INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

Similar documents
O p e r a t i n g I n s t r u c t i o n s

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

THE TINY LIGHTWEIGHT

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

PAC1500Xi PORTABLE APPLIANCE CHECKER

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

Autofill Wall Mount Boilers

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Rota- Spray Instructions (Mega Part & )

n/a ROTARY JET ETCH/DEVELOPER TANK (RE)

Food Steamer. Instruction manual. Model: CL205-A

IMPORTANT SAFETY INSTRUCTIONS

ADVANCE ELECTRIC THERMAL STORE

ROTA-SPRAY PROCESSOR MODEL 1210 (ROTARY-JET) INSTRUCTIONS MEGA PART NO: &

Traditional Kettle CTK17U CPT445U

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INSTRUCTIONS MODEL: BT1 MOBILE BANQUETING TROLLEY

Installation Instructions / Operating & Maintenance Manual Ablution Plant Model BTHW-1

Cooled Incubators Series 1, 3 & 4. Instruction Manual

USER INSTRUCTION MANUAL. Autofill Water Boiler

Imperial Electric Fires

Rota- Station and Plus Instructions

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

Panel Plating Instruction Manual

DEVIL CERAMIC SPACE HEATERS

Rota- Station and Plus Instructions (Mega Part & )

20L Electronic Dehumidifier

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

7Litre Evaporative Cooler With Remote

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Heating Indicator Thermostat Control Inner Pan Heating Element Food Basket Removable handle

Model: GF256-A. Waffle Maker. Instruction manual

Powerdri. UK Manual Accessories Warranty Registration. Professional Dehumidifier

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Unvented Electric Water Heater 10/15 litre Undersink

Inspect bath carefully and report any damage or faults before installation. No claims can be entered in to after installation.

Installation, Operating and Servicing Instructions

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

General Care and Safety Guide

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OPERATING INSTRUCTIONS

Turbo Lite Corded Handheld Stick Vacuum

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Mobile Air Conditioner Instruction Manual Model TC-N9KM

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

Operating Instructions

Water Boiler. Instruction manual. Model: GL346-A/GL347-A/GL348-A/GL349-A

Stainless Steel Counter Refrigerators Instruction manual

ADVANCE ECB ELECTRIC COMBINATION BOILER

Compact Cyclonic Bagless Upright Vacuum Cleaner

Pasto Sous vide water bath

General Care and Safety Guide

The Professional s Choice

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

General Care and Safety Guide

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Soup Kettle. Instruction manual. Model: L714-A/L715-A/CP851-A CP851-A L715-A L714-A

2.9kW Portable Air Conditioner

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

Thermo-Sealer. Manual Heat Sealer. User Manual

Platinum Series Electronic Panel Heaters

INSTRUCTIONS MANUAL. 1.8L Electric Kettle with Multi-Temp Feature SK-1800R (Red) SK-1800SS (Stainless Steel)

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Gallery Electric Fireplaces

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

User Instruction Manual

2.8KW ELECTRIC FAN HEATER

Spiral Dough Mixer. Instruction manual. Model: CP821

Bistro Contact Grill Instruction manual

CC770 / CC771 Envasadora al vacio. Instruction Manual QUICK NOTES

PANINI / SANDWICH GRILL

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

Alpha FlowSmart 25 and 50

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

General Care and Safety Guide

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

SEALED THERMAL STORE

DCO3 Operating Manual DYSON CUSTOMER HELPLINE am to 8pm, 7 DAYS A WEEK

Compact Cyclonic Bagless Cylinder Vacuum Cleaner

Transcription:

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

WARNING Asbestos exposure can cause severe and fatal diseases. Approved Code of Practices should be applied at all times when using this equipment to ensure safe working conditions. Manufactured by: Air Management Systems Ltd Unit 1 9 Cannon Lane Tonbridge Kent TN9 1PP Tel: +44 (0) 1732 368359 Fax: +44 (0) 1732 368361 Web: www.ams-holdings.com About this Manual: The purpose of this manual is to enclose all relevant information and data to this particular product and related uses. This manual is to be utilised by the user of this product to ensure correct and safe methods are used during related operations. All Rights Reserved Contents of this manual are not be copied or distributed by anyone without permission of the manufacturing company of this product. INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 2 of 15

