WELCOMES CUSTOMERS AND BUSINESS PARTNERS

Similar documents
Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

The Advantages of Choosing Centrifugal Fans

Get The Edge Over The Competition with The Summit

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

SmartRad Planning Manual

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Frequently Asked Questions

termo plus High Efficiency Radiator Novelty in Heating Systems Designed by Engineering Germany

"Best Practices in Modern Hydronic Heating - THE DETAILS

Applications and Piping Strategies for Condensing Boilers - Introduction

Home owner user pack for the Nibe 200P

Everything you need to know about Radiant Heating but didn t dare ask

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

Lowara ecocirc and ecocirc PREMIUM

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

Secondary systems used in Europe.

prestige Control Application Supplement - Type 5 MCBA WARNING

G124X - G234X - G334X Atmospheric Gas Boilers

It doesn't cost the earth

Kills bills. How Vaillant technologies reduce home heating bills

prestige Control Application Supplement - Type 5 MCBA WARNING

Affordable efficiency!

RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators

Intelligent Heating for Your Home

UNDERFLOOR HEATING GUIDE

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

Introduction to Fans. The Basics of Fan Principles and Terminology

EFG ENERGY OPTIMISING SYSTEMS

INDUSTRIAL AIR CURTAIN. IndAC 2

Live in the comfort of your own home

OVERVIEW OF THE ELECTRIC RADIATORS RANGE

Whether you are coming in from a cold night, a heavy rain shower or a long day at work nothing is more inviting then a Joule Underfloor Heating

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR

Heating Installation Guide published by

UNVENTED STAINLESS STEEL CYLINDERS

The skirting board that heats your home...

Selecting the Correct Fan

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

The Sterling Series. Pressing Excellence. Pre Pressing Full Pressing Rendering

Energy Saving Series RADICAL

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

- Essay Control Functions and Benefits

Radiant Heating. Systems

Donʼt do this with ANY hydronic heat source! Heat transfer between the water and the upper floor surface is severely restricted!

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Heating controller with optimisation functions

- Data Brochure Universal Reset Module 423

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

System 70 Datasheet/0105

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Safe Heating in Sheltered and Social Housing

TopGas Wall Hung Condensing Gas Boiler

NOW FUTURE BUILDINGS CATALOGUE EUROPE SPRING / SUMMER 2018 HEALTHIER INDOOR CLIMATE + ENERGY SAVINGS WITH ULTRA-EFFICIENT SOLAR AIR TECHNOLOGY

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

Trim Pump Impellers. Fredrick/Weinman Engineered Products 2-1/2 KH, 2-1/2 x 3 x 12

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

- Data Brochure Boiler Control 274

Lowara ecocirc and ecocirc PREMIUM

6800 Design Envelope Booster. Technical overview

Sweden s leading air source heat pump

Range Brochure July heatingthroughinnovation.

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability

Stylish. Efficient and Comfortable. Low Energy. Environmentally friendly

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS

Solar Heat Pumps Domestic Range

HVAC Water chiller selection and optimisation of operation

The electrical wattage needed by the circulator is:

Temperature Control for

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Axial flow fan AXICO ANTI-STALL

Best Practices for Condensing Boilers

INNOVATION GATEWAY. Challenge Selection Round 2, Innovator Briefs Building heating systems

UNIT 4: REFRIGERATION PRINCIPLE

Manufactured....installed worldwide MADE IN BRITAIN

Independent Study Shows Sludge Build-up Significantly Affects Hydronic Heating System Performance

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

VRV The total solution. Integrated Climate Control

Radical CPD BIM.

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

The simple solution to a daily challenge

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Welcome To. System Benefits With ECM PUMPS

The complete energy-saving range.

