SAHARA2A-HP SERIES DryLine DEHYDRATOR USER MANUAL

Similar documents
SAHARA SERIES DryLine DEHYDRATOR USER MANUAL

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

HR150 SERIES DEHYDRATOR USER MANUAL

MODEL MW200 MODEL MW600 AIR DRYER

MDH Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide

ID SERIES CABLE DRYER USER MANUAL. Bulletin AE01B-A Date: 6 FEB 07

P4200PM / P5000PM Remote Air Dryer User s Guide

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

P6500W Air Dryer User s Guide

P4200W2 Series Air Dryer

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

PORTABLE DEW POINT MONITOR

347002K/177002K/34900

P550W Series Air Dryers

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Quick Alert Remote (QA216R)

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Dual Column Dehydrating Breather Manual

Carbon Monoxide Transmitter

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Waveguide Dehydrators

Model 1820 Dehumidifier

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Manual for MC37/MFC3600

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Rev B, 9/2/2009. Kodiak Chiller Overview

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Mark 25 Ultrapure Water Conductivity Analyzer

Manual for MC91 SETUP INSTRUCTIONS

P08033W Air Dryer Cycling Module User s Guide

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

Installation and Use Manual

Laptop / PC Programming Manual

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Manual for MC21A SETUP INSTRUCTIONS

Installation and Use Manual

Panel Mounted Heat Exchangers by Dantherm, Inc.

1.2.3 Returning Instrument for Repair.

Manual update 2016 MC37/MFC3600

rvm4c Installation Guide Remote Video Module

# TFB-S-120, TFB-L-120 TFB-S-220, TFB-L-220 FWS-S-120, FWS-L-120 FWS-S-220, FWS-L-220

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Original Instructions Instucciones originales Consignes originales. Model: AC R-1234yf A/C Recover, Recycle, Recharge Machine

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

SERVICE BULLETIN A

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

AS950 REFRIGERATED SAMPLERS

Table of Contents SECTION PAGE

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

INSTALLATION and USE MANUAL Models (L)VRC8WS, (L)VRC8WSJO Factory Prep ezh2o Bottle Filling Station and Cooler

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

MT300 Series Dehydrators

Flopurge TS. Operation Manual

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

STEAMPRO. Steam Generator Troubleshooting and Service Guide

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Intelligent Electronic Enclosure Thermal Management Systems

Blade Series Heat Exchanger Operation and Installation

Operation and Maintenance Manual 120V/60HZ

Added password for IP setup page : Password must be in IP format!

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

OG5000 Ozone Generator Model OG5000B-A. User Manual

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Automatic Air Dehydrator with Ethernet Communications Model ADH NETCOM

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

Energy management function at adsorption dryer PDAD

Static Pressure Control

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

Aerosol Inlet Dryer. User s manual. Part Number: AE33-AEDN. User's manual Version 1.5 December /30

Multi-Function Cooktop

RCS Residential Control Systems Inc.

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

Across-the-Line SERIES MP300 Combined Manual and Automatic

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

M Series Fan Filter Units

REF Series Undercounter Refrigerator

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

R100 Oil-Less Refrigerant Recovery Unit

User Instruction Manual

Model 76 Dehumidifier Control Installation Instructions

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

52 BARSTOW CEILING FAN

PBI Manual. Paradox to KNX-BUS Interface

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

CommStat 4 Controller

30.45 Electric Release PDRP-2001

SYSTEM ENHANCEMENT MODULE

1U ULTRA Compact System

Installation, Operation & Service Manual

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

Transcription:

SAHARA2A-HP SERIES DryLine DEHYDRATOR USER MANUAL Bulletin AE01B-A0597-001 Rev: B 2014 CommScope, Inc. All rights reserved (02/14)

