X16PDM P R O G RAMMABLE

Similar documents
X11CA COMPUTER ANNUNCIATORS

Plant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AIS750 Series Alarm Annunciator

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

4 & 8-POINT ANNUNCIATORS Instruction Manual

System 9000TS Sequence of Events Recorder

21-light Remote Annunciator. Owner s Manual

STATUS ALARM HISTORY ALARM RESET

DRAFT 20 October 2014

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

AN-3100D Annunciator

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

IF-L/RF Protection Switch

Model A1700 Series Annunciator

Series 725 Programmable Alarm Annunciator

ESP TECHNOLOGIES LIMITED

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Complex alarming made simple

AO Annunciator Module

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Model A2100 Series Annunciator

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

IntesisBox BACnet/IP Server - Notifier ID3000 series

System 9000TS Event Recorder

Across-the-Line SERIES MP300 Combined Manual and Automatic

ME 3011C / Alarm Indication / Quick Reference Guide

Annuciator Logic Controllers

Soft Start Series MP700 Solid State, Reduced Voltage

Conventional Releasing Control Panel

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

725B Configuration Software Manual

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Instruction Manual Model L2 RF Switch

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Instruction Manual Model Backup Switch, 1 for 8

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Model A1600 Series Annunciator

RS485 MODBUS Module 8AI

For Complete Fire and Gas Solutions

P2267 NETWORK INTERFACE

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Nov 08 PRODUCT SPECIFICATION SHEET

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

INTELLIGENT FIRE ALARM CONTROL PANEL

ACTIVE INFRARED BARRIER

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

System 9000TS Sequence of Events Recorder

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

MODEL B2 INSTALLATION MANUAL

RAYCHEM NGC-30 COMPONENTS

Industrial Grade Gas Detection Detecting The Difference

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Flair 500 Series Annunciators

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

VA301C CONTROLLER WITH BACnet OPTION

UNC100 Integra Manual

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

NETWORK FIRE ALARM CONTROL PANEL. Features

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

ACCURATE ELECTRONICS INC

Fire and Gas Monitoring Panel ST7-HV

LORAIN CIP 4890/48120 DC Power System

Sensor Interface Module Installation/Operation Instructions

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Variable Frequency Drive SERIES MP800 VFD

Modbus TCP/IP Option Instruction Manual

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

INTREPID Perimeter Intrusion Detection System

I/A Series 716C 1/16 DIN Temperature Controller

RELEASE DEVICE CONTROLS

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

4100U City and Relay Cards Installation Instructions

Panel Mounted Fault Annunciator Series

ESSEX ENGINEERING CORPORATION

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Specification/ Data Sheet

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

LORAIN CSP DC Power System

WM3000 WIRELESS MODULES

RTD TEMPERATURE SENSING SYSTEM

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Transcription:

S E R I E S XPDM P R O G RAMMABLE D I G I T A L M O N I T O R S E N G I N E E R I N G C O M P A N Y

The Ronan Series XPDM Programmable Digital Monitors are the latest generation of Ronan s state-of-the-art digital input man machine interface and remote annunciators offered in most common mechanical configurations. The systems in the XPDM Programmable Digital Monitors feature high density input field contact capacity with remote indicator light output. A system common trouble and a per-point auxiliary relay output may be utilized for field contact repeater or for remote group alarms. The system monitors internal routines and the communication backbone, signaled by dedicated LED or relay contact closure. XPDM is equipped with a host interface module that provides advanced communication interface protocols to interface with an external host computer, local network, or plant network. F E A T U R E S INPUT Dry Contact System Powered Vdc ly Open/ly Closed Live Contacts (Isolated) Vdc, Vdc, Vdc or Vac, 0 Vac SEQUEE All Standard ISA s User Configurable OUTPUTS Dual Configurable Auxiliary Contact Double Throw Selectable ly Energized or De-energized GP or HS Relays May be Added in the Field Common System Trouble Alarm Reflash System Trouble Alarm Serial Alarm Output Protocol Ronan Proprietary MODBUS RTU Slave TCP/IP DNP.0 Alarm Serial Interface Object Link Embedded for Control (OPC) DESIGN TECHLOGY Microprocessor Based High Noise Immunity Field Proven Off-the-shelf Worldwide Serial Input/Output Comprehensive User Configuration with Standard Windows Software MECHANICAL Relay Rack and Surface Mounting Light Weight Reinforced Terminal Block W ARRANTY Three () Years APPROVALS UL Underwriters Laboratories CE Cenelec CUL Canadian Underwriters Labortories

