SYSTEM. field cuttable. lipleds 8200 Series

Similar documents
SYSTEM. field cuttable LLED8000

SYSTEM FIELD CUTTABLE SERIES

SERIES. LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED

EFFICIENT LONG LIFE & ENERGY SERIES

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

OPTIONS. Mounting LUMEN OUTPUT FLAT. 3000K lm/ft PERFORMANCE. Lumen Maintenance SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

OPTIONS. Mounting LUMEN OUTPUT. Flat. Round PERFORMANCE. Color Temperature. Lumen Maintenance Binning Tolerance Warranty + +

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Ivalo Lumaris LED Linear Lighting

ACCESSORIES. Mounting LUMEN OUTPUT 2400K 1 PERFORMANCE. Lumen Maintenance. Warranty SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

Fino Healthcare. Asymmetric Wall Mount Indirect LED

EcoSystem H-Series 347 V~ Ballast Overview

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

EcoSystem H-Series Ballasts

FLEX DC SIDE EMITTING

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Performance Chart Electrical Data

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

LIGHT CHANNEL TRIM 1.6

Performance Chart Electrical Data

M60 LED Recessed Wet Location

SECTION INTERIOR LIGHTING

Ivalo Lumaris LED Linear Lighting

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Grüv Flare Regressed. Recessed Linear LED

Hornet HP. Round Glass Downlight

Recessed LED Wall/Slot SAE 202

Ivalo Lumaris LED Linear Lighting

Grüv Flare Regressed. Recessed Linear LED

Fino. Asymmetric Wall Mount Indirect LED

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Classix 6" 6" Round Lens Wall Wash

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

Performance Chart Electrical Data

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Fino Healthcare. Asymmetric Wall Mount Indirect LED

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

Dimensions (111mm) (111mm) 3 (76mm)

LED Linear Design Highlights

Classix 6" 6" Round Adjustable C3M

Linea 1.5. Linear Direct Wall Wash LED

Product Specifications MaxLumen MRI LED Diffused Lighting

Evoke Square Downlight

LUXCOMFO TM LED Flood Light Datasheet

Product Specifications MaxLumen MRI LED Diffused Lighting

Hornet HP. Square Glass Downlight

Classix 6" 6" Round Adjustable C3

PRODUCT CODE DRIVER FACEPLATE FINISH WATTAGE COLOR TEMP VOLTAGE

NOVA CEILING WALL GRAZER WITH REMOTE POWER

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

VESICA LINEAR SUSPENDED VES L

Evoke Square Downlight

LIGHT CHANNEL 45 COMPLETE FIXTURE

12 inches to 120 inches

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

PRODUCT CODE DRIVER FACEPLATE FINISH WATTAGE COLOR TEMP VOLTAGE

Performance Chart Electrical Data

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

3.75 Gyro Shift Multiples Single Head

CRENSHAW. LED Lamping Guide. Crenshaw LED. Farrell Hall, Wake Forest University

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Performance Chart Electrical Data

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Classix 6" 6" Round Adjustable C3

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

LED ROUND MINI PANELS

Essenza. Round Downlights

Product Specifications MaxLumen MRI LED Diffused Lighting

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

EcoSystem H-Series Ballasts Overview

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Square Downlight

Catalog Number. Notes

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

M100 LED Direct/Indirect

Evoke Round Adjustable C3

Classix 6" 6" Round Lens Wall Wash

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

S R 8 Circular LED Engine Product Specification

Classix 6" 6" Round Lens Wall Wash

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

DHL-LP-LED Low Profile LED Linear High/Low Bay

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Evoke 2.9" HP. 2.9" Square Downlight

Transcription:

lipleds 8200 Series Replaceable LED Boards 24V CRI > 90 field cuttable SYSTEM DIMMING Forward Phase (TRA) 0-10V (TRA-E) Hi-Lume 1% A Series (2 Wire) Hi-Lume 1% (3 Wire) Title 24 JA8 (JA8) EFFICACY 108 Lumens Per Watt L70 LED LIFE 60,000 hrs. DRY OR WET (IP65 or IP67) LOCATION UL2108, CSA C22.2#9 UL8750, CSA250 lipleds TM Series is a field cuttable system designed with long life, energy efficient LEDs that result in low maintenance installations. lipleds TM is excellent to illuminate areas for cove lighting, accent lighting, backlighting, and other indirect lighting applications. MADE IN USA 10-DAY Lighting for the Professional Designer

