Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Similar documents
INSTRUCTION MANUAL T-154. DOSSENA s.n.c. Via Federico Barbarossa s/n Cavenago di Adda tel Fax:

INSTRUCTION MANUAL T-935-FO ANALOGUE. TECSYSTEM S.r.l. TECSYSTEM S.r.l. protection relays. 12 protection relays

INSTRUCTION MANUAL T-935 FO DIGITAL

MO n : 12JMC rév A

CTT8 TEMPERATURE MONITOR DEVICE

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

INSTRUCTION MANUAL T154. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

NT511 RS485 MODBUS INSIDE

Process & TeMPerATUre UniversAl input DigiTAl MeTers

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Carbon Monoxide Transmitter

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

02/11/2015

DE20 INSTRUCTION MANUAL

Product Manual SZ1145

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

HTC-915-CONT. Heat-Trace Control system

Installation, Operating and Maintenance Manual

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Nov 08 PRODUCT SPECIFICATION SHEET

Product Manual SZ1144

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Mark 25 Ultrapure Water Conductivity Analyzer

TraceNet ECM Series Control System

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

RTD TEMPERATURE SENSING SYSTEM

Temperature Controllers

Two-Channel Gas Controller

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Thermal protection device for electric units

02/11/2015

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

I/A Series 716C 1/16 DIN Temperature Controller

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Multi-Gas-Controller MGC2

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

eed quality electronic design USER s MANUAL

BX444-Mc Gas Detector

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

INSTRUCTION MANUAL NT935 IR. operates with ISO9001 certified quality system

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

B-40/B-41 Modulating Temperature Controller

Product Manual SZ1009

Oxygen (O2) Single-Point Gas Detection System

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

NELSON CM HEAT TRACE CONTROLLER Installation and Operating Instructions

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

MINCO CT124 8-Channel Temperature Monitor

INSTALLATION & USER MANUAL

MODEL B2 INSTALLATION MANUAL

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

INSTRUCTION MANUAL NT935 IR. operates with ISO9001 certified quality system

Pioneer-R16 Gas Monitor Operator s Manual

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

N1540 Process Indicator

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Revised 10/3/2002. Ellis Intellitrol Washer Control Operation Manual

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

M2500 Engine Controller Installation Manual

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

MR3CCUHV Temperature/Defrost Control

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

20 Light Remote Annunciator

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

JDDT1 - Single Stage Digital Thermostat

SACE PR021/K SIGNALLING UNIT

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

R1000 / R1040 / R1080

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

F4 Process Controller Installation and Operation Guide

Software Version 2.01 LEVEL MONITOR MODEL 220

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Model 96VTR ¼ DIN Process Controller

Gas Controller Module GC-06

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Dual Input Toroidal Analyzer

Series Temperature Controller Instruction Sheet

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Duct and Rough Service Carbon Monoxide Sensor

SCHMIDT LED Measured Value Display MD Instructions for Use

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Current-Input-Module (CIM) MOTOR PROTECTION UNIT QUICK REFERENCE ESC. December 19, 2006 Revision 0 MAIN MENU. ²Messages Ñ. Metering Ñ.

Transcription:

Table of Contents Introduction...2 Mounting...2 Dimensions...2 Controls...3 Screen Displays...3 Screen Messages...4 Light Test...5 Control Power...5 Wiring...5 Inputs...7 Outputs...7 Programming...8 Technical Specifications...11 Testing...12 Warranty...12 Troubleshooting...13 Approvals...14 Options...14 Ordering...14 Programming Access Flow Chart...Appendix A Programming Flow Chart...Appendix B Test Access Flow Chart...Appendix C T538 Instruction Manual Rev # 6 June 25 1999 R6T538 June 25 1999.rtf E L Switchgear and Control Inc

Introduction Mounting The T538 temperature monitor will survey and control up to eight, three-wire RTD inputs. Each input channel may be user programmed with individual Alarm and Trip set points in a range of 0 to 240 C (32 to 464 F). The unit is microprocessor based which offers application flexibility, and easy integration to a variety of applications including electric motors; electric and diesel generators; all types of transformers; electric cables; and industrial and chemical processes. The thermal protection provided is covered by ANSI 49. The unit is intended for semi-flush mounting with hardware provided. Installation and set-up are simple using the universal power supply 24 to 240V AC or DC and functional user controls and display. T538 is designed for semi-flush panel mounting. Mounting hardware is included with each unit. The panel cutout dimension is 92 x 92mm (3.62 in. x 3.62 in.). Dimensions Ref Figure 1 96 x 96 x 150mm (3.78 x 3.78 x 5.90 in.) Figure 1 R6T538-JUN-1999.doc Temperature Monitor/Controller 2