Tabel of Contents Section 1 General Information....................................... 4 1.1 Introduction.........................................4 1.2 Description....................................................4 1.3 Theory of operation..............................................4 Figure 1 Discrete Alarm Terminal Strip with Summary Alam..................5 Figure 2 Summary Alarm Terminal Strip.............................. 5 Figure 3 Pin and Jumpers Location................................. 6 1.5 Specifications SAHARA2A-HP Series Dehydrator..........................6 Section 2 Installation............................................. 7 2.1 Unpacking and Inspection..........................................7 2.2 Controls and Displays.............................................7 2.2.1 Event Log Codes................................................7 2.3 Installing the Dehydrator...........................................7 2.3.1 Set on bench or the floor.......................................... 7 2.4 Power Connections..............................................7 2.4.2 Test the Dehydrator..............................................8 2.4.1 AC Power.....................................................8 2.5 Connecting the Alarm Outputs.......................................9 2.6 Connecting Dehydrator to the Transmission Line...........................9 2.6.1 SAHARA2A-HP Series System configuration diagram Basic...................9 Figure 4 SAHARA2A-HP........................................9 Series System configuration diagram Basic..............................9 2.6.2 SAHARA2A-HP Series System configuration diagram Multi-Line............... 10 2.6.3 Pressure Monitoring and Control.................................... 10 2.6.4 Dehydrator Duty Cycles.......................................... 10 2.7 Purging the Transmission Line......................................10 Figure 5 SAHARA2A-HP Series.................................. 10 System configuration diagram Multi-Line............................... 10 2.8 PC Interface to B-Version Dehydrator Control Board....................... 11 Section 3 Maintenance...........................................13 3.0 Maintenance..................................................13 3.1 Preventive Maintenance.......................................... 13 3.2 Dehydrator Filter Element Replacement............................... 13 3.2.1 Replace the coalescing filters.......................................13 3.3 Annual Inspection.............................................. 13 3.3.1 Check the electrical connections..................................... 14 3.3.2 Check the ground wire........................................... 14 3.3.3 Check the hour meter............................................14 3.4 Parts Replacement and Dehydrator Overhaul............................ 14 3.4.1 In Case Of Difficulty:............................................ 14 3.4.2 Tools....................................................... 14 3.4.3 Overhaul Procedure.............................................14 3.4.4 Unit Shutdown and Removal....................................... 15 3.4.5 Unplug the unit from the power supply................................. 15 3.5 Service Restoration RECOMMENDATION:..............................15 Section 4 Troubleshooting......................................... 16 Figure 6 Electrical Diagram SAHARA2A-HP...........................17 Figure 7 Pneumatic Diagram..................................... 18 2

Section 5 Replacement Parts....................................... 19 Overhaul Kit SAHARA2A-HP-KIT-OVRHL.............................. 19 Filter Element Replacement Kit..................................... 19 SAHARA2A-HP-KIT-ELMNT....................................... 19 Filter Bowl Assemble Replacement.................................. 19 Kit SAHARA2A-HP-KIT-FLTRS..................................... 19 Dryer Tube Replacement Kit.......................................19 SAHARA2A-HP-KIT-DRYER....................................... 19 Solenoid Replacement Kit SAHARA2A-HP-KIT-SOLND..................... 19 Section 6 Customer Service........................................ 19 6.0 Introduction...................................................19 6.1 In Case of Trouble.............................................. 19 6.2 Initial Steps by CommScope....................................... 20 6.3 Repair Center Process........................................... 20 6.4 RoHS Inquiries................................................ 20 3

Section 1 General Information 1.1 Introduction This manual contains the information you need to install, operate and maintain your SAHARA2A-HP Series DryLine Dehydrator. Please take the time to read this manual before attempting to operate or service the unit. CAUTION: This appliance is not intended for access by the general public. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. 1.2 Description SAHARA2A-HP Series dehydrators provide dry air for pressurizing large (2830 to 31,150 liters (100 and 1100 ft 3 ), antenna and transmission line systems. The dehydrators produce -45ºC (-50ºF) dew point dry air at a nominal volumetric flow rate of 56.3 SLPM (2.0 SCFM). Each dehydrator consists of an electrically driven air compressor, a membrane dryer assembly, an automatic transmission line pressure sensing system, and alarm outputs housed in a rigid metal chassis. It is designed as a free-standing unit. The front panel features a control interface with display for alarms and pressure. For easy serviceability, power connections, alarm output connections, and all filter elements are accessible from the outside. The SAHARA2A-HP Series maintains transmission line pressures over a programmable range of 7 kpa 4 to 102 kpa ( 1 psig to 15 psig). The factory default pressures are on at 14kPa (2 psig) and off at 34 kpa (5 psig). It is intended for standard microwave antenna/broadcast applications and any other transmission line pressurization requirement that supports a medium pressure limit. 1.3 Theory of operation The SAHARA2A-HP series of DryLine Dehydrators, while similar in moisture removal technology, operates differently than some of the DryLine series of dehydrators. In order to maintain a positive constant level of pressure to medium air volume systems, and to maintain an acceptable dryness level in the product air stream, a downstream pressure sensor is utilized for controlling the operation of the unit. This feedback controlled sensor prompts the unit to engage at the lower programmed limit or at the factory default setting of 14 kpa (2.0 psig) and shut down at the upper programmed limit or the factory default of 34 kpa (5.0 psig). In addition to monitoring the downstream flow, the system is also set up to utilize the downstream air volume to provide the dry air for the feedback loop. The feedback loop is necessary to maintain the dryness of the membrane cartridge and will consume a small percentage of the air supplied by the dehydrator. During normal operation, the bleed air in the feedback loop will cause the pressure to slowly drop in the downstream air volume, and the SAHARA2A- HP compressor will cycle automatically. The dehydrator will only cycle off when it sees a down stream pressure equal to the upper programmed pressure limit or the factory default of 34 kpa (5.0 psig). The rate of these cycles, however, will vary based on system volume and overall system leak rate. When connected to a normal system, the dehydrator s duty cycle should not exceed 10% and will maintain the system pressure between the programmed limits or the factory defaults of 14 kpa (2.0 psig) and 34 kpa (5.0 psig). If the duty cycle significantly exceeds 10%, check the system for leaks. When open to atmosphere, the dehydrator will run continuously and provide approximately 56.3 SLPM (2.0 SCFM). The display will also reflect a pressure between 0 and 102 kpa (15 psig) while the output flow is between 0 and 56.3 SLPM (2.0 SCFM). The pressure sensor measures pressure at the Remote Pressure Sense port and will show the actual pressure in the transmission lines (or to the distribution manifold).