Applications VOLTAGE Lamp Type Accent, Decorative Lighting 24VDC Modular LEDs lipleds 8200 SERIES FEATURES lipleds 8200 series is a 24 volt system that requires a 24VDC (secondary side) transformer. The standard primary side voltage on our transformers is 120V or 277V. Consult factory for other primary side voltages. See transformer brochure for additional information. DIMMING Length CONSTRUCTION MOUNTING CRI > 90 efficacy VIEWING ANGLE Forward Phase (TRA) 0-10V (TRA-E) Hi-Lume 1% A Series (2 Wire) Hi-Lume 1% (3 Wire) Title 24 JA8 (JA8) Built to Order LED Modules (Field Cuttable - Dry Location Only) Mounting Clips or Mounting Channel 108 Lumens per Watt 120 Degrees L70 LED LIFE MAXIMUM RUN *1 (5 Amps) LISTING 60,000 hrs. 20' (6W) 30 (4W) 36 (2W) Dry or Wet (IP65 or IP67) Location UL2108, CSA C22.2#9 UL8750, CSA250 2 lipleds LLED8200 California Accent Lighting, Inc. 800.921.CALI

PERFORMANCE Color Vector Graphic TM-30 METRIC RESULT NOTES R f 92 IES TM-30-15 Fidelity Index Rg 101 IES TM-30-15 Gamut Index CIE R a 96 CIE Test Color Method General Index R 9 72 CIE Test Color Method Sample Nine Score R f, skin 95 Average of CES15 and CES18 (skin) CCT 3423 Correlated Color Temperature D uv -0.0004 Distance from blackbody locus Reference Illuminant x 0.4093 CIE 1931 chromaticity coordinate y 0.3917 CIE 1931 chromaticity coordinate Polar Graph u 0.2379 CIE 1960 chromaticity coordinate v 0.3415 CIE 1960 chromaticity coordinate 158 u 0.2379 CIE 1976 chromaticity coordinate v 0.5123 CIE 1976 chromaticity coordinate 118 79 2 39 1 Maximum Candela = 157.96 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0-180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.) Chromaticity Diagram Y 0.9 LAMP NUMBER Description 0.8 0.7 510 520 530 540 550 LED-2.4K 2400K Incandescent White 0.6 560 LED-2.7K 2700K Warm White 0.5 0.4 0.3 0.2 500 490 570 580 0.4093, 0.3917 590 600 610 620 630 640 650 700 LED-3.0K LED-3.5K 3000K Warm White 3500K Neutral White 0.1 0 0 480 470 460 440 430 380 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X LED-4.0K LED-4.5K 4000K Neutral White 4500K Cool White calilighting.com California Accent Lighting, Inc. lipleds LLED8200 3

