USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

Similar documents
Address of your installer

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

USER MANUAL HRV150S* HRV190S* AND ERV180S READ AND SAVE THESE INSTRUCTIONS

Address of your installer

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

VIGÖR HRV PLUS AND VIGÖR ERV

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

HEAT RECOVERY VENTILATORS AND ENERGY RECOVERY VENTILATORS CONSTRUCTO 1.0 MODELS: Model no.: (HRV with ports on top)

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

READ AND SAVE THESE INSTRUCTIONS

Heat Recovery Ventilators models:

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

INSTALLER AND USER MANUAL VENTILATION SYSTEM

HEAT RECOVERY VENTILATORS HRV 60H ERV 60H. User Guide AND ENERGY RECOVERY VENTILATORS. Model no.: (HRV with ports on top)

Heat Recovery Ventilation Systems OWNER S GUIDE

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Installation Information

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

For Models Superventor Series

Bosch Split-Type Ductless Air Conditioner / Heat Pump

TR Series - The Ultimate ERV

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

Put the V back in HVAC

PORTABLE AIR CONDITIONER

CMHC HOME MAINTENANCE CHECKLIST

Light commercial models

INSTALLATION GUIDE VB0180 VB0148

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

Indoor Air Quality Product Brochure.

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

Condensation on Your Windows?

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0

NEXXOS INVERTER USER MANUAL

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

Home Maintenance Schedule

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SLIDER CASEMENT AIR CONDITIONER

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

Owner s Manual CMC100 Dehumidifier

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

10-year industry best core warranty. 5-year warranty on balance of unit.

INSTALLATION INSTRUCTION & OWNER S GUIDE

OPERATING INSTRUCTIONS

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

HEAT & COOL MODEL (REVERSE CYCLE)

Owner s Manual TABLE OF CONTENTS

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

Owner s Manual CMC100 Dehumidifier

VACUUM CLEANER INSTRUCTION MANUAL. Model : RCC-240Y. Your RCC-240Y cyclone vacuum cleaner and its technical data:

DEHUMIDIFIER. User Manual 50BT, 70BT

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

HEAT RECOVERY VENTILATOR

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Inverter Split-type Room Air Conditioner

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

Home Set-up and Maintenance. Maintenance

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

PORTABLE AIR CONDITIONER

Up to 60 Pint Commercial Grade DEHUMIDIFIER

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Window Care & Warranty Information

The Family Ceramic Heater

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

USER S INFORMATION MANUAL (2,4)SG13B

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

Transcription:

USER GUIDE VB0100 MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS 07919 rev. B

About this Guide This guide uses the following symbols to emphasize particular information:! WARNING Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death. Denotes an instruction which, if not followed, may severely damage the unit and/or its components. NOTE: Indicates additional information needed to fully complete an instruction. TABLE OF CONTENTS 1. UNIT DESCRIPTION..........................................................3 1.1 SPECIFICATIONS...........................................................................3 2. FUNCTION OF THE ENERGY RECOVERY VENTILATOR............................3 2.1 ENERGY RECOVERY........................................................................3 2.2 DEFROSTING.............................................................................3 3. CONTROLS...............................................................4-5 3.1 MAIN CONTROLS..........................................................................4 3.1.1 3-POSITION SWITCH...................................................................4 3.1.2 LITE-TOUCH CONSTRUCTO...............................................................4 3.2 AUXILIARY CONTROLS......................................................................5 3.2.1 20-MINUTE LIGHTED PUSH-BUTTON........................................................5 3.2.2 60-MINUTE MECHANICAL TIMER...........................................................5 4. MAINTENANCE............................................................6-7 4.1 REGULAR................................................................................6 4.2 ANNUAL MAINTENANCE (FALL)................................................................7 5. TROUBLESHOOTING.........................................................8 CONGRATULATIONS! You have made an excellent choice! We have prepared this User Guide especially for you. Please read it carefully to ensure that you obtain full benefits from your Energy Recovery Ventilator unit. 1. This unit is intended for residential use only. 2. Some activities create dust or vapors which may damage your unit. You must, therefore, turn off and unplug your unit in the following situations: major renovation work housing construction sanding (e.g. gypsum joints, etc.) varnishing 3. During heavy snowstorms, the unit should also be turned off to avoid problems caused by snow penetration, even if it is equipped with anti-gust intake hood. 4. Power disturbances or very short power failures may cause the electronic control microprocessor to malfunction. If it does, disconnect the power plug from the outlet and wait approximately 30 seconds, then plug it back in to resume operation. 5. At least once a year, the unit mechanical and electric parts should be inspected by qualified service personnel. 2