1.4 Alarms The SAHARA2A-HP offers Low Pressure, and Excess Run alarms as a standard feature. In addition, a summary alarm connection is provided on all units. Additional alarms are available in the discrete alarm version SAHARA2A-HP. These include High Humidity and Power Fail alarms. All four alarms, plus the summary alarm, have discrete connection contacts. Alarm conditions are indicated on the display. The alarms are Form C dry contacts and have connection options for Normally Open (NO) or Normally Closed (NC) configurations. The external alarm monitoring system (supplied by others) is connected to the terminal strip located on the rear of the cabinet. A small slotted screwdriver is necessary to make the connections. 1 WIRE FUNCTION REFERNCE WIRE TERMINAL COLOR ALARM FUNCTION 3 SUMMARY NC 2 SUMMARY COM 1 RED SUMMARY NO Figure 2 Summary Alarm Terminal Strip Alarm Definitions: 1 Summary The connections to the alarm strip are as follows; refer to Figure 1 for correct locations and colors of the wires on the terminal strip. 1 Discrete Summary: Power Fail: Activates when the Excess Run, and/or Low Pressure alarms are triggered. It will also report High Humidity if unit is equipped with full alarms. The summary alarm does not report Power Fail. Activates when power is removed from the dehydrator. This includes turning the power off at the switch. Figure 1 Discrete Alarm Terminal Strip with Summary Alam DISCRETE WIRE FUNCTION REFERNCE WIRE TERMINAL COLOR ALARM FUNCTION 1 EXCESS RUN NO 2 TAN EXCESS RUN COM 3 BLUE EXCESS RUN NC 4 BROWN HIGH HUMIDITY NO 5 PINK HIGH HUMIDITY COM 6 GREEN HIGH HUMIDITY NC 7 POWER FAIL NO 8 VIOLET POWER FAIL COM 9 RED POWER FAIL NC 10 ORANGE LOW PRESSURE NO 11 YELLOW LOW PRESSURE COM 12 GRAY LOW PRESSURE NC 5 High Humidity: Excess Run: Low Pressure: Activates when system or dehydrator output humidity rise above 7.5% relative humidity. At initial installation, this alarm will continue to alarm until the system has been properly purged. Factory strapped run time set in accordance with the normal run time for the dehydrator application. Selectable times are 1, 10, 30, 120 and 240 minutes, with the 10 minute selection used on the SAHARA2A-HP as the default setting. If system pressure falls below the lowpressure trigger point (7 kpa (1.0 psig) on the SAHARA2A-HP), the low-pressure alarm sensor will activate an alarm contact. This alarm is an indication of a significant system leak or a dehydrator failure. Note: All of the alarms clear and reset automatically, but can be manually reset in the display menus. However, if the alarm condition still exists, the alarm will return immediately after being reset.

USB P1 NOT IN USE HIGH PRESSURE SENSOR U2 Vdc INPUT P2 (MR050B ONLY) HUMIDITY SENSOR P3 COMP OUTPUT P4 SOLENOID (FILTER DRAIN) P6 AC MAIN [ [ LOW PRESSURE SENSOR U4 48 Vac COMP OUTPUT P7 (MR050B ONLY) SUM ALARM P8 (NO/NC) KEYPAD J4 DISCRETE ALARMS P9 (NO/NC) Figure 3 Pin and Jumpers Location 1.5 Specifications SAHARA2A-HP Series Dehydrator Output Pressure, kpa (psig) Output capacity programmable between 7 and 102kPa (1 and 15psig) 56.6 SLPM (2.0 SCFM) (total, approx.) Dimensions Height, mm (in) w/feet 292 (11.5) without feet 267 (10.5) Width, mm (in) 432 (17.0) Depth, mm (in) 381 (15.0) Net weight, kg (lb) 24.95 (55.0) Output Dew Point, -45 C (-50 F) or better Operating Temperature Range Electrical Input SAHARA2A-HP SAHARA2A-HP -10 to 40 C (14 to +104 F) 230 Vac, 60 Hz 230 Vac, 50 Hz Alarms Power Fail Alarm (optional) High Humidity Alarm Set Point (optional) Excess Run Alarm loss of input power 7.5% RH, factory set 10 minutes, factory set Output Connector 3/8 polytube, compression Low Pressure Alarm, kpa (psig) 6.9 (1.0) - Programmable 6