P P V+ V- G FUSE PWR PROGRAMMABLE DIGITAL MONITORS/Digital Input to Serial Output The Ronan XPDM Programmable Digital Monitor Systems are designed for the needs of the process and power industries where field inputs and electronics are required to be some distance away from the display or indicating lamp cabinets, such as Relay Rack Room from Control Room, using multiconductor lamp cabinet cables. The systems provide all the basic features of an annunciator in a small, high density module chassis. A system common trouble alarm and a per-point auxiliary relay output may be utilized for a field contact repeater or for remote group alarms. The per-point optional auxiliary relay module, equipped with one to four relays, provides a selectable form A or B type dry contact. A system common reflash output allows remote annunciation of any window going into alarm. Similar to the XCA Window Annunciator, the Programmable Digital Monitor provides serial output of alarms in many industry standard protocols to Host computers, Human Machine Interface (HMI) computers, PLCS and DCS. SURFACE-MOUNT REMOTE LOGIC CHASSIS The Ronan XPDM-SM Surface-mount Remote Logic Chassis are designed in two sizes of point and point logic inputs. The chassis is used to mount in NEMA enclosures with standard termination facility of Weidmueller or custom termination of various industry standard terminal blocks. The system is interfaced to HMI computers through its serial output using industry standard OPC interface via the Host interface module. The system can also interface to one of many types of Ronan lamp cabinets or mosaic cabinets through multiconductor lamp cables or individual wires. The system is widely used in applications where field contact status is to be displayed on graphic displays operating in a door mounted industrial computer, or a visual lamp cabinet mounted on the door of the enclosure. A Overall B Cutout.0" (. mm) XPDM." (. mm) JA 0 JB.00" (0.0 mm) Optional Elco Connector 0." (. mm) Dia. 0." (. mm) A Overall B Cutout Model Inches mm Inches mm XPDM-SM- ALM.0... XPDM-SM- ALM 0.. 0.0.

FUSE PWR XPDM PROGRAMMABLE DIGITAL MONITORS/Digital Input to Serial Output RACK-MOUNT REMOTE LOGIC The Ronan XPDM-RR Rack-mount Remote Logic Chassis are designed for standard.00 inch (.0 mm) or.00 inch (0.0 mm) relay rack mounting. Field inputs and remote lamp outputs are accessed from the rear of the chassis via a multipin Elco connector or standard terminal block. The system is used for high density alarm input monitoring in power plants with remote lamp cabinet connection. The system provides a serial output, daisy-chainable to a host device, using industry standard communication protocols. 0." (. mm) Dia. Optional Elco Connector." (. mm)." (. mm).".0 mm).00" (.0 mm)." (. mm)." (0. mm) Filter Module MODEL XPDM-SM WIRING To Another XPDM-J FUSE PWR P P V+ V- G 0 0 0 0 JA 0 0 0 0 XPDM 0 0 0 0 0 0 JB 0 Live Dry + 0 0 Test Silence Ack Reset First Out Reset GP GP To Host RS RS (+) Vdc ( ) Power Supply or DC to DC Converter V+ XCA-IM A TEST A SIL TO CTA ACK RFL RST RAN FRST GP A COM GP TX+ TX- A COM P GND RS RX+ RX- CTA COM RFL COM PRGM RUN P RS RUN COM GND V- V+ P P P RXD TXD RXD TXD ERROR RUN XCA-IM * ** AC Horn Horn Horn Electronic Horn To Power as Required.0" (. mm) H(+) N( ) G Vac or Vdc Communication Cable