Lens and SINGLE Light Strip 2W 4W 6W.33.42.20.18 LLED8200 lightstrip is field-cuttable every 6 for easy installation without rigorous requirements. Clear Lens (CL) 50% Semi-Frosted Lens (SF) Frosted Lens (F) Dry Location 2W, 4W.33.20 Wet (IP67) Location 2W, 4W.36.52 6W.42 6W 8' maximum extrusion and lens length (Dry location field cuttable).18.75.78 2W (Max 36'), 4W (Max 30').33 6W (Max 20').42 How to Order or Specify Series OPTICS Watts per Foot LLED8200* 6 LLED8200-RPM Clear Lens 2 Watts (2W) Forward Phase LED-2.4K LLED8200-CM* 6 LLED8200-SR* 7 (CL)* 8 (216 Lumens/ft) (DM) LED-2.7K LLED8200-CMC LLED8200-ST 50% Semi-Frosted Lens 4 Watts (4W) 0-10V LED-3.0K LLED8200-CR LLED8200-UC* 6 (SF) (432 Lumens/ft) (10V) LED-3.5K DIMMING LAMP dry OR wet FINISH (CHANNELS) Indoor (DRY) Outdoor IP65 (WET)* 6 LLED8200-HC LLED8200-UCS* 7 LED-4.0K 100% Frosted Lens 6 Watts (6W) Hi-Lume 1% A Outdoor (F) (648 Lumens/ft) (2 Wire)* IP67 LLED8200-L* 3 8 LLED8200-WMC LED-4.5K (WET)* 6 LLED8200-LPG LLED8200-LR LLED8200-OL LLED8200-RC LLED8200-WMR Hi-Lume 1% (3 Wire)* 4 Title 24 JA8 (JA8) Natural Silver (NA)* 2 Polished (PA) White (WH) Satin (SA) Black (BK) Green (GN) Red (RD) Silver (SR) Custom Powder Coat (PC) LLED8200-RCR LLED8200-RME Leave Blank for Non-Dimming EXAMPLE: LLED8200-CL-2W-DM-LED-3.0K-DRY-NA *1 Maximum run based on 5 amps for class II applications: 14 (6W), 24 (4W), 36 (2W) *2 Standard finish - Natural Silver if left blank (Finish does not apply to LLED8200, LLED8200-ST, or LLED8200-ST-F) *3 40 watt max Hi-Lume Lutron 1% A #LTEA4U1UKL-CV240 *4 40 watt max Hi-Lume Lutron 1% #L3DA4U1UKL-CV240 *5 Run lengths required for Wet Location products (To ensure proper seal) *6 No optics available *7 Add.23" to overall height for optics *8 Standard lens 120 - Clear if left blank 4 lipleds LLED8200 California Accent Lighting, Inc. 800.921.CALI

SURFACE MOUNT ±.015" Tolerance LLED8200 (2W) LLED8200 (4W) LLED8200 (6W).33.33.42.20.20.18 LLED8200-UC LLED8200-ST LLED8200-ST 2W, 4W 6W.35.36.78 No Lens.44.52.75 LLED8200-WMC.73 LLED8200-L 15, 30, 45, 60 LLED8200-SR 15, 30, 45, 60.79 1.62.64.79 RECESS MOUNT LLED8200-UCS 15, 30, 45, 60 1.0 LLED8200-CR.96 LLED8200-LPG.97.59.26.79 Walk Over.90 LLED8200-RME LLED8200-LR LLED8200-WMR.82.70.60.94 1.75.79 2.36 2.86 1.38.74 LLED8200-RCR 1.13 1.25 1.51 CORNER MOUNT LLED8200-CM LLED8200-CMC.71.71 PENDANT MOUNT LLED8200-HC LLED8200-RPM LLED8200-OL.92.92 1.46 2.34 Closet Rod.94 1.20 LLED8200-RC 1.13 1.25 calilighting.com California Accent Lighting, Inc. lipleds LLED8200 5

LLED8200.44 2W 4W 6W.75.42.33.35.35.26 1.0 1.0.44.18.20 MOUNTING CLIP (DRY) #LLED8200-MC MOUNTING CLIP (DRY) #LLED8200-UC.78 1.42 MOUNTING CLIP (WET) #LLED8200-MC-WET MOUNTING CLIP (WET) #LLED8200-MC-WET-6W LLED8200-UC.56.35 0.94.44 No Lens 0.55 LLED8200-SR 0.84 0.82 0.79 0.56.64 0.94.79 Specify Length X X = Custom Length LLED8200-L 0.94.79 1.75 0.93 0.55 0.36 0.90 0.84 #LLED8200-XX-MC #LLED8200-XX-MC-1 0.70 0.55 1 #LLED8200-XX-MC-2 0.90 #LLED8200-XX-MC-3 (Adjustable) #LLED8200-XX-MC-4-X (Specify Length Maximum 2').73 LLED8200-WMC LLED8200-ST LLED8200-ST 6W 2W, 4W 1.62.75.36 #LLED8200-XXXX-MC 8.78 1.42.78.52.75 #LLED8200-ST-uc #LLED8200-ST-MC-1 (Mounting Channel) RECESS MOUNT Mounting Options LLED8200-UCS LLED8200-CR LLED8200-LPG 1.0.59.97.79.90 Embedded Channel LLED8200-RME LLED8200-WMR.70 Glass (thickness 3/16" ~ 1/4").96 Concrete or Wood Floor.26 Glass Mount.82.60 1 2.36 2.86.75 1.38 Dropped Ceiling Toe Kick Recessed Channel LLED8200-LR 1.19 #LLED8200-SPR-MC.25.29 LLED8200-RCR 1.13.29 4.00.55 1.25 1.51 6 lipleds LLED8200 1.0 #LLED8200-RCR-MC #LLED8200-RCR-MC-H California Accent Lighting, Inc. 800.921.CALI ACCESSORIES SURFACE MOUNT Mounting Options