Section 2 Installation 2.1 Unpacking and Inspection Open carton. Keypad Controls: Advances display (scrolls ahead) to the next display or program mode with out changing the values in the microprocessor memory. Enters into the microprocessor memory the values displayed in the window and advances display (scrolls ahead) to the next program or display mode. Numerically increase displayed settings in display window. When depressed longer than 1/2 second scrolling will occur at a faster rate. Numerically decrease displayed settings in display window. When depressed longer than 1/2 second scrolling will occur at a faster rate. Remove the top piece of foam packaging. Carefully remove the installation accessories and manual and dehydrator. Check the dehydrator for shipping damage such as dents or loose parts. 2.2 Controls and Displays Default password is 1111 Familiarize yourself with the controls and displays prior to installing or testing the dehydrator. 2.2.1 Event Log Codes EV= 0 EV= 1 EV= 2 EV= 3 Used to allow the user quick access to the system event log. Event = Power Up Event = High Humidity Alarm Event = Excessive Run Time Alarm Event = Low Pressure Alarm EV= 4 EV= 5 EV= 6 EV= 7 EV= 8 Event = High Pressure Alarm Event = Compressor Fault Event = Log Cleared Event = Powering Down Event = Compressor Lifetime Eeprom Fail 2.3 Installing the Dehydrator 2.3.1 Set on bench or the floor 2.4 Power Connections Confirm your dehydrator electrical input matches the available power. 7 Ensure an electrical safety ground is installed on the ground stud located adjacent to the power input connector. (It is intended to be customer installed in the field to your halo grounding system.)

SAHARA2A-HP 230 Vac, 60 Hz 230 Vac, 50 Hz 2.4.1 AC Power AC units should be connected into a standard 30 amp power receptacle of the proper voltage. Make sure the power circuit is properly grounded. CAUTION: This unit is designed for connection to a single phase power source. Connection to a 3 phase power source will cause significant damage to internal components. 2.4.2 Test the Dehydrator Ground Stud CAUTION: Proper electrical connection is required. It is suggested a licensed electrician be contracted to connect the AC wiring to the unit, if it is connected directly to the mains. Failure to properly connect the power wires could result in a dangerous electrical shock hazard. Turn the dehydrator ON and check the output port on the rear of the unit after five seconds of operation to make sure air is flowing. Programming: 1. With the unit turned ON: 2. Press SELECT until the screen reads PROGRAM MODE 3. Press the ENTER button 4. The screen will read PASSWORD 5. Press the up arrow until a 1 is displayed. Press the enter button. Repeat until 1111 is displayed and press enter. 6. The screen will then read Change XR TIME 7. Use the up and down arrow buttons to increase or decrease the excess run time alarm setting and press enter when the desired value is reached. 8. The screen will then read CHANGE STOP PRESSURE 9. Use the up and down arrows to adjust the stop pressure (this must be a value larger than the start pressure) to the desired setting and press the ENTER button CAUTION: THE END USER IS RESPONSIBLE FOR VERIFYING THE PRESSURE LIMITS OF THE TRANSMISSION LINE AND ANTENNA SYSTEM. DAMAGE CAN OCCUR IF THE SYSTEM IS OVER PRESSURED. 10. The screen will then read CHANGE START PRESSURE 11. Use the up and down arrows to adjust the start pressure (this must be a value smaller than the stop pressure) to the desired setting and press the ENTER button 12. The screen will then read CHANGE ALARM HIGH 13. Use the up and down arrows to adjust the HIGH ALARM pressure (this must be a value larger than the stop pressure) to the desired setting and press the ENTER button 14. The screen will then read CHANGE ALARM LOW 15. Use the up and down arrows to adjust the LOW ALARM pressure (this must be a value smaller than the start pressure) to the desired setting and press the ENTER button 16. The screen will then read CHANGE PASSWORD. 17. Press the SELECT button to return to normal operation. 8

