ACCUMULATION OF EUROPEAN CLASS

Similar documents
Ideasandformsinevolution

The mechatronics of EVE 05

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Flue gas condensation...

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

STILE BEAUTY AND TECHNOLOGY

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

THE PERFECT CONDENSATION

C Tahiti. condensing

AIREX 2S WOOD PYROLYSIS SUCKING FAN

white blue cobalt bordeaux light oak (rovere)

SPECIFICATIONS - NIKE

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Condensing, pre-mixed, wall-hung gas boilers with water tank

ENERGY TOP. Condensing boiler solutions

Ciao Green Condensing Wall-Hung Boilers

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Capri B Cast iron combination oil-fired boiler with water tank

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

CITY OPEN - CITY BOX from 25 to 35 kw

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

WHE 2.24 / WHE 2.24 FF

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

UP TO 35 kw HE Collection

1 VICTRIX ZEUS Superior kw I features

The guarantee on this appliance is valid for 12 months from the first day of installation.

DOMESTIC HOT WATER Follow operational sequence

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Mynute Green Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers

Power X High Power Condensing Wall-Hung Boilers

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTALLATION AND OPERATION MANUAL

The iqe Boiler Range. Combination and System T Boilers.

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

GAS ABSORPTION HEAT PUMP

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSIONS: CODICE: AST 14C157/00. Wall-hung boilers

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

thea 35 MR/MN Kondens Wall-mounted condensing boiler

THE PERFECT CONDENSATION

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

RIELLO 40 GS/M SERIES

USERS MANUAL FOR GAS BOILERS

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

TAHITI CONDENSING KR 55 - KR 85

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSION: PART NO.: AST 14 C 256/00. Wall-hung atmospheric boilers

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

CONTENTS PRODUCT GAS TYPE CONVERSION ADJUSTMENTS FAULT & FAILURE. Product Notation Safety Systems Technical Data Main Components Operating Functions

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

MINORCA KC - KR - KRB 24

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

PCH/new Series. High performance, total flexibility

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Installation & Maintenance Manual

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSIONS: PART NO.: AST 14 C 261/00. Wall-hung atmospheric boilers. Instantaneous type with Forced Draught

Exclusive Green E Condensing Wall-Hung Boilers

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Quickheat 30 weather compensated boiler control

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Wall hung combination

.it AQ USER OPERATING INSTRUCTIONS

prestige Control Application Supplement - Type 5 MCBA WARNING

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

BOSCH CONDENS 5000W ZSB18-2A

WOLF GAS CONDENSING BOILERS COMFORTLINE

TAHITI DUAL HC - HR INSTALLATION, USE AND MAINTENANCE. Italian product. High quality

THERMAL RADIATORS STORAGE HEATERS PANEL HEATERS TOWEL RAILS CENTRAL HEATING BOILERS.

Floor standing boilers. RMG Mk.II RS Mk.II

ELECTRIC BOILERS. RANGE 1kW to 980kW ABOUT ATLANTIC ELECTRIC DOMESTIC HOT WATER HEATERS. WATER HEATERS 445 to 7520ltrs/hr

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

Transcription:

ACCUMULATION OF EUROPEAN CLASS

Total comfort MODEL nominal output kw minimum output kw DUA PLUS B TN DUA PLUS B TFS natural draught room sealed forced draught 28 12.4 28 12.4 DUA PLUS B was born from the optimization of the accumulation design, which conjugates the maximum of the performances obtainable from a 60 liter D.H.W. storage tank with a fluid and strong drawing, designed to become instantaneous, without solution of continuity, thanks to the 28 kw completely exchanged in this refined wall hung boiler. The user will appreciate mainly: the quickness in the temperature recovering time of the storage tank, so that more warm water can be used; the quickness, for the heating system, in reaching the steady state conditions, thanks to the use of a new microprocessor which allows the optimization of the boiler operation in both systems, with modulating or On/Off control. Furthermore, special attention has been paid to the reduction of the noisy emissions for the completion of the comfort reachable with the DUA PLUS B.