Table of Contents 1. Description & Data... 5 1.1 General Description... 5 1.2 Technical Data... 7 2. Installation... 8 2.1 Power Requirements... 8 2.2 Positioning & Connection of Unit... 8 3. Operation... 8 3.1 Preparatory... 8 3.2 Start up... 9 3.3 Normal Running Checks... 9 3.4 Shut Down... 9 4. Safety Procedures... 10 4.1 General... 10 4.2 Transportation... 10 4.3 Handling... 10 4.4 Storing... 10 5. Maintenance... 11 5.1 Preventative Maintenance... 11 5.2 Replacing Filters... 11 5.3 Fault Finding... 11 6. Return Procedures... 12 6.1 Normal Return for Service... 12 6.2 Return after Hazardous Contamination... 12 7. Spare & Accessories... 12 7.1 Recommended Spares and Service Components... 12 7.2 Optional Extras... 12 INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 3 of 15

8. Technical System Information... 13 8.1 Pumps... 13 8.2 Fuses... 13 8.3 Wiring Diagram... 10 8.4 Tank Components... 15 INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 4 of 15

1. Description & Data 1.1 General Description The fundamental design emphasis of the AMS range of Water Management Systems, specifically the 110 volt and 230 volt units is to provide robust, yet lightweight modules which produces high water flow rates from a compact unit. In particular, the AMS 230 volt Water Management System produces 4.5 Gallons per Minute nominal flow rate, both to and from the shower head of a Decontamination Facility, with 25 and 5 micron filtration. The unit is compact and mobile and can be easily handled by one person. Castors fitted allows unit to be pushed and will pass through standard doorways. The water management system case is constructed from durable polypropylene, reinforced with welded internal ribs, where necessary. The Unit contains the following main components: - 140 litre Tank - Industrial Immersion Heating Element - Variable Temperature Thermostat - Large, Easy Access Tank Lid - Two Filter Pods (double filtration level) - Shower Supply Pump - Waste Water Pump - Power Cord with Plug - Castors Clean Water Input (Mains Feed) Thermostatic Temperature Control (with temperature status light indicators) Waste Water Input Waste Water Drainage Two Filter Pods Hot Water to Shower Figure 1.1 Unit Controls & Components Tank Drain Valve INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 5 of 15

Tank Twist-&-Lift Lid Push Handle Fuse Box Handles for Transport Power Supply Cord Waste Water Filter Link Castors Figure 1.2 Handling Components Figure 1.3 Unit Front & Back 6

1.2 Technical Data AMS 230V Water Management Main Electrical Supply Supply Voltage Current Protection Water Heater Element (electric): Supply Voltage Current Output Controls Protection 230v @ 50Hz 15A 15 amp in-line fuse 230v @ 50Hz 13A 3000W Thermostatic Control Secondary Thermostat (pre-set) within heating element body Shower Supply Pump: Supply Voltage 230v @ 50Hz Current 0.9A Output 360W Protection 7 amp in-line fuse Waste Water Supply Pump: Supply Voltage 230v @ 50Hz Current 0.9A Output 360W Protection 7 amp in-line fuse Dimensions: Height Width Length Weight Tank Volume 700 mm 600 mm 700 mm 200 kg when full (approx) 140 litres 7

2. Installation 2.1 Power Requirements The 230V Waste Management Systems are supplied with a 5 metre fixed lead fitted with a 230V 16 amp plug and must be connected to a power supply capable of sourcing 16 amps continuous. 2.2 Positioning & Connection of Unit The Water Management System should be mounted as closely to the Decontamination facility as possible and be connected as follow: (Refer to figure 1.1 & 1.2 to see connection illustrations) - Waste pipe from the shower tray connected to waste water input point - Ensure Waste Water filter link are connected (present) as per illustration - Hot water supply hose connected to shower unit. - Mains water supply hose connected to the mains inlet on system unit. - Waste discharge connected to appropriate drainage point. - The power supply cord should be run in a manner that does not create a tripping hazard. - Considerations should be made to which location the unit will be installed. - The unit should be positioned on a sturdy base to avoid unwanted movement and brakes on castors should be enabled. 3. Operation 3.1 Preparatory THE WATER MANAGEMENT SYSTEM SHOULD BE OPERATED UNDER THE SUPERVISION OF COMPETENT AND TRAINED PERSONNEL. - Ensure that the unit is correctly installed according to Section 2. The system will be delivered with the requisite hoses to be installed, complete with cam lock type hose connections where applicable. - Ensure that the Temperature control dial is turned to 0, prior to connection to the power supply. - Ensure that the Power Supply to the unit has an RCD protection facility fitted. 8