2.5 Connecting the Alarm Outputs 1 Summary To connect the alarms, locate the terminal block (TB-1) on the rear of the unit. 1 Discrete Place alarm connection wires in proper terminals and tighten the screw on the terminal block. (See section 4) The relay contacts are rated at 2 A (non-inductive), 30 Vdc. 2.6 Connecting Dehydrator to the Transmission Line CAUTION: Check the antenna and transmission line system pressure rating before connecting the dehydrator to the system. Insert one end of the 3/8 poly tube feed line tubing into the fitting on the dehydrator output port. Connect the other end of the poly tube to the transmission line. Connect the Remote Pressure Sense Line Tubing. Insert a single tubing run from the transmission line into the fitting on the rear of the unit marked "Remote Pressure Sense Line". Install the isolation shutoff valves. The valves when used on output lines, allow the system to retain pressure while the system is removed for servicing. Place each valve in line between each output and transmission line. Install the Output line and the Remote Pressure Sense Line in separate ports on the gas inlet. If a second port is not available, install a tee in the gas inlet at the transmission line and connect both the outlet and Remote Pressure Sense Line to the tee. However, this type of connection could cause excessive back pressure in the dehydrator, causing it to short - cycle. 9 Insert one end of the 3/8 poly tube feed line tubing into the fitting on the dehydrator output port. Connect the other end of the poly tube to the transmission line. Connect the Remote Pressure Sense Line Tubing. Insert a single tubing run from the transmission line into the fitting on the rear of the unit marked "Remote Pressure Sense Line". Install the isolation shutoff valves. The valves when used on output lines, allow the system to retain pressure while the system is removed for servicing. Place each valve in line between each output and transmission line. Install the Output line and the Remote Pressure Sense Line in separate ports on the gas inlet. If a second port is not available, install a tee in the gas inlet at the transmission line and connect both the outlet and Remote Pressure Sense Line to the tee. However, this type of connection could cause excessive back pressure in the dehydrator, causing it to short - cycle. * CAUTION: Do not operate the unit with the Remote Pressure Sense Line disconnected, this may result in an over pressure condition. Also be sure that any Isolation Shut-Off Valves are open before operating the unit. 2.6.1 SAHARA2A-HP Series System configuration diagram Basic * SAHARA Dehydrator This configuration shows proper hook up for systems when only a single waveguide is required in the system. Remote Pressure Sense Line * Isolation Shut-off Valves Dehydrator Output Line Figure 4 SAHARA2A-HP Series System configuration diagram Basic Primary Large Wave Guide

2.6.2 SAHARA2A-HP Series System configuration diagram Multi-Line This configuration shows proper hook up for systems when more than a single wave waveguide is required in the system. For larger systems, a 6- output manifold can be added. This diagram can also be used for hooking a DP-4A-001 or 6600D Series or LM400 Series Manifold to the system. Note: If the transmission lines have not been purged, continue with section 2.7. Otherwise proceed to section 3. 2.7 Purging the Transmission Line Air in the transmission line system must be replaced with dry air to ensure satisfactory operation of the transmitted signal. * Remote Pressure Sense Line * Isolation Shut-off Valves Primary Large Wave Guide 1. Determine the total system volume. 2. Divide the system volume by the flow rate of the dehydrator 3398 SLPH (120 SCFH) to determine the number of hours needed for one purge cycle. 3. Open the far end of the transmission line. SAHARA Dehydrator Dehydrator Output Line Tee Fitting 4. Operate the dehydrator for no less than three purge cycles. If it is not possible to open the far end of the transmission line, follow these steps: Any other Monitor or Manifold can be used in this location to expand the system. DP-4A-001 or 6600D or L6600D or LM400 Series Manifold 2.6.3 Pressure Monitoring and Control Pressure Monitoring Points Outputs to other Wave Guides Figure 5 SAHARA2A-HP Series System configuration diagram Multi-Line 1. Connect the dehydrator to the transmission line and pressurize the system. The system pressure should reach 34 kpa (5.0 psig) or the programmed upper limit. 2. Wait 15 minutes while the air absorbs moisture in the system, then disconnect the dehydrator from the transmission line and allow the air to vent. 3. Repeat steps 1 and 2 twelve times to purge the system. Dehydrator output pressure is monitored at the transmission line on all models by the "Remote Pressure Sense Line" port on the rear of the unit. 2.6.4 Dehydrator Duty Cycles The dehydrator is programmed at the factory to start when the output pressure of the dehydrator drops to 13.8 kpa (2 psig) and stops when the pressure reaches 34.5 kpa (5 psig). The SAHARA2A-HP can be programmed to provide up to 102kPa (15 psig) of output pressure. Some system components, however, have lower pressure ratings and can be damaged by application of pressures above their design limits. It is the end users responsibility to ensure pressures are set so the system is not damaged. If this is the case please contact CommScope Customer service. 10

