Tube-in-tube heat exchanger Type HE

Similar documents
Tube-in-tube heat exchanger Type HE

Check valve Types NRV and NRVH

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Enthalpy Charts

General information on refrigerant controllers

CHECK VALVES INSTALLATION

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Bulletin , March Electric Hot Gas Bypass Valves

Thermostatic expansion valves for ammonia Type TEA

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Liquid Distributor Type RD

Energy Use in Refrigeration Systems

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

Filter Driers with Replaceable Core

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Low Pressure Sight Glass Up to 35 bar MWP Type SG

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Compendium DES July 2016, CARN

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Figure 1: Overview of CO 2 evaporator types

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

CONDOR-H (horizontal) / CONDOR-V (vertical)

Danfoss Scroll for Refrigeration MLM / MLZ

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Low GWP Refrigerants for Air Conditioning Applications

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

FACT SHEET 9 Large Air-Conditioning (air-to-air)

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Otherwise, you can continue reading the file on the following pages.

Stainless steel refrigerators & freezers

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

Checking the Charge on a Heat Pump in the Winter

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

C22 Bulletin # October 1993 Supersedes May 1993

RCTA Horizontal Evaporator Coil Installation Instructions

High temperature air-to-water heat pumps

Product Catalog VALVES

OIL SEPARATORS APPLICATIONS

PULSE WIDTH MODULATING VALVES

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

The Saturation process

Suction Line Accumulators

Refrigerants and lubricants

BRA FACT FINDER Number 19

APPLICATION and INSTALLATION

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

AHRI Standard 751 (SI) 2016 Standard for Performance Rating of Thermostatic Refrigerant Expansion Valves

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

LAB EQUIPMENT DETAILS

Kirby CO 2 Evaporators

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

of the liquid prior to it entering the expansion device. By doing so, the capacity for

Packaged Terminal Air Conditioners

Commercial Refrigeration

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Test Report No.: Page 2 of 14

Gary Parker Refrigerants Product Manager

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Suction Accumulators. Introduction. Suction Accumulators

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

AE October 1965 Reformatted October Hot Gas Bypass Control Systems

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

for Valve Types P-H-M-V-W-D-A

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

PPL Electric Utilities Energy Efficiency and Conservation Program

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

Transcritical CO2 Bottle Cooler Development

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Brazed Plate Heat Exchanger for CO Applications

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Large AC units using a variety of low-gwp options

Process glycol chillers

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls

RAC. Unit 1. Previous year Questions

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

Technical Information

Refrigerant air dryers. FD series ( l/s, cfm)

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Be sustainable while protecting your business

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

Transcription:

MAKING MODERN LIVING POSSIBLE Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration plant. The purpose is to utilise the cooling effect, utilise which without a heat exchanger is otherwise lost to the ambient air via uninsulated suction lines. In the heat exchanger, this effect is used to subcool the refrigerant liquid. Features y High refrigeration capacity in evaporator y Helps ensure vapour-free liquid ahead of the expansion valve y HE 0.5-.5: Compliant with ATEX hazard zone 2 y Maximum utilisation of the evaporator upon setting the thermostatic expansion valve for minimum superheat. y Helps prevent sweating and frosted-up suction lines. Approval GOST AN30 DKRCC.PD.FD0.A8.02 / 520H8754

Technical data Refrigerants HE 0.5 -.5: HCFC, HFC and HC HE 4.0-8.0: HCFC and non-flammable HFC Operating temperature -60 20 C Max. working pressure Max. test pressure HE 0.5, HE.0, HE.5, HE 4.0: PS/MWP = 28 bar HE 8.0: PS/MWP = 2.5 bar HE 0.5, HE.0, HE.5, HE 4.0: Pe = 40 bar HE 8.0: Pe = 28 bar Ordering Solder connection ODF Type Liquid line Suction line Code no. [in.] [mm] [in.] [mm] HE 0.5 HE.0 HE.5 HE 4.0 HE 8.0 6 2 05D000 / 4 / 2 05D0002 0 6 05D0003 3 / 8 5 / 8 05D0004 2 8 05D0005 / 2 3 / 4 05D0006 2 28 05D0007 / 2 / 8 05D0008 6 42 05D0009 5 / 8 5 / 8 05D000 Generally, the size of an HE heat exchanger can be determined from the connections corresponding to the pipe dimensions of the refrigeration plant. The design is such that normal suction gas velocities are achieved, with a subsequent small pressure drop. Thus the heat exchanger capacity will match plant capacity. At the same time, oil return to the compressor is ensured. If the main object is to avoid sweating and frosting-up of the suction line, the HE can be chosen one size larger than the size determined by the capacity. An HE used as an auxiliary condenser must always be selected according to the connection dimensions. 2 DKRCC.PD.FD0.A8.02 / 520H8754

Capacity R22 R34a 5D5. 5D50. R404A 5D52. DKRCC.PD.FD0.A8.02 / 520H8754 3

Capacity (continued) Precise heat exchanger sizing can be obtained from the curves which show plant capacity Q e for R22, R34a and R404A depending on evaporating temperature t e. Example Plant capacity Q e = 4.5 kw Refrigerant = R22 Evaporating temperature t e = -25 C The curve for R22 shows that an HE 4.0 is suitable. The curve for HE 4.0 lies immediately above the intersection of the lines through Q e = 4.5 kw and t e = -25 C. Heat flow Q during heat exchange is calculated from the formula: Q=k A t m Q heat flow in [W] k heat transfer coefficient in [W/m 2 ] A transfer area of the heat exchanger in [m 2 ] t m average temperature difference in, calculated from the formula: t m = ln t max. - t min. t max. t min. k A values Determined by experiment (see table). K A Type Dry suction gas / refrigerant liquid ) (normal use in refrigeration plants with fluorinated refrigerants) [W] / HE 0.5 2.3 HE.0 3. HE.5 4.9 HE 4.0.0 HE 8.0 23.0 ) These figures apply to dry gas only. Even if a thermostatic expansion valve is used, the suction gas will carry very small liquid drops into the suction line. The fins of the HE catch these drops which then evaporate. This may result in a smaller superheat than the theoretically calculated value. 4 DKRCC.PD.FD0.A8.02 / 520H8754

Design / Function 6D36.4. Suction line connection 2. Liquid line connection 3. Inner chamber 4. Outer chamber Offset fin sections are built into the inner chamber (3) and result in a turbulent gas flow with minimum flow resistance. The gas flows straight through without changing direction and without oil pockets. Refrigerant liquid flows in the opposite direction to the gas, through the small outer chamber (4). The flow is guided by a built-in wire coil so that maximum heat transfer is achieved. The hot liquid flowing through the outer chamber normally protects the outer tube from sweating. Dimensions [mm] and weights [kg] Type H L L L 2 ød Net weight Outer chamber [cm 3 ] Volume Inner chamber [cm 3 ] HE 0.5 20 78 0 7 27.5 0.3 8.5 23.0 HE.0 25 268 2 9 30.2 0.5 25.0 45.0 HE.5 30 323 4 0 36.2.0 40.0 00.0 HE 4.0 38 373 20 0 48.3.5 80.0 260.0 HE 8.0 48 407 29 0 60.3 2.3 75.0 475.0 DKRCC.PD.FD0.A8.02 / 520H8754 5