HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Similar documents
HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

System Programming Guide

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

EVO192 v3.0 Fire and Burglary What s New

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

INSTALLATION MANUAL PC56O. Version 1.OA

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

All-In-One Wireless Security System V1.0. Model #: MG-6060

Digiplex Control Panel (DGP-848) - V4.0

636 and 646 Keypads. User s Manual

Property of Monitronics Inc

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

TABLE OF CONTENTS TABLE OF CONTENTS 1

ESPRIT 616/626 KEYPADS. User Manual P R D O X S E C U R I T Y S Y S T E M S. Model 626 READY UM ESPRIT PRINTED IN CANADA 2ND TRBL

GEM-P800 Programming Instructions

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

INSTALLATION MANUAL PC15OO

ESPRIT. 616/626 KEYPADS. User Manual P R D O X. Model 626 READY S E C U R I T Y S Y S T E M S UM ESPRIT

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

INSTALLATION MANUAL PC25OO

INSTALLATION MANUAL & PROGRAM RECORD SHEET

4-PGM Expansion Module

8-zone Expansion Module

System Introduction. 1.1 Specifications

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

Light " " = TRBL MODEL 633 KEYPAD TROUBLE DISPLAY. [7] Communicator fail to report. Fire trouble. Tamper or zone wiring fail. Telephone line monitor

CC488. Quick Reference Guide Solution Ultima 880

First Alert 1200C Installer Notes M. Leuck

GEM-P800. Control Panel/Communicator. Installation Instructions

Radionics D4112 Program Sheet

System Introduction. 1.1 Specifications S E C T I O N 1

Property of Monitronics Inc

Installation Manual Premier 412/816/832. Issue 10

CC408. Quick Reference Guide Solution 880

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Quick Programmer s Manual

10-Zone Spectra LED Keypads

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

AXI LED USER MANUAL (REV. 1.0)

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Contact ID as of 2/2/2015

Programming Worksheets

Control/Communicator Installation Manual

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

CONTACT ID REPORT CODES

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

INSTALLATION MANUAL. PC3OOO Version 7.6W

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

EasyLoader AV-2004, AV Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Version 2.

Digiplex LED Keypads User s Manual

642 LCD Keypad. User Manual

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Version 1.03 January-2002 USER S MANUAL

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

32-Zone Wireless Transceiver Control Panel MG5000. User s Guide

System Manual W A R N I N G. PC6O1O Software Version 2.1

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Installation Instructions

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

VAP304 PRO INSTALLATION & OPERATION MANUAL

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

LCD and 16-Zone LED Keypads. User s Manual

2000 Series. Program Entry Guide. Control Panels

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

NetworX Series NX-4V2 Control Panel Installation and Startup

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

INSTALLATION MANUAL DV8OOO. Software Version 1.0

NX-4V2 Control Panel Installation Instructions

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Digiplex LED Keypads. User s Manual

Solution 862 Installation Manual ISSUE 1.30

Training Manual Multi-Language with Wireless

CA60Plus. Installation manual

Contact ID as of 11/28/2018

P Zone Expandable Hybrid Security System

User Guide MG5000 MG5050 SP5500 SP6000 SP7000

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

Transcription:

-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect a jumper between "reset jumper" pins. (3) Connect AC then the battery. (4) Wait 10 seconds. (5) Remove jumper. Factory default installer and master codes will be reinstated. Values entered at addresses 008-043, 062-126 and 300-527 as well as all user codes, will be erased ([2ND] [2ND]). Programmed values of all other addresses do not change. HEXA PROGRAMMING: All digits from 0 to F are valid. Values are programmed into memory locations from address 000 to 043 and from address 300 to 527. 1) Press [ENTER] installer code. 2) [ENTER] will flash (programming mode). 3) Enter 3 digit memory address. 4) Current value will be displayed on keypad. 5) Enter 2 digit data. 6) Go to step 3 for next address. To exit programming mode, press [CLEAR]. HEXA DISPLAY If key is lit = 8 = 4 = 2 = 1 If key is lit = 8 = 4 = 2 = 1 Value of 2 ND digit = 10 ( 8 2 = 10) Value of 1 ST digit = 3 ( 2 1 = 3) VALUE = "3A" No display = SKIP (empty) No light = 0 10 = [0] = [A] STREAMLINED SECTION PROGRAMMING Can be used to program s 00 to 67. (addresses 000 to 043 and 300 to 527) Press [ENTER], installer code, and [7]. ([2ND] and [ENTER] keys alternately flash.) Enter a 2-digit number, followed by 8 digits to program that (confirmation beep). Data will be saved automatically and the software advances to the next programming. To exit programming mode press [CLEAR]. INSTALLER CODE: (reset code 737373) (addresses 000, 001, 002) SECTION 00 Full access to programming, except access codes. (addresses 127-299) No access to arming/disarming. Can be used to modify installer code. Use only numeric keys from [1] to [10]. (key [10] = 0) PANEL ANSWER OPTIONS: (address 003) SECTION 00 First digit disables Answering Machine Override (key [2ND] or key [1]), or determines period of time between first and second call (see table below). Second digit determines number of rings required before panel will answer. If [2ND][2ND] is entered, panel will not answer. (Default value is [2ND] [8].) - 1 -

TELEPHONE AND ACCOUNT NUMBERS: (reset empty) If only one central station phone number is used, program the same number for telephone number 1 and 2. [10] = the number "0" [BYP] = switch from pulse to tone while dialing [11] = * [MEM] = pause 4 seconds [12] = # [TRBL] = end of number COMPUTER TELEPHONE NUMBER: (View at addresses 008 to 015.) 02 / / / / / / / 03 / / / / / / / 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Press [TRBL] to end phone number if less than 16 digits are programmed. CENTRAL STATION TELEPHONE NUMBER 1: (View at addresses 016 to 023.) 04 / / / / / / / 05 / / / / / / / 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Press [TRBL] to end phone number if less than 16 digits are programmed. CENTRAL STATION TELEPHONE NUMBER 2: (View at addresses 024 to 031.) 06 / / / / / / / 07 / / / / / / / 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Press [TRBL] to end phone number if less than 16 digits are programmed. ACCOUNT "A" AND "B": (View at addresses 032 to 035.) 08 / / / / / / 1 2 3 4 5 6 7 8 A B For 3 digit account numbers, enter "skip" ([2ND]) as first digit. If only one account number is required, the same number must be entered for both account "A" and "B". - 2 -