3.2 Start up - After connecting the necessary hoses turn the Water Management System on at the isolator, ensuring that the RCD protection is enabled. - Ensure that the shower valve within the decontamination facility is turned off. - Turn the Temperature control dial to the required setting Note that there is an inbuilt high limit setting on this heater to limit the temperature to a maximum of approximately 45 deg C. - Allow the temperature of the water in the tank to reach the required temperature, when this has been achieved the Red light will be Extinguished, leaving the Green light illuminated. - The pumps operate automatically; therefore to start the shower delivery pump you will need to turn the shower valve on. This will operate the inbuilt pressure switch within the shower supply pump, which will in turn start this pump. - By starting the shower pump the waste water pump is then energised. This pump shall continue to run while the shower pump is active. When the shower valve is closed the pressure switch will deactivate the shower pump. - The over-run facility of the waste pump is achieved by means of a run-on timer located within the unit. This is set to allow the waste pump to run for a set period after the shower pump has stopped. - Always use clean uncontaminated potable water, even if filling the tank using buckets, where mains water supplies may be unavailable. 3.3 Normal Running Checks - Periodically check the Water Management System and ensure that any RCD protection is operational - Periodically run the complete system to ensure that the water temperature rises and that both pumps operate satisfactorily. 3.4 Shut Down Switch off the Water Management System at the main isolator and turn the temperature control dial to zero 0. Never leave water in the storage tank, always completely drain the tank between uses to ensure that the risk of Legionella Bacteria build up is reduced. 9

4. Safety Procedures 4.1 General - Power cables should be routed so that they do not create a tripping hazard. - Whilst not in use the WMS must be emptied. - Keep lid closed to prevent tank contamination. 4.2 Transportation - Whilst in transit, it is imperative that the unit is secured to minimise movement. This can be partially achieved by locking the braked castors, but further securing will be required. - Care is to be taken to ensure safe handling whilst inserting and removing the unit from the vehicle. 4.3 Handling NB! The WMS must not be handled whilst in operation. - The WMS must be handled with care and attention. Although of robust build, any significant trauma could cause failure in operation. - Care and attention must also be taken to ensure that the person(s) handling or operating the unit are doing so in a competent way as not to cause injury to themselves. 4.4 Storing The unit must be stored in a place, avoiding: - Dampness, Extreme Temperatures, Hazard to Personnel etc. - This list is not exhaustive and common sense must prevail. 10

5. Maintenance 5.1 Preventative Maintenance - Keep the unit clean and dry. - Periodically check the condition of the power lead(s) and keep in good condition. 5.2 Replacing Filters - Isolate the power to the unit and disconnect all hoses - Carefully undo and remove the filter carrier, from the assembly. - Remove the Water filters from the aperture and seal it in an approved asbestos waste bag. - Be very careful in this operation not to damage or lose the O rings of the filter assemblies. - All type of filter changing is required to be done under controlled conditions. 5.3 Fault Finding Problem Unit doesn t run Pumps do not run Fault/Action Check power supply, if OK, possible faulty pump or electrical problem. Check Power Supply, else return unit for repair Check Fuses & Power Supply Leak on Filter Pod Water does not heat up Excess water in shower tray after use Check O-Ring on Filter Assembly Check that the temperature control dial is set correctly. If so check that the Reset switch on the Heater element has not tripped, if it has reset this by depressing. Check that fuses have not blown, replace where necessary The run on timer for the waste water pump needs to be set for a longer period so that it runs long enough to drain the tray 11

6. Return Procedures THE UNIT SHOULD BE EXAMINED, SERVICED & TESTED ONCE EVERY SIX MONTHS IN ACCORDANCE WITH CURRENT LEGISLATION AND MANUFACTURERS INSTRUCTIONS BY AN APPROVED SERVICE CENTRE. 6.1 Normal Return for Service - Remove the Water filters and dispose of it as required by law. - Clean the Filter Unit carefully with an approved vacuum cleaner. - Replace the Water filters with clean ones. 6.2 Return after Hazardous Contamination - As detailed above (6.1), but ensure that the unit is wrapped in polythene and sealed. 7. Spare & Accessories 7.1 Recommended Spares and Service Components - Filter Assemblies o 10 250mm Disposable Water Filters, rated at 5 micron and 25 micron - Spanner for removal of filters o Type SW2 - Fuses o 1 ¼ (32mm) Slow Blow fuses 7.2 Optional Extras The basic AMS Water Management System comes with the following hoses: - 15mm Mains Water connection with Cam lock fitted to one end - 22mm Shower Supply hose with Cam locks fitted - 22mm Shower Waste hose with Cam locks fitted - 22mm Unit waste discharge hose with Cam lock fitted to one end. 12

8. Technical System Information 8.1 Pumps Shower Supply Pump In-Line Strainer (Shower supply & waste line) Waste Water Pump Immersion Heating Element Figure 8.1 Pumps & Heating Element 8.2 Fuses In-Line Fuses Figure 8.2 Fuse Box 13

8.3 Wiring Diagram Figure 8.3 240V Wiring Diagram 14 of 15

8.4 Tank Components Heating Element Ball Valve Temperature Probe Heating Element INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 15 of 15