CORNER MOUNT Mounting Options LLED8200-CM.61 1.05 1.0.61 1.78 1.05 Specify Length X X = Custom Length ACCESSORIES.69 #LLED8200-CM-MC-1.90 #LLED8200-CM-MC-2 1 #LLED8200-CM-MC-3 (Adjustable).90 #LLED8200-CM-MC-4-X (Specify Length Maximum 2').98 LLED8200-CMC.56 Specify Length X=Length.71 1.41 1.52 1.41.98.71.96.96 #LLED8200-CMC-MC-1 #LLED8200-CMC-MC-2 1 #LLED8200-CMC-MC-3 (Adjustable).96 #LLED8200-CMC-MC-4-X (Specify Length Maximum 2') PENDANT MOUNT Mounting Options.25 LLED8200-HC LLED8200-OL.92 1.46 4.00.55 2.34 1.20 #LLED8200-XX-MC-H LLED8200-RPM 1.92 3.00 Closet Rod.94.55 mounting Bracket #LLED8200-MB LLED8200-RC 1.13.29.25.29 1.2 4.00.55 1.0 #LLED8200-RC-MC #LLED8200-RC-MC-H POWER CONNECTORS - SINGLE ROW CONTINUOUS CONNECTORS - SINGLE ROW 33 1.5.67.07.56.33.43 Power Connector (#LLED8200-PC) 3 Continuous Connector (#LLED8200-CC) 33 1.5 Power Connector White Jacket (#LLED8200-PC-w) Continuous Connector White Jacket (#LLED8200-CC-W) 33 1.5 Power Connector Black Jacket (#LLED8200-PC-B) calilighting.com California Accent Lighting, Inc. Continuous Connector Black Jacket (#LLED8200-CC-B) lipleds LLED8200 7