Data Description 09 [2 ND ] ND] [2 ND] Future use 1st digit: value must be entered i.e. 2nd digit: time correction (See table) 1st digit: telephone 1 format 2nd digit: telephone 2 format 1st digit: PGM 1 type 2nd digit: PGM 2 type [2 ND] 036 037 038 039 TIME CORRECTION: (address 037 second digit) [2 ND] - No adjustment [8] - Minus 4 sec. [1] - Plus 4 sec. [9] - Minus 8 sec. [2] - Plus 8 sec. [10] - Minus 12 sec. [3] [4] [5] [6] - Plus 12 sec. - Plus 16 sec. - Plus 20 sec. - Plus 24 sec. [11] [12] [ BYP] [ MEM] - Minus 16 sec. - Minus 20 sec. - Minus 24 sec. - Minus 28 sec. [7] - Plus 28 sec. [ TRBL] - Minus 32 sec. 10 PGM 1 PGM 2 PGM mask 1 PGM mask 2 040 041 042 043 COMMUNICATOR FORMATS Key [2 ND ] = ADEMCO slow (1400Hz, 1900Hz, 10bps) [6] [1] [2] [3] [4] [5] = (1400Hz, 1800Hz, 10bps) = SILENT KNIGHT fast (1400Hz, 1900Hz, 20bps) = SESCOA (2300Hz, 1800Hz, 20bps) = RADIONICS (40bps with 1400Hz handshake) = RADIONICS (40bps with 2300Hz handshake) [7] [8] [9] [10] [ TRBL] = RADIONICS with PARITY (1400Hz, 40bps) = RADIONICS with PARITY (2300Hz, 40bps) = ADEMCO express = ADEMCO contact ID (programmable codes) = ADEMCO contact ID (all codes) = DTMF - no handshake (personal dialing) PROGRAMMABLE CONTACT ID EVENT CODES All addresses from 300 to 527 (s 11 to 67 ) programmed with values other than [2 ND] [2 ND] will report the contact ID codes corresponding to the values programmed. Values to be programmed should be selected from this table. CID 100: 110: 111: 112: 113 114: 115: 116: 117: 118: 120: 121: 122: 123: 130: 131: 132: 133: 136: 137: 138: 140: 150: 151: 152: 153: 154: 155: 156: 157: 158: 159: 161: REPORTING CODE AUXILIARY ALARM FIRE ALARM FIRE SMOKE COMBUSTION WATER FLOW HEAT PULLSTATION DUCT FLAME NEAR ALARM PANIC ALARM DURESS SILENT PANIC AUDIBLE PANIC BURGLARY PERIMETER BURG. INTERIOR BURG. 24HR BURGLARY BURGLARY OUTDOOR BURGLARY TAMPER BURGLARY NEAR ALARM GENERAL ALARM 24 HOUR AUX GAS DETECTED REFRIGERATION LOSS OF HEAT WATER LEAKAGE FOIL BREAK ALARM DAY TROUBLE ALARM LOW GAS LEVEL HIGH TEMPERATURE LOW TEMPERATURE LOSS AIR FLOW PROG. VALUE [2 ND] / [1] [2 ND] / [2] [2 ND] / [3] [2 ND] / [4] [2 ND] / [5] [2 ND] / [6] [2 ND] / [7] [2 ND] / [8] [2 ND] / [9] [2 ND] / [10] [2 ND] / [11] [2 ND] / [12] [2 ND] / [ BYP] [2 ND] / [ MEM] [2 ND] / [ TRBL] [1] / [2 ND] [1] / [1] [1] / [2] [1] / [3] [1] / [4] [1] / [5] [1] / [6] [1] / [7] [1] / [8] [1] / [9] [1] / [10] [1] / [11] [1] / [12] [1] / [ BYP] [1] / [ MEM] [1] / [ TRBL] [2] / [2 ND] [2] / [1] CID 300: 301: 302 305: 306: 309: 320: 321: 323: 350: 351: 354: 370: 371: 372: 373: 382: 383: 400: 401: 402: 403: 404: 407: 410: 441: 570: 572: 573: 574: 601: 602: 625: REPORTING CODE SYSTEM TROUBLE AC LOSS LOW SYSTEM BATTERY SYSTEM RESET PROGRAM CHANGED BATTERY TEST FAIL SOUNDER/RELAY TROUBLE BELL 1 TROUBLE ALARM RELAY TROUBLE COMMUNICATION TROUBLE TELCO 1 FAULT FAIL TO COMMUNICATE PROTECTION LOOP TROUBLE PROTECTION LOOP OPEN PROTECTION LOOP SHORT FIRE LOOP TROUBLE SENSOR TROUBLE SENSOR TAMPER OPEN/CLOSE OPEN/CLOSE BY USER # GROUP OPEN/CLOSE AUTOMATIC OPENING/CLOSING LATE TO OPEN/CLOSE REMOTE ARM DOWNLOAD REMOTE ACCESS OPEN/CLOSE - STAY MODE BYPASS 24 HOUR ZONE BYPASS BURGLARY BYPASS # GROUP BYPASS MANUAL TEST PERIODIC TEST TIME/DATE RESET PROG. VALUE [2] / [2] [2] / [3] [2] / [4] [2] / [5] [2] / [6] [2] / [7] [2] / [8] [2] / [9] [2] / [10] [2] / [11] [2] / [12] [2] / [ BYP] [2] / [ MEM] [2] / [ TRBL] [3] / [2 ND] [3] / [1] [3] / [2] [3] / [3] [3] / [4] [3] / [5] [3] / [6] [3] / [7] [3] / [8] [3] / [9] [3] / [10] [3] / [11] [3] / [12] [3] / [ BYP] [3] / [ MEM] [3] / [ TRBL] [4] / [2 ND] [4] / [1] [4] / [2] For addresses 044 to 126, see pages 7 to 10. - 3 -