Controls Screen Displays All functional controls and displays are located on the front of the unit. The unit has six input keys, two having dual functions. These are PRG/SET and ENT/RESET. Keys may be categorized as, programming, screen display, and test. Programming keys are located at the bottom of the unit and may be identified by the blue type. These are PRG, ENT, UP (symbol) DOWN (symbol). The screen display may be changed by the DISPLAY MODE key located to the upper right and is identified by the yellow type. The TEST key is located on the bottom between the programming keys. When the test provision is enabled the SET and RESET keys are activated, with the PRG and ENT keys disabled. Each active channel has three associated LED's; green, yellow and red. These LED's provide the channel status information. The LED colors are interpreted as follows: Green The associated channel information is being displayed on screen Yellow The associated channel has exceeded the alarm set point and the alarm output relay has changed state. Red The associated channel has exceeded the trip set point and the trip output relay has changed state. All messages and operating parameters are displayed on the screen. The DISPLAY MODE key controls the operating mode of the screen display allowing any one of four modes to be selected: hot, scan, man, or Tmax. An illuminated LED at the top left of the display indicates the active mode and depressing the DISPLAY MODE key toggles the four different modes The different modes display the following information. Hot All active channels are scanned, but only the temperature of the hottest channel is displayed on the screen. This mode does not affect protection. Scan Each channel is scanned for approximately three seconds during which the actual temperature of that channel is displayed on the screen. Man The temperature for each channel may be viewed manually by pressing the UP or DOWN key. The information displayed on the screen will be that of the channel whose green LED is lit. All active channels are still scanned but only the temperature of the selected channel is displayed. This mode does not affect protection. Tmax This value is logged in memory and is the maximum historical temperature recorded on any active input channel. A green LED identifies the channel which produced this temperature value. If an actual monitored temperature value exceeds the Tmax value in memory, then the new value is stored as Tmax.. The Tmax value may be reset by pressing the RESET key in this mode. R6T538-JUN-1999.doc Temperature Monitor/Controller 3

Screen Messages A variety of messages may be displayed on the screen. They may appear during programming or during normal operation as a result of component or unit failure. During the course of normal operation the following screen displays indicate fault conditions: FOC: Fault open circuit - RTD input to one or more channels has open circuited. An RTD may be disconnected or wires to it severed. This may also indicate that the number of active channels programmed does not match the actual number of RTD s connected or that RTD s have not been consecutively connected starting with channel 1. Indication is provided by illumination of the fault LED, operation of the fault output relay and identification of the affected channel by illumination of that channels green LED.. To reset the fault relay, push and hold the RESET key until RST appears on the screen. FCD: Fault sensor reading - RTD signal is erroneous. There is no visual indication The RTD is defective. The problem is detected by the internal circuitry of the T538 and may be caused by a variety of reasons. Wire routing, shielding and grounding are suspect. Identification is provided by illumination of the fault LED, operation of the fault output relay and identification of the affected channel by illumination of that channels green LED. This is a programmable feature that is enabled when the program option YES is selected ( see programming ) To reset the fault relay, push and hold the RESET key until RST appears on the screen FCC: Fault short circuit - RTD is short-circuited. The RTD has failed or the RTD type, and the unit are not compatible. Low resistance across an input channel causes this problem. Indication is provided by illumination of the fault LED, operation of the fault relay, and identification of the affected channel by illumination of that channels green LED. To reset the fault relay, push and hold the RESET key until RST appears on the screen. If all yellow and red channel LED s are simultaneously illuminated with the fault LED, it is likely that the RTD s are not compatible with the unit.. All other messages that may appear on the screen pertain to program or test functions. Refer to the programming or test sections for description s of those messages. R6T538-JUN-1999.doc Temperature Monitor/Controller 4

