 3818 01, FANS AND BLOWERS - For Hazardous Locations Page 3 of 6
3838 03, AGRICULTURAL EQUIPMENT, PACKAGING EQUIPMENT AND PAINT SPRAYERS - Sprayers - Paint - Haz-Loc 3858 01, LIQUID PUMPS - For Hazardous Locations 4218 01, ROTATING EQUIPMENT - Electric Generating Plants - Haz-Loc 4218 02, ROTATING EQUIPMENT - Motors and Generators - Custom Built - Haz-Loc 4228 01, MOTORS AND GENERATORS - For Hazardous Locations 4238 01, DRIVE UNITS - Internal Combustion Engine Type - For Hazardous Locations 4628 01, PANELBOARDS - For Hazardous Locations 4658 01, SWITCHES - Miscellaneous - For Hazardous Locations 4658 02, SWITCHES - Enclosed - For Hazardous Locations 4868 01, TEMPERATURE-INDICATING AND REGULATING EQUIPMENT - For Hazardous Locations 4878 01, TIME INDICATING AND RECORDING APPLIANCES - For Hazardous Locations 5318 01, POWER SUPPLIES - For Hazardous Locations 5418 01, TRANSFORMERS - For Hazardous Locations 5418 02, TRANSFORMERS - Lighting - For Hazardous Locations 5418 03, TRANSFORMERS - Power - For Hazardous Locations 6248 01, SWITCHES - Snap - For Hazardous Locations 6718 01, DOOR OPERATING UNITS - For Hazardous Locations 8728 01, LABORATORY EQUIPMENT - For Hazardous Locations 9048 01, CRANES AND HOISTS - For Hazardous Locations 9088 01, QUALIFIED FACILITIES FOR THE REPAIR OF HAZARDOUS LOCATIONS EQUIPMENT - Motors and Generators ATTACHMENT 3 Approvals Approvals of Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location certified to CSA C22.2 No. 213-M1987 and CSA C22.2 No. 213-2016 are affected by the effective dates listed in Attachment 1. Nonincendive electrical equipment for use in Class I, Division 2, hazardous locations certified to CSA C22.2 no 213-M1987, and that were also certified to standard UL 1604, will be subjected to the same effective dates with respect to US standard which is superseded by ANSI/UL121201:2017 or newer edition of this standard that may be available at the time of approvals update. (classified) location certified to CSA C22.2 No. 213-2016 or CSA C22.2 No. 213-M1987, and that were also certified to 2015 or older version of ANSI/ISA 12.12.01, will be subjected to the same effective dates with respect to US standard which is superseded by ANSI/UL 121201:2017 or newer edition of this standard that may be available at the time of approvals update. (classified) location certified to CSA C22.2 No. 213-2016 or CSA C22.2 No. 213-M1987, that were also certified to older versions of FM 3611, will be subjected to the same effective dates with respect to US standard which is superseded by FM 3611:2016 or ANSI/UL 121201:2017 or newer edition of these standards that may be available at the time of approvals update. Where applicable, equipment evaluated to the requirements of CSA C22.2 No. 213-2017, or newer edition of this standard that may be available at the time of approvals update for Canada, can be also evaluated for US to FM 3611:2016 or ANSI/UL 121201:2017 or newer edition of these standards that may be available at the time of approvals. Page 4 of 6
ATTACHMENT 4 Major Revisions There are no major revisions between the latest edition CSA C22.2 No. 213-2017 and previous edition CSA C22.2 No. 213-2016. Minor corrections, updates of references, clarifications and extensions of the standard are covered under the latest edition, as for example: - Extension to include requirements for oil-immersed equipment - Extension to acknowledge for Gc and Dc protections and Class I, Zone 2 AEx and Zone 22 AEx protections respectively - Clarification that optional zone marking is for US only There are some significant differences between CSA C22.2 No. 213-2017 when compared with standards CSA C22.2 No. 213:M1987 and there are also some differences in interpretations of applicability of concepts and possible stringency of their applications, as for example: - Requirement for continuous operation temperature rating for gasket seals and poured seals for sealing devices. - Requirements for testing of make-break devices are clearly specified and are different from the test requirements applied for non-incendive components. - Pass-fail criteria for spark ignition test for non-incendive components is clarified, no ignition within the tested component must be confirmed - Non-incendive circuits evaluation requires that up to 110% voltage rating be consider for associated line connected supplying equipment - Extension to cover equipment designated for Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) location Following table is the summary of the processes that shall be expected when the a manufacturer request is made for updating existing certifications from the older editions of CSA C22.2 no 213 standard to the latest edition, as per subject to this notice, to be upgraded to the latest edition of CSA C22.2 no 2013:2017: Applicable requirement listed in the existing CSA report CSA C22.2 No. 213-2016 CAN/CSA C22.2 No. 213-M1987 Construction review Paperwork construction review expected to the latest edition Full construction review expected to the latest edition Tests In general, no additional testing is expected Testing may be necessary for existing certified products where make-break devices or components may have been previously evaluated using the tests for non-incendive components. Testing may be necessary for existing certified products incorporating nonincendive components where the pass-fail criteria used was different than one clarified in the latest edition of the standard Page 5 of 6
ATTACHMENT 5 Background and Rationale Standard CSA C22.2 No. 213-2017, Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations is harmonized with ANSI/UL 121201-2017, Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations The advantage of using a harmonized standard for Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations streamlines the certification process, as one single set of requirements can be used for certification in multiple countries (i.e. Canada and US) CSA C22.2 No. 213-2017 is the latest edition of this CSA standard harmonized with the edition of ANSI/US counterpart standard, an explanatory recapitulation of current and past-harmonized editions is as following: Canadian publication US publication Comments CSA C22.2 No. 213-2016 ANSI/ISA 12.12.01:2015 ANSI/ISA 12.12.01:2015 publication indicates harmonization with CSA C22.2 No. 213-2015, but in fact CSA published the harmonized edition of the standard in 2016. CSA C22.2 No. 213-2016 publication indicates harmonization with ANSI/ISA 12.12.01:2016, but in fact ANSI/ISA has already published the said edition of the standard in 2015. CSA C22.2 No. 213-2017 ANSI/UL 121201:2017 Compared with previous edition US edition of the standard Includes change of the standard editorial ownership form ISA to UL Page 6 of 6