REPORTING CODES: (reset code = empty" [2 ND] [2 ND] ) All digits from [1] to [F] are valid. Enter [2 ND] (skip) = digit will not be reported except for contact I.D. programmable codes. For single digit reporting enter "skip" ([2 ND] ) as first digit. If CONTACT I.D. format (all codes) is selected, addresses 300 to 527 (s 11 to 67) do not have to be programmed. (Select Contact I.D (all codes) - key [10] for both central station numbers at 09 - address 038.) ARMING (closing) CODES: Data Description Data Description 11 Auto / Espload Master User code 1 User code 2 300 301 302 303 18 User code 27 User code 28 User code 29 User code 30 328 329 330 331 12 User code 3 User code 4 User code 5 User code 6 304 305 306 307 19 User code 31 User code 32 User code 33 User code 34 332 333 334 335 13 User code 7 User code 8 User code 9 User code 10 308 309 310 311 20 User code 35 User code 36 User code 37 User code 38 336 337 338 339 14 User code 11 User code 12 User code 13 User code 14 312 313 314 315 21 User code 39 User code 40 User code 41 User code 42 340 341 342 343 15 User code 15 User code 16 User code 17 User code 18 316 317 318 319 22 User code 43 User code 44 User code 45 User code 46 344 345 346 347 16 User code 19 User code 20 User code 21 User code 22 320 321 322 323 23 See next page User code 47 User code 48 / (Duress) 348 349 17 User code 23 User code 24 User code 25 User code 26 324 325 326 327-4 -

REPORTING CODES: (reset code "empty") DISARMING 23 (opening) CODES: Data Description See previous page Espload Master 350 351 30 Data Description User code 25 User code 26 User code 27 User code 28 376 377 378 379 24 User code 1 User code 2 User code 3 User code 4 352 353 354 355 31 User code 29 User code 30 User code 31 User code 32 380 381 382 383 25 User code 5 User code 6 User code 7 User code 8 356 357 358 359 32 User code 33 User code 34 User code 35 User code 36 384 385 386 387 26 User code 9 User code 10 User code 11 User code 12 360 361 362 363 33 User code 37 User code 38 User code 39 User code 40 388 389 390 391 27 User code 13 User code 14 User code 15 User code 16 364 365 366 367 34 User code 41 User code 42 User code 43 User code 44 392 393 394 395 28 29 User code 17 User code 18 User code 19 User code 20 User code 21 User code 22 User code 23 User code 24 368 369 370 371 372 373 374 375 35 User code 45 User code 46 User code 47 User code 48 / (Duress) 396 397 398 399 ALARM CODES ZONE 1 TO 12: Data Description 36 Zone 1 Zone 2 Zone 3 (fire) Zone 4 400 401 402 (see add. 100) 403 ALARM CODES ZONE 13 TO 24: Data Description 39 412 413 414 415 37 Zone 5 Zone 6 Zone 7 Zone 8 Keypad 1 404 405 406 407 40 416 417 418 419 38 Zone 9 Keypad 2 408 409 410 411-5 - 41 420 421 422 423

REPORTING CODES: (reset code "empty") ZONE 1 TO 12 RESTORE CODES: Data Description 42 Zone 1 Zone 2 Zone 3 (fire) Zone 4 424 425 426 (see add. 100) 427 ZONE 13 TO 24 RESTORE CODES: Data Description 45 436 437 438 439 43 Zone 5 Zone 6 Zone 7 Zone 8 Keypad 1 428 429 430 431 46 440 441 442 443 44 Zone 9 Keypad 2 432 433 434 435 47 444 445 446 447 ZONE 1 TO 12 SHUTDOWN CODES: Data Description 48 Zone 1 Zone 2 Zone 3 Zone 4 448 449 450 451 ZONE 13 TO 24 SHUTDOWN CODES: Data Description 51 460 461 462 463 49 Zone 5 Zone 6 Zone 7 Zone 8 Keypad 1 452 453 454 455 52 464 465 466 467 50 Zone 9 Keypad 2 456 457 458 459 53 468 469 470 471 TAMPER 1 TO 12 TROUBLE CODES: Data Description 54 Tamper 1 Tamper 2 Tamper 3 Tamper 4 472 473 474 475 TAMPER 13 TO 24 TROUBLE CODES: Data Description 57 484 485 486 487 55 Tamper 5 Tamper 6 Tamper 7 476 477 478 479 58 488 489 490 491 56 480 481 482 483 59 492 493 494 495-6 -

