Softcool evaporative cooling

Similar documents
Technical Development Program

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Plastic plate heat exchanger

Colt CoolStream Adiabatic Cooling & Ventilation System

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

Evaporative Cooling products

IntrCooll. Cool large buildings at 80% lower running costs

SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

RoofPak Applied Rooftop Systems

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Colt CoolStream Evaporative Cooling & Ventilation System

Air-Handling System Cooling Options

The regenerative cooling system. Ka 2 O. Co-funded by the Eco-innovation Initiative of the European Union

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

The ultimate in air handling units: directly and indirectly fired

REFRIGERATED AIR DRYERS

Brazed Plate Heat Exchanger

Refrigeration dryers DW 2-504

Brazed Plate Heat Exchanger

Functional sections of air handling units

PDF Created with deskpdf PDF Writer - Trial ::

Venturi wet scrubber VDN Separation of combustible, explosive, humid and adhesive dusts

HEATING AND VENTILATION

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

1.1 This section applies to air handling units for HVAC Systems.

REFRIGERATION PRODUCTS

Oil-injected rotary screw compressors GA GA

Plant Growth Chamber MPGR14

CL64T INDUSTRIAL TOTE WASHER

T F E

The ultimate in air handling units: directly and indirectly fired

WATER WITH QUALITY. Hygienic Water Treatment for Humidification Systems. Humidification and evaporative cooling

JCseries EVAPORATIVE CONDENSER. engineering data

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Desiccant Dehumidifier

Technical specifications

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

CONTACT US. For more information,

Models. Options. Standard Features. LoH 2 O

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

CLIMACIAT AIR COMPACT

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Performance Optimization of the Evaporative Condenser Design

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Air-Handling System Cooling Options

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Quality Heat Exchangers

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

LTG High Pressure Humidifier and Airwasher

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

StorMaxx CTEC Series Tanks

Pool dehumidification. Airpool+

Refrigerant air dryers. FD series ( l/s, cfm)

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Quality Heat Exchangers

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

SECTION AIR COILS

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units)

Refrigeration dryers DW 2-504

FUNCTION DESCRIPTION. Air - Humidifier / Air - Washer

The ultimate in air handling units: directly and indirectly fired

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

CL64eN-BAS DISHWASHER

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CL44eN-BAS DISHWASHER

C22FC Bulletin # October 1993 Supersedes May 1993

WALL-MOUNT HEAT PUMPS - (60HZ)

C22 Bulletin # October 1993 Supersedes May 1993

EVAPORATIVE COOLER PUMPS

Transcription:

2014US - 4.1 Softcool Softcool evaporative cooling Contents Page 2 3 6 7 Contents Softcool description Description of the design and function Use of rainwater Engineering information POLYBLOC USA - Lancaster, PA - Phone 717-299-5679 - info@usa.com - www.usa.com

2014US - 4.2 Softcool Softcool Indirect evaporative cooling Softcool is an environmentally friendly alternative to traditional cooling systems. Without any refrigerant the supply air can be cooled up to 22 F. In addition to this the integrated plate heat exchanger is used for heat recovery in winter. Softcool s optimised moistening of the heat exchanger in the exhaust air cools the supply air very effectively. 1 gal of water results in 6464 BTUH cooling power without humidification of the supply air. The adiabatic (indirect evaporative) cooling works by spraying a fine water film on the exhaust air side onto the hydrophilic coated surface of the heat exchanger. When this evaporates in the heat exchanger, the supply air is cooled (see psychometric chart). The main advantages: Significant energy savings in summer and winter Reduction of supply air temperature by 18 F or more without refrigerants The electrical consumption is only a fraction of the consumption in conventional cooling systems Low investment costs due to double function (cooling and heat recovery) Low maintenance costs: the automatic cleaning function keeps the surface of the PHE clean, which means the highest efficiency is always maintained No humidity increase on supply air side Minimal water consumption; because only the exact amount of water, which then evaporates, is sprayed onto the surface. This means no sumps, no filtering, no recirculating water, no hygienic problems and therefore no intensive cleaning necessary POLYBLOC USA - Lancaster, PA - Phone 717-299-5679 - info@usa.com - www.usa.com

2014US - 4.3 Softcool Design and function Function The return air side of the exchanger surface is sprayed with a very small quantity of water. 10,000 CFM of outside ait at 90 F can be cooled to 77 F, without adding any moisture, by cooling the return air at 79 F to 62 F. The softcool system will use only 30 GPH to do this. Through an optional water saving device, this maximum water volume can also be matched to the current partial load situation. As there is no nozzle small enough to apply such a small amount of water to the entire heat exchanger surface so that it is fully wetted, a system of a few moveable flat-spray nozzles is used. There is no or only very little excess water. The water is evaporated on the return air side. The energy for evaporation comes through the heat exchanger wall from the outdoor air side. This is then cooled. No water comes into contact with the supply air. The Softcool system works with the existing mains pressure of 30-40 psi. This means that no recirculation tank or recirculation pump is required. The growth of harmful microorganisms is prevented and the operator has no unnecessary electricity or maintenance costs (circulation pumps often require more than 1 kw of electrical power). The time-selectable, fully automatic washing process stops the exchanger surface getting dirty. A specially developed biodegradable cleaning agent is used in a very low concentration. The efficiency of the heat exchanger is not impaired by a layer of dirt, even after an extended operating period. This eliminates the need for manual cleaning of the heat exchanger, which would otherwise be necessary from time to time. A single highly effective POLYBLOC cross-flow plate heat exchanger is used. Even without a second downstream heat exchanger connected in series, optimum heat recovery is achieved in winter during heat recovery. The pressure drop and consequently also the electricity required for the fans, as well as the space required, are low compared to systems with dual plate heat exchangers. POLYBLOC USA - Lancaster, PA - Phone 717-299-5679 - info@usa.com - www.usa.com