2.8 PC Interface to B-Version Dehydrator Control Board 1. Turn off dehydrator remove top cover; connect a USB 2.0 and mini-usb cord between the computer and the dehydrator control board. The mini-usb connector is found on the upper left corner of the controller board and is marked "USB". (See image below). 2. Once the unit is powered up and connected to the computer, a Found New Hardware Wizard may open. Select No, not this time and click Cancel. 3. Go to the Start menu > select Programs > Accessories > Communications > HyperTerminal. 4. The HyperTerminal will ask for a Connection Description Name. This is not relevant for this device, so type anything into this field; it will not be useful once the board is disconnected from the computer. A new connection will need to be established every new time that the unit is connected. 5. Choose the virtual com port from the drop-down list. It should be Com3 or Com4 for the first time that you load firmware; click Next. 6. In the Port Settings screen, change the Bits per Second setting to 19200 and change the Flow Control setting to None. 7. Turn Caps Lock on. Type ID into the blank field and hit enter. The program should respond with a list of data including serial number, hardware and firmware version, etc. If it does not respond with this, your connection did not work. The virtual com port selection is generally the issue here. Start a new connection and try again. 8. Once successfully connected, you can enter HELP to view a list of commands. 9. In order to access your unit s entire event log, click on Transfer on the command bar at the top of the page. Click on Capture Text in the dropdown menu and then choose a location on your computer to store the text file. Type in GLOG and hit enter. Click on Transfer again and click on Transfer Text and select Stop from the side-scroll menu. 10. Open the text file from the storage location. Copy the entire text to MS Word to view the event log correctly. 11. When viewing events on the display of the unit, the following codes will be shown. 12. For each additional unit that is logged into with Hyper Termmal, the virtual Com port will increment by one. If the first unit is Com3, the next will be Com4 and so on LCD Reference in code Log download string EV= 0 - LOGEV_POWERUP Event = powering up EV= 1 - LOGEV_HH_ALM Event = humidity alarm trip" EV= 2 - LOGEV_XR_ALM Event = excessive run time alarm trip" EV= 3 - LOGEV_LP_ALM Event = low-pressure alarm trip" EV= 4 - LOGEV_HP_ALM Event = high-pressure alarm trip" EV= 5 - LOGEV_CP_ALM Event = compressor fault trip" EV= 6 - LOGEV_CLR Event = log cleared" EV= 7 - LOGEV_PWRDWN Event = powering down EV= 8 - LOGEV_CL_FAIL Event = Comp lifetime eeprom fail" 11

Left blank for notes 12

Section 3 Maintenance 3.0 Maintenance The SAHARA2A-HP Series Dehydrator requires relatively little maintenance to ensure satisfactory operation over long periods of time. This section outlines the recommended annual preventive maintenance for the unit and the suggested overhaul for every 6000 hours of compressor operation. 3.1 Preventive Maintenance The annual maintenance of a SAHARA2A-HP Series consists of a preventative maintenance inspection of the dehydrator and replacement of the felt air intake filter if necessary. These tasks can easily be performed in the field with the unit connected to the transmission line system and with only the front and top corner opened for maintenance. In addition to the annual inspection, a complete overhaul is recommended every 6000 hours or sooner if local conditions warrant. CAUTION: Do not apply oil or other chemicals to the filter element. Make sure the element is seated completely in the housing and then replace the cover. Discard old elements. 3.3 Annual Inspection Warning: Electrical Hazard! Unplug power cord before servicing unit. 3.2 Dehydrator Filter Element Replacement Inspection includes checking for loose or damaged hoses, fittings and electrical connections. Open the top cover and front door and verify that there is no significant water build-up in the two filter bowls located inside the front cover of the dehydrator. There may be some droplets of water in the filter bowls (the lower portion of each bowl), but there should be only a small amount of liquid in either bowl. 3.2.1 Replace the coalescing filters Remove front cover, turn filter bowl housing CCW, to remove coalescing filters element. No need to remove any hoses. From the front of the dehydrator, the left coalescing filter is 5.0 micron and the right coalescing filter is 0.01microns. The coalescing elements should be replaced every 6000 hours of operation. To replace filter coalescing elements due things in reverse orders. 13