transformer Electronic: 0-10V Dimming Transformer (Indoor or Outdoor Rated) Product Code Max. Watts Input Output Input AC Current Power Factor Width (W) Height (H) Depth (D) TRA16-E TRA16-E-UNV-24VDC-10V 16 120V-277V 24VDC.2A / 277VAC or.4a / 120VAC.92 12.7 3.43 2.66 TRA25-E TRA25-E-UNV-24VDC-10V 25 120V-277V 24VDC.2A / 277VAC or.4a / 120VAC.92 12.7 3.43 2.66 TRA40-E TRA40-E-UNV-24VDC-10V 40 120V-277V 24VDC.25A / 277VAC or.6a / 120VAC.92 12.7 3.43 2.66 TRA60-E TRA60-E-UNV-24VDC-10V 60 120V-277V 24VDC.3A / 277VAC or.64a / 120VAC.92 12.7 3.43 2.66 TRA80-E TRA80-E-UNV-24VDC-10V 80 120V-277V 24VDC.4A / 277VAC or.85a / 120VAC.94 12.7 3.43 2.66 TRA90-E TRA90-E-UNV-24VDC-10V 90 120V-277V 24VDC.4A / 277VA or.85a / 120VAC.95 12.7 3.43 2.66 TRA100-E TRA100-E-UNV-24VDC-10V 100 120V-277V 24VDC.5A / 277VAC or 1.2A / 120VAC.93 15.7 4.42 2.92 TRA120-E TRA120-E-UNV-24VDC-10V 120 120V-277V 24VDC.55A / 277VAC or 1.4A / 120VAC.93 15.7 4.42 2.92 TRA150-E TRA150-E-UNV-24VDC-10V 150 120V-277V 24VDC.7A / 277VAC or 1.7A / 120VAC.92 15.7 4.42 2.92 TRA185-E TRA185-E-UNV-24VDC-10V 185 120V-277V 24VDC.8A / 277VAC or 2.1A / 120VAC.92 15.7 4.42 2.92 TRA240-E TRA240-E-UNV-24VDC-10V 240 120V-277V 24VDC 2A / 277VAC or 4A / 120VAC.95 15.7 4.42 2.92 TRA320-E TRA320-E-UNV-24VDC-10V 320 120V-277V 24VDC 1.45A / 277VAC or 3.5A / 120VAC.94 15.7 4.42 2.92 ** Class II 24VDC TRA16-E, TRA25-E, TRA40-E, TRA60-E, TRA-80E, TRA90-E Dimming Protocol (0-10V) TRA-E Compatible Dimmers Technical Requirements For Control Equipment (0-10V Protocol) The output current level of the dimmable driver is controlled by DC voltage (0-10V) applied to the control terminals (blue and white). The light output of LEDs is controlled by the amount of output current from the dimmable driver. The control device must be capable of sinking a DC current flow from the driver. The maximum amount under any condition is 500 microamps (ua) per driver. The control terminals of the dimmable driver are isolated from the power lines and are suitable for use as Class 2 wiring. Multiple drivers are desired for use with same control device, the control terminals may be connected in parallel in a bus configuration. Since the control bus is Class 2 wiring, all control devices that are connected to the power line must have proper isolation between the power line and the control terminals/bus. The control device, which intends to control more than one dimmable driver, must be capable of sinking the total current supplied to control bus by the drivers. If the control terminals/bus is shorted in any case, the current on the control terminals/bus will be 500 microamps (ua) per driver maximum. If the control terminals are opened, the voltage on the control terminals will then be 10V ± 0.5 volt. As a result, dimmable driver supplies maximum output current to LEDs under this condition. The driver is intended for use with control voltages between 0 and 10 VDC. The control equipment must not impose a voltage greater than 11 V peak maximum on the driver control terminals. 120V-277V TRAXXX-E-UNV-24VDC-10V Brown (Hot) Blue (Neutral) Transformer enclosure Red (+) Black (-) TRAXXX-E-UNV-24VDC-10V 24VDC to Lighting White (-) Blue (+) Dimmer (Supplied by others) 0-10V Line 8 lipleds LLED8200 California Accent Lighting, Inc. 800.921.CALI