1. UNIT DESCRIPTION 1. Filters 2. Blower assembly 3. Energy recovery core 2 3 1 1 VB0101 1.1 SPECIFICATIONS MODEL WIDTH HEIGHT DEPTH WEIGHT ELECTRICAL SUPPLY POWER CONSUMPTION CONSTRUCTO 1.5 QUATTRO 34 (864 MM) 16½ (419 MM) 17¼ (438 MM) 74 LB (34 KG) 120 V, 60 HZ 150 W CONSTRUCTO 2.0 QUATTRO 34 (864 MM) 16½ (419 MM) 17¼ (438 MM) 76 LB (35 KG) 120 V, 60 HZ 240 W 2. FUNCTION OF THE ENERGY RECOVERY VENTILATOR Your ventilation system will help eliminate poor air quality problems by drawing the stale and humid air out of the house and replacing it with fresh outside air. By eliminating accumulated pollutants and humidity, it maintains an optimum air quality and an ideal relative humidity all-year round. Shown with a forced air heating system; can also operate on its own. Installation may vary. 2.1 ENERGY RECOVERY Units equipped with a heat and humidity recovery core (enthalpic core) can reduce ventilation costs in winter as well as in summer. VH0006 During the heating season, the unit draws the humidity and heat from the stale air and tranfers them, in part, to the cold air entering the house, thus avoiding dryness problems and providing maximum comfort. Stale air to outside 4 C/40 F EXAMPLE (IN WINTER): Fresh air to building 18 C/64 F During the cooling season, the unit reverses the process, preventing the humidity from the outside air from entering into the house. EXAMPLE (IN SUMMER WITH AIR CONDITIONING): Stale air to outside 30 C/86 F Fresh air to building 27 C/80 F Fresh air from outside 0 C/32 F Stale air from building 22 C/72 F Fresh air from outside 32 C/90 F Stale air from building 25 C/77 F VF0042 VF0043 2.2 DEFROSTING When the outside temperature is below -5 C (23 F), recovery (of heat or energy) creates frost in the core. To maintain its proper operation, the unit is programmed to defrost the recovery core. The defrosting frequency varies according to outside temperature. Defrosting lasts 10 minutes. During the defrost cycle, the unit shifts to maximum speed and the dampers close. After defrosting, the unit returns to the operating mode previously selected by the user. 3

3. CONTROLS 3.1 Main Controls 3.1.1 3-POSITION SWITCH Location: Located on the side of unit. Purpose: To adjust air supply. How to operate on a daily basis Select LOW SPEED for normal daily operation. Select HIGH SPEED for excess pollutants and humidity (parties, odors, smoke, etc.). How to turn the unit off: Push switch to the REMOTE position.! WARNING Optional controls can still activate the unit, even when in REMOTE position. You must, therefore, unplug the unit to be absolutely sure it is off. VC0091 3.1.2 LITE-TOUCH CONSTRUCTO Location: Located in the busiest area of the house. Purpose: To adjust air supply and select the desired indoor humidity level. Activate the push-button. The color of the indicator shows the unit operating mode. Color Mode Suggested Use Green Intermittent Select this mode when you are away from the house for a few days. Also, when you deem the inside air is too dry in heating season, or too humid in cooling season. In this mode, the unit is OFF for 40 minutes per hour and ventilates at minimum speed the remaining 20 minutes of the hour. Yellow Min. Speed For normal daily operation. Ventilation Red Max. Speed For excess pollutants and humidity (parties, odors, smoke, etc.). Ventilation VC0075 MAX MIN INTERMITTENT L-T 4