XPDM XPDM REMOTE ANNUIATOR SYSTEMS Multiconductor Cable or FC Wire Field Terminal Assembly XPDM-SM XCA-IM Human Machine Interface Multiconductor Cable or Multiconductor Cable or Wire Wire FC Field Terminal Assembly XPDM-RR XCA-IM Serial Alarm Output Lamp Box FC XPDM-SM Serial Alarm Output Multiconductor Cable or Wire XCA-IM Inlay or Mosaic Graphic MODEL XPDM-RR WIRING 0 0 0 0 0 JA 0 0 0 Notes for XPDM-SM/XPDM-RR: (H) Field Contact Voltage for Dry Contact or Live Input (FC) Field Contact Return (ME) Connect All First Out Windows in a Group (AL) Open Collector Transmitter Output for Lamp JA, JB: Mimic Lamp Outputs Notes for XCA-IM: TO: A, A, CTA, RFL RUN for Transistor Driver* A, A, CTA, RFL, RUN for Auxiliary Output** 0 0 0 0 0 0 0 JB Live Dry + 0 : ly Opened To Another COM: Common XPDM-J : ly Closed A: Horn A: Horn CTA: Common Trouble Alarm RFL: Reflash RUN: XCA-IM Power Indication GP, GP: Programmable Inhibit Function 0 J J V+ V G Communication Cable (H)A (FC)A (H)B (FC)B (H)C (FC)C (H)D (FC)D (ME)A 0 (ME)B (ME)C (ME)D (AL)A (AL)B (AL)C (AL)D Test Silence Ack Reset First Out Reset GP GP To Host RS RS Wiring Detail GND V- V+ V+ TEST SIL ACK RST FRST GP GP TX+ TX- GND RX+ RX- PRGM P RS P P RS P XCA-IM RUN P RXD TXD RXD TXD ERROR RUN XCA-IM H(+) N( ) G A A TO CTA RFL RAN A COM A COM CTA COM RFL COM RUN COM (+) Vdc ( ) Power Supply or DC to DC Converter Vac or Vdc * ** AC Horn Horn Horn Electronic Horn To Power as Required

SEQUEE DIAGRAMS Return to Off First to Reset while Off To Acknowledge while Subsequent to or Subsequent Alarm or Acknowledged Acknowledge or Alarm Fast Flashing On Flashing First Out Reset while Subsequent Acknowledged On Acknowledge while First Out Reset or First Acknowledged Flashing Acknowledge or First Alarm Intermittent Flashing SEQUEE M Manual Reset Acknowledge, Reset and Test Push Buttons Alarm Device Lock-in Momentary Alarms Until Acknowledged The Device is Silenced and Flashing Stops when Acknowledged Manual Reset of Acknowledged Alarm Indications after Conditions Return to Operational Test SEQUEE FA Automatic Reset First Out Reset with First Out Flashing and Reset Push Button Acknowledge First Out Reset and Test Push Buttons Alarm Device Lock-in of Momentary Alarms until Acknowledged First Out Flashing Different from Subsequent Flashing First Out Reset Push Button to Change the First Out Indication to be the Same as Subsequent Indications Automatic Reset of Acknowledged Alarm Indications when Conditions Return to Operational Test Alarm Ringback Reset RingBack Slow Flashing Alarm Ringback Off Acknowledge while Return to To Alarm Ringback or Alarm Fast Flashing Basic Option Key Words Number Letter Key Words A Automatic Reset Silence Push Button M Manual Reset Silence Interlock R Ringback First Out Reset Interlock No Lock-in No Flashing No Automatic Alarm Silence Common Ringback Automatic Ringback Silence First Out Option Key Words Designation Number Key Words F No Subsequent Alarm State 0 No Ringback F No Subsequent Common Ringback Alarm Flashing F First Out Flashing and Automatic Momentary Reset Push Button Ringback Dim Lamp Monitor Lamp Test Return to Alarm Ringback Acknowledge On Acknowledge while SEQUEE R Ringback Acknowledge, Reset and Test Push Buttons Alarm and Ringback Devices Lock-in of Momentary Alarms until Acknowledged The Device is Silenced and Fast Flashing Stops when Acknowledged Ringback and Indications when Conditions Return to Manual Reset of Ringback Indications Operational Test