HVAC Maintenance for DIYers

LUCKILY THERE S A BETTER WAY

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

HL SERIES Fluid heating for commercial applications

AC Backward Curved Motorized Impellers

Transcription:

AUBREN TECHNOLOGY

WELCOMES CUSTOMERS AND BUSINESS PARTNERS

< 1 YEAR 3 YEARS PRODUCT IDEA ENGAGE AUBREN NO PARTNER US & YOU YOU DESIGN TECHNOLOGY RECRUIT, TRAIN & DESIGN MAKE STRATEGY DELIVER MARKETING PRODUCT LAUNCH ASSEMBLE A MULTISKILLED TEAM FIND A MANUFACTURING PARTNER LOGISTICS TECHNOLOGY FROM IDEA TO LAUNCH STRATEGY MARKETING PRODUCT LAUNCH

KEY MOMENTS IN THE EVOLUTION OF AUBREN

AN ADVANCED, HIGHLY SPECIALIST MANUFACTURING FACILITY We operate a 3,000 square meter, highly-specialist, advanced manufacturing facility. It is located in Portlaoise, at the centre of Ireland, adjacent to all motorways, and one hour from Dublin airport. A facility which operates and produces to world class standards. OUR FACTORY IS YOUR FACTORY

QUALITY Quality, Environmental and Safety Policies. QUALITY ENVIRONMENT SAFETY

AUBREN TECHNOLOGY

AUBREN SOLO RADIATORS Patented Design Technology Manufactured in Europe Aubren has pioneered Hydronic Heating with the patented Solo system which like conventional heating systems is water based, but differs in that minute quantities of water are used, and advanced control techniques are embedded into the Solo Hydronic to help reduce boiler size whilst delivering exactly the heat required where and when needed with no warm up time. Solo is designed and manufactured and technically supported in Ireland by Aubren, a technology company specializing in the delivery of low energy heating and ventilation products.

ENHANCES COMFORT, AND STYLE OF INDOOR SPACE Stylish & Discrete Solo blends unobtrusively with all environments, whether commercial, institutional or domestic. Surface Temperature never reaches danger levels regardless of water temperature. Added safety for children and the elderly. Fastest Heatup Time. A Solo will generate significant heat immediately hot water is available to it Total control with minimal energy waste Significantly smaller than conventional radiators easier to locate in room. Available in standard white or architect specified colours.

ENHANCES COMFORT, HEALTHINESS AND STYLE OF INDOOR SPACE Eliminates Wall Stats and allows room by room temperature control. Small and Stylish Design compliments all Décor in homes or commercial spaces. No need to design the room around the radiators. Slimmest on the market. Summer Comfort Cooling Kick-Space or Hideaway version available for kitchen or bedroom spaces uses no wall space. Boost feature ignores temperature for 20 minutes and activates high airflow, then reverts to temperature control.

SMARTER

SMART TECHNOLOGY FOR THE MODERN INDOOR SPACE Solo requires no water valves to prevent heat emission when not required. Even with 85 0 C water flow, there will be zero convection, but there will be a minor degree of heat radiation from the coil surface. As all Solo s can be on a single flow and return pipe system, zoning can be simply done by grouping areas electrically and feeding them from timeclocks or switches. Thus, eliminating the need for zone valves and piping complexity. Radiator selection is simple. There are only two capacity sizes, and they will automatically adjust capacity as required. All controls are built in with no external requirements.

SOLO ALLOWS TOTAL CONTROL WITH MINIMAL ENERGY WASTE Fast Acting Low Water Content Capacity Control Temperature Control Remote shutdown of pumps Setback feature Boost Function No unreliable valves

CORRECT CHOICE

SOLO BETTER CHOICE FOR HEATING SPACE Boiler Sizing Low Thermal Mass Solo allows the designer to base the capacity on design heat loss, and not on the capacity to bring the temperature up in a reasonable time. This is possible because Solorad essentially may be considered as a variable size radiator, which becomes large or small as dictated by how cold the environment is relative to desired temperature. The low thermal mass of Solo dramatically assists in both response as well as boiler or heat pump sizing. This allows the designer to downsize the boiler or heat pump by 40-50% relative to conventional sizing practice. Condensing Boiler Operation Because Solo operates effectively at much lower water temperatures than radiators, condensing boilers can be made condense under all load conditions. This results in major energy savings

SOLO BETTER CHOICE FOR HEATING SPACE Heat Pumps Due to the fact that Solo can operate at low water temperatures, Solo is ideal for use with Heat Pumps. This was a primary design goal for Solo. Constant flow through the system greatly assists correct operation of heat pumps. System Balancing Pump Selection & Pressure There is no balancing requirement with Solo as the hydraulic resistance relative to that encountered in flow and return piping is such that virtually the exact same flow will be provided to each terminal. This is also aided by the lack of valves in the system. A further advantage ensues in selecting water pumps based on a constant flow rate. The installer must however ensure that circulation pumps are adequately sized 6-7M head is recommended. Solo is tested to 9 bar, and unlike radiators, this allows higher pressure systems to be used where required.