Light Test Control Power This test is conducted automatically after completion of programming or viewing programmed information. It is intended to provide visual indication of all illuminated LED s and their operation. It is advisable to carry out this test on a regular basis to ensure all lamps are functioning normally. Pressing the TEST key at any time allows the user to test all lamps. If any lamp is not functioning the unit must be returned for repair. The T538 has a universal power supply. It can be supplied with 24 to 240V AC or DC without respect to polarities. The ground cable must be fixed to terminal # 41 ATTENTION: The unit may be damaged by overvoltage when power is supplied directly from the secondary of the transformer it is monitoring. This may occur when the 240V is obtained directly from the secondary winding and there are fixed capacitors online. Use a control circuit transformer, with a secondary voltage of 24 to 120V AC or DC to avoid damage. ATTENTION: Disconnect the power supply to the T538 when conducting insulation testing with an AC or DC HiPot. Failure to do so may result in damage to the unit. Wiring Terminal blocks are located at the rear of the unit for all input channels (8), output relays (3) and control power. The terminal blocks are removable for ease of wiring Wiring connections are shown in Figure 2 R6T538-JUN-1999.doc Temperature Monitor/Controller 5

Figure 2 R6T538-JUN-1999.doc Temperature Monitor/Controller 6

Wiring (Cont.) Inputs Outputs RTD Sensor wiring and routing All sensor wiring must be: Separated from power wiring; Shielded cable with twisted conductors; Have a cross section of 0.5mm (22AWG); Be twisted conductor if no shield; Have tinned or silvered conductors; Be firmly fixed in the terminal board. The T538 will accept up to eight, three-wire RTD inputs. The standard unit is calibrated for 100-ohm, platinum RTD's. The T538 may also be ordered for use with 100 or 120-ohm, nickel RTD's. The RTD's must be terminated consecutively starting with channel 1, and the relay must be programmed for the number of active channels. (maximum eight) The standard version of the T538 incorporates three output relays; Trip, Alarm and Fault. All relays are single-pole, double throw. The trip and alarm relays are independently programmable for either fail-safe or non- fail-safe operation. When the fail-safe mode is selected, the relay contacts will change state when the unit is energized, (control power applied) and no trips or alarms are present. If the non failsafe mode is selected, the relay contacts will not change state under these same conditions. Each individual active channel can be programmed with trip and alarm temperature setpoints that are independent of other channels. The alarm and trip relays will change contact state when the respective set point temperature value is reached. The relays are user programmable for either manual or automatic reset. ( Hold feature) The unit self resets in automatic mode when the actual temperature value declines 1 C (2 F) below the set point values. To reset the relay contacts in manual reset mode, press the key marked RESET. The unit will only reset when all actual temperature values have declined below the programmed values. Illuminated LED s for alarm (yellow) and trip (red) flash coincidentally with the channel LED of the same color, when a set- point is exceeded. The channel indication ceases when the temperature falls below the set point value. Reset is possible when the only flashing LED is the alarm (yellow) or trip (red) indicator. The Fault relay is activated when the unit senses a defective RTD or component failure of the relay. This relay changes contact state when the unit is powered on line. If the fault relay can not be reset the unit must be replaced. R6T538-JUN-1999.doc Temperature Monitor/Controller 7

Programming Getting started Programming the T538 is simple and requires no special tools. The set point values for alarm and trip for each active channel should be at hand. The unit will automatically step through each program sequence and upon completion will resume normal operation. The program sequence is as follows; 1) Set the number of active channels, maximum 8. 2) Input alarm temperature value for channel 1, range 0-240 C (32-464 F). 3) Input trip temperature value for channel 1, range 0-240 C (32-464 F). 4) Repeat steps 2 and 3 for all active channels. 5) Select sensor operation FCD, Yes or No *) Communication Option only- set baud rate *) Communication Option only-set address 6) Select program lockout, Yes or No 7) Select fail-safe or non-fail-safe for alarm relay 8) Select fail-safe or non-fail-safe for trip relay 9) Select Automatic or Manual reset for alarm and trip relay 10) Press ENT to return to normal operating mode Unit will perform light test and return to normal operation. Programming Sequence 1) To begin programming, press the PRG key for approximately seven seconds. During this interval the main screen display will present the message SET and then flash the message PRG. The unit will then advance to the first program selection, and the PROG light above the PRG key will illuminate. In the event program access is blocked the display will show SET and then display nop. This prevents unauthorized entry to the program set points. To gain access, press the ENT key and return to normal operation. Touch the PRG key and then, press and hold the TEST key for approximately 7 seconds until the flashing PRG screen display ends, and the message nch is displayed. Press ENT and return to the opening sequence. NOTE: This procedure removes the lockout feature. To block access, this feature must be reprogrammed 2) After each selection press the PRG key to advance to the next selection. At any time during the program sequence you may discontinue by pressing the ENT key. To enter programming again you must repeat the sequence above. 3) To review the entered values, momentarily press the PRG key and continue to do so advancing to each programmed value. 4) After advancing to any program selection, use the up/down keys to enter your selection, or set point value. During the programming sequence a timer allows 60 seconds for any input. If time elapses and no input is made the unit reverts to normal operation. As the unit advances to each of the program selections the main LED screen will display a message or set point value. When entering set point values for an active channel a green LED will illuminate indicating the channel being programmed. The yellow channel LED and alarm LED will simultaneously light when the alarm set points for the channel is programmed. The red channel LED and trip LED will simultaneously light when the trip set point for the channel is programmed. R6T538-JUN-1999.doc Temperature Monitor/Controller 8