2014US - 4.4 Softcool Design and function Design The Softcool system comprises a POLYBLOC plate heat exchanger made of pure aluminum with a hydrophilic coating, which is also used for heat recovery in winter, and a moveable wetting and washing unit fitted on the return air intake side as a fully plumbed and wired compact unit. The aluminum bypass damper and fins with sealing lips are fitted on the outdoor air intake side. The bypass is a sheet steel cavity at the side of the heat exchanger. The entire structure is made up primarily of largely corrosionresistant materials, such as stainless steel, aluminum and plastic. Softcool is supplied as a fully pre-assembled module for ventilation units or also with an insulated diagonal casing to create an intermediate flange joint between ventilation unit parts or ducts. Normally, the control unit and the reservoir for the cleaning agent, with a fitted dosing pump, are supplied fully plumbed and wired separately rather than together. POLYBLOC USA - Lancaster, PA - Phone 717-299-5679 - info@usa.com - www.usa.com

2014US - 4.5 Softcool hx diagram POLYBLOC USA - Lancaster, PA - Phone 717-299-5679 - info@usa.com - www.usa.com

2014US - 4.6 Softcool Use of rainwater for the Softcool system The Softcool system can be operated easily with filtered rainwater as evaporation water. Due to the below-neutral ph of the rainwater, aluminum is, in principle, less at risk of corrosion if a number of recommendations are taken into consideration. POLYBLOC recommends: 1. Always use roof run-off water, but no copper guttering or downpipes! Never use rainwater from roads or public areas. 2. Filter rainwater and store it in plastic containers without letting light in to prevent algae growth. If storing large volumes of water for a long time, use an anti-algae agent in accordance with the recommendations of the rainwater system manufacturer. Caution: This chemical additive must not come into contact with aluminum. If the stored rainwater volume is not sufficient to maintain cooling operation, water that has been softened to 18 ppm CaCO3 must be supplied from an ion exchanger. This water treatment unit is operated by opening a solenoid valve subject to the level in the rainwater container. The float switch is set up so that treated water is supplied with a reserve volume of one day's consumption of rainwater. To minimize the volume of treated water supplied, the volume of treated water should be just one day's consumption. This means that the volume for no more than two days' consumption is stored. If it rains in the meantime, only a minimum of treated water has been used. Generally, cooling is only carried out in the daytime. This means that the water treatment unit can be very small, as topping off can be carried out throughout the night and part of the day. 3. The pump supplying the Softcool system with rainwater must overcome the height differential between the container and the nozzles, and must achieve a maximum nozzle pressure of 30 to 40 psi. If the pump is combined with an air vessel, this can be pressure controlled. 4. All pipes must be plastic or stainless steel, no copper pipes. This includes the rainwater guttering and collectors, as well as the supply lines to the water treatment unit. For more information about rainwater harvesting, visit: www.harvesth20.com POLYBLOC USA - Lancaster, PA - Phone 717-299-5679 - info@usa.com - www.usa.com

2014US - 4.7 Softcool Engineering information Engineering information 1. Water quality must be <1 gr/gal (no hardness increase) 2. Plastic or stainless steel water pipes, no copper pipes 3. Provide a water filter in the untreated water 4. Untreated water pressure at softener min. 40 psi, max. 90 psi 5. Return air guide diagonally from top to bottom through the plate heat exchanger 6. Position of the wetting unit must be at the top of the return air intake 7. Provide a mist eliminator on the exhaust air side 8. Accessibility through service doors to the wetting unit must be guaranteed for monitoring and maintenance work (incl. slip-resistant air separator) 9. Accessibility to the exhaust air side of the exchanger is highly recommended. No service opening is possible in the exchanger and Softcool area 10. Full length stainless steel drain pan 11. Capacity of the drain pan on the exhaust air side of at least one wash cycle (we recommend a minimum rim height of 3 inches) 12. Drain pan on the exhaust air side at least 1-1/2 inches 13. Size the drain pan trap according to the underpressure/overpressure 14. Ensure separate drains for softener (backwash/overflow). Drain into open drain 15. Wall conduit for the electrical cables and water pipes at the control panel (not prepared at the factory) Installation information 1. Softcool is generally supplied as a module for ventilation units. 2. The heat exchanger is watertight. The plate heat exchanger should therefore be carefully sealed with PU sealant (e.g. SIKAflex 521) to the casing, particularly at the return air/supply air joint (never use silicone due to inadequate adhesion). 3. Where there are connections, pay attention to the flow direction at the solenoid valve and pressure reducer (arrow on fitting). For full Guide Specifications complying with MasterFormat, CSI and CSC, visit our website at : www.usa.com/download.html POLYBLOC USA - Lancaster, PA - Phone 717-299-5679 - info@usa.com - www.usa.com