If there is excessive water, refer to the troubleshooting section 4. Replacement of the elements in the coalescing filters is covered in the maintenance section of this manual. 3.3.1 Check the electrical connections. Check the screw at the power input connector to ensure that the AC power cord is securely terminated. Check the screw-in alarm terminals to ensure that all wire connections are tight. A loose or damaged connection may result in erratic operation and unnecessary downtime. Refer to the troubleshooting section 4 if an electrical problem is encountered. 3.3.2 Check the ground wire Check that an electrical safety ground is installed on the stud on the rear of the dehydrator. This connection point is adjacent to the power input connector. (It is intended to be customer installed to the halo grounding system.) 3.3.3 Check the hour meter Check the hour meter on the display to determine the duty cycle of the dehydrator. If the dehydrator has been running for more than 10% of its installed time, check the systems for leaks. Also check the time on the meter to determine if it is time to perform the 6000-hour overhaul. 3.4 Parts Replacement and Dehydrator Overhaul CommScope SAHARA2A-HP Series DryLine Dehydrator are designed to give many years of trouble-free service and require very minimal maintenance. The dehydrator contains, as a standard feature, an hour meter that records compressor run hours. To ensure continuous and reliable operation, the dehydrator must be overhauled every 6000 hours of compressor operation. The kits, shown in Section 5, contain all of the necessary parts to perform this overhaul. The dehydrator overhaul kit includes parts to overhaul the compressor and critical components in the dehydrator that often become worn over time. 3.4.1 In Case Of Difficulty: If the dehydrator is not operating, refer to Section 2 on Installation and Section 4 on troubleshooting the unit. 3.4.2 Tools The following tools are used in the maintenance and overhaul procedures. Adjustable open-end wrench #2 Phillips screwdrivers Small flat-blade screw-driver 3.4.3 Overhaul Procedure When the SAHARA2A-HP compressor run time reaches 6000 hours (or a multiple of 6000 hours) it is time to replace certain items in the compressor and the air path of the dehydrator. These include the piston cups, piston seals and head gaskets of the compressor, the filter elements in the water and coalescing filters, and the tube section connecting the compressor output to the heat exchanger. In addition, if the unit gives the dryer pressure alarm, the compressor may be in need of an overhaul. This does not always coincide with the 6000 hour time frame. If the dryer pressure alarm is triggered, check the system for leaks. If no leaks are detected, the compressor will need to be overhauled. 14

3.4.4 Unit Shutdown and Removal In order to perform an overhaul on the SAHARA2A- HP Series, the unit must be turned off and removed from service. As this is being done, the low pressure alarm may activate through a reporting alarm system. Personnel monitoring such an alarm should be notified in advance so that they are aware of the fact that service is being performed. It is also necessary to disconnect the dehydrator dry air output from the waveguide system during the overhaul. If isolation valves have been installed between dehydrator/remote pressure sense line and transmission line, close valve before removing unit service to prevent pressure loss. 3.4.5 Unplug the unit from the power supply. Follow the instructions included in the compressor overhaul kit. When the overhaul is complete, reinstall. Complete overhaul can be done without removing the compressor from the chassis. The compressor head, air filter, output port and relief valve can all be removed though top panel. When the overhaul is complete, reinstall. 3.5 Service Restoration RECOMMENDATION: If the dehydrator overhaul process has taken more than a few hours, it is recommended that the unit be run for one hour into the room, to purge the membrane dryer of any acquired moisture, before reconnecting to the transmission line system. 15

Section 4 Troubleshooting If you experience difficulty with your dehydrator, use the troubleshooting procedures described below. Caution: Electrical troubleshooting requires access to potentially dangerous voltages and should only be performed by a licensed electrician Problem/Condition Dehydrator display does not light, unit does not run. Low-pressure alarm activated. Compressor does not turn. Filter bowls show excessive water. Solution If the display light falls to light, make sure the unit is plugged in and power outlet is operating. If you still have no light, unplug the unit, remove the unit cover and check for loose connections. Refer to the wiring diagram for proper connections. Check to ensure that proper AC voltage is being supplied to the input. (See figure 6) Turn shut-off valve to the off position and observe pressure gauge. The pressure gauge line should read approximately 34 kpa (5.0 psig) and the alarm should clear. If alarm does not clear, remove cover and verify tubing and wiring connections are secure. (See figure 6) With dehydrator isolated from transmission line, observe pressure in transmission line. If pressure drops, use a leak detector solution to locate leaks in the transmission line. Repair leaks if possible. If the problem persists contact CommScope Customer Service. (See Section 6) Check the display on the controller. Toggle the ON/OFF switch (attached to power connection). Check input voltage per wiring diagram If the problem persists contact CommScope Customer Service. (See Section 6) Ensure that the drain line tubing (exiting the bottom of the drain solenoid) is not clogged. When the compressor cycles ON, air and moisture should flow out of the drain line (into drain pan) for a few seconds while the valve is open. If solenoid does not vent, verify proper voltage is present for the first few seconds after the compressor starts and drops to 0 volts. If proper voltage is present and solenoid does not shift, replace 16

DISCRETE ALARMS SAHARA2A-HP ONLY P9 SAHARA2A-HP ONLY HUM P3 GROUND GREEN WITH YELLOW STRIP FAN 4 BS 5 GROUND GREEN POWER ENTRY MODULE 6 GREEN 1 EMPTY SUM ALARMS P8 BS 6 Compressor PINK PINK COMPRESSOR CAPACITOR POWER RELAY BS 1 BS 2 Figure 6 Electrical Diagram SAHARA2A-HP EMI FILTER FAN FAN 3 BS 7 2 BS 8 BS 3 BS 4 EMI FILTER SPARK FILTER SOLENOID 1 SOLENOID 2 FAN 1 17