Programming (Cont d) Enter Program Values 1) Set the number of active channels Screen display: n.ch. alternating with a numeric value Options: 1 to 8 Complete: Press PRG Advance 2) Alarm temperature set point value for channel 1 Screen display: Numerical, channel LED green and yellow, Alarm yellow Options: 0-240 C (32-464 F) Complete: Press PRG-Advance 3) Trip temperature set point value for channel 1 Screen display: Numerical, channel LED green and red, Trip red Options: 0-240 C (32-464 F) Complete: Press PRG-Advance 4) Repeat above for each active channel 5) Select sensor operation FCD Screen display: FCD alternating with YES or NO Options: Yes/No (select YES for erroneous detection of input signal) Complete: Press PRG - Advance *) Optional Does not apply without RS485 communication option Screen display: Baud Options: 300-1200-2400-9600 parity=n stop=1) Complete: Press PRG - Advance *) Optional Does not apply without RS485 communication option Screen display: address Options: 0-32 Complete: Press PRG - Advance 6) Select Program Lockout Screen display: PRG alternating with YES or NO Options: Yes/No (select NO to block access) Complete: Press PRG-Advance R6T538-JUN-1999.doc Temperature Monitor/Controller 9

Programming (Cont d) 7) Set Alarm fail-safe or non-fail-safe Screen display: FLS- yellow LED illuminated at Alarm, alternating YES/NO Options: Yes/No Complete: Press PRG-Advance 8) Set Trip fail-safe or non fail-safe Screen display: FLS- red LED illuminated at Trip, alternating YES/NO Options: Yes/No Complete: Press PRG - Advance 9) Set Alarm and Trip Relay for Hold, Automatic or Manual reset Screen display: HLD, alternating with YES/NO Options: Yes (manual) / No (automatic) Complete: Press PRG Advance The program selection automatically advances to each step. From step 9 It returns to step 1. At any time during the program sequence you may quit, by pressing the ENT key. After pressing the ENT key the unit performs a light test and reverts to normal operation During programming, pressing the PRG button saves the value entered. If the value entered is invalid the unit will not accept the entry.the screen will display ERR ( error) and the unit will not move to the next program mode until a valid program selection is entered. R6T538-JUN-1999.doc Temperature Monitor/Controller 10

Power Supply TECSYSTEM S.r.i TECHNICAL SPECIFICATIONS Communication Rated voltage 24-240 Vac-dc 50/60 hz Voltage limits 20-270 Vac-dc 50/60 hz Vdc with reversible polarities Inputs Eight inputs RTD sensors 3 wires Removable rear terminals Input channels protected against electromagnetic noises and spikes Sensor cable length compensation up to 500 m (1 mm²) 10 ohm max. Opt. 8 analog inputs 4-20mA (range 0-240 C (32-464 F)) Tests and Performances Assembling in accordance with CE rules C-UL-US Approval # E194027 Protection against electrical and magnetic noises: CEI-EN50081-2/50082-2 Dielectric strength 2500 Vac for 1 min. from relays to sensors, relays to power supply, power supply to sensors Accuracy: ± 1% full scale, ± 1 digit Ambient operating temperature -20ºC to 60ºC (-4ºF to 140ºF) Humidity 90% non-condensing ABS self-extinguishing housing NORYL 94VO Frontal in polycarbonate IP54 Burden 3VA Data storage 10 years minimum Digital linearity of sensors signal Self-diagnostic circuit Opt. Protection treatment of electronic part Opt. frontal plastic protection Opt. Output RS232/485 Modbus RTU Outputs Two Output relays (Alarm -Trip) One relay for sensor fault or abnormal unit operation (FAULT) Output contacts capacity: 5A-250Vac res. Arranged for output relays test Fail-safe/non - fail-safe programming of Alarm/Trip output relays Optional relay (AUX) Displaying and Data Management One display, 13mm (0.5 in.) high 3 digit with 3 digit for displaying temperatures Eight LED's for displaying reference channel Eight LED's indicating alarm or trip LED indicating fault Temperature monitoring from 0-240 C (32-464 F) Two thresholds for each input Sensors diagnostic (FCC-FOC-FCD) Programming by frontal push button Automatic output from programming cycle after 1 min. of no operation Wrong programming automatic display Programmed data call out Possibility of setting manual channel scanning or hottest channel Maximum temperatures storage Number of channels software programmable from 1 to 8 Dimensions 96 x 96mm (3.78 x 3.78 in.) -DIN N43700-Prof. 150mm Deep (with rear terminals) panel cutout 92 x 92mm (3.62 x 3.62) R6T538-JUN-1999.doc Temperature Monitor/Controller 11