DECIMAL PROGRAMMING 3 Digit Decimal Value Programming Used to program addresses 044 to 061. Values entered must contain 3 digits between "000" and "255". ([10] = 0) Decimal value programming: 1) Press [ENTER] installer code. ([ENTER] key will flash.) 2) Enter 3 digit address (044 to 061). 3) Current value will be displayed on keypad. 4) Enter 3 digit DECIMAL value. 5) Repeat from step 2 onward for next address. To exit programming mode press [CLEAR]. 044: / (hours) Auto arm time (between "000" and "023") 045: / (minutes) Auto arm time (between "000" and "059") 046: / (days) Auto test report every? days (between "001" and "255") (000 = disabled) 047: / (hours) Auto test report (between "000" and "023") 048: / (minutes) Auto test report (between "000" and "059") - 7 -

DECIMAL PROGRAMMING 049: / (seconds) Exit delay (factory default 60 seconds) 050: / (seconds) Entry delay 1 (factory default 45 seconds) 051: / (seconds) Entry delay 2 (factory default 45 seconds) 052: / (minutes) Bell cut-off time (factory default 5 minutes) 053: / ( x 15 msec.) Zone speed (factory default 600 msec.) 054: / (minutes) Power failure report delay (factory default 30 minutes) (000 = disabled) 055: / ( x 15 minutes) "No movement" report time (factory default 8 hours) (000 = disabled) 056: / PGM timer setting (001 to 127 for seconds and 129 to 255 for minutes) (factory default 5 seconds) Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 128 = 133) 057: / Intellizone delay (in seconds, minimum = 10 seconds) (factory default 48 seconds) 058: / Installer code lock (147 = locked, 000 = unlocked) 059: / (seconds) Programmable delay before alarm transmission (5 to 63 seconds) (000 = disabled) 060: / (seconds) Recent closing delay (000 = disabled) 061: / Future Use FEATURE SELECT PROGRAMMING es 062-126. "ON"/"OFF" status of the key lights determines feature selection. In programming mode, enter 3 digit memory address (062 to 126). To save entries, press [ENTER]. To exit programming mode press [CLEAR]. Reset = OFF for addresses 062 to 126. PG738EX es 080 to 085 for future use. - 8 -