transformer Magnetic: Forward Phase Dimming Transformer (Indoor or Outdoor Rated NEMA 3R) - Primary Fusing Included Product Code Max. Watts Input Output Input Current No Load-Full Load Power Factor Width (W) Height (H) Depth (D) TRA5 TRA5-120V-24VDC 5 120V 24VDC.4-1.4 Amps 0.961 1.975 6 1.43 TRA5-277V-24VDC 5 277V 24VDC 0.2-0.6 Amps 0.961 1.975 6 1.43 TRA10 TRA10-120V-24VDC 10 120V 24VDC 0.3-2.2 Amps 0.964 1.975 6 1.43 TRA10-277V-24VDC 10 277V 24VDC 0.12-0.8 Amps 0.964 1.975 6 1.43 TRA20 TRA20-120V-24VDC 20 120V 24VDC 0.3-2.6 Amps 0.979 1.975 6 1.43 TRA20-277V-24VDC 20 277V 24VDC 0.12-1.2 Amps 0.979 1.975 6 1.43 TRA35 TRA35-120V-24VDC 35 120V 24VDC 0.4-4.3 Amps 0.973 1.975 6 1.43 TRA35-277V-24VDC 35 277V 24VDC 0.15-1.8 Amps 0.973 1.975 6 1.43 TRA40 TRA40-120V-24VDC 40 120V 24VDC 0.8-5.3 Amps 0.978 1.975 6 1.43 TRA40-277V-24VDC 40 277V 24VDC 0.3-2.3 Amps 0.978 1.975 6 1.43 TRA50 TRA50-120V-24VDC 50 120V 24VDC 0.8-5.3 Amps 0.978 1.975 6 1.43 TRA50-277V-24VDC 50 277V 24VDC 0.3-2.3 Amps 0.978 1.975 6 1.43 TRA60 TRA60-120V-24VDC 60 120V 24VDC.4-1.4 Amps 0.961 3.00 7 2.75 TRA60-277V-24VDC 60 277V 24VDC 0.2-0.6 Amps 0.961 3.00 7 2.75 TRA75 TRA75-120V-24VDC 75 120V 24VDC.4-1.4 Amps 0.961 3.00 7 2.75 TRA75-277V-24VDC 75 277V 24VDC 0.2-0.6 Amps 0.961 3.00 7 2.75 TRA90 TRA90-120V-24VDC 75 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA90-277V-24VDC 75 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA100 TRA100-120V-24VDC 100 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA100-277V-24VDC 100 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA150 TRA150-120V-24VDC 150 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA150-277V-24VDC 150 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA200 TRA200-120V-24VDC 200 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA200-277V-24VDC 200 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA250 TRA250-120V-24VDC 250 120V 24VDC 0.3-2.2 Amps 0.964 4.1875 8 3.25 TRA250-277V-24VDC 250 277V 24VDC 0.12-0.8 Amps 0.964 4.1875 8 3.25 TRA300 TRA300-120V-24VDC 300 120V 24VDC 0.3-2.6 Amps 0.979 4.1875 8 3.25 TRA300-277V-24VDC 300 277V 24VDC 0.12-1.2 Amps 0.979 4.1875 8 3.25 * Class II 24VDC TRA5, TRA10, TRA20, TRA35, TRA40, TRA50, TRA60, TRA75, TRA90 Dimming Protocol (Forward Phase Dimming) TRA Compatible Dimmers Technical Requirements For Control Equipment Magnetic Low Voltage (MLV) - Magnetic (core and coil, toroidal) transformer-supplied low voltage lighting Electrical Characteristics - Inductive Special Requirements - Symmetric cycles (VDC 2), smooth turn off (positive and negative periods are equal for safe MLV transformer operation) TRAXXX-120V-24VDC TRAXXX-277V-24VDC Transformer enclosure Transformer enclosure Red (+) Red (+) Blue (-) Green (Ground) Blue (-) Green (Ground) 24VDC to Lighting 24VDC to Lighting Optional Dimmer (not included) Optional Dimmer (not included) White (Neutral) White (Neutral) Black Dimmed (Hot) Orange (277V) Primary Voltage Line Primary Voltage 277VAC Line 120VAC calilighting.com California Accent Lighting, Inc. Forward Phase Dimming Forward Phase Dimming lipleds LLED8200 9

transformer Lutron: Hi-Lume A Series Lutron: Hi-Lume 1% Transformer (Indoor) Product Code Max. Watts Input Output Input Current No Load-Full Load Power Factor Width (W) Height (H) Depth (D) TRA40-E-1%-2 TRA40-E-UNV-24VDC-FP-1%-2WIRE 40 120V-277V 24VDC 0.37A / 120VAC or 0.17 / 277 VAC 0.9 4" 2.62" 4" TRA40-E-1%-3 TRA40-E-UNV-24VDC-FP-1%-3WIRE 40 120V-277V 24VDC 0.37A / 120VAC or 0.17 / 277 VAC 0.9 4" 2.62" 4" DIMMING PROTOCOL (2 Wire - 40 Watt Max Hi-Lume A Series Lutron #LTEA4U1UKL-CV240) Compatible with Energi Savr Node unit with EcoSystem, GRAFIK Eye QS control unit, PowPak dimming module with EcoSystem, and Quantum systems, allowing for integration into a planned or existing EcoSystem lighting control solution. Meets ANSI C62.41 category A surge protection standards up to and including 4 kv. FCC Part 15 compliant for commercial applications at 120 V~ or 277 V~ Dimming Range: 100% to 1%. Operating Voltage: 120 277 V~ at 50/60 Hz. Lifetime: 50,000 hours @: tc = 149 F (65 C)1 for 40 W drivers. For rated warranty, tc not to exceed the maximum rated temperatures listed here. Patented thermal foldback protection. LEDs turn on to any dimmed level without going to full brightness. Non-volatile memory restores all driver settings after power failure. Power Factor: > 0.90 for loads greater than 25 W Standby Power Consumption: < 1.0 W Total Harmonic Distortion (THD): < 20% for loads greater than 25 W. Inrush Current: < 2 A. Inrush Current Limiting Circuitry: eliminates circuit breaker tripping, switch arcing and relay failure. Open circuit protected. Short circuit protected. Turn-on time: 1.5 seconds.2 PWM Dimming Frequency: 550 Hz. DIMMING PROTOCOL (3 Wire - 40 Watt Max Hi-Lume 1% Lutron #L3DA4U1UKL-CV240 Compatible with Energi Savr Node unit with EcoSystem, GRAFIK Eye QS control unit, PowPak dimming module with EcoSystem, and Quantum systems, allowing for integration into a planned or existing EcoSystem lighting control solution. Meets ANSI C62.41 category A surge protection standards up to and including 4 kv. FCC Part 15 compliant for commercial applications at 120 V~ or 277 V~ Dimming Range: 100% to 1%. Operating Voltage: 120 277 V~ at 50/60 Hz. Lifetime: 50,000 hours @: tc = 149 F (65 C)1 for 40 W drivers. For rated warranty, tc not to exceed the maximum rated temperatures listed here. Patented thermal foldback protection. LEDs turn on to any dimmed level without going to full brightness. Non-volatile memory restores all driver settings after power failure. Power Factor: > 0.90 for loads greater than 25 W Standby Power Consumption: < 1.0 W Total Harmonic Distortion (THD): < 20% for loads greater than 25 W. Inrush Current: < 2 A. Case type KL Inrush Current Limiting Circuitry: eliminates circuit breaker tripping, switch arcing and relay failure. Open circuit protected. Short circuit protected. Turn-on time: 1.5 seconds.2 PWM Dimming Frequency: 550 Hz. 10 lipleds LLED8200 California Accent Lighting, Inc. 800.921.CALI