XPDM MODULES HOST INTERFACE MODULE The Model XCA-IM Interface Module connects the XPDM Programmable Digital Monitor Remote Logic Annunciator with external host devices. Hosts can be a DCS, PLC, or plant computer. An isolated RS or a 0 Base T network connection is used with the most common industry accepted communication standards such as MODBUS, DF, and TCP/IP protocols for host communication.." (. mm)." (.0 mm).00" (.0 mm).00" (.0 mm) V+ XCA-IM A TEST A SIL TO CTA ACK RFL RST RAN FRST GP A COM GP TX+ TX- A COM P GND RS RX+ RX- CTA COM RFL COM PRGM RUN P RS RUN COM GND V- V+ P P P RXD TXD RXD TXD ERROR RUN." (. mm) 0." (.0 mm) Dia. The Module provides a number of special features such as timestamped event archive, common trouble alarm, dual horn output, reflash output, and system diagnostic output. All outputs are provided in the form of an open collector transistor and selectable Form C dry contact. Additional on-board LEDs are designed to indicate serial communication and system status. ALARM SEQUEE/DISPLAY MODULE The Ronan Model XPDM is designed with all sequences available internal to each module, allowing for field programmable selections of all commonly used ISA sequences through a computer or laptop using simple graphical user interface entry. Selection of field contact polarity is allowed through the on board jumpers for each channel. Each alarm/display combination module contains a single, dual, triple, or quad alarm channel with its associated dual lamp or LED displays. The modules are removable from the front without interfering with the remaining modules. AUXILIARY CONTACT MODULE The Auxiliary Contact Module is available for the XPDM Annunciator with single, dual, triple, or quad relay circuit, according to the density selection. The modules plug in from the front of the system. Each relay provides for a form A or B type contact, normally open or normally closed, and normally energized or normally not energized, and is selectable by a jumper switch.

CONFIGURATION XPDM-CONFIGNT The Ronan XPDM Programmable Digital Monitors are configured fully with the use of a Windows graphical user interface application operating in a Windows environment on a PC or Laptop through an RS serial connection to the XCA-IM interface module. The application allows for factory or field programmability of all features for each window. Configuration data is saved in non-volatile memory on-board each module. Selections such as alarm sequence, first out grouping, operational or lamp test, output signals follow alarm or field contact, time delay and special functions are all set through the configuration application software.

HMI/MMI (Human and Man Machine Interface) GRAPHIC MONITORING APPLICATION SOFTWARE Ronan XPDM easily interfaces with all common industry display software such as Wonderware, RS View, Intellusions, etc. Ronan provides the XPDM System with HMI/MMI software and hardware for all monitoring requirements of state-of-the-art installations. Ronan provides OPC configuration software of graphics and object tagging, all based on process or plant requirement. The system easily adapts to a graphics CRT based annunciator for special annunciator applications. Computer Hardware Options: Standard PCs Hardened Industrial PCs Dust and Moisture Proof Touch Screen Systems Wonderware is a trademark of Invensys Systems, Inc. RS View is a trademark of Rockville Automation Intellusions is a trademark of Emerson Typical Graphical User Interfaces