SOLO BETTER CHOICE FOR HEATING SPACE Heatup Time A Solo will generate heat immediately. For example, a conventional radiator delivering 6KW typically might weigh 90 Kg, and contains 15L of water. The energy required to bring both iron and water from 10 0 C to 80 0 C is 960W.hr. This is before the radiator emits any heat. By contrast, Solo only needs 37 W.Hr. A conventional radiator needs 25 times more energy before it begins to heat than Solo does. Overheating Waste Energy When temperature is satisfied by conventional radiator or underfloor, all the energy required to heat the system itself is emitted until the stored energy is dissipated and this is totally wasted by overheating the space.

SOLO SIMPLER CHOICE FOR HEATING SPACE Two Lower Wall Mount Models air flow upwards. Solo 03 410H x 611W x 108D Solo 06 410H x 985W x 108D One Kick-Space Model air flow from wall Solo Hideaway 03 120H x 700W x 418D Two Higher Wall Mount Models air flow downwards AirCurtain 04 410H x 611W x 108D AirCurtain 09 410H x 985W x 108D All models are light and easy and cheaper to install a one person operation

SOLO THE INSTALLERS FRIEND No balancing of circuit Easy Pump selection Light - one person job. Only two sizes to choose from covers all. No valves just connect and run. Built in Controls and Stats Boost Function No unreliable valves

IRON RADIATORS??

SOLO vs RADIATOR Solo6 vs Iron Radiator Height 410mm vs 395mm Width 985mm vs 1556mm Metal Weight 0.68Kg Cu vs 26.04 Kg Steel Water Content 0.3L vs 10 L Typical Ten Solo6 vs Ten Radiators Heatup Period 1 min vs 28 min Room Air Rotation 8 min vs 15 min Stratification Period 2 mins vs 8 mins Initial Time to Satisfy Load 11 mins vs 51 mins Energy to Heat from 10-70C Metal 19 Btu vs 924 Btu Water 90 Btu vs 2987 Btu Total 109 Btu vs 3911 Btu

1 Min 8 min 2 Min 9 Min 9 Min 9 Min 9 Min 9 Min 9 Min 9 Min 9 Min 9 Min Startup Phase Air Rotation Stratification Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle 28 Min 15 Min 8 Min 19 Min 19 Min 19 Min 19 Min 19 Min Startup Phase Air Rotation Stratification Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle Reheat Cycle SOLO vs RADIATOR Startup Air Rotation Stratification Cycles Total Run Time Radiator 28 15 8 114 165 Solorad 1 8 2 90 101 Radiator Model Time Solorad Model Time Based on the above, Solorad saves 64 minutes on boiler run time compared to radiators. This represents a reduction of 40% on boiler time giving a 40% energy saving* * Ask for our detailed calculation datasheet.

UNDERFLOOR??

SOLO vs UNDERFLOOR Response Control Energy Cost Because underfloor heating entails a time lag of several hours between injecting heat energy into the floorslab, and releasing heat to the environment, this is actually out of step with our rapidly changing climate patterns. Solo instantly generates what s required when required. Underfloor heating is in fact a storage heater (which is degraded when carpeted or floored with wood). A wall stat located in static air cannot control comfort conditions throughout an area when used with underfloor heating. A stat indicates the now temp. whereas a floor radiates historic heat input injected several hours previously which may have no bearing on the now temp. requirement. With underfloor, a decision is made by a timeclock or wall stat to run the system for a period. By the time the heat is emitted, there may be no need for heat that cannot be stopped. This is extremely wasteful.