LOW PRESSURE SENSOR LINE (blue) HI PRESSURE SENSOR LINE (red) SOLENOID DRAIN PAN CONTROL BOARD DRYER ASSEMBLY SOLENOID 5.0 MICRON FILTER 0.01 MICRON FILTER COMPRESSOR BACK PRESSURE POP OFF VALVE AIR OUTPUT Figure 7 Pneumatic Diagram REMOTE SENSE HEAT EXCHANGER AIR INTAKE 18

Section 5 Replacement Parts The following is a list of the replacement kits for the SAHARA2A-HP Series dehydrators: Overhaul Kit SAHARA2A-HP-KIT-OVRHL Filter Element Replacement Kit SAHARA2A-HP-KIT-ELMNT Filter Bowl Assemble Replacement Kit SAHARA2A-HP-KIT-FLTRS Section 6 Customer Service 6.0 Introduction CommScope provides in-warranty and outof-warranty repairs as well as dehydrator and compressor overhauls from several Repair Centers. Coordination of these services is provided through the nearest Sales Office or Customer Service Center. The Center is also prepared to help you with the following: Technical Assistance Troubleshooting Repairs Loaner Units Spare Parts Installation Materials System Accessories 6.1 In Case of Trouble The first step you should take if trouble develops using a dehydrator is to read the operators manual and follow the trouble isolating procedures given in it. If the steps in the manual do not identify and remedy the problem, then contact an CommScope Customer Service Center for 24 hour telephone assistance. Model Number Serial Number Dryer Tube Replacement Kit SAHARA2A-HP-KIT-DRYER Record the Model Number (e.g. SAHARA2A-HP) and Serial Number from the product label, as you will be asked for these when you call. Two main locations are currently available to help: Solenoid Replacement Kit SAHARA2A-HP-KIT-SOLND 19 From North America Telephone: 1-800-255-1479 Fax (U.S.A.): 1-800-349-5444 International Telephone: +1-779-435-6500 Fax Number: +1-779-435-8579

Web Access Internet: www.commscope.com email: #prc@commscope.com 6.2 Initial Steps by CommScope When your call or fax communication is received, the CommScope staff will work with you to pinpoint the possible cause of trouble. If the pressurization equipment is suspect, they will: ask for your unit Model Number and Serial Number check the warranty status of the unit advise the availability of a loaner unit provide an estimate of the cost for inspection and repairs, if the unit is out of warranty fax a Return Material Authorization Sheet to you. 6.3 Repair Center Process A method of Payment must be provided prior to issuing of RMA regardless of warranty status. In Warranty Repair: Most CommScope pressurization products carry a warranty of one to three years, depending upon model number. Warranty details are available on our web page. If your unit falls within its warranty period, inspection and repairs will be performed at no charge and the unit will be promptly returned to you. If a warranty unit is deemed no problem found an inspection fee and freight will be charged to the customer. Out Of Warranty Repair: We will inform you with the cost of repair and obtain your approval to proceed with repairs or, if you elect not to have the unit repaired, your instructions on disposition of your unit. When repairs are complete, we will return your unit and invoice you for the inspection charge, materials used for the repair and labor applied to complete the repair. If you elected not to repair the unit, we will invoice you for the inspection and freight charge if unit is to be returned. your return and create the appropriate credit to your account. Damages to loaner will be deducted from the P.O. Packing Instructions: Pack your unit securely for shipment to the Repair Center. If you received a loaner unit, we suggest you use the box and packing materials to return your unit. Otherwise we have factory packing materials available for a nominal fee. Enclose a completed copy of this form inside the box and clearly mark your Company Name and RMA: XXXXXXX on outside of the box. Address the box to the following Ship To Address: COMMSCOPE PRESSURIZATION SERVICE CENTER RMA# XXXXXXX 11312 S. PIPELINE RD. EULESS, TX. 76040-6629 Please note, Units received with Biological/animal contamination will be returned unrepaired or scraped after notification and you will be invoiced for inspection and freight. Contact Numbers: If you have any questions about the repair process or status of your unit, please contact us directly through one of the following methods Telephone (below) TEL: 817-864-4150 817-864-4155 FAX: 817-864-4179 6.4 RoHS Inquiries For inquiries on RoHS please contact the following: CommScope Inc. Corke Abbey, Bray Co., Dublin, Ireland Attn: Legal Department Loaner Units: Loaner units are available from the repair center to maintain your system while repairs are being performed. If you feel you need a loaner, please contact us at at one of the numbers listed under contact numbers. A P.O. for the full value of the unit must be issued prior to shipment. Also contact us when the loaner is ready to be returned so that we can issue a NEW RMA number to identify 20