FUSE PWR COMMUNICATION / PROTOCOLS The Ronan XPDM Programmable Digital Monitors have comprehensive serial alarm communication facilities to interface to Host machines and transfer field input status to, or receive alarm data from PLCs, DCSs, Network Alarm Servers and Computers. MODBUS RTU SLAVE The MODBUS RTU Slave protocol allows users of PLCs and DCSs that are operating as MODBUS Masters to periodically acquire the status of annunciator inputs or transmit alarms to the annunciator for process monitoring. Status of the annunciator is continuously updated in a pre-defined Memory Register Map complying to the MODBUS protocol. The Host (MODBUS Master) periodically reads or writes to the Memory Register Map serially using pre-defined MODBUS command sets. The data is then used for process monitoring. Events XPDM XCA-IM DCS, PLC or Computer ALLEN BRADLEY DF INTERFACE The Allen Bradley DF protocol allows users of AB PLCs to periodically acquire or transmit alarm data to or from the annunciator for monitoring and control. The input status is periodically transmitted as a bitmap complying to the DF protocol. The PLC provides an open serial port to send or receive the bitmap status. 0

FUSE PWR FUSE PWR NETWORK TCP/IP Transport Control Protocol/Internet Protocol (TCP/IP) The Ronan XPDM provides as an optional connection using the XCA-IM interface module and XCA-NM network converter module to a local or plant network. The input alarm status is transmitted or received via TCP/IP at speeds of up to 0 MB all across the network. Typical TCP/IP Address..0. 0 Base T Ethernet 0 Base T XPDM XCA-IM XCA-NM Network Hub Other Network Device Plant Network RONAN PROPRIETARY (Alarm/) The XPDM provides features to serially transmit input alarm status to external host devices through XCA-IM. This feature can be used to transfer input alarm status serially to Ronan s X0 Serial Annunciator for remote visual annunciation display. Lamp Box Lamp Box XPDM XCA-IM X0-A X0-B Events RS/RS

FUSE PWR FUSE PWR COMMUNICATION / PROTOCOLS OPC INTERFACE (Object Link Embedded for Control) OPC is designed to allow client applications access to alarm input status of a system in a consistent manner. With wide industry acceptance, OPC provides easy integration into the common Human Machine Interface (HMI) applications widely used in the process industry. OPC Client OPC Client Local OPC Server Ronan OPC Interface Driver Ethernet Network OPC Server XCA-NM Ronan OPC Driver OPC Interface Typical TCP/IP Address..0. XCA-IM XPDM TYPICAL APPLICATION The XPDMs feature an optional bit Windows NT driver and mechanisms for OPC clients to be notified of the occurrences of specified events and alarm conditions. They also provide services which allow OPC clients to determine the events and conditions supported by an OPC server, and to obtain their current status. Graphics OPC Client Typical TCP/IP Address..0. Computer with HMI Interface OPC Server XCA-NM XCA-IM XPDM Plant Ethernet Network

SPECIFICATIONS/POWER REQUIREMENTS System Voltage: Lamps, Logic Vdc ± 0% Field Contacts Vdc, Vdc, Vdc, Vac, or 0 Vac Power Source (System External): Power Supply Vac 0/0 Hz; 0 Vac 0/0 Hz Converter Vdc, Vdc, or Vdc Temperature Range: Operating 0 to 0 C ( to 0 F) Storage -0 to + C (-0 to + F) Inputs: Contact Dry or Live; ly Open / ly Closed Field Selectable Interrogation Voltage Vdc, Vdc, Vdc, Vac, or 0 Vac Response Time: 0 Milliseconds EMI/RFI Capability: CE Compliant Outputs: Fast Flash, Slow Flash, Steady ON, Intermittent Fast Flash Dual, Selectable by Cabinet Module Auxiliary Relays Form C, Selectable Form A or B; ly Not Energized or ly Energized Contact Rating General Purpose: Amps @ Vdc; 0. Amp @ Vac Common System Trouble: Form C, Amps @ Vdc; 0. Amp @ Vac Open Collector Transistor Output 00 ma @ Vdc Common System Reflash: Form C, Amps @ Vdc; 0. Amp @ Vac Open Collector Transistor Output 00 ma @ Vdc Controls: Momentary Push Button: Integral or Remote; Single Pole ly Open; +V Switched; Silence; Acknowledge; Reset, Test, GP, GP Diagnostic: System Trouble Alarm (RUN) - Form C, Amps @ Vdc; 0. Amp @ Vac System Trouble Alarm (RUN) - Indicating LED Green Communication Diagnostic (ERROR) - Indicating LED Red Transmit/Receiver LED Pair Communications: Serial - RS (P) to External Host Network - RJ (TCP/IP) to External Host Serial Protocols: MODBUS RTU, Allen Bradley, DF, DNP.0, Ronan Proprietary Network Protocols: TCP/IP (OPC) Serial: RS (P) - System and Option Programming via Laptop or Computer Software - Ronan XCA Configuration Special Feature: Alarm Time Stamping Alarm Storage - 00 Alarms GP, GP - Special Function Push-button Interface To specify the correct power supply, count the number of alarm modules you need to power from the supply. Calculate the total requirement as follows: Total Watts = No. of Modules x F(Factor + F Aux.) + P(IM) Model F Module F Aux. Relay Adder P(IM) XPDM W W 0W Match the total wattage with the next higher power rating of the Power Supply or Converter listed. DC/DC Converters Model - Power Failure, Circuit Breaker, Power ON Light, Diode Gated - / - 0 SCP - / - 00 SCP - / - 00 SCP - / - 0 SCP - / - 00 SCP - / - 00 SCP Power Output Watts DC Voltage Out DC Voltage In AC Voltage In DC Voltage Out Power Output Watts Diode Grated Output AC/DC Power Supplies - - - - 0 - - - - 00 - - 0 0 - - 0 - - 0 0 - - 0 - - 00 0 - - 0 - / - - / - 0 - / - - / - 00 - / - 0 - - 0DA - - DA - - 00DA - - 0DA