The mechatronics of DUA PLUS B High efficiency copper mono-thermal heat exchanger with cylindrical pipes and silicon coating Ultra-silent stainless steel burner with 15 ramps Ultra-fast 60 liter storage tank, enameled according to DIN 4753, with closed cells PU insulation. Double safety with two ignition electrodes IMPULSE The pump is automatically activated for 5 seconds by the electronic card in order to avoid jammings. 0 h 16 h 32 h 48 h TIME (hours) Two specific circulating pumps with built-in air venter, for C.H. and storage tank loading Timer for pump anti-jam function Manual reset of non-return valves, without removing the valve Inspection flange for storage tank cleaning, with magnesium anode Independent NTC sensors, for C.H. and D.H.W. Automatic differential by-pass for a perfect calibration of the C.H. system flow rate Simple use of the boiler controls on the swinging panel board, with diagnostics by LED Anti-frost protection

The well-being controls Easy to use DUA PLUS B is designed to guarantee the maximum ease to the user. The panel board has been studied according to the most recent fundamental ergonomic rules: the selector switch of the primary functions is placed in the center, with, all around, the secondary controls. A series of led indicate the functions ON, show the temperatures of heating and domestic hot water and the type of fault which could have occurred within the boiler. Double scale thermometer Through this thermometer it is possible to read: - the C.H. flow temperature on the L.H. side scale; - the D.H.W. temperature on the R.H. side scale. Reset button Button resetting the boiler operation after a lock-out of the burner control. Lockout warning lamp Indicates the lock-out of the burner control. Fault signaling lamp Indicates a fault in the boiler operation. Burner On Lamp Indicates the good operation of the burner. Supply line On Lamp Indicates the power supply is On. Outer sensor calibration button Adjust the compensation curve for the control of the room temperature depending on the outer temperature (it works only when the outer temperature sensor is fitted). Heating only position Off/anti-frost position Summer position Winter position Multifunction switch the boiler works for C.H. only. the boiler is Off; only anti-frost protection is On. he boiler works for D.H.W. production only. the boiler works for heating and D.H.W. production. Signaling lamp The lamp is on when s.f.b. is selected. Special functions button Re-activates the boiler after certain technical services. Heating temperature adjustement This knob allows the adjustement of the C.H. flow temperature. Adjustement range: 35 to 85 C. D.H.W. temperature adjustement This knob allows the adjustement of the D.H.W. temperature. Adjustement range: 35 to 65 C.

From the power the best solutions DUA PLUS B 28 modulating kw The ultra-fast D.H.W. tank of DUA PLUS B has: Storage capacity of 60 liters Production of 200 liters of hot water at 45 C in 10 min, with an inlet temperature of 15 C Recovering time of 5.5 min (60 liters at 45 C) From 15 to 65 C in 8 min Output exchanged: 28 kw Exchange surface: 0.8 m 2 Length of the coil: 10.4 m Insulation thickness: 30 mm The storage tank is manufactured with an innovative glass lining system, with electrostatic powder deposit. It offers considerable advantages: Increase in the corrosion resistance, thanks to the pre-treatment of the whole steel surface to be enameled, with a pneumatic sand blasting, made with steel shots which removes all the machining residues and eliminates all eventual welding seams imperfections. Higher resistance to the scaling deposits, thanks to the glossy inner surfaces of the tank, which impede the grappling of the small scaling particles. High increase of the shock resistance, thanks to the elasticity of the lining. Special attention is paid to the insulation, made of two shells of PU foam, CFC free. 10 Detail of the D.H.W. storage tank D.H.W. PRODUCTION TIME Recovering time from 15 to 65 C in 8 min only. Continuous D.H.W. production: 15 l/min at 45 C. 200 liters in10 min! (with t 25 K at 45 C)

To heat and economize HEATING NTC TEMPERATURE ON OFF A BAND ANTIFAST 3 minutes DUA PLUS B is a wall hung boiler designed to speedily and silently heat medium and large size houses. ANTI-FAST DIAGRAM PRE-SET TEMPERATURE BOILER RE-STARTING TEMPERATURE B BAND ANTIFAST < 3 minutes BOILER TIME t 15 C The 28 kw, to avoid energy waste, are controlled by a microprocessor which modulates the output from 12.5 to 28 kw through the heating NTC temperature sensor. Its ANTI-FAST system reduces the On and Off cycles, responsible for the high consumptions. The ANTI-FAST system is an electronic ignition delaying device which acts after the switch Off of the burner, due to the temperature attainment (the pre-set temperature). If the room thermostat stays on demand, the boiler is switched On after about three minutes (A BAND), time which is reduced to zero if the boiler temperature goes down quickly of 15 C against the pre-set temperature (B BAND). Advantages: The quickness, for the heating system, in reaching the steady state conditions. On-Off cycles reductions, with consequent consumption reduction and components wear. AVAILABLE AS ACCESSORY Code No. 00261950 The TM 2000 clever comfort TM 2000 is a compensator which optimizes, automatically all the parameters, by modulation of: the output the central heating temperature the ignition delaying device ANTI-FAST up to 10 min interval, if necessary. So, it is possible to install DUA PLUS B boilers in installations which demand for a small heating output, thus avoiding high fuel waste and having, in the mean time, the advantage of the large availability of D.H.W., specific of the DUA PLUS B. The functions of TM 2000 are: Control of the requested room temperature Two changeable heating programs On/off times Continuous adjustments Economic reduction Visualization and modification of the operation and safety parameters of the boiler Anti-frost protection