3. CONTROLS (CONT D) 3.2 Auxiliary Controls 3.2.1 20-MINUTE LIGHTED PUSH-BUTTON Location: Purpose: Located in the bathroom or in other locations where there is temporary humidity excess or pollutants. To eliminate excess humidity produced by showers or other periodic activities producing pollutants. Press once to activate the push-button. The unit will operate on high speed for 20 minutes and the indicator will light up. To stop activation before the end of the 20-minute cycle, push one more time. The unit will get back to its previous setting. ON VC0082 3.2.2 60-MINUTE MECHANICAL TIMER Location: Purpose: Located in the bathroom or in other locations where temporary humidity excess or pollutants are present. To eliminate excess humidity produced by showers or other periodic activities generating pollutants. TURN PAST 20 OFF 10 20 30 This control activates the system to operate at high speed for periods varying from 10 to 60 minutes. 60 50 40 VC0017 5

4. MAINTENANCE! WARNING In order to prevent personal injury, turn off the unit and unplug it before performing maintenance. When cleaning the unit, it is recommended to wear safety glasses and gloves. Regular maintenance should be performed every 3 months. Annual maintenance should also take place every fall. 4.1 REGULAR 1. Turn the unit off and disconnect the power supply. VD0005 2. Unlatch the door. Lift the panel towards you. Hold it firmly and hit the right side of the panel. The door should slide to the left. 3. Clean the inside of the door with a damp cloth. VD0144 4. Clean the filters Remove the filters. Vacuum to remove most of the dust. Wash with a mixture of warm water and mild soap. You may add bleach if you wish to disinfect (one tablespoon per gallon). Rinse thoroughly. Shake filters to remove excess water and let dry. NOTE: Washing the filters in the top tray of the dishwasher is possible, but the aluminum frame might tarnish. VO0113 5. Clean the condensation tray with a damp cloth. 6. Check the exterior air intake hood: Make sure there are no leaves, twigs, ice or snow that could be drawn into the vent. Clean if necessary. Even a partial blocking of this air vent could cause the unit to malfunction. 7. Reassemble the components: Filters Door (The door is secured when you hear a click.) VD0191 8. Reconnect the power supply and turn on the unit. 6

4. MAINTENANCE (CONT D) 4.2 ANNUAL MAINTENANCE (FALL) Repeat steps 1 to 6 from the previous section and continue with the following steps: 1. Clean the energy recovery core When handling the energy recovery core, it is recommended to wear safety gloves. Handle the energy recovery core with care. The energy recovery core cannot be washed with water. Remove the recovery core. Remove dust using a vacuum cleaner with a soft brush attachment. 2. Clean the centrifugal fan wheels VO0114 2.1 Disconnect the fan motor wires. VE0050 2.2 Disconnect the rod activating the square damper (A). 2.3 Remove both screws (B) securing the fan assembly. 2.4 Pull the fan assembly (C) out of the unit. B C A VO0115 2.5 Check for any dust accumulation on the blades. Do not oil the motor! It is already permanently lubricated. VD0139 2.6 Clean with a small brush if necessary. 3. Put the components back in place: Fan assembly (screws, damper rod, fan motor wires) Energy recovery core Filters Door VD0106 4. Reconnect the power supply and turn the unit on. 7

5. TROUBLESHOOTING If you think your unit is malfunctioning, check some of the following: TYPE OF PROBLEM TRY THIS... 1 Nothing works. See if the unit is plugged in. See if the unit is receiving power from the house circuit breaker. 2 Condensation on windows Operate the unit at maximum speed (MAX.) during activities generating excess humidity (air too humid in wintertime). (family gatherings, extra cooking, etc.) Leave curtains half-open to allow air circulation. Store all firewood in a closed room with a dehumidifier or in a well ventilated room or store the wood outside. Do not adjust the thermostat of your heating system below 18 C (64 F). 3 Air too dry in winter or too Temporarily switch the Lite-Touch Constructo on Intermittent mode. humid in summer. Operate the unit at low speed (MIN). Temporarily use a humidifier in wintertime. Temporarily use a dehumidifier in summertime. 4 Air too cold at the air Make sure the stale air exhaust hood outside the house is not blocked. supply grille. Operate the unit at low speed (MIN.) Have the system s balancing checked. Have the unit s defrosting system checked. Install a duct heater. If the problem continues, contact your installer at the phone number or address listed below or call the following number to find an authorized service center near you: 1-800-567-3855 YOUR INSTALLER S ADDRESS