FEATURE SELECT PROGRAMMING (continued) (On/off status of key lights determines which feature is selected.) 086: See "TLM" table PS1/Keyswitch = regular arm PS1/keyswitch arming Call back Auto arm on time Auto arm on no movement Pulse dialing Partitioning Silent zone/panic generates a silent alarm (1:2) Pulse Europe See "Reporting" table Bell squawk on arm/disarm Auto zone shutdown KEY OFF / ON [2 ND] 086, Key [2 ND] [1] [1] KEY [2] stay arm / System A [2 ND ] [1] [3] enabled OFF OFF OFF ON [4] enabled ON OFF [5] enabled ON ON [6] enabled [7] Tone dialing (DTMF) [8] enabled [9] generates only a report [10] (1:1.5) Pulse USA [11] 086, Key [11] [12] [12] KEY TYPE [ BYP] [11] [12] [ MEM] [ TRBL] enabled enabled OFF OFF ON Reporting disabled Regular reporting TELEPHONE LINE MONITOR OFF ON OFF TLM disabled TLM generates trouble only generates an alarm if armed silent alarm becomes audible (address 086, key [9] has to be OFF) REPORTING OPTIONS Split reporting: Alarms System report Double reporting * DIALING SEQUENCE (tel. No.) 1,2,1,2,1,2,1,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm. 2,2,2,2,2,2,2,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm., 2,2,2,2,2,2,2,2, fail to comm. KEY ON ON 088: OFF / ON Automatic event buffer transmission [2 ND] enabled * On alarm, all reports are made to Tel. #1 until system is disarmed. (Once disarmed, system reports are made to Tel. #2) Panic 1 (keys [1] & [3], PS1) [1] enabled Panic 2 (keys [4] & [6]) [2] enabled Panic 3 (keys [7] & [9]) [3] enabled Panic 1 silent (PS1) [4] audible Panic 2 silent [5] audible TAMPER / WIRE FAULT DEFINITIONS 088, Key [10] [11] Panic 3 silent [6] fire KEY Key [10] regular arm [7] enabled SYSTEM ARMED [10] [11] SYSTEM DISARMED * Key [11] stay or system A arm [8] enabled Alarm as per individual OFF OFF Tamper supervision 6 digit access codes [9] zone definitions disabled 4 digit OFF ON No alarm, trouble code [10] Tamper Recognition Always generate trouble reported [11] and alarm, audible or ON OFF Silent alarm. Trouble and silent as per individual Beep on exit delay [12] enabled alarm codes reported zone definitions Report zone restore on bell cut-off [ BYP] on zone closure ON ON Audible alarm. Trouble and Zones with EOL (1K Ω ) [ MEM] alarm codes reported no EOL ** Always report disarm [ TRBL] only after alarm Exception: for 24 hour zones the tamper definition will follow the * audible/silent alarm definition of the 24 hour zone. KEY ** Silent zones will generate a silent alarm. 090: OFF / ON Exclude power failure from trouble display [2 ND] enabled [1] Auto arm = regular arm [2] stay / System A [3] [4] [5] No tamper bypass [6] tamper follows zone bypass definition [7] [8] Audible trouble warning [9] enabled Duress [10] enabled PS1 software version 1.1 Keypad supervision must be OFF Keypad 1 zone supervision [11] enabled Keypad software versions prior to 4.0} Keypad 2 zone supervision [12] enabled PS1 software versions 2.0 onward [ BYP] Keypad software versions 4.0 onward} Keypad supervision must be ON (See Wiring Diagram) [ MEM] [ TRBL] - 9 -

Note: Do not use the Intellizone feature and an entry delay for the same zone, otherwise an alarm may occur as a user tries to disarm the system. KEY ACCESS PROGRAMMING Programs features quickly, without entering addresses or numbers. To activate key access programming, press [ENTER], followed by installer, master or user code 1. (Code required depends on the feature you wish to access - see below.) Press the key corresponding to the desired feature. Press [ENTER] or [CLEAR] to exit. key [8] Installer test mode (installer code only) In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long) indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones. [9] "Auto arming" time program (all 3 codes) Key [9] flashes. Enter two digits (00 to 23) for hours 2 digits (00 to 59) for minutes. [MEM] "Panel time" and clear "trouble 8" (all 3 codes) Key [MEM] flashes. Enter two digits (00 to 23) for hours 2 digits (00 to 59) for minutes. [BYP] Test report (all 3 codes) Reporting is enabled at address 086, keys [11], [12]. A value must be entered at address 512, and both telephone and account numbers must be programmed. [TRBL] Call Espload via telephone (all 3 codes) Panel identifier and PC password (addresses 004-007) and computer telephone number (addresses 008-015) must be programmed. [AWAY] Answer Espload (all 3 codes) This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in "modem setup", and panel phone number programmed (works also without ADP-1). [STAY] Cancel communication attempts Until next reportable event (master code and user 1 can only stop calls to Espload) (installer code - all communications) When communicating with Espload, it is impossible to enter programming mode. - 10 -