Accessories and mounting jig KIT A KIT B Thanks to the mounting jig supplied with the boiler, to the flue duct kits and to a series of chrono-thermostat, DUA PLUS B offers excellent solutions for each installation. AIR/SMOKE COAXIAL DUCTS Code No. KIT5500C AIR/SMOKE SEPARATE DUCTS Code No. 00360535 R - C.H. return 3/4" G - Gas 3/4" M - C.H. flow 3/4" C - Hot water outlet 1/2" F - Cold water inlet 1/2" OUTER TEMPERATURE SENSOR DIGITAL WEEKLY CHRONO-THERMOSTAT ELECTRONIC ANALOGUE DAILY CHRONO- METAL MOUNTING JIG Code No. SND 0140C SD 700 Code No. 00260738 THERMOSTAT Code No. 00260737 Code No. 00211079 Technical data Model NOMINAL AND MINIMUM OUTPUT NOMINAL INPUT WATER EFFICIENCY AT 100 LOAD WATER EFFICIENCY AT 30 LOAD COMBUSTION EFFICIENCY AT 100 LOAD HEAT LOSSES THROUGH THE CASING MIN/MAX MAX SMOKE TEMPERATURE SMOKE FLOW RATE MIN/MAX CO 2 CHIMNEY HEAT LOSSES WITH BURNER IN OPERATION MIN/MAX CHIMNEY HEAT LOSSES WITH BURNER OFF MIN/MAX APPLIANCE CATEGORY MIN WATER THROUGHPUT IN THE C.H. CIRCUIT WITH t = 20K C.H. CIRCUIT MIN/MAX WORKING PRESSURE PRIMARY CIRCUIT WATER CONTENT D.H.W. MIN/MAX WORKING PRESSURE D.H.W. TANK/CLOSED EXPANSION VESSEL CAPACITY C.H. CIRCUIT MAX WATER CONTENT * D.H.W. FLOW ADJUSTER CONTINUOUS D.H.W. PRODUCTION ** AVAILABILITY OF D.H.W. ELECTRICAL SUPPLY TENSION/FREQUENCY MAIN FUSE MAXIMUM OUTPUT ABSORBED DEGREE OF PROTECTION NET WEIGHT OPTIONAL: D.H.W. CIRCUIT SUPPLEMENTARY EXPANSION VESSEL Code No. 00360636 kw kw C g/s l/min bar l bar l l l/min l/min l V-Hz A(F) W IP kg DUA PLUS BTN 28 27,9 / 12,5 31 89,95 / 89,89 89,21 / 87,34 92,2 / 88,6 2,47 / 2,25 68,9 / 87,5 22,8 / 25,6 2,35 / 4,6 11,4 / 7,8 0,449 II2H3+ 8,9 0,5 / 3 3,25 0,5 / 6 60 / 7,5 139,9 12 15,99 175 230/50 4 89 X4D 82 DUA PLUS BTFS 28 28,2 / 12,4 31 90,97 / 89,9 88,21 / 87,35 91,9 / 85,8 0,23 / 0,93 98,5 / 116,9 18,7 / 18,8 2,7 / 6,2 14,2 / 8,1 0,489 II2H3+ 8,8 0,5 / 3 3,25 0,5 / 6 60 / 7,5 139,3 12 16,17 175 230/50 4 148,5 X4D 89 Manometric Head H (m) 870 600 485 DIAGRAM FLOW RATE/MANOMETRIC HEAD 6 5 4 3 2 1 0 V1 V2 100 300 500 700 900 1100 1300 Flow rate (Q) l/h (*) Calculated for a maximum temperature of 90 C (**) Medium flow rate for a t = 25 K V3

AG S.p.A. 46033 casteldario - mantova - italy -tel. 0376/57001 (r.a.) - telefax 0376. 660556 - e-mail: info@unical-ag.com Unical AG declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves the right to introduce those modifications to its products that it considers necessary or useful, without compromising the essential characteristics of the said products.