Testing Temperature Simulation. Warranty All relays may be tested using the following procedure: 1) Press and hold the TEST key for 7 seconds. Initially all LED s illuminate, changing to the main screen display flashing TST 2) Release the test key when the yellow relay test LED illuminates. The screen display will show FLT and the red LED indicating fault relay, is illuminated. 3) Test the fault, alarm, or trip relay. Use the Scroll up/down keys to make the selection. The screen display will show the relay selected for testing. Yellow (alarm) and red (trip) LED s are visible as the relays are tested. To perform the test, press the SET (white print) key and check for contact operation. To reset press the RESET (white print) key. 4) To discontinue operation and revert to normal operation, press the TEST key. At the start of the test, a timer is automatically initiated which reverts the unit to normal operation if no inputs are detected for a period of five minutes Connect fixed or variable resistors across all channels to simulate RTD inputs. All resistors must be connected to the input channel using the three terminations provided. This is achieved by terminating the resistor to the two lowest termination numbers of each channel, with a jumper from the middle to the highest number. Example Channel # 1 Termination # s 13-14-15 Connect the resistor across 13-14 Connect the jumper from 14-15 Repeat for all channels The resistance values for all inputs must be variable between 100 and 200 ohms Connect the T538 to a suitable power supply. Set the resistance values to a corresponding temperature value for the RTD type being used. All RTD s have published resistance vs. temperature values. For 100 ohm platinum a resistance value of 175.84 ohms will yield 200 degrees C. A resistance of 138.50 ohms yields a temperature of 100 degrees C. Check to verify readings on the main display. The unit is completely functional with the resistors connected, and complete evaluation is possible following the instruction manual. The T538 is warranted for a period of 18 months from date of shipment. Warranty is limited to repair or replacement of the defective product and no contingent liabilities will be accepted. Warranty will be voided if the unit is found to be tampered with or it has been damaged as a result of incorrect input or power supply connections, or is damaged as a result of transitory over voltages. Freight expense is not covered under warranty. R6T538-JUN-1999.doc Temperature Monitor/Controller 12

Troubleshooting Problem The unit will not switch on, with control power energized The sensor is damaged One of the eight channels is indicating fault, and displaying FOC/FCC Causes / Solution Check the terminal block for correct installation Check for voltage at terminal block The fault relay closes and the fault LED switches on. The red LED of the respective channel is illuminated. A message is displayed. FOC- sensor open FCC- sensor is short circuited Check the sensor connections. Look for damaged sensors. Replace damaged sensor When switching the unit on-off, alarm and trip relays energize All the sensors are displaying FCC The temperature indicated by one, or more channels is wrong Sudden activation of the trip relay with normal operating temperature, One channel caused the occurrence Strong electrical noise is being picked up on the power line. Install a transient suppressor (PT73) Check to ensure the shield of the sensor cable is connected to the panel ground Install shielded cable, or twist the sensor conductors Wrong wiring connections The terminal block is upside down The sensors are defective. Check the sensor resistance for compatibility, with your unit. The unit is calibrated incorrectly Return for repair Sensor defective FCD Replace the sensor With a control power source of 24VDC the unit switches off, and will not switch back on Check the input voltage is between 20-24VDC Reconnect to a stable source of power Return if unit does not respond R6T538-JUN-1999.doc Temperature Monitor/Controller 13