SOL0 vs UNDERFLOOR Upstairs Operation Zoning Water Temperature This is always problematic with underfloor systems, and usually results in radiators being used. Whereas underfloor heating requires complex manifolds and valves, Solorad simply requires a single flow and return in plastic or copper with no valves whatever in the system regardless of how complex the zoning plan is. This leads to much more reliability and simpler piping. Boilers are inappropriate to the requirements of underfloor systems as the water temperature is too high. Reducing the temperature will destroy many boilers. Other methods are used to reduce the impact of the elevated water temperatures, but only heat pumps ideally match the requirements of underfloor heating. Boilers produce water only at a much higher temperatures to prevent corrosion, and this requires the use of mixing valves. These devices contribute to boiler short cycling which destroys efficiency. Solorad however operates at any water temperature from 35-85 o C

SOLO vs UNDERFLOOR Running Cost Solo based systems can operate at 50-70% or less, of the running cost on an underfloor system. Health Dust mites thrive in the heated carpet and rugs, - particularly at high relative humidity levels now found regularly in modern homes where ventilation can be poor. The warmest part of an underfloor installation is the carpet where there irritants thrive. Solorad in contrast, only heats the air. Summary People require to have control of their environment. The demise of electric storage heating was caused by lack of control and perceived high running cost. Underfloor heating is also storage heating by a different name, and suffers from many of the shortcomings of its electrical ancestors. Underfloor in summary, represents a considerable improvement over radiators, but suffers from lack of any real control and excessive complexity.

SOLO vs UNDERFLOOR International View The efficiency review of energy use states that only where sustained low outdoor temperatures are the norm, will underfloor provide the efficiency and comfort levels required. Climate across the Ireland, UK and much of Europe can provide all four seasons during a typical winter morning, and this renders the use of underfloor inappropriate, though it is still superior to radiators in some instances. As water temperatures are reduced by legislation, or the desire to use different heat sources such as heat pumps or Solar, radiators will become even larger with even greater Thermal Mass.

FAN SELECTION

SOLO - CORRECT FAN SELECTION IS CRITICAL The Solo patent provides for the exclusive use of backward curved impeller fans in radiators. They operate like a millwheel going backwards. They do not blow air, rather they generate pressure equally in all directions, thus ensuring most efficient operation of the heating coil. As the motor and impeller are all one, they are lifetime balanced, and as the tips are both aerofoil moulded and turning backwards, there is no dirt pickup and very little noise. They are also impedance protected, and can be spun backwards or indefinitely jammed while powered with no effect whatever. The inertia of the external rotor motor used in these fans allows gradual ramp up or down of speed with no noise Backward curved impeller fans are selected for Solo and used in an unconventional configuration to ensure that when stopped, there is zero convection, thus eliminating the need for water valves.

WRONG FAN SELECTION IS PROBLEMATIC The established competitors to Solo typically utilize tangential fans. These are rotating cylindrical wheels with fan blades extending in parallel along their length. Because of this length, it is fundamentally unbalanced and collects dirt due to the vanes cutting the air The motor weight rests on one end bearing, and none on the other bearing. Bearing wear and noise is problematic. Free convection can occur through the blades, and due to non aerofoil tips on the blades, fans are very noisy. Tangential fans are primary used on low grade domestic fancoils, or in large commercial heaters where the rotational speed can be greatly reduced by using much larger diameter fans. These fans have applications, but are not suited to a product such as Solorad.

SOLO USERS

SOLO USED IN COMMERCIAL, INSTITUTIONAL AND DOMESTIC HOMES 5000+ Domestic Homes Nursing Homes Retail Units and Offices Hotels and Restaurants Sports Halls and Parish Social Areas Creche and Montessori Schools Medical Day Care Facilities Modular and Factory Built Homes

AUBREN TECHNOLOGY

TALK TO US Address Email AuBren Limited Portlaoise Business & Technology Park Mountrath Road, Portlaoise, Co. Laois, R32 XT95, Ireland info@ie.aubren.com Phone Fax Website + 353 57 8664343 + 353 57 8664346 www.aubren.com