Tube-in-tube heat exchanger Type HE

Similar documents
Tube-in-tube heat exchanger Type HE

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Check valve Types NRV and NRVH

Pressure Enthalpy Charts

General information on refrigerant controllers

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

CONDOR-H (horizontal) / CONDOR-V (vertical)

Liquid Distributor Type RD

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

OIL SEPARATORS APPLICATIONS

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

Bulletin , March Electric Hot Gas Bypass Valves

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

CHECK VALVES INSTALLATION

Danfoss Scroll for Refrigeration MLM / MLZ

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Pressure switch KPU. Data sheet

Product Catalog VALVES

Thermostatic Expansion Valves Type TR 6

Thermostatic expansion valves for ammonia Type TEA

Suction Line Accumulators

Filter Driers with Replaceable Core

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

S-Therm Air to Water Heat Pumps

Advance Split

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

Suction Accumulators. Introduction. Suction Accumulators

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Otherwise, you can continue reading the file on the following pages.

PPL Electric Utilities Energy Efficiency and Conservation Program

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Checking the Charge on a Heat Pump in the Winter

Energy Use in Refrigeration Systems

AIR CONDITIONER PERFORMANCE RATING

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

High temperature air-to-water heat pumps

The Saturation process

LAB EQUIPMENT DETAILS

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Compendium DES July 2016, CARN

of the liquid prior to it entering the expansion device. By doing so, the capacity for

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Test Report No.: Page 2 of 14

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

AIR COOLED CONDENSING UNIT

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

PWM expansion valves 2028

Refrigeration Systems

AE October 1965 Reformatted October Hot Gas Bypass Control Systems

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

DANFOSS OPTYMA PLUS INVERTER UNITS

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

HERO SERIES-DC INVERTER HEAT PUMPS

HVAC Fundamentals & Refrigeration Cycle

PattonPak Stream Condensing Units

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Thermostat KPU. Data sheet

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

RAC. Unit 1. Previous year Questions

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Technical Information

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

Head Pressure Control Valves

Installation, Start-Up and Service Instructions

Process glycol chillers

Introduction to Heat Exchangers

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

AIR COOLED CONDENSING UNITS

Transcription:

Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration plant. The purpose is to utilise the cooling effect, utilise which without a heat exchanger is otherwise lost to the ambient air via uninsulated suction lines. In the heat exchanger, this effect is used to subcool the refrigerant liquid. Features y High refrigeration capacity in evaporator y Helps ensure vapour-free liquid ahead of the expansion valve y HE 0.5-.5: May be used in the following EX range: Category 3 (Zone 2) y Maximum utilisation of the evaporator upon setting the thermostatic expansion valve for minimum superheat y Helps prevent sweating and frosted-up suction lines Approval GOST AN30 DCS (az) 208.03 DKRCC.PD.FD0.A9.02

Technical data R22, R270*, R34a, R290*, R404A, R407A, R407C, Refrigerants R407F, R448A, R449A, R450A, R452A, R507A, R53A, R600*, R600a* *) HE 0.5 -.5 only Operating temperature -60 20 C Max. working pressure HE 0.5, HE.0, HE.5, HE 4.0: PS / MWP = 28 bar HE 8.0: PS / MWP = 2.5 bar Max. test pressure HE 0.5, HE.0, HE.5, HE 4.0: Pe = 40 bar HE 8.0: Pe = 28 bar This product (HE 0.5 -.5) is evaluated for R290, R600, R600a and R270 by ignition source assessment in accordance with standard EN3463-. For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part of technical data. Ordering Type HE 0.5 HE.0 HE.5 HE 4.0 HE 8.0 Solder connection ODF Liquid line Suction line Code no. [in.] [mm] [in.] [mm] 6 2 05D000 / 4 / 2 05D0002 0 6 05D0003 3 / 8 5 / 8 05D0004 2 8 05D0005 / 2 3 / 4 05D0006 2 28 05D0007 / 2 / 8 05D0008 6 42 05D0009 5 / 8 5 / 8 05D000 Generally, the size of an HE heat exchanger can be determined from the connections corresponding to the pipe dimensions of the refrigeration plant. The design is such that normal suction gas velocities are achieved, with a subsequent small pressure drop. Thus the heat exchanger capacity will match plant capacity. At the same time, oil return to the compressor is ensured. If the main object is to avoid sweating and frosting-up of the suction line, the HE can be chosen one size larger than the size determined by the capacity. An HE used as an auxiliary condenser must always be selected according to the connection dimensions. DCS (az) 208.03 DKRCC.PD.FD0.A9.02 2

Capacity R22 R34a 5D5. 5D50. [te] t e t [te] e R404A 5D52. [te] t e DCS (az) 208.03 DKRCC.PD.FD0.A9.02 3

Capacity (continued) Precise heat exchanger sizing can be obtained from the curves which show plant capacity Q e for R22, R34a and R404A depending on evaporating temperature t e. Example Plant capacity Q e = 4.5 kw Refrigerant = R22 Evaporating temperature t e = -25 C The curve for R22 shows that an HE 4.0 is suitable. The curve for HE 4.0 lies immediately above the intersection of the lines through Q e = 4.5 kw and t e = -25 C. Heat flow Q during heat exchange is calculated from the formula: Q=k A t m Q heat flow in [W] k heat transfer coefficient in [W/m 2 ] A transfer area of the heat exchanger in [m 2 ] t m average temperature difference in, calculated from the formula: t m = ln t max. - t min. t max. t min. k A values Determined by experiment (see table). K A Type Dry suction gas / refrigerant liquid ) (normal use in refrigeration plants with fluorinated refrigerants) [W] / HE 0.5 2.3 HE.0 3. HE.5 4.9 HE 4.0.0 HE 8.0 23.0 ) These figures apply to dry gas only. Even if a thermostatic expansion valve is used, the suction gas will carry very small liquid drops into the suction line. The fins of the HE catch these drops which then evaporate. This may result in a smaller superheat than the theoretically calculated value. DCS (az) 208.03 DKRCC.PD.FD0.A9.02 4

Design / Function 6D36.4. Suction line connection 2. Liquid line connection 3. Inner chamber 4. Outer chamber Offset fin sections are built into the inner chamber (3) and result in a turbulent gas flow with minimum flow resistance. The gas flows straight through without changing direction and without oil pockets. Refrigerant liquid flows in the opposite direction to the gas, through the small outer chamber (4). The flow is guided by a built-in wire coil so that maximum heat transfer is achieved. The hot liquid flowing through the outer chamber normally protects the outer tube from sweating. Dimensions [mm] and weights [kg] Type H L L L 2 ød Net weight Outer chamber Volume Inner chamber [cm 3 ] [cm 3 ] HE 0.5 20 78 0 7 27.5 0.3 8.5 23.0 HE.0 25 268 2 9 30.2 0.5 25.0 45.0 HE.5 30 323 4 0 36.2.0 40.0 00.0 HE 4.0 38 373 20 0 48.3.5 80.0 260.0 HE 8.0 48 407 29 0 60.3 2.3 75.0 475.0 DCS (az) 208.03 DKRCC.PD.FD0.A9.02 5