ESPRIT 738 EXPRESS CONNECTION DIAGRAMS The system hardware will recognize the following zone conditions: Note: Keypad zones always use (1K OHM) EOL resistor. SINGLE ZONE CONNECTIONS ZONE connection, without EOL resistor (N.C. contacts) address 088, key [MEM] = "on" key [10] = "off" (reset) key [11] = "off" (reset) N.C. contacts see Figure 1 ZONE connection, with EOL resistor (N.C. and N.O. contacts) address 088, key [MEM] = "off" (reset) key [10] = "off" (reset) key [11] = "off" (reset) N.C. and/or N.O. contacts, see Figure 2 ZONE connection, without EOL resistor, with tamper recognition (N.C. contacts) address 088, key [MEM] = "on" key [10] = See "Tamper/wire Fault Definitions key [11] = and Options" Tamper transmits separate code, see Figure 3 ZONE connection, with EOL resistor, with tamper recognition, and with wire fault (short circuit) recognition (N.C. contacts) address 088, key [MEM] = "off" key [10] = See "Tamper/wire Fault Definitions key [11] = and Options" Tamper/wire fault transmits separate code, see Figure 4-11 -

ESPRIT 738 EXPRESS WIRING DIAGRAM Service Keypad AUX - GRN YEL Caution: Disconnect battery before replacing fuse. Four pin connector canbeusedfor quick installation of an Esprit keypad. BATT 5AMP Charging and battery test LED (every 60 seconds) RESET JUMPER PARADOX SECURITY SYSTEMS ESPRIT 738 EXPRESS "TLM" LED: Short flash = OK Long flash = Fault SERIAL OUTPUT DIALER OFF = Disabled Constant = On Line - BLACK RECHARGEABLE BATTERY RED BATT BELL RELAY OPTION UL/ULC 12VDC / 7AH To cabinet and grounding rod SERVICE KEYPAD COM N.C. N.0. AC PG1 PG2 BELL - AUX - GRN YEL 1 C 2 3 C 4 5 C 6 C 7 R-1 T-1 RING TIP N.O. contacts 1KΩ EOL GRY BRN RED GRN Warning: Disconnect telephone line before servicing. RJ31X CA 38A UL: K12 model T16 V4O ULC: Frost model FTC 1637 Warning: Improper connection may result in damage to the system. TRANSFO 16.5VAC 40VA A.C. POWER BELL OUTPUT will shut down if current exceeds 3A. BELL SIREN UL/ULC Wheelock 46T-12 - - Smoke and heat detectors YEL GRN BLK RED AUX POWER 400mA max. 250mA max. for 24 hr. standby. To connect additional wiring to auxiliary power, use the red () and black (-) keypad connectors. Aux power will shut down if current exceeds 1A. 100 * Zone 3 = Fire zone if zone definition is "24 hour". * ZONE 8or9 N.O. 1KΩ EOL N.C. * PS1 software version 1.1 Keypad software versions prior to 4.0 Keypad supervision must be OFF PS1 software versions 2.0 onward Keypad software versions 4.0 onward } } Keypad supervision must be ON (See 090, key [11] [12]) N.O. 1KΩ EOL ZONE 8or9 N.C. P R RMED RE DYDOX MAX 5 per system PS1 1KΩ EOL KEYPAD 639/640 MAX 2 per system The 640 keypad can be used with the panels but will not display correct event list codes. N.C. N.C. ZONE 8 ZONE 9 KEYPAD 616/626/633 MAX 5 per system For resistor values, refer to 639/640 installation manuals. FIRE RESET To program PGM1 to conduct 4 second smoke detector reset when [ CLEAR] and [ ENTER] are pressed simultaneously: 039 = [ BYP] (first digit) 042 = [2 ND] [6] 040 = [5] [10] 056 = [10] [10] [4] Keyswitch can be used in parallel with keypad (Not on UL systems). KEYSWITCH CONNECTION 220Ω KYPD GRN KEYSWITCH KYPD BLK FIRE ALARM ZONE CONNECTIONS * PGM maximum 50mA GROUND START CIRCUIT PGM OUTPUT RELAY * PGM AUX Smoke detector - Z3 COM Smoke detector - WHT BLK PGM RED AUX WHT BLK PGM RED AUX MR3-UL MR3-UL Smoke detector power supervision relay, 12VDC 1KΩ EOL Smoke detector must be 4 wire latching - UL Falcon model 5454, ULC BRK 2412. Power supervision relay model MR3-UL. RNG YEL COM BRN N.C. N.O. YEL SECURITY SYSTEMS 780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (514) 491-2313 http://www.paradox.ca Paradox Security Systems Graphic Dept PRINTED IN CANADA