ORDERING INFORMATION XPDM PROGRAMMABLE DIGITAL MONITORS Logic Chassis (Rack-mount/Surface-mount) XPDM-RR--T XPDM-RR--TE XPDM-SM--T XPDM-SM--TE XPDM-SM--T XPDM-SM--TE Module ( Points Maximum without Auxiliary Contacts/ Points with Auxiliary Contacts), Terminals Only Module ( Points Maximum without Auxiliary/ Points with Auxiliary Contacts), Elco Connector for Lamp Driver Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Terminals Only Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Elco Connector for Lamp Driver Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Terminals Only Module ( Points without Auxiliary Contacts/ Points with Auxiliary Contacts), Elco Connector for Lamp Driver Notes:. Each XIPDM Chassis will require an XCA-IM Interface Module.. For Auxiliary Module selection, refer to XCA Literature. Use Quadalarm Aux. only.. XIPDM-RR Rack-mount Chassis available in modules only.. For Lamp Cabinet selection refer to Ronan Lamp Cabinet Literature.. For every Auxiliary Module an associated Alarm Module is required.. For Communication Cables refer to table below. Alarm Modules XPDM - ( ) - ( ) - ( ) - ( ) A. Type: (Other sequences available) M = ISA M- F = ISA FA- ASL = ISA A-,, B. Field Contact Voltage: 0 = Vdc, Not Opto-isolated = Vdc, Not Opto-isolated = Vdc, Not Opto-isolated = Vac or Vdc, Opto-isolated = 0 Vac or 0 Vdc, Opto-isolated = 0 Vdc, Not Opto-isolated = Vac or Vdc, Opto-isolated = Vdc, Open Collector = Vac or Vdc, Opto-isolated C. Special Options and CTA** : 00 = Operational Test, NNE CTA follows FC 0 = Operational Test, NNE CTA follows Alarm 0 = Lamp Test, CTA, Lamp Inhibit Input on F, Dual Horn Selectable 0 = Lamp Test, NNE CTA follows FC = Lamp Test, NNE CTA follows FC, Lamp Inhibit on F, Dual Horn Selectable = Operational Test, NNE CTA follows FC, Lamp Inhibit Input on F, Dual Horn Selectable = Option 0 and Four Point Lamp Holder on Non-000 System = Lamp and Operational Test PB, NNE CTA follows FC, First Out Reset and Reset PB A B C D = Operational Test, NNE CTA follows FC, Dual Horn Selectable = Operational Test, NNE CTA follows FC = Operational Test, NNE CTA follows FC, FC Time Delay 0 = Lamp Test, NNE CTA follows FC, FC Time Delay = Operational Test, NNE CTA follows FC, FC Time Delay, Lamp Inhibit Input on F, Dual Horn Selectable = Lamp Test, NNE CTA follows FC, FC Time Delay, Lamp Inhibit on F, Dual Horn Selectable = Operational Test, NNE CTA follows FC, Lamp Mimic Output on TOA-TOD D. Auxiliary Relay Behavior: = NE Aux follows FC = NNE Aux follows FC = NE Aux follows Alarm = NNE Aux follows Alarm = NE Aux follows Acknowledge = NNE Aux follows Acknowledge = NE Dual Aux follows FC = NNE Dual Aux follows FC Auxiliary Contact Modules Notes: Modules contain relays only. Universal Chassis allow addition of Auxiliary Contact Modules in the field. Surface-mount Chassis provide amp @ Vdc. XCA - ( ) - AUX - ( ) = Monalarm = Dualarm = Trialarm = Quadalarm Relay Type: GP = General Purpose Relay, Amp @ Vdc, 0.0 Amp @ Vac HS = Hermetically Sealed Relay, Amp @ Vdc, 0.0 Amp @ Vac