Options Protective display cover Analog output Communications Auxiliary relay output 10 ohm copper, 120 or 100 ohm nickel RTD input Analog Output The analog output value is 4-20 ma. full scale. This is a linear output corresponding to a temperature range of 0 to 240 degrees C. The T538 is designed to work with an external power supply, having the following specifications: Power: 24 VDC +/- 5%, @ 150 ma. 3VA Operating temperature 0 to 60 degrees C Isolation voltage 2.5 KV AC Maximum ambient humidity 90%RH non condensing Contact EL Switchgear for information concerning this item. RS485 Communications Modbus RTU Programming for the T538 will include inputs for baud rate and unit address with this option. Documentation of this feature will be forwarded under separate cover Approvals Assembled in accordance with CE rules. Protection against electrical and magnetic noises CEI-EN50081-2/50082-2 C- -US approval, File No, E194027 Ordering To order, select the basic model and the desired features from the selection Guide below. T538 Mod * * * * Basic Model 100 P 100 ohm platinum RTD 100 N 100 ohm nickel RTD 120 N 120 ohm nickel RTD 10 C 10 ohm copper RTD AO AI 4-20Ma output (optional) Analog input 4-20 Ma (optional) RS Serial communications (optional) AUX Output relay (optional) R6T538-JUN-1999.doc Temperature Monitor/Controller 14

Appendix B T538 - Programming Program steps Program mode Screen Display Action Options Completion 1 Set Active Channels Maximum - 8 Screen Display: n.ch alterrnating with a numeric value Action: Scroll Up/Down Options 1 to 8: Complete: Press PRG - Advance Step 2 2 Input Alarm Temperature Value Range 0-240 C (32-464 F) Screen Display: Numerical, Channel LED green & yellow, Alarm Yellow Action: Scroll Up/Down Options 0-240 C (32-464 F) Complete: Press PRG - Advance Step 3 3 Input Trip Temperature Value Range 0-240 C (32-464 F) Screen Display: Numerical, Channel LED green & red, Trip red Action: Scroll Up/Down Options 0-240 C (32-464 F) Complete: Press PRG - Advance Step 4 4 5 6 7 Repeat Steps 2 & 3 For All Active Channels Select Sensor Operation FCD Yes/No Select Program Lockout Yes/No Select Fail-Safe or Non-Fail-Safe For Alarm Relay Screen Display: FCD alternating with Yes or No Screen Display: PRG alternating with Yes or No Screen Display: FLS yellow LED illuminated at Trip, Alt. Yes/No Action: Scroll Up/Down Action: Scroll Up/Down Action: Scroll Up/Down Options Yes/No - Select Yes for auto detection of input signal Options Yes/No - Select No to block access Options Yes/No Complete: Press PRG - Advance Complete: Press PRG - Advance Complete: Press PRG - Advance Step 6 Step 7 Step 8 Exit Program For Normal Operation Any Time Press ENT 8 Select Fail-Safe or Non-Fail-Safe For Trip Relay Screen Display: FLS red LED illuminated at Trip, Alt. Yes/No Action: Scroll Up/Down Options Yes/No Complete: Press PRG - Advance Step 9 9 Select Automatic or Manual Reset for Alarm & Trip Relay Screen Display: HLD, alternating with Yes/No Action: Scroll Up/Down Options Yes (Manual) /No (Automatic) Complete: Press PRG - Advance Step 10 10 Repeat steps 1 to 9, or Press ENT to revert to normal operation * If RS485 communication option is ordered the program sequence would include input set points for baud rate and unit address. The programming steps are inserted between 5-6. Documentation is included under separate cover

Appendix A T538 - Program Access Program Access Screen Display Actions Press and Hold PRG key for Approx Seven seconds set PRG Flashing no P Flashing PROG LED illuminated n. CH. Flashing program step #1 Enabled n. CH. Flashing program access denied Release PRG key Release PRG key to gain access PRG flashing 888 light test Hold TEST key for approx 7 seconds n. CH. Flashing Release TEST key Press ENT To remove program block

Appendix C T538 - Test Access Test Access Screen Display Actions Press and Hold Test key for Approx Seven seconds tst Flashing 888 light test Press TEST To revert to normal operation Any time Fault LED red Relay LED yellow illuminated flt. Release TEST key Select Relay to test Scroll Up/Down LED indication of relay being tested Relay selected for testing Fault Trip or Alarm Press SET To force contacts Press RESET To reset contacts