Design Guidelines Option A - Straight Runs Detail A Power Connector (#LLED8200-PC) 33" 1.5" Option B - Rectangular Runs Detail A Detail A Power Connector (#LLED8200-PC) 33" 1.5" 33" 1.5" Power Connector (#LLED8200-PC) 36" total length Detail B Detail B Continuous Connector (LLED8200-CC) 3" Continuous Connector (#LLED8200-CC) Option C - Runs with Custom Continuous Connector XX" Length Detail B Continuous Connector (#LLED8200-CC-XX) (XX - Specify Length) Option D - Curvable Runs Circular Runs Semi-Circular Runs Curved Runs 10" Minimum Radius 10" Minimum Radius calilighting.com California Accent Lighting, Inc. lipleds LLED8200 11

APPLICATIONS Accent Lighting LLED8200-UC LLED8200-CM LLED8200-L Cove Lighting Field Curveable Lighting LLED8200 LLED8200 LLED8200 LLED8200 Wall Grazing LLED8200-SR-30D LLED8200-SR-15D LLED8200-SR-45D LLED8200-SR-60D Mirror Lighting LLED8200-STF LLED8200-L-F LLED8200-SR-F LLED8200-OL-F Direct View Lighting Recessed to wall LLED8200-RCR-F Recess to Ceiling LLED8200-RCR-F Closet Mount LLED8200-RPM Pendant Mount LLED8200-RC-F 12 lipleds LLED8200 California Accent Lighting, Inc. 800.921.CALI

APPLICATIONS Accent Lighting Back Lighting LLED8200-UC LLED8200-UC LLED8200-UC Panel Lighting Side View Front View Cornice Lighting LLED8200-L Toe Kick Lighting LLED8200-ST-F Underbench Lighting LLED8200-SR Step Lighting LLED8200-ST-F Undercounter Lighting LLED8200-CMC-F LLED8200-SR-F LLED8200-CMC-F Bartop Lighting LLED8200-ST Back Bartop Lighting LLED8200-SR-F calilighting.com California Accent Lighting, Inc. lipleds LLED8200 13

Irvine Spectrum, Irvine, CA. Designed by LPA, Inc. California Accent Lighting, Inc. 2034 E. Lincoln Ave. #431, Anaheim, CA 92806 ph. 800.921.CALI or 714.535-7900 fx. 714.535.7902 info@calilighting.com calilighting.com CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice. MADE IN USA 14 lipleds LLED8200 California Accent Lighting, Inc. 800.921.CALI