INTERFACE MODULES / COMMUNICATION Interface Modules XCA-IM - ( ) - ( ) - ( ) B A. Voltage C 0 = Vdc B. Communication Protocol =Serial MODBUS RTU Slave =Serial Allen Bradley (DFI Protocol) = Serial Ronan Proprietary (X0) =Network TCP/IP (Requires XCA-NM, XCA-SC- and XCA-SC-) =Network TCP/IP (OLE for Control OPC) (Requires XCA-NM, XCA-SC- and XCA-SC-) = Consult Factory for Special Protocols A C. Physical Communication Layer to Host =RS =RS = Network 0. (RJ) XCA-NM: RS to TCP/IP Network Converter Module COMMUNICATION CABLES XPDM-LC - - ( ) - ( ) XPDM Logic to Lamp Cabinet, Conductor, with Elco Connectors at Each End, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Logic to Lamp Cabinet with Elco Connector on X Side, Stripped Ends on Lamp Cabinet, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Logic to Field Termination with Elco Connectors at Each End, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Logic to Field Termination with Elco Connector at Logic, Stripped Conductor at Terminals, 0.00 Feet (.0 Meters) XPDM-LC - - ( ) - ( ) XPDM Programmable Digital Monitor to XCA-IM XPDM-LC - - ( ) - ( ) XCA-IM to Host RS,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) XCA-IM to Host RS,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) XCA-IM to XCA-NM,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) XCA-NM to Host (Category ),.00 Feet (. Meters) XPDM-LC - 0 - ( ) - ( ) XlPDM Programmable Digital Monitor to XPDM,.00 Feet (. Meters) XPDM-LC - - ( ) - ( ) Cable Assembly, XCA-IM to Computer/Laptop,.00 Feet (. Meters) Standard Length (For Programming and Configuration) Length (Feet) Cable Type: 0 = PVC = XPLE

W A R R A N T Y Ronan warrants equipment of its own manufacture to be free from defects in material and workmanship, under normal conditions of use and service, and will repair or replace any component found to be defective, on its return, transportation charges prepaid, within one () year of its original purchase. This warranty carries no liability, either expressed or implied, beyond our obligations to replace the unit which carries the warranty. RONAN ENGINEERING COMPANY D isplay Products Division 00 Oxnard Street, Woodland Hills, CA U.S.A. 00-- Fax -- Tilley Road, Crowther Industrial Estate, Washington, Tyne & Wear, U.K., NE OAE -- Fax -- Bermondsey Road, Toronto, Ontario, Canada MB Z --00 Fax --0 http://www.ronan.com E-Mail: sales@ r onan.com XPDM Rev. 0 0/0 